首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Hu W  Haddad PR  Hasebe K  Tanaka K 《The Analyst》2001,126(5):555-558
An ion chromatographic (IC) method based on the use of titrant (strong acid) as the stationary phase was developed for simultaneous determination of total alkalinity (TA) and monovalent cations. The titrant used in this study was obtained by initially loading lithium dodecylsulfate (Li-DS) onto a reversed-phase material and then conditioning the column with a slightly acidified aqueous LiCl solution (a mixture of 50.0 mM LiCl and 0.1 mM H2SO4). When a small amount of a basic sample was injected onto a column prepared in this way, the basic species (Bn-) reacted predominantly with H+ on the stationary phase and the reaction with the eluent phase was negligible due to the very low concentration of eluent H+ (in the eluent, a molar ratio of [Li+]/[H+] = 250:1 applied). The stationary phase H+ consumed in the acid-base reaction was then re-supplied by H+ from the eluent. By monitoring the conductance of the eluent using conductivity, an induced peak resulting from the basic species was observed. Calibration graphs of peak areas vs. molar concentration of the basic species for OH-, HCO3- and H2PO4- were found to be identical. CO3(2-), HPO4(2-), and B4O7(2-) also gave identical calibration curves but their slope values were twice those for HCO3-. The detection limit for HCO3- was less than 3.2 microM and the calibration curve was linear up to 12.3 mM (injection volume, 100 microL). Seawater was directly analyzed and its total alkalinity was found to be 2.87 mM (RSD 0.53%, n = 5), which was in good agreement with the result of 2.88 mM (RSD 3.2%, n = 5) obtained using auto-potentiometric titration. Na+ and K+ were determined simultaneously and the concentrations were 481.6 and 10.6 mM, respectively.  相似文献   

2.
W Hu  K Hasebe  A Iles  K Tanaka 《Analytical sciences》2001,17(12):1401-1404
A unified ion chromatographic (IC) system was developed for the determination of acidity or alkalinity. Separation column used was a reversed-phase ODS packed column, which had been modified by saturating it with lithium dodecylsulfate. A slightly acidified LiCl (50 mM LiCl and 0.05 mM H2SO4) aqueous solution was used as the eluent. By conditioning the separation column in this way, both H+ and Li+ ions became bound to the stationary phase. Dodecylsulfate groups with Li+ counterions acted as cation-exchange sites for the separation of hydrogen ions (free acidity determination). The remaining dodecylsulfate groups, with H+ counterions acted as a titrant, which reacted with basic species (total alkalinity determination). The acidity or alkalinity of each sample was measured according to the change in conductance from the eluent baseline level. A positive peak was observed from those samples with a free acidity greater than their total alkalinity, due to the separation/elution of free H+ ions. A negative peak was observed from those samples with a free acidity less than their total alkalinity. This was due to an equivalent amount of eluent H+ ions being re-supplied to the stationary phase while the "solid titrant" consumed by the acid-base reaction was regenerated. The retention time for the peak corresponding to the acidity or alkalinity was governed by the retention time for H+ ions in this IC system. Samples with a free acidity greater than 2.25 microM (tested by determination of H+ ions in pure water in equilibrium with atmospheric CO2) could be analyzed by this method. A very similar detection level was obtained for alkalinity (tested by analyzing standard aqueous NaHCO3 solutions). Aqueous solutions of some strong-acid/strong-base inorganic salts were found to be slightly alkaline. This was measured as a percentage, relative to an NaHCO3 solution at the same concentration. Solutions of NaClO4, Na2SO4, NaI, NaNO3, and NaCl, gave comparative alkalinity values of 8.75%, 1.83%, 0.42%, 0.35%, and 0.33%, respectively.  相似文献   

3.
The high-speed determination of hydrogen, magnesium and calcium ions by ion chromatography (IC) is demonstrated on a monolithic octadecyl-boned silica (ODS) column coated with lithium dodecylsulfate (Li-DS). This stationary phase, when used in conjunction with a 2 mM ethylenediamine and 0.1 mM Li-DS solution as eluent at pH 6.0, was found to be suitable for the rapid and efficient separation of hydrogen and magnesium and calcium in the order H+ < Mg2+ < Ca2+ within 4 min at a flow rate of 4.0 ml/min. Under the conditions, linear calibration plots of conductivity versus concentration were obtained for the cations over about three orders of magnitude, and the detection limits were 1 microM for H+, 2 microM for Mg2+ and Ca2+. Rainwater was analyzed directly using this IC system with satisfactory results.  相似文献   

4.
W Hu  K Hasebe  A Iles  K Tanaka 《The Analyst》2001,126(6):821-824
An ion chromatographic (IC) method was developed for the high-resolution determination of a sample's free hydrogen ion concentration (H+). Highly purified lithium dodecyl sulfate was used as the stationary phase, a slightly acidified aqueous LiCl solution was used as the mobile phase and conductivity was used for analyte detection. An electrical double layer (EDL) containing H+ was established on the stationary phase by using a slightly acidified electrolyte solution as the eluent. H+ in the EDL protonated any weak acid groups (i.e., silanols) on the stationary phase so that H+ from the sample could be retained/separated purely by dodecyl sulfate. The optimum molar ratio of H+:Li+ in the EDL for this IC system was obtained by using an aqueous solution containing 40.0 mM LiCl and 0.07 mM H2SO4 as the eluent. After separation, H+ was detected by direct conductimetric measurement. An H+ detection limit of better than 8.2 x 10(-6) M was obtained from the analysis of standard aqueous H2SO4 solutions. Other monovalent cations could also be separated with this method, giving detection limits of 7.4 x 10(-5), 4.3 x 10(-5) and 4.2 x 10(-5) M for Na+, NH4+ and K+, respectively. The method was applied to the simultaneous determination of H+, Na+, NH4+ and K+ in acid rain. The results obtained showed a significant improvement in reproducibility when compared with those from a conventional pH-meter. Acid rain samples with a pH < 5 could be analyzed with this IC system.  相似文献   

5.
Hu W  Hasebe K  Tanaka K  Inoue S  Nagai M 《The Analyst》2000,125(12):2160-2162
The hydronium ion (H3O+), the most essential species to every field of chemistry, was successfully separated from other cations. This major goal was achieved by a HPLC approach in which a reversed-phase ODS which had been initially modified with dodecylsulfate was used as the stationary phase and an aqueous KNO3 solution was used as the mobile phase. Of all tested monovalent cations (analyte ions), the hydronium ion (H3O+) showed the highest affinity towards the stationary phase, followed by NH4+, Na+, and then Li+. The hydronium ion, after the separation, was directly detected using conductivity and the detection signal (conductivity) was in linear proportion (linear range 7.8 x 10(-4)-0.45 M; injection volume, 100 microL) to the concentration of the acid species of the tested sample. This proposed HPLC method was applicable to separate/detect H3O+ from both strong and weak acidic samples.  相似文献   

6.
An ion chromatographic (IC) method is reported for simultaneous determination of total acidity (H+), Ba2+, Ca2+, and Mg2+ in aqueous samples. A standard ODS silica column modified by coating with n-hexadecylphosphocholine was used as the separation column. Water alone was used as the eluent, with conductivity detection of the sample ions. An excess of sodium iodide was added to each sample so that both H+ and divalent cations were always eluted with iodide as the counterion. The elution order was Ba2+, Mg2+, Ca2+, and H+ with H+ being eluted much later than the divalent cations. Acetic acid and several other weak acids could also be separated because all the protons were transposed from acetic acid (HAc) to HI by the sodium iodide. Detection limits for 100 microl injection, S/N=3 were in the low micromolar range for the divalent cations and approximately 0.3 mM for H+/I-. This method was used successfully for simultaneous determination of total acidity, magnesium and calcium in HCl-type of hot-spring water.  相似文献   

7.
A monolithic ODS-silica gel column modified by saturating it with lithium dodecylsulfate (Li-DS) was used to demonstrate the high-speed separation of H+ from other mono- and divalent cations, such as Na+, NH4+, K+, Mg2+ and Ca2+ using ion chromatography (IC). Using a 5 mM EDTA-2K solution containing 0.10 mM Li-DS (pH 4.80) as eluent, H+ was eluted with a sharp and symmetrical peak within 1.0 min before other cations at a flow-rate of 1.5 ml min(-1). The rapid elution of H+ and its conductimetric detection could be attributed to the presence of EDTA (HY2-), which can convert H+ ions as anions. i.e. H(+) + H2Y(2-) --> H3Y(-). The acidity of rainwater and deionized water samples was determined using this IC system with satisfactory results.  相似文献   

8.
We introduced an approach to the ion chromatographic determination of common mono- and divalent cations including hydrogen ion and demonstrated the ability of a C30 column dynamically coated first with dodecylsulfate and then with 18-crown-6 ether to separate the cations by ion-exchange mechanism. Using an ethylenediamine solution containing a small concentration of 18-crown-6 ether and lithium dodecylsulfate at pH 6.2 as eluent, the cations were eluted in the order Li < Na+ < NH4+ < H+ < K+ < Mg2+ < Ca2+ with symmetrical peaks. The conductivity vs. concentration plots were linear about three orders of magnitude, from millimolar to micromolar; and the detection limits were all < 0.6 microM. Rainwater was analyzed directly using this ion chromatographic system with satisfactory results.  相似文献   

9.
Arai K  Mori M  Hironaga T  Itabashi H  Tanaka K 《色谱》2012,30(4):404-408
A combination of hydrophilic interaction chromatographic(HILIC) column and a weakly acidic cation-exchange resin(WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography(IC).Firstly,the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions.The columns used were SeQuant ZIC-HILIC(ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase(ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase(HILIC-10).When using tartaric acid as the eluent,the HILIC columns indicated strong retentions for anions,based on ion-pair interaction.Especially,HILIC-10 could strongly retain anions compared with ZIC-HILIC.The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I-> NO-3 > Br-> Cl-> H2PO-4.However,since HILIC-10 could not separate analyte cations,a WCX column(TSKgel Super IC-A/C) was connected after the HILIC column in series.The combination column system of HILIC and WCX columns could successfully separate ten ions(Na+,NH+4,K+,Mg2+,Ca2+,H2PO-4,Cl-,Br-,NO-3 and I-) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6.The relative standard deviations(RSDs) of analyte ions by the system were in the ranges of 0.02%-0.05% in retention times and 0.18%-5.3% in peak areas through three-time successive injections.The limits of detection at signal-to-noise ratio of 3 were 0.24-0.30 μmol/L for the cations and 0.31-1.2 μmol/L for the anions.This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results.  相似文献   

10.
The application of laboratory-made aluminium-adsorbing silica gel (Al-Silica) as a cation-exchange stationary phase to ion chromatography-indirect photometric detection (IC-IPD) for common mono- and divalent cations (Li+, Na+, NH+, K+, Mg2+ and Ca2+) was carried out by using protonated tyramine (4-aminoethylphenol) as eluent ion. When using 1.2 mM tyramine-0.2 mM oxalic acid at pH 4.5 as eluent, incomplete separation of the monovalent cations and complete separation of the divalent cations were achieved in 17 min. Then, the addition of crown ethers in the eluent was carried out for the complete separation of the mono- and divalent cations. As a result, when using 1.2 mM tyramine--0.2 mM oxalic acid at pH 4.5 containing either 5 mM 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane) or 0.5 mM and 18-crown-6 (1,4,7,10,13,16-hexaoxacyclooctadecane) as eluent, excellently simultaneous separation of these cations was achieved in 21 min. The proposed IC-IPD was successfully applied to the determination of major cations in natural water samples.  相似文献   

11.
New stationary phases for chromatographic separation of anions, obtained by loading liposomes made from dimyristolyphosphatidylcholine (DMPC) onto reversed-phase packed columns (C18 and C30) are reported. Mono- and divalent anions were used as model analyte ions and retention data for these species were obtained using the DMPC stationary phases and used to elucidate the separation mechanisms involved in this chromatographic system. The DMPC stationary phases can separate anions by either a solvation-dependent mechanism or an electrostatic ion-exchange mechanism, depending upon the relative magnitudes of the negative electrostatic potential (Psi(-)) of the phosphate moiety (P-) and the positive electrostatic potential (Psi(+)) of the quaternary ammonium groups (N+) on the headgroup of DMPC. If Psi(+) > Psi(-), such as in case where Psi(-) has been reduced either by binding of eluent cations (e.g., H+ or divalent cations) onto the P- group of DMPC or by steric screening when a C30 reversed-phase material was used to support the DMPC, then the overall electrostatic surface potential (and hence also the effective anion-exchange capacity) was generally large and the anions were separated on the basis of an electrostatic mechanism. However, if Psi(+) was similar to Psi(-), such as in the case of using a C18 reversed-phase support and monovalent cations as eluent cations, then the overall electrostatic surface potential and the effective anion-exchange capacity were very small and the analyte anions were separated on the basis of a solvation-dependent mechanism. The DMPC stationary phases were found to be suitable for the direct determination of iodide and thiocyanate in highly saline water samples, such as seawater samples.  相似文献   

12.
An ion chromatographic (IC) method has been developed for determination of hydrogen ion (H+). It is based on the use of sulfonated cation-exchange resin as stationary phase, aqueous ethylenediamine-N,N,N',N'-tetraacetic acid (dipotassium salt, EDTA-2K, written as K2H2Y) solution as mobile phase, and conductivity for detection. H+ was separated mainly by cation-exchange, but its elution was accelerated by the presence of EDTA. The order of elution for the model cations was H+ > Li+ > Na+ > NH4+ > Ca2+ > > Mg2+. A sharp and highly symmetrical peak was obtained for H+ and this was attributed to the capacity of H2Y2(2-) to receive and bind H+. H+ was detected conductiometrically and detector response (reduction in conductivity as a result of H+ +H2Y2- --> H3Y-) was linearly proportional to the concentration of H+ in the sample. The detection limit for H+ with this IC system was better than 4.7 micromol L(-1). A significant advantage of this method was the ability to separate and determine, in one step, H+ and other cations. The successful determination of H+ and other cation species in real acid-rain samples demonstrated the usefulness of this method.  相似文献   

13.
Influence of acidic eluent on retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography (ion-exclusion/CEC) were investigated on a weakly acidic cation-exchange resin in the H(+)-form with conductivity. Sensitivities of analyte ions, especially weak acid anions (F(-) and HCOO(-)), were affected with degree of background conductivity level with pK(a1) (first dissociation constant) of acid in eluent. The retention behaviors of anions and cations were related to that of elution dip induced after eluting acid to separation column and injecting analyte sample. These results were largely dependent on the natures of acid as eluent. Through this study, succinic acid as the eluent was suitable for simultaneous separation of strong acid anions (SO(4)(2-), Cl(-), NO(3)(-) and I(-)), weak acid anions (F(-), HCOO(-) and CH(3)COO(-)), and cations (Na(+), K(+), NH(4)(+), Mg(2+) and Ca(2+)). The separation was achieved in 20 min under the optimum eluent condition, 20 mM succinic acid/2 mM 18-crown-6. Detection limits at S/N=3 ranged from 0.10 to 0.51 microM for strong acid anions, 0.20 to 5.04 microM for weak acid anions and 0.75 to 1.72 microM for cations. The relative standard deviations of peak areas in the repeated chromatographic runs (n=10) were in the range of 1.1-2.9% for anions and 1.8-4.5% for cations. This method was successfully applied to hot spring water containing strong acid anions, weak acid anions and cations, with satisfactory results.  相似文献   

14.
The method for analysis of inorganic cations in brine solutions was developed. Ion chromatography is a well-established and accepted technique in the determination of a variety of inorganic ions. However, there are significant complications when ion chromatography is used to determine trace concentrations of inorganic ions in brine matrices. The brine solution in our study was made to simulate the solution from the Waste Isolation Pilot Plant. Instrumental parameters such as eluent composition, flow-rates, and sample loop volumes were investigated to arrive at the optimum condition for the determination of the cations with minimal dilution. Separation was carried out in a Dionex CG12A/CS12A with 8.25 mM H2SO4 as eluent at 1.2 ml/min flow-rate. Our results indicated that ion chromatography is an accurate and a good alternative method for the analysis of cations in brine solution.  相似文献   

15.
The retention behaviour of alkaline earth cations was studied as a function of changing composition of acidified ethylenediamine eluent. The multiple eluent species retention model developed for separation of calcium, magnesium and strontium ions was utilized for determination of selectivity coefficients for sample and eluent ions. The suggested model accurately describes and predicts retention of analytes under elution conditions [0.5-2.0 mM C2H4(NH2)2 and pH 4-6] which are of practical importance. The results in three-dimensional retention surface with species distribution graphs are demonstrated. Complexometric titrations and ion chromatography (IC) were compared for the analysis of calcium and magnesium ions. Statistical data indicated that there was no evidence for relative differences between the two methods. However, IC gives several advantages over volumetric method.  相似文献   

16.
The retention and separation selectivity of inorganic anions and on-column derivatised negatively charged citrate or oxalate metal complexes on reversed-phase stationary phases dynamically coated with N-(dodecyl-N,N-dimethylammonio)undecanoate (DDMAU) has been investigated. The retention mechanism for the metal-citrate complexes was predominantly anion exchange, although the amphoteric/zwitterionic nature of the stationary phase coating undoubtedly also contributed to the unusual separation selectivity shown. A mixture of 10 inorganic anions and metal cations was achieved using a 20 cm monolithic DDMAU modified column and a 1 mM citrate eluent, pH 4.0, flow rate equal to 0.8 mL/min. Selectivity was found to be strongly pH dependent, allowing additional scope for manipulation of solute retention, and thus application to complex samples. This is illustrated with the analysis of an acidic mine drainage sample with a range of inorganic anions and transition metal cations, varying significantly in their concentrations levels.  相似文献   

17.
Basic operation principles of a lightweight, low power, low cost, portable ion chromatograph utilizing open tubular ion chromatography in capillary columns coated with multi-layer polymeric stationary phases are demonstrated. A minimalistic configuration of a portable IC instrument was developed that does not require any chromatographic eluent delivery system, nor sample injection device as it uses gravity-based eluent flow and hydrodynamic sample injection adopted from capillary electrophoresis. As a detection device, an inexpensive commercially available capacitance sensor is used that has been shown to be a suitable substitute for contactless conductivity detection in capillary separation systems. The built-in temperature sensor allows for baseline drift correction typically encountered in conductivity/capacitance measurements without thermostating device. The whole instrument does not require any power supply for its operation, except the detection and data acquisition part that is provided by a USB port of a Netbook computer. It is extremely lightweight, its total weight including the Netbook computer is less than 2.5 kg and it can be continuously operated for more than 8 h. Several parameters of the instrument, such as detection cell design, eluent delivery systems and data treatment were optimized as well as the composition of eluent for non-suppressed ion chromatographic analysis of common inorganic cations (Na+, NH4+, K+, Cs+, Ca2+, Mg2+, transition metals). Low conductivity eluents based on weakly complexing organic acids such as tartaric, oxalic or pyridine-2,6-dicarboxylic acids were used with contactless capacitance detection for simultaneous separation of mono- and divalent cations. Separation of Na+ and NH4+ cations was optimized by addition of 18-crown-6 to the eluent. The best separation of 6 metal cations commonly present in various environmental samples was accomplished in less than 30 min using a 1.75 mM pyridine-2,6-dicarboxylic acid and 3 mM 18-crown-6 eluent with excellent repeatability (below 2%) and detection limits in the low micromolar range. The analysis of field samples is demonstrated; the concentrations of common inorganic cations in river water, mineral water and snow samples were determined.  相似文献   

18.
Guo H  Chu C  Li Y  Yang B  Liang X 《The Analyst》2011,136(24):5302-5307
Ion chromatography (IC) is one of the most powerful analysis technologies for the determination of charged compounds. A novel click lysine stationary phase was prepared via Cu(I) catalyzed alkyne-azide 1,3-dipolar cycloaddition (CuAAC) and applied to the analysis of inorganic ions. The chromatographic evaluation demonstrated good performance (e.g. the plate number of thiocyanate is ~50,000 plates m(-1)) and effective separation ability for the common inorganic anions with aqueous Na(2)SO(4) eluent. The separation mechanism was observed to be mainly dominated by ion exchange interaction. The retention of these analytes is highly dependent on the pH value of eluent. Compared with the lysine stationary phase prepared via the conventional manner, the click lysine exchanger demonstrated shorter retention time and better ion separation characteristics under the same chromatographic conditions, which is a great advantage for rapid separation and analysis of inorganic ions.  相似文献   

19.
The unusual selectivity of a methylene succinic (itaconic) acid modified polymeric column was investigated for the separation of alkali, alkaline earth, transition and heavy metals employing non-chelating inorganic eluents. The retention of selected metal ions on the column was investigated with simple HNO3 eluents and eluents prepared from KNO3 and KCl salts of varying pH (adjusted using HNO3). From these studies both the effect of eluent ionic strength and pH upon retention was evaluated for the itaconic acid stationary phase. The results obtained showed that despite slow exchange kinetics causing poor efficiencies, acceptable baseline separations of selected alkaline earth and transitions could be obtained under optimum conditions (the baseline separation of Mg(II), Ca(II), Mn(II), Cd(II), Zn(II) and Co(II) was possible using a 15 mM KNO3-5 mM KCl eluent at pH 3.50 in under 25 min). The use of an simple ionic strength step gradient was shown that facilitated the addition of Pb(II) to the above group of metal ions. An investigation into the effect of temperature upon peak efficiency and retention showed increased column temperature could be used to improve the resolution of closely eluting metal ions such as Ca(II) and Sr(II) and Ca(II) and Mn(II).  相似文献   

20.
Ion-exclusion/cation-exchange chromatography with an eluent containing the bile salt-type zwitterionic surfactant CHAPS was performed in order to evaluate variations in anion (SO(4)(2-), NO(3)(-), and SCN(-)) and cation (Na(+), K(+), NH(4)(+), Mg(2+), and Ca(2+)) concentrations in human saliva. CHAPS prevents the adsorption of proteins to the stationary phase, i.e., weakly acidic cation-exchange resin, since it aggregates proteins without denaturing them. Addition of 1mM CHAPS to the eluent comprising 6mM tartaric acid and 7 mM 18-crown-6 yielded reproducible separations of anions and cations in protein-containing saliva. The resolutions of anions and cations were not significantly affected by the addition of CHAPS to the eluent. The concentrations of Na(+) and K(+) varied before and after meals; or that of SCN(-), upon smoking. The relative standard deviations of peak areas ranged from 0.3 to 5.1% in 1 day (n=20) and from 1.4 to 5.8% over 6 days (n=6).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号