首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
A method is described for the determination of urinary hippuric acid by high-performance liquid chromatography. The method used ethyl acetate extraction for partial clean up of the urine. The separation was carried out on a reversed-phase column using 20% methanol in 0.01 M aqueous potassium phosphate containing 0.5% acetic acid as a mobile phase. The column effluent was monitored with a UV detector at 254 nm. Hippuric acid was separated from other normal urine constituents in less than 10 min. Metabolites of xylene and styrene did not interfere with the assay. Analytical recoveries from urine were excellent and peak height and concentration were linearly related.  相似文献   

2.
3.
A high-performance liquid chromatographic method for the determination of ethacrynic acid (EA) in human plasma is described. Plasma was prepared for analysis by addition of 4-(2,4-dichlorophenoxy)-butyric acid as an internal standard followed by acidification with hydrochloric acid and extraction with ethyl acetate. Separation was by isocratic reversed-phase chromatography, the column effluent was monitored at 280 nm and quantitation was performed using peak-area ratios. The linear range for EA determination was from 0.5 to 25 micrograms/ml with a lower limit of detection of 0.1 microgram/ml. The reported method is convenient, sensitive and reproducible, illustrating its usefulness for pharmacokinetic studies.  相似文献   

4.
A sensitive, selective, and rapid high-performance liquid chromatographic procedure was developed for the determination of isoxicam in human plasma and urine. Acidified plasma or urine were extracted with toluene. Portions of the organic extract were evaporated to dryness, the residue dissolved in tetrahydrofuran (plasma) or acetonitrile (urine) and chromatographed on a mu Bondapak C18 column preceded by a 4-5 cm X 2 mm I.D. column packed with Corasil C18. Quantitation was obtained by UV spectrometry at 320 nm. Linearity in plasma ranged from 0.2 to 10 micrograms/ml. Recoveries from plasma samples seeded with 1.8, 4 and 8 micrograms/ml isoxicam were 1.86 +/- 0.077, 4.10 +/- 0.107 and 8.43 +/- 0.154 micrograms/ml with relative standard deviations of 3.3%, 2.5% and 5.4%, respectively. The linearity in urine ranged from 0.125 to 2 micrograms/ml. The precision of the method was 3.3-9.0% relative standard deviation over the linear range.  相似文献   

5.
A blood plasma sample was spiked with flurazepam and its metabolites and diluted with water (1 + 1); after protein precipitation, flurazepam and three of its metabolites were extracted into ethyl acetate at pH 9. After evaporation of the solvent, the residue was dissolved in the mobile phase for injection onto a reverse-phase LiChrosorb column; eluents were methanol-water (62:38) for separation of the metabolites and methanol-phosphate buffer (85:15) for flurazepam. The limit of detection varied from 0.1 to 1.6 ng. Recoveries from spiked plasma (1 μg ml?1) were 94–95%. At 254 nm, the response was usually linear over the range 5–50 ng.  相似文献   

6.
7.
8.
An assay using high-performance liquid chromatography has been developed for the determination of bromazepam in plasma. After a single-step extraction from basified samples with dichloromethane, using decarboxyloflazepate as an internal standard, samples were analysed using a reversed-phase Nova Pak 5-microns column with a mobile phase of methanol - phosphate buffer (60 + 40) adjusted to pH 7.6. The drugs were detected at 239 nm and the limit of detection was found to be 3 micrograms l-1 for bromazepam. The method is simple, rapid and sensitive and permits bromazepam levels in clinical and pharmacokinetic studies to be monitored.  相似文献   

9.
A simple and sensitive method for determination of benzodiazepines in plasma has been developed using high-performance liquid chromatography in a reverse-phase mode. The method is illustrated by application to plasma samples containing diazepam and N-desmethyldiazepam at concentrations which would be encountered during therapy, with limits of detection of 10 ng/ml and 2 ng/ml for diazepam and N-desmethyldiazepam, respectively.  相似文献   

10.
11.
12.
13.
14.
15.
A high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of fluvoxamine and its major metabolite fluvoxamino acid in plasma. Fluvoxamine and fluvoxamino acid in plasma were extracted using a C18 bonded-solid phase cartridge, followed by C4 reversed-phase HPLC separation.Fluvoxamine, fluvoxamino acid and moperone as an internal standard were detected by ultraviolet absorbance at 254 nm. It was possible to determine both fluvoxamine and fluvoxamino acid in the concentration range of 25.0-200.0 ng/mL, respectively. The detection limits of both fluvoxamine and fluvoxamino acid were 10.0 ng/mL, respectively. The mean recoveries of fluvoxamine and fluvoxamino acid added to plasma were more than 94.0% and 96.5%, with a coefficient of variation of less than 7.6% and 8.2%, respectively. This method has been used for the simultaneous determination of steady-state plasma concentration (Css) of fluvoxamine and fluvoxamino acid in depressive patients treated with 200 mg of oral fluvoxamine dosed as 100 mg twice-daily. The Css values of fluvoxamine and fluvoxamino acid in twelve Japanese patients were showed individual variations, which were in the range of 48.3-532.9 ng/ml and 35.6-307.1 ng/ml, respectively.  相似文献   

16.
17.
A simple, rapid and sensitive method for the determination of iothalamic acid (IA) in both plasma and urine is reported. After extraction with ethyl acetate, IA was determined by strong anion-exchange high-performance liquid chromatography with ultraviolet detection at 254 nm. The lower limit of detection was 0.5 micrograms/ml. The average recovery was 73 and 57% from plasma and urine, respectively. Linearity was found over the investigated concentration range (up to 500 micrograms/ml for plasma and up to 10.0 mg/ml for urine). The reproducibility of the technique was good (coefficient of variation less than 6%) as was the precision and accuracy (coefficient of variation less than 2.5%). No interference from endogenous substances or any of the common drugs tested was found.  相似文献   