首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
Huang MF  Hsu CE  Tseng WL  Lin YC  Chang HT 《Electrophoresis》2001,22(11):2281-2290
Separations of phiX-174/HaeIII DNA restriction fragments have been performed in the presence of electroosmotic flow (EOF) using five different polymer solutions, including linear polyacrylamide (LPA), poly(ethylene oxide) (PEO), hydroxypropylcellulose (HPC), hydroxyethylcellulose (HEC), and agarose. During the separation, polymer solutions entered the capillary by EOF. When using LPA solutions, bulk EOF is small due to adsorption on the capillary wall. On the other hand, separation is faster and better for the large DNA fragments (> 872 base pairs, bp) using derivative celluloses and PEO solutions. Several approaches to optimum resolution and speed by controlling EOF and/or altering electrophoretic mobility of DNA have been developed, including (i) stepwise changes of ethidium bromide (0.5-5 microg/mL), (ii) voltage programming (125-375 V/cm), (iii) use of mixed polymer solutions, and (iv) use of high concentrations of Tris-borate (TB) buffers. The DNA fragments ranging from 434 to 653 bp that were not separated using 2% PEO (8,000,000) under isocratic conditions have been completely resolved by either stepwise changes of ethidium bromide or voltage programming. Compared to PEO solutions, mixed polymer solutions prepared from PEO and HEC provide higher resolving power. Using a capillary filled with 600 mM TB buffers, pH 10.0, high-speed (< 15 min) separation of DNA (pBR 322/HaeIII digest, pBR 328/ Bg/l digest and pBR 328/Hinfl digest) has been achieved in 1.5% PEO.  相似文献   

2.
DNA separations in the presence of electroosmotic flow (EOF) using poly(ethylene oxide) (PEO) solutions have been demonstrated. During the separations, PEO entered capillaries filled with Tris-borate (TB) free buffers by EOF and acted as sieving matrices. We have found that ionic strength and pH of polymer and free solutions affect the bulk EOF and resolution differently from that in capillary zone electrophoresis. The EOF coefficient increases with increasing ionic strength of the free TB buffers as a result of decreases in the adsorption of PEO molecules. In contrast, the bulk EOF decreases with increasing the ionic strength of polymer solutions using capillaries filled with high concentrations of free TB buffers. Although resolution values are high due to larger differential migration times between any two DNA fragments in a small bulk EOF using 10 mM TB buffers, use of a capillary filled with at least 100 mM TB free buffers is suggested for high-speed separations. On the side of PEO solutions, 1.5% PEO solutions prepared in 100 to 200 mM TB buffers are more proper in terms of resolution and speed. The separation of DNA markers V and VI was accomplished less than 29 min in 1.5% PEO solutions prepared in 100 mM TB buffers, pH 7.0 at 500 V/cm using a capillary filled with 10 mM free TB buffers, pH 7.0.  相似文献   

3.
Huang CC  Hsieh MM  Chiu TC  Lin YC  Chang HT 《Electrophoresis》2001,22(20):4328-4332
We report concentration and separation of DNA in the presence of electroosmotic flow (EOF) using poly(ethylene oxide) (PEO) solution. DNA fragments migrating against EOF stacked between the sample zone and PEO solution. To maximize the injection volume, several factors, such as concentrations of Tris-borate (TB) buffer and PEO solution, capillary size, and matrix, were carefully evaluated. The use of 25 mM TB buffers, pH 10.0, containing suitable amounts (less than 10 mM) of salts, such as sodium chloride, sodium phosphate, and sodium acetate, to prepare DNA is essential for the concentration of large-volume samples. In the presence of salts, the peaks also became sharper and the fluorescence intensity of DNA complexes increased. Using 2.5% PEO and a 150 microm capillary filled with 400 mM TB buffer, pH 10.0, up to 5 microL DNA samples (phiX 174 RF DNA-HaeIII digest or the mixture of pBR 322/HaeIII, pBR 328/Bg/I, and pBR 328/HinfI digests) have been analyzed, resulting in more than 400-fold improvements in the sensitivity compared to that by conventional injections (ca. 36 nL). Moreover, this method allows the analysis of 3.5 microL PCR products amplified after 17 cycles without any sample pretreatment.  相似文献   

4.
We have demonstrated on-line concentration and separation of DNA in the presence of electroosmotic flow (EOF) using poly(ethylene oxide) (PEO) solutions. After injecting large-volumes DNA samples, PEO solutions entered a capillary filled with 400 mM Tris-borate (TB) buffers by EOF and acted as sieving matrices. DNA fragments stacked between the sample zone and PEO solutions. Because sample matrixes affected PEO adsorption on the capillary wall, leading to changes in EOF, migration time, concentration, and resolving power varied with the injection length. When injecting phiX174 RF DNA-HaeIII digest prepared in 5 mM Tris-HCl buffer, pH 7.0, at 250 V/cm, peak height increased linearly as a function of injection volume up to 0.9 microl (injection time 150 s). The sensitivity improvement was 100-fold compare to that injected at 25 V/cm for 10 s (0.006 microl). When injecting 1.54 microl of GeneScan 1000 ROX, the sensitivity improvement was 265-fold. The sensitivity improvement was 40-fold when injecting 0.17 microl DNA sample containing pBR 322/HaeIII, pBR 328/BglI, and pBR 328/HinfI digests prepared in phosphate-buffered saline. This method allows the analysis of polymerase chain reaction (PCR) products amplified after 17 cycles when injecting 0.32 microl (at 30 cm height for 300 s). The total analysis time was shorter (91.6 min) than that (119.6 min) obtained from injecting PCR products after 32 cycles for 10 s.  相似文献   

5.
The impact of hexadecyltrimethylammonium bromide (CTAB) on the separation of ds-DNA by capillary electrophoresis in conjunction with laser-induced fluorescence (CE-LIF) detection using poly(ethylene oxide) (PEO) solution is described. The use of CTAB for improved separation reproducibility and efficiency of DNA has not been demonstrated although it is widely used for controlling the magnitude and direction of electroosmotic flow in CE. With increasing CTAB concentration, the interactions of DNA with ethidium bromide (EtBr) and with the capillary wall decrease. For the separation of DNA fragments with the sizes ranging from several base pairs (bp) to 2,176 bp, a polymer solution consisting of 0.75% poly(ethylene oxide), 100 mM TB buffer (pH 8.0), 25 microg/mL EtBr, and 0.36 microg/mL CTAB is proper. Using the PEO solution, we separated a mixture of DNA markers V (pBR 322/HaeIII digest) and VI (pBR 328/BglI digest and pBR 328/HinfI digest) within 8 min at -375 V/cm, with the limit of detection of 2.0 ng/mL based on the peak height for the 18-bp DNA fragment. The method is highly efficient (>10(6)plate/m), repeatable (RSD of the migration times <1.5%), and sensitive. In addition, it is convenient to fill a capillary (75 microm in diameter) with such a low-viscosity PEO solution by syringe pushing.  相似文献   

6.
Hsieh MM  Tseng WL  Chang HT 《Electrophoresis》2000,21(14):2904-2910
We demonstrated DNA preconcentration and separation in the presence of electroosmotic flow (EOF) using poly(ethylene oxide) (PEO) solutions. After injecting large volumes of DNA samples into a capillary filled with free tris(hydroxymethyl)aminomethane (Tris)-borate (TB) buffers, PEO solutions entered the capillary by EOF and acted as sieving matrices. In contrast to conventional methods (in the absence of EOF), controlling the EOF was also useful for resolution optimization. We have found that PEO adsorption on the capillary wall was more pronounced when low ionic strength buffers were used. Thus, the EOF decreased with increasing injection length, which led to longer migration times and changes in resolution and stacking efficiency. All resolution values were higher than 1.5 when 1.0 microg/mL DNA samples were injected at 240 V/cm for 60 s (0.67 microL). In addition, as low as 0.015 microg/mL DNA samples (an about 66-fold increase in sensitivity) were detected when the injection was performed at 250 V/cm for 60 s.  相似文献   

7.
Proteins were concentrated and separated in 0.6% poly(ethylene oxide) (PEO) solution using a capillary filled with Tris-borate (TB) buffer prior to analysis and detected by laser-induced native fluorescence using a pulsed Nd:YAG laser. During the concentration and separation, PEO solution entered the capillary by electroosmotic flow. When proteins dissolved in high salts (phosphate-buffered saline) were separated using 0.6% PEO solution prepared in 200 mM TB buffer, pH 9.0, the limits of detection (LODs) at signal-to noise ratios=3 for carbonic anhydrase (CA) and alpha-lactalbumin (alpha-lac) were on the levels of sub microM and microM, respectively. The LOD values compared to those obtained in 38 mM TB buffer were relatively high, which is likely due to salt quenching, Joule heating and poor stacking. To improve sensitivity for analysis of proteins in high-conductivity media, two on-line concentration approaches without desalting were developed. When using a capillary filled with 1.5 M TB buffer, pH 10.0, and PEO solution prepared in 800 mM TB buffer, pH 9.0, the LOD values for CA and alpha-lac were 13.8 nM and 126.0 nM, respectively, which were about 4.7 and 11.2-fold sensitivity enhancements compared to those obtained by a conventional hydrodynamic injection (30 cm height for 10 s), respectively. The sensitivity was further improved by injecting a short plug of low pH buffer after protein injection using a capillary filled with 1.5 M TB buffer, pH 10.0, and PEO solution prepared in 400 mM TB buffer, pH 9.0. A linear relationship between the peak height and the injection volume up to 0.81 microl was obtained and the LOD values for CA and alpha-lac were down to 4.7 and 37.8 nM.  相似文献   

8.
Hsieh MM  Chang PL  Chang HT 《Electrophoresis》2002,23(15):2388-2393
A partially filling technique for the analysis of DNA markers and polymerase chain reaction (PCR) products by capillary electrophoresis in the presence of electroosmotic flow using polymer solutions is presented. Either after or prior to the sample injection, a plug of salts at high pH was hydrodynamically injected. During the separation, poly(ethylene oxide) (PEO) solution entered the capillary. We have found that the position, length, and composition of the plugs affect the sensitivity, resolution, and speed on the analysis of PhiX-174/HaeIII DNA restriction fragments or a DNA mixture (pBR 322/HaeIII digest, pBR 328/BglI digest and pBR 328/HinfI digest) with different degrees. Through careful evaluation of the impact of anions and cations on the analysis of DNA, we have suggested that the optimal condition is applying a plug consisting of 32 mM NaCl and 0.01 M NaOH at 30 cm height for 60 s after sample injection. In the presence of such a plug, PEO adsorption reduces, and thus the separation is faster, as well as the sensitivity improves. Using this condition, the analysis of a DNA mixture (injected at 30 cm for 360 s) containing ten different PCR products amplified after 17 cycles was complete in 25 min. About a 2000-fold improvement in the sensitivity was achieved when compared to that by a conventional method (10 s injection) without applying a plug.  相似文献   

9.
This paper describes the analysis of large DNA fragments at pH > 10.0 by capillary electrophoresis (CE) in the presence of electroosmotic flow (EOF) using hydroxyethylcellulose (HEC) solution. HEC solution in the anodic reservoir enters the capillaries filled with high-pH buffer by EOF after sample injection. With respect to resolution, sensitivity, and speed, separation conducted under discontinuous conditions (different pH values of HEC solutions and buffer filling the capillary) is appropriate. Using HEC solution at concentrations higher than its entanglement threshold ensures a good separation of large DNA fragments in the presence of EOF at high pH. In addition to pH and HEC, the electrolyte species, dimethylamine, methylamine, and piperidine, play different roles in determining the resolution. The separation of DNA fragments ranging in size from 5 to 40 kilo base pairs was completed in 6 min using 1.5% HEC prepared in 20 mM methylamine-borate, pH 12.0, and the capillary filled with 40 mM dimethylamine-borate, pH 10.0. In comparison, this method allows faster separations of large DNA fragments compared with that conducted in the absence of EOF using dilute HEC solutions.  相似文献   

10.
This paper demonstrates the diagnosis of -thalassemia by capillary electrophoresis in conjunction with laser-induced fluorescence using poly(ethylene oxide) (PEO) solutions in the presence of electroosmotic flow (EOF). During the electrophoretic separation, PEO solution entered a capillary from the anodic vial by EOF. The separation of a mixture of the polymerase chain reaction (PCR) products (330 and 334 base pairs) from a healthy person and a -thalassemia patient was accomplished within 15 min at 15 kV using 1.5% PEO containing 2 M urea at 30 °C. The electropherogram patterns instead of migration times were used to diagnose -thalassemia, with an accuracy of 100% for the analyses of 11 blood samples from suspected patients. After injecting a large volume of the mixture to the capillary filled with 800 mM Tris-borate buffer (pH 10.0), the DNA fragments stacked due to increases in viscosity and sieving when migrating into 1.5% PEO solution. As a result of improved sensitivity, only 15 PCR cycles were required when using 500 ng of DNA templates. The results shown in this study indicate the potential of this simple, rapid, and cost-effective method for the diagnosis of -thalassemia.Abbreviations CE Capillary electrophoresis - EOF Electroosmotic flow - EtBr Ethidium bromide - LIF Laser-induced fluorescence - PCR Polymerase chain reaction - PEO Poly(ethylene oxide) - TRIS Tris(hydroxymethyl)aminomethane - TB TRIS-borate  相似文献   

11.
We describe simultaneous analysis of naphthalene-2,3-dicarboxaldehyde (NDA)-amino acid and NDA-biogenic amine derivatives by CE in conjunction with light-emitting diode-induced fluorescence detection using poly(ethylene oxide) (PEO) solutions containing sodium dodecyl sulfate (SDS). After sample injection, via EOF 0.1% PEO prepared in 100 mM TB solution (pH 9.0) containing 30 mM SDS entered a capillary filled with 0.5 M TB solution (pH 10.2) containing 40 mM SDS. Under this condition, 14 NDA-amino acid and NDA-amine derivatives were separated within 16 min, with high efficiency ((1.0–3.2) × 105 theoretical plates) and sensitivity (LODs at S/N = 3 ranging from 2.06 to 19.17 nM). In the presence of SDS and PEO, analytes adsorption on the capillary wall was suppressed, leading to high efficiency and reproducibility. The intraday analysis RSD values (n = 3) of the mobilities for the analytes are less than 0.52%. We have validated the practicality of this approach by quantitative determination of 9 amino acids in breast cancer cells (MCF-7) and 10 amino acids in normal epithelial cells (H184B5F5/M10). The concentrations of Tau and Gln in the MCF-7 cells were different than those in the H184B5F5/M10 cells, respectively. Our results show the potential of this approach for cancer study.  相似文献   

12.
13.
This paper describes a simple, sensitive, efficient, and rapid method for simultaneous analysis of biologically active amines and acids by capillary electrophoresis in conjunction with laser-induced native fluorescence detection (CE-LINF) using a diode pumped solid state nanolaser at 266 nm. In order to optimize resolution of the amines that were prepared in 10.0 mM formate-Tris (FT) solutions, 10.0 mM FT solutions with and without containing halides were used to fill the capillary and reservoirs, respectively. The electrophoretic mobilities of tryptamine (TA) and serotonin (5-HT) at pH 4.0 decrease with the increase in halide concentration (0-10.0 mM). Taken together with a great effect of iodide than other halides, we suggest that the formation of ion pairs is a main contributor for altering the migration of the amines. In order to simultaneously analyze the amines and their metabolites (acids) at low pH, a high bulk EOF is required. The analysis of 10 anlytes including amines and acids was completed within 12 min by CE-LINF using a capillary treated with 0.5M NaOH and then filled with 10.0 mM FT solutions (pH 4.0) containing 10.0 mM KCl prior to analysis. The limits of detection for TA and 5-hydroxyindole-3-acetic acid (5-HIAA) are 0.12 and 6.0 nM, respectively. The present method has been further validated by analyzing urine samples, with an RSD less than 3.1% (migration times) and 3.9% (concentration).  相似文献   

14.
This paper deals with dynamic coating of the microchannels fabricated on poly(methyl methacrylate) (PMMA) chips and DNA separation by microchip electrophoresis (MCE). After testing a number of polymers, including 2-hydroxyethyl cellulose, hydroxypropylmethyl cellulose, different sizes of poly(ethylene oxide) (PEO), and poly(vinyl pyrrolidone) (PVP), we found that coating of the PMMA microchannels with PEO(Mr = 6.0 x 10(5) g/mol) on the first layer is essential to minimize the interaction of DNA with PMMA surface. To achieve high efficiency, multilayer coating of PMMA chips with PEO, PVP, and PEO containing gold nanoparticles [PEO(GNP)] is important. A 2-(PEO-PVP)-PEO(GNP) PMMA chip, which was repeatedly coated with 1.0% PEO and 5.0% PVP twice, and then coated with 0.75% PEO(GNP) each for 30 min, provided a high efficiency (up to 1.7 x 10(6) plates/m) for the separation of DNA markers V (pBR 322/HaeIII digest) and VI (pBR 328/BgiI digest and pBR 328/HinfI digest) when using 0.75% PEO(GNP). With such a high efficiency, we demonstrated the separation of hsp65 gene fragments of Mycobacterium HaeIII digests by MCE within 90 s. The advantages of this approach to DNA analysis include ease of filling the microchannel with 0.75% PEO(GNP), rapidity, and reproducibility.  相似文献   

15.
Kuo IT  Chiu TC  Chang HT 《Electrophoresis》2003,24(19-20):3339-3347
We describe the separation of dsDNA by capillary electrophoresis in the presence of electroosmotic flow (EOF) using poly(ethylene oxide) (PEO). Using 1.0% PEO, the separation of DNA fragments with sizes ranging from 51 bp to 23 kbp has been achieved in less than 12 min, which is better than conventional methods (in the absence of EOF) in terms of speed and resolution. In order to concentrate and separate the DNA sample, gradient changes in the concentrations of PEO and ethidium bromide (EtBr) have been conducted. Different concentrations of PEO solutions are injected to the polyethylene tubes by pressure, where they enter the capillary by EOF. Because the large DNA fragments migrate faster towards the cathode end under counterflow conditions, the introduction sequence is from low to high concentrations of PEO solutions after sample injection. Using the gradient CE approach, the separations of the DNA sample injected at 30 cm height for times up to 120 s have been demonstrated. The linearity between injection time and peak height shows that the DNA fragments stacked during migration from the sample zone to PEO. We found that stacking efficiency is greater when the analysis was performed by simultaneously changing the PEO and EtBr concentration, compared to individual changes in PEO concentration.  相似文献   

16.
Chiu TC  Tu WC  Chang HT 《Electrophoresis》2008,29(2):433-440
We describe the stacking and separation of proteins by CE under discontinuous conditions in conjunction with light-emitting diode induced fluorescence (LEDIF) detection using a violet LED at 405 nm. The proteins were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) to form NDA-protein derivatives prior to CE-LEDIF analysis. During the separation, poly(ethylene oxide) (PEO) solution containing CTAB enters from the cathodic inlet to the capillary via electroosomotic flow (EOF). The optimum conditions are: the capillary was filled with 50 mM glycine buffer (pH 9.0) containing 1.0 mM CTAB, NDA-protein derivatives were prepared in deionized water containing 1.0 mM CTAB, and 0.6% PEO was prepared in 50 mM glycine (pH 9.0) containing 2.0 mM CTAB. The analysis of four NDA-protein derivatives is fast (<3 min), with RSD <1.5% in terms of migration time. In order to improve the sensitivity of NDA-protein derivatives, a stacking approach based on increases in viscosity and electric field, as well as sieving was applied. The efficient stacking approach provides LODs (S/N = 3) of 2.41, 0.59, 0.61, and 4.22 nM for trypsin inhibitor, HSA, beta-lactoglobulin, and lysozyme, respectively. In addition, we also applied the stacking approach to determination of the concentration of HSA in one urine sample, which was determined to be 0.31 +/- 0.05 microM (n = 3).  相似文献   

17.
Chen JL  Lu TL  Lin YC 《Electrophoresis》2010,31(19):3217-3226
A new phase containing immobilized carbon nanotubes (CNTs) was synthesized by in situ polymerization of acid-treated multi-walled CNTs using butylmethacrylate (BMA) as the monomer and ethylene dimethacrylate as the crosslinker on a silanized capillary, forming a porous-layered open-tubular column for CEC. Incorporation of CNT nanomaterials into a polymer matrix could increase the phase ratio and take advantage of the easy preparation of an OT-CEC column. The completed BMA-CNT column was characterized by SEM, ATR-IR, and EOF measurements, varying the pH and the added volume organic modifier. In the multi-walled CNTs structure, carboxylate groups were the major ionizable ligands on the phase surface exerting the EOF having electroosmotic mobility, 4.0 × 10(4) cm2 V(-1)1 S(-1)1, in the phosphate buffer at pH 2.8 and RSD values (n=5), 3.2, 4.1, and 4.3%, for three replicate capillaries at pH 7.6. Application of the BMA-CNT column in CEC separations of various samples, including nucleobases, nucleosides, flavonoids, and phenolic acids, proved satisfactory upon optimization of the running buffers. Their optima were found in the borate buffers at pH 9.0/50 mM, pH 9.5/10 mM/50% v/v ACN, and pH 9.5/30 mM/10% v/v methanol, respectively. The separations could also be used to assess the relative contributions of electrophoresis and chromatography to the CEC mechanism by calculating the corresponding velocity and retention factors. Discussions about interactions between the probe solutes and the bonded phase included the π-π interactions, electrostatic repulsion, and hydrogen bonding. Furthermore, a reversed-phase mode was discovered to be involved in the chromatographic retention.  相似文献   

18.
A new approach for the analysis of large-volume naphthalene-2,3-dicarboxaldehyde (NDA) derivatives of amino acids by micellar electrokinetic chromatography (MEKC) in conjunction with a purple light-emitting diode-induced fluorescence detection is described. In order to optimize resolution, speed, and stacking efficiency, a discontinuous condition is essential for the analysis of NDA-amino acid derivatives. The optimum conditions use 2.0M TB (pH 10.0) buffer containing 40mM sodium dodecyl sulfate (SDS) to fill the capillary, deionized water to dilute samples, and 200mM TB (pH 9.0) containing 10mM SDS to prepare 0.6% poly(ethylene oxide) (PEO). Once high voltage is applied, PEO solution enters the capillary via electroosmotic flow and SDS micelles interact and thus sweep the NDA-amino acid derivatives having smaller electrophoretic mobilities than that of SDS micelles in the sample zone. When the aggregates between SDS micelles and NDA amino acid derivatives enter PEO zone, they are stacked due to decrease in electric field and increases in viscosity. Under the optimum conditions, the concentration and separation of 0.53-microL 13 NDA-amino acid derivatives that are negatively charged has been demonstrated by using a 60-cm capillary, with the efficiencies 0.3-9.0x10(5) theoretical plates and the LODs at signal-to-noise ratio 3 ranging from 0.30 to 2.76nM. When compared to standard injection (30-cm height for 10s), the approach allows the sensitivity enhancements over the range of 50-800 folds for the derivatives. The new approach has been applied to the analysis of a red wine sample, with great linearity of fluorescent intensity against concentrations (R(2)>0.98) and the RSD (three repetitive runs in one day) values of the migration times for the ten identified amino acids less than 2.8%.  相似文献   

19.
A novel pH‐responsive coating technique was developed and applied to CE successfully in this paper. The coating was formed by bonding mixed opposite charge poly(acrylic acid) and poly(2‐vinylpyridine) randomly onto the inner wall of a silica capillary. The coating processes were first characterized by ellipsometry and atomic force microscopy at macroscale and microscale, respectively. Measurements of EOF were implemented to confirm the coating. Direction and velocity of EOF became controllable from negative to positive, showing a perfect sigmoidal curve as the coating net charges alternated by the pH of BGE. The control of the EOF makes it possible to analyze different kinds of small molecules, peptides, and proteins successfully in the same capillary. Results showed that the stability and reproducibility for separations of fluoroquinolone standards were satisfactory for more than a hundred separations. A series of basic and acidic protein standards were separated with admirable efficiency and minimal adsorption using both polarities. The separation of tryptic BSA digest showed that the prepared capillary has immense potential in analyzing a single sample with both acidic and basic separations, which achieved the expectation in proteomics study by CE‐MS.  相似文献   

20.
In this study, positively charged alkylaminosilyl monomers were used to modify the inner surface of fused silica capillaries, which subsequently were employed in capillary electrophoresis (CE) and capillary electrochromatography (CEC). The obtained surfaces yield a reversed electroosmotic flow (EOF) and have varying carbon chain lengths, that interact with the analytes and give chromatographic retention. The coating procedure is very simple and fast. The performance of the modified capillaries was evaluated regarding pH influence on EOF and chromatographic interactions. The experiments were conducted with UV and mass spectrometry (MS) and applied to the separation of various neuropeptides. The derivatized surfaces showed a linear (R(2) approximately 0.99) pH dependence with isoelectric points (pI) at 8.6-8.8. Rapid separations of peptide standards and a protein digest with efficiencies as high as 5 x 10(5) plates/m were performed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号