首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Acylcarnitine profiling in dried blood spots (DBS) is a useful method for high-throughput newborn screening of metabolic disorders, but differentiation of isobaric and isomeric compounds is not achievable. Chromatographic methods for separation have already been reported but are specific for short-chain acylcarnitines or time-consuming. The aim of this work was to develop a fast ultraperformance liquid chromatography (UPLC)-tandem mass spectrometry (MS/MS) method for separation and quantification of a large number of acylcarnitines, including dicarboxylic acylcarnitines and hydroxyacylcarnitines, in DBS and plasma samples. Acylcarnitines from DBS and plasma were converted to their butyl esters and analyzed by electrospray ionization MS/MS. Chromatographic separation was achieved using a UPLC system equipped with an ethylene-bridged hybrid C(18) column. The correlation coefficients of the calibration curves (r(2)) ranged from 0.990 to 0.999. The limit of detection ranged from 0.002 and 0.063 μM for all compounds, and the limit of quantification ranged from 0.004 and 0.357 μM. Precision ranged from 0.8 to 8.8% and the mean recovery was 103%. Profiles of acylcarnitine isomers were investigated in specimens obtained from patients diagnosed with different inborn errors of metabolism. Acylcarnitine concentrations were also measured in 58 term newborns and compared with flow injection analysis measurements. With this newly developed UPLC-MS/MS method, the simultaneous detection of 61 (13 of these labeled) acylcarnitines in DBS and plasma can be achieved in 15 min including postrun equilibration. The method has been validated and can be used as an important component of newborn screening methods as a second-tier test for discrimination and to confirm diagnosis.  相似文献   

2.
Newborn screening is one of public health concerns designed to screen infants shortly after birth. Prenatal exposure to tobacco smoke such as nicotine has been reported to affect babies. Levels of nicotine and cotinine in meconium were widely used to evaluate the tobacco exposure of foetuses during pregnancy in a polluted environment. In this study, medical swabs were applied by using touch spray‐mass spectrometry (TS‐MS) to collect meconium from newborn infants for detection of nicotine and cotinine. Parameters such as choice of spray solvents, solvent volume and collision energy for screening of nicotine and cotinine were optimized. The limits of detection, reproducibility and matrix effect for analysis of meconium were also investigated. In this study, the levels of nicotine and cotinine in 54 puerpera volunteers were screened by TS‐MS and were validated by using traditional liquid chromatography‐mass spectrometry. These results showed that medical swab TS‐MS would be useful for newborn screening of nicotine and cotinine in meconium with high reproducibility, speed, sensitivity and specificity. The use of disposable medical swabs involves no sample preparation and no chromatographic separation, significantly reducing the cost and time required for screening a large number of clinical sample. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
Espy RD  Manicke NE  Ouyang Z  Cooks RG 《The Analyst》2012,137(10):2344-2349
Paper spray mass spectrometry is applied to oncology drugs in fresh whole blood samples supported on filter paper substrates instead of dry blood as done previously. Addition of the coagulant alum clotted the blood and allowed for immediate sample analysis. The coagulant did not interfere with the function of the paper spray nor did it add features to the mass spectra. Quantitative analysis of therapeutic drugs in the blood was achieved utilizing internal standards which were pre-spotted onto the filter paper. Eight oncology drugs were examined, with lower limits of detection ranging between 0.5 and 17 ng mL(-1) and linear dynamic ranges greater than two orders of magnitude. Inter-day accuracies of quality controls for pazopanib ranged from 102 to 118%, with imprecisions of 9 to 13%. This one-step method requires 10 μL of blood, a drop of solvent, and takes 45 seconds per trial. These results indicate applicability to point-of-care therapeutic drug monitoring in a clinical setting.  相似文献   

4.
A new analytical approach, using paper spray tandem mass spectrometry, has been developed for assay of carnitine and acylcarnitines in urine. Paper spray (PS) is a very promising technique, especially in clinical investigations, because of its simplicity, low cost, and rapid sample preparation. A home-made paper spray device was used for assay of urinary acylcarnitines (C2–C18). The performance of solvents with different elution efficiency and paper substrates with different porosity grade and structure were tested by use of spiked synthetic urine. Tandem mass spectrometry in multiple reaction monitoring (MRM) mode was optimized to obtain better specificity and sensitivity. Analyte signals were evaluated for stability and reproducibility. Calibration with [2H3]propionylcarnitine (C3-d3), [2H3]octanoylcarnitine (C8-d3), and [2H3] palmitoylcarnitine (C16-d3) as internal standards was used for quantification. Very good linearity was obtained, with correlation coefficients >0.99 for C0–C12 and C16 acylcarnitines and >0.96 for C14 and C18 acylcarnitines. Accuracy and precision (RSD, %) of the proposed procedure were tested at concentrations of 0.8, 8, and 20 mg L?1 with very satisfactory results: overall mean accuracy was 98.9 % and overall mean relative standard deviation 1 %. Limits of detection (LOD) between 6 and 208 μg L?1 for propionylcarnitine and tetradecanoylcarnitine, respectively, can be regarded as very satisfactory. Application of the method to real urine proved that paper spray tandem mass spectrometry is a simple, rapid, and direct tool (no derivatization is required) for assay of carnitine and C2–C12 acylcarnitines in urine.  相似文献   

5.
Tandem mass spectrometry (MS/MS) has become a prominent method for screening newborns for diseases such as organic acidemia and fatty acid oxidation defects, although current methods cannot separate acylcarnitine isomers. Accurate determination of dicarboxylic acylcarnitines such as methylmalonylcarnitine and glutarylcarnitine has not been carried out, because obtaining standards of these acylcarnitines is difficult. We attempted the individual determinations of acylcarnitines with isomers and dicarboxylic acylcarnitines by applying high-performance liquid chromatography (HPLC). Chromatographic separation was performed by gradient elution using a mixture of 0.08% aqueous ion-pairing agent and acetonitrile as the mobile phase. Mass transitions of m/z 161.8-->84.8 for carnitine and m/z 164.8-->84.8 for deuterated carnitine were monitored in positive ion electrospray ionization mode. One carnitine and 16 acylcarnitines were quantified. The limit of quantitation (LOQ) was 0.1 micromol/L for methylmalonylcarnitine and 0.05 micromol/L for the other acylcarnitines. Intra-day and inter-day coefficients of variance (CVs) were <8.3% and <8.8%, respectively, for all acylcarnitines in serum, and both were <9.2% in urine. Mean recoveries were >90% for all acylcarnitines. Human samples were quantified by this method. After addition of deuterated acylcarnitines as internal standards, acylcarnitines in serum or urine were extracted using a solid-phase extraction cartridge. In healthy adult individuals, isobutyryl-, 2-methylbutyryl- and isovalerylcarnitine were detected in serum and urine. Dicarboxylic acylcarnitines were detected in urine. High concentrations of methylmalonylcarnitine and propionylcarnitine were found in both the serum and the urine of a patient with methylmalonic acidemia. The described HPLC/MS/MS method could separate most acylcarnitine isomers and quantify them, potentially allowing detailed diagnoses and follow-up treatment for those diseases.  相似文献   

6.
基于琼脂糖水凝胶涂覆的纸基质,实现了纸喷雾离子化,建立了一种新的纸喷雾离子化质谱技术,直接分析生物流体样品。利用纸表面涂覆的水凝胶材料限制液滴的扩散,使互不相溶的喷雾溶剂液滴与生物样品液滴之间形成液液萃取,提高了检测灵敏度。同时通过限制液滴扩散,减少了喷雾溶剂挥发面积,降低了挥发速度,获得了时间更长的稳定质谱信号,可对生物流体样品中的低丰度药物快速、准确定量。相较于常规纸喷雾离子化,该方法喷雾时间延长近10倍,分析物信号提高近100倍,定量分析全血和尿液中的药物,检出限可降低7~33倍。方法材料制备简单,方便快捷,灵敏度高,在现场临床诊断上具有很大的应用潜力。  相似文献   

7.
Paper spray has been developed as a fast sampling ionization method for direct analysis of raw biological and chemical samples using mass spectrometry (MS). Quantitation of therapeutic drugs in blood samples at high accuracy has also been achieved using paper spray MS without traditional sample preparation or chromatographic separation. The paper spray ionization is a process integrated with a fast extraction of the analyte from the raw sample by a solvent, the transport of the extracted analytes on the paper, and a spray ionization at the tip of the paper substrate with a high voltage applied. In this study, the influence on the analytical performance by the solvent–substrate systems and the selection of the elution methods was investigated. The protein hemoglobin could be observed from fresh blood samples on silanized paper or from dried blood spots on silica-coated paper. The on-paper separation of the chemicals during the paper spray was characterized through the analysis of a mixture of the methyl violet 2B and methylene blue. The mode of applying the spray solvent was found to have a significant impact on the separation. The results in this study led to a better understanding of the analyte elution, on-paper separation, as well as the ionization processes of the paper spray. This study also helps in establishing a guideline for optimizing the analytical performance of paper spray for direct analysis of target analytes using mass spectrometry.  相似文献   

8.
Liquid chromatography tandem mass spectrometry methods were developed and validated to screen for and confirm residues of the thyreostatic drugs: tapazole, thiouracil, methylthiouracil, propylthiouracil, and phenylthiouracil in bovine and porcine urine and muscle tissues using dimethylthiouracil as internal standard. Thyreostats were extracted from urine samples with diethyl ether after derivatisation with 3-iodobenzylbromide in basic medium (pH 8.0) and analyzed by gradient elution on a Nucleosil C18 column with ion trap mass spectrometry detection using an electrospray source and triple quadrupole MS detection with turbo spray source. Thyreostats were extracted from muscle tissue with methanol, the denaturation of matrix protein was performed and then the same steps as for the urine samples were carried out. The methods were validated in accordance with the Commission Decision 2002/657/EC. Good thyreostats recoveries were obtained (from 82% to 117%) as well as acceptable within-lab reproducibility. The values of the decision limit CCα and the detection capability CCβ of five thyreostatic drugs are found to be below the recommended concentration set at 10 μg L(-1) (kg(-1)). The results of the validation demonstrate that liquid chromatography mass spectrometry with ion trap detection does not meet the criteria for confirmation for some thyreostats and therefore was applied for screening purpose only.  相似文献   

9.
Analysis of trace compounds in small-volume complex samples is of importance for forensic, clinical, pharmaceutical, environmental, and life science investigation. In this study, we reported the coupling of slug-flow microextraction with paper spray mass spectrometry for rapid analysis of trace analytes in small volume of complicated biological samples such as whole blood, milk, and body fluid, etc. The method is performed by applying a disposable glass capillary for rapid extraction of a small amount of complex samples using a small amount of organic solvent; the loaded organic solvent was then spotted onto a paper triangle and dried out; subsequently, a high voltage and some spray solvent were applied onto the paper triangle for mass spectrometric analysis. By using the proposed method, high sensitivity and satisfactory precision for quantitative analysis of trace macrolide antibiotics in whole bloods and milks as well as perfluorinated compounds in individual small organisms have been successfully achieved. In addition, investigation of bioaccumulation of perfluorinated compounds in individual small organisms has been reached.  相似文献   

10.
A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.  相似文献   

11.
A novel method is described for the extraction of methamphetamine, amphetamine, and methylenedioxyphenylalkylamine designer drugs, such as 3,4-methylenedioxy-methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxyethylamphetamine, N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine, and 3,4-(methylenedioxyphenyl)-2-butanamine, from human whole blood using molecularly imprinted solid-phase extraction as highly selective sample clean-up technique. Whole blood samples were diluted with 10 mmol/L ammonium acetate (pH 8.6) and applied to a SupelMIP-Amphetamine molecularly imprinted solid-phase extraction cartridge. The cartridge was then washed to eliminate interferences, and the amphetamines of interest were eluted with formic acid/methanol (1:100, v/v). After derivatization with trifluoroacetic anhydride, the analytes were quantified using gas chromatography-mass spectrometry. Recoveries of the seven amphetamines spiked into whole blood were 89.1-102%. The limits of quantification for each compound in 200 μL of whole blood were between 0.25 and 1.0 ng. The maximum intra- and inter-day coefficients of variation were 9.96 and 13.8%, respectively. The results show that methamphetamine, amphetamine, and methylenedioxyphenylalkyl-amine designer drugs can be efficiently extracted from crude biological samples such as whole blood by molecularly imprinted solid-phase extraction with good reproducibility. This extraction method will be useful for the pretreatment of human samples before gas chromatography-mass spectrometry.  相似文献   

12.
A rapid on-line solid phase extraction ultra high performance liquid chromatography tandem mass spectrometry method was developed for the identification and quantitation of nine perfluorinated compounds in matrices of environmental, biological and food interest. Pre-treatment, solid phase extraction, chromatographic and mass detection conditions were optimised, in order to apply the whole methodology to the analysis of different matrices. Particular attention was devoted to the evaluation of matrix effect and the correlated phenomena of ion enhancement or suppression in mass spectrometry detection. LOD and LOQ range from 3 to 15ngL(-1) and from 10 to 50ngL(-1), respectively. Method detection limits (MDLs) were also calculated for each kind of matrix. The recovery, evaluated for each analyte, does not depend on analyte concentration in the explored concentration range: average Rˉ% values are always greater than 82.9%. In the whole, the results obtained for samples of river waters, blood serum, blood plasma, and fish confirm the ubiquitous presence of perfluorinated compounds, as recently denounced by many sources.  相似文献   

13.
Herein we report the development of solid‐phase microextraction (SPME) devices designed to perform fast extraction/enrichment of target analytes present in small volumes of complex matrices (i.e. V≤10 μL). Micro‐sampling was performed with the use of etched metal tips coated with a thin layer of biocompatible nano‐structured polypyrrole (PPy), or by using coated blade spray (CBS) devices. These devices can be coupled either to liquid chromatography (LC), or directly to mass spectrometry (MS) via dedicated interfaces. The reported results demonstrated that the whole analytical procedure can be carried out within a few minutes with high sensitivity and quantitation precision, and can be used to sample from various biological matrices such as blood, urine, or Allium cepa L single‐cells.  相似文献   

14.
A method for the rapid screening and determination of amphetamine‐type designer drugs in saliva by a novel nib‐assisted paper spray‐mass spectrometry procedure is described. Under optimized conditions, the limit of detections for amphetamine derivatives (model samples: o‐, m‐, p‐chloroamphetamine and o‐, m‐, p‐fluoroamphetamine, respectively) were determined to 0.1 μg/mL by the nib‐assisted paper spray‐mass spectrometry method. This method is easier and has a higher sensitivity than similar methodologies, including atmospheric pressure/matrix‐assisted laser desorption ionization mass spectrometry and electrospray‐assisted laser desorption ionization/mass spectrometry. Data obtained using more classical separation methods, including liquid chromatography and capillary electrophoresis, are also reported.  相似文献   

15.
In expanded newborn screening programs by liquid chromatography/tandem mass spectrometry false negatives for tyrosinemia type I are a significant problem. We describe a method for inclusion of succinylacetone in order to avoid false negatives. We studied spots from 13,000 neonates born in Tuscany (January-May 2007) and ten spots from six patients with tyrosinemia type I. The traditional screening method was modified by adding dioxooctanoid acid (or 13C2-succinylacetone) as an internal standard to the methanolic solution of deuterated acylcarnitines and amino acids. A hydrazine solution was added to the mixture. The times of extraction, butylation and drying were only slightly prolonged. Specific multiple reaction monitoring for derivatized and labelled succinylacetone and dioxooctanoic acid was carried out. The assays were linear up to 100 micromol/L for succinylacetone. Intra- and inter-day imprecision data were in the range of 1.34% to 7.09% and 3.50% to 4.49%. Limits of detection and of quantification were 0.2 micromol/L and 0.4 micromol/L, respectively. Recovery ranged from 97.02% to 100.29%. Succinylacetone levels in samples from unaffected neonates were very close to the detection limit. Of the 46 recalls, eight (17.4%) were for abnormal tyrosine levels and all these cases had succinylacetone levels within the normal range (<2.4 micromol/L). In ten spots from six affected patients succinylacetone values ranged from 3.3 to 35.0 micromol/L. Including succinylacetone in newborn screening programs for amino acids and acylcarnitines avoids false-negative results for tyrosinemia type I. Newborn screening laboratories should consider implementing these modifications.  相似文献   

16.
A sonic spray ionization liquid chromatography/mass spectrometry (LC/SSI-MS) procedure combined with off-line solid-phase extraction was optimized for the analysis of 20 endocrine-disrupting chemicals (EDCs) in water samples. Method development included a comparison of the novel sonic spray ionization (SSI) with more traditional ion sources, i.e. pneumatically assisted electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). It was demonstrated that SSI and ESI spectra were very similar, but were more prone to the formation of solvent cluster ions as compared with APCI spectra. This phenomenon was most prominent for SSI and resulted in an increased chemical background in full-scan mass spectra. However, this chemical noise did not affect the overall sensitivity of SSI and ESI. After optimization of LC and MS parameters, the LC/SSI-MS method was validated. Recoveries ranged from 76.3 up to 113.4% for all compounds. Limits of detection (LOD) and quantitation (LOQ) were established between 3.0 and 11.5 ng/L and 9.9 and 38.0 ng/L, respectively. Within-day (n = 5) and between-day (n = 5) reproducibility were investigated at three levels and ranged from 3.3-16.5% and 7.6-19.2%, respectively. Eight-point calibration curves were established and showed linearity for all compounds (r(2) > 0.987) over a linear dynamic range of 10-10 000 ng/L.  相似文献   

17.
Preparation of electrochemically treated pencil graphite (ETPG) electrode and its application for the determination of DA in the presence of ascorbic (AA) and uric (UA) acids were investigated. Several important parameters were worked to control the performance of the ETPG electrode which showed a high selectivity and sensitivity toward DA. A linear relationship was obtained for dopamine (DA) over the concentration range of 0.01 and 5.0 μM with a detection limit of 0.31 nM in the presence of AA and UA. The fabrication reproducibility of the ETPG electrodes (n=10) showed an acceptable reproducibility with a RSD of 2.0% for 5.0 μM DA. The determination of DA in blood serum without any pretreatment and dilution has been reported for the first time in this work.  相似文献   

18.
Dried blood spot (DBS) samples are already successfully used in newborn screening and pharmacological analyses. The application of DBS matrix to further metabolomic methods will considerably extend the analytical options for the diagnostics of metabolic diseases. We present an MS/MS based method for the simultaneous extraction and quantification of 188 metabolites from dried blood spots. We provide a sensitive and reproducible method that adapts the AbsoluteIDQ? p180 kit of Biocrates to the DBS matrix for the quantification of metabolites of different substance classes including amino acids, biogenic amines, free carnitine, acylcarnitines, hexoses, glycerophospholipids, lysophosphatidylcholines, phosphatidylcholines, and sphingolipids.  相似文献   

19.
建立了同时测定纺织品中α-,β-,γ-六溴环十二烷的同位素稀释-超高效液相色谱-串联质谱分析方法.不同类型的纺织品样品采用加速溶剂萃取法,以正己烷-丙酮(体积比1∶1)混合液为萃取溶剂,在10.3 MPa和80℃下,静态循环萃取3次,每次5 min,萃取液经ENVI-CarbⅡ/PSA固相萃取柱净化,收集二氯甲烷-正己烷(体积比2∶3)洗脱液,采用Waters ACQUITY UPLC BEHPhenyl色谱柱(50 mm×2.1 mm,1.7μm),以甲醇-水为流动相梯度洗脱分离后进行UPLC/MS/MS多反应监测模式下的定性及定量分析.结果表明,α-,β-,γ-六溴环十二烷测定方法的定量限为0.5μg/kg,在0.5~10μg/kg浓度范围内,低、中及高3个添加水平的平均回收率为84.2%~93.7%,日内精密度均小于10%,日间精密度均小于12%.本方法准确快速,且灵敏度高,可用于纺织品的实际检验.  相似文献   

20.
Paper spray mass spectrometry is a method for the direct analysis of biofluid samples in which extraction of analytes from dried biofluid spots and electrospray ionization occur from the paper on which the dried sample is stored. We examined matrix effects in the analysis of small molecule drugs from urine, plasma, and whole blood. The general method was to spike stable isotope labeled analogs of each analyte into the spray solvent, while the analyte itself was in the dried biofluid. Intensity of the labeled analog is proportional to ionization efficiency, whereas the ratio of the analyte intensity to the labeled analog in the spray solvent is proportional to recovery. Ion suppression and recovery were found to be compound- and matrix-dependent. Highest levels of ion suppression were obtained for poor ionizers (e.g., analytes lacking basic aliphatic amine groups) in urine and approached –90%. Ion suppression was much lower or even absent for good ionizers (analytes with aliphatic amines) in dried blood spots. Recovery was generally highest in urine and lowest in blood. We also examined the effect of two experimental parameters on ion suppression and recovery: the spray solvent and the sample position (how far away from the paper tip the dried sample was spotted). Finally, the change in ion suppression and analyte elution as a function of time was examined by carrying out a paper spray analysis of dried plasma spots for 5 min by continually replenishing the spray solvent.
Graphical Abstract ?
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏