1.
Comprehensive two-dimensional (2D) HPLC in the reversed-phase liquid chromatography (RPLC) mode using C18 silica monolith columns at first dimension (1st-D) (10 cm x 4.6mm I.D.) and second dimension (2nd-D) (5 cm x 4.6mm I.D.) was carried out successfully. A mixture of water and tetrahydrofuran (THF) was used as a mobile phase in the 1st-D separation, and a mixture of water and methanol (CH3OH) in the 2nd-D separation. Sample fractions from 1st-D column were directly loaded into an injection loop of the 2nd-D HPLC equipped with two injector valves for one column. The fractionation time at the 1st-D that was equal to the separation time at the 2nd-D was 45 or 60s. Total peak capacity up to 900 was obtained in about 60 min for the isocratic mode separation of aromatic compounds in this system. Gradient elution mode applied to both 1st-D and 2nd-D separations resulted in shorter separation time and better separation efficiencies than the isocratic mode. It was demonstrated that 2D-HPLC systems employing popular C18 stationary phases with different organic modifiers in mobile phases for each dimension could produce large peak capacity. The different selectivities were provided by the difference in polar interactions between a solute and the organic modifier existing in the stationary phase.  相似文献   

2.
The development of a two-dimensional liquid chromatographic system requires a process of assessment that can yield an optimum performing system with minimal experimental evaluation. Information Theory and a geometric approach to Factor Analysis are two techniques that when used in combination, provide important information on the expected two-dimensional performance. In the present study, we compare the predicted separation performance of two-dimensional systems that have been subjected to analysis by Information Theory and Factor Analysis to that of actual chromatographic separation performance. Our test separation comprised a mixture of 32 oligostyrene structural isomers and stereoisomers. The optimal combination as determined by Information Theory and Factor Analysis consisted of a C18 column with a methanol mobile phase in the first dimension and a carbon clad zirconia column with an acetonitrile mobile phase in the second dimension. This system was also shown to be the most successful practical system when a heart-cutting approach was employed. The practical results were in total agreement with the results from Information Theory and Factor Analysis. The number of isomers resolved using this system was 27. A second system, namely one comprising of a C18 column and methanol mobile phase in the first dimension and a carbon clad zirconia column with a methanol mobile phase in the second dimension was also predicted to be a system with high separation potential. However, practical assessment of this system did not realise the theoretical predictions, largely due to the long separation times required in the second dimension. Furthermore, all combinations that employed a C18 column with an acetonitrile mobile phase in the first dimension failed to realise the theoretical separation potential due to high solute crowding, low orthogonality and a disordered arrangement of bands along the first separation axis. This was also predicted by the theoretical assessment.  相似文献   

3.
A comprehensive two-dimensional reversed-phase reversed-phase liquid chromatographic system for the separation of a complex mixture of oligostyrenes was developed using results from a previous theoretical assessment of the informational similarity, percent synentropy, orthogonality and peak capacity of hypothetically coupled systems. The degree of sample attribute order in the first separation dimension was also used in the development of the experimental two-dimensional system. A C18(methanol)/CCZ(acetonitrile) two-dimensional system was chosen for the comprehensive analysis of the oligostyrene mixtures because this system had the lowest solute crowding, highest orthogonality and was observed to have order with respect to a sample attribute in the first separation dimension. The separations achieved were in full agreement with the results from information theory and (a geometric approach to) factor analysis assessments. High sampling rates in the first liquid chromatographic dimension were shown to be impossible or inefficient when the peak capacity and separation time of the second dimension was high or when the aim of the exercise was to isolate individual sample constituents in high yield.  相似文献   

4.
An orthogonal (71.9%) off‐line preparative two‐dimensional normal‐phase liquid chromatography/reversed‐phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self‐made Click TE‐Cys (60 μm) solid‐phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE‐Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co‐eluted in the first dimension were selected for further purification using reversed‐phase liquid chromatography. Multiple compounds could be isolated from one normal‐phase fraction and some compounds with bad resolution in one‐dimensional liquid chromatography could be prepared in this two‐dimensional system owing to the orthogonal separation. Moreover, this two‐dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off‐line two‐dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice.  相似文献   

5.
The separation selectivity of octadecyl-silica (C18) and of bonded pentafluorophenylpropyl-silica (F5) and PEG-silica columns was compared for natural phenolic antioxidants. The separation selectivities for phenolic antioxidants on C18 and F5 columns are strongly correlated, but low selectivity correlation indicating strong differences in the retention mechanism was observed between the C18 and PEG columns. Hence, the combination of a C18 and a PEG column is useful for separation of phenolic antioxidants that are not fully separated on single columns. Two-dimensional comprehensive liquid chromatography using a short PEG-silica column in the first dimension and a conventional C18-silica in the second dimension has the advantage of on-column focusing of the fractions transferred onto the C18 column in the second dimension, as a weaker mobile phase is used in the first dimension than in the second dimension. However, a stop-flow set-up in the first dimension system is necessary after the transfer of each fraction to the second dimension. Peak capacity is considerably larger but the separation time is much longer than with serially coupled PEG and C18 columns, which were employed for separation of beer and hop extract samples in connection with coulometric detection.  相似文献   

6.
Many samples contain compounds with various numbers of two or more regular structural groups. Such "multidimensional" samples (according to the Giddings' notation) are best separated in orthogonal chromatographic systems with different selectivities for the individual repeat structural groups, described by separation factors. Correlations between the repeat group selectivities characterize the degree of orthogonality and suitability of chromatographic systems for two-dimensional (2D) separations of two-dimensional samples. The range of the structural units in that can be resolved in a given time can be predicted on the basis of a model describing the repeat group selectivity in the first- and second-dimension systems. Two-dimensional liquid chromatographic system combining reversed-phase (RP) mode in the first dimension and normal-phase (NP) mode in the second dimension were studied with respect to the possibilities of in-line fraction transfer between the two modes. Hydrophilic interaction liquid chromatography (HILIC) with an aminopropyl silica column (APS) is more resistant than classical non-aqueous NP systems against adsorbent desactivation with aqueous solvents transferred in the fractions from the first, RP dimension to the second dimension. Hence, HILIC is useful as a second-dimension separation system for comprehensive RP-NP LCxLC. A comprehensive 2D RP-NP HPLC method was developed for comprehensive 2D separation of ethylene oxide-propylene oxide (EO-PO) (co)oligomers. The first-dimension RP system employed a 120 min gradient of acetonitrile in water on a C18 microbore column at the flow-rate of 10 microL/min. In the second dimension, isocratic HILIC NP with ethanol-dichloromethane-water mobile phase on an aminopropyl silica column at 0.5 mL/min was used. Ten microliter fractions were transferred from the RP to the HILIC NP system at 1 min switching valve cycle frequency.  相似文献   

7.
Various combinations of PEG-silica, phenyl-silica and C18 columns in a single-column or serial (tandem) arrangement in the first dimension and a monolithic Chromolith column in the second dimension were tested for comprehensive two-dimensional (2D) LCxLC separation of phenolic and flavone natural antioxidants. The combinations of different stationary phase chemistries provided low selectivity correlations between the first-dimension and the second-dimension separation systems. Improvement in system orthogonality, bandwidths suppression, more regular band distribution over the whole 2D retention plane and increased peak capacity in different 2D setups was achieved by using gradients with matching profiles running in parallel in the two dimensions over the whole 2D separation time range. Instead of two sampling loops, two alternating trapping XTerra columns were used for sample fraction transfer from the first-dimension column to the second dimension. Stronger retention on the XTerra columns in comparison to PEG-silica or phenyl-silica columns in the first dimension allowed using focusing of sample fractions in narrow zones on the top of a trapping column and back-flushing into the second dimension in a very low volume of the mobile phase. This fraction transfer modulation provided significant bandwidth suppression in the second dimension. 2D systems with optimized stationary phase selectivity, parallel gradients and fraction transfer modulation using two trapping columns were applied for the analysis of natural antioxidants in beer and wine samples.  相似文献   

8.
Two‐dimensional liquid chromatography largely increases the number of separated compounds in a single run, theoretically up to the product of the peaks separated in each dimension on the columns with different selectivities. On‐line coupling of a reversed‐phase column with an aqueous normal‐phase (hydrophilic interaction liquid chromatography) column yields orthogonal systems with high peak capacities. Fast on‐line two‐dimensional liquid chromatography needs a capillary or micro‐bore column providing low‐volume effluent fractions transferred to a short efficient second‐dimension column for separation at a high mobile phase flow rate. We prepared polymethacrylate zwitterionic monolithic micro‐columns in fused silica capillaries with structurally different dimethacrylate cross‐linkers. The columns provide dual retention mechanism (hydrophilic interaction and reversed‐phase). Setting the mobile phase composition allows adjusting the separation selectivity for various polar substance classes. Coupling on‐line an organic polymer monolithic capillary column in the first dimension with a short silica‐based monolithic column in the second dimension provides two‐dimensional liquid chromatography systems with high peak capacities. The silica monolithic C18 columns provide higher separation efficiency than the particle‐packed columns at the flow rates as high as 5 mL/min used in the second dimension. Decreasing the diameter of the silica monolithic columns allows using a higher flow rate at the maximum operation pressure and lower fraction volumes transferred from the first, hydrophilic interaction dimension, into the second, reversed‐phase mode, avoiding the mobile phase compatibility issues, improving the resolution, increasing the peak capacity, and the peak production rate.  相似文献   

9.
High-performance centrifugal partition chromatography (HPCPC) has been successfully applied to the separation of four protoberberine quaternary alkaloids, namely palmatine, jatrorrhizine, columbamine and pseudocolumbamine, from a methanolic extract (M1, 1.47 g) of Enantia chlorantha Oliver stem bark. For their isolation, two successive biphasic solvent systems composed of dichloromethane-methanol-water (48:16:36, v/v) were selected. The aqueous-rich phase was the stationary phase and the organic-rich phase was the mobile phase. The first system, containing potassium perchlorate, allowed to isolate 600 mg of palmatine, and to obtain 146 mg of a mixture (M2) containing only jatrorrhizine, columbamine and pseudocolumbamine. The second biphasic system, prepared with water alkalinized with sodium hydroxide, was employed to isolate the M2 components. This system applied to the purification of 70 mg of M2 allowed to obtain 16 mg ofjatrorrhizine and 13 mg of columbamine. To obtain pseudocolumbamine (16 mg), the elution mode was reversed, the aqueous-rich phase becoming the mobile phase, and the organic-rich phase becoming the stationary one. Analytical reversed-phase high-performance liquid chromatography, NMR, high-resolution mass spectrometry and UV spectrometry were used to verify the identity and the purity of the isolated compounds.  相似文献   

10.
The retention behavior of low- and high-molecular-mass poly(ethylene oxide) (PEO) in reversed-phase (RP) and normal-phase (NP) liquid chromatography was investigated. In RPLC using a C18 bonded silica stationary phase and an acetonitrile-water mixture mobile phase, the sorption process of PEO to the stationary phase showed deltaH(o) > 0 and deltaS(o) > 0. Therefore, PEO retention in RPLC separation is an energetically unfavorable, entropy-driven process, which results in an increase of PEO retention as the temperature increases. In addition, at the enthalpy-entropy compensation point the elution volume of PEO was very different from the column void volume. These observations are quite different from the RPLC retention behavior of many organic polymers. The peculiar retention behavior of PEO in RPLC separation can be understood in terms of the hydrophobic interaction of this class of typical amphiphilic compounds with the non-polar stationary phase, on the one hand, and with the aqueous mobile phase, on the other. The entropy gain due to the release of the solvated water molecules from the PEO chain and the stationary phase is believed to be responsible for the entropy-driven separation process. On the other hand, in NPLC using an amino-bonded silica stationary phase and an acetonitrile-water mixture mobile phase, PEO showed normal enthalpy-driven retention behavior: deltaH(o) < 0 and deltaS(o) < 0, with the retention decreasing with increasing temperature and PEO eluting near the column void volume at the enthalpy-entropy compensation point. Therefore, high-resolution temperature gradient NPLC separation of high-molecular-mass PEO samples can be achieved with relative ease. The molecular mass distribution of high-molecular-mass PEO was found to be much narrower than that measured by size-exclusion chromatography.  相似文献   

11.
Summary A novel bonded phase for reversed-phase HPLC was synthesized in two steps. Octylamine was first reacted with β-(3,4-epoxycyclohexyl)ethyltrimethoxysilane (β-ECTS) and then the intermediate product was coupled onto porous silica. The prepared packing was characterized by elemental analysis, solid-state13C NMR and Fourier transform infrared (FT-IR). Chromatographic evaluations were carried out by using a mixture of organic compounds including acidic, basic and neutral analytes and methanol-water as binary mobile phase. The results showed that the stationary phase has excellent chromatographic properties and is resistant to hydrolysis between pH=2≈8. It can be used efficiently for the separation of basic compounds.  相似文献   

12.
System peaks are important but often also disturbing phenomena occurring in separation systems. Behavior of system peaks was studied in reversed phase high performance liquid chromatography (RP HPLC) systems consisting of an RP Amide C16 column and aqueous solutions of organic acids with alkaline metal hydroxides as mobile phases. Binary mobile phases, composed of benzoic acid and lithium hydroxide (LiOH) or cesium hydroxide (CsOH), yielded two system peaks. The first peak was stationary and the second one moved with dilution of the mobile phase or with changes of the alkaline metal hydroxide concentration. The latter changes affected dissociation of the benzoic acid present in the mobile phase and thereby its retention. The presumption that the first system peak is not influenced by the type of alkaline metal cation and that it is related to the non‐adsorbed component of the mobile phase was confirmed by a cyclic procedure. Three‐component mobile phases composed of benzoic acid, tropic acid, and a hydroxide gave rise to three system peaks as expected. The first peak was again stationary and the two others shifted depending on the concentration variation of both acids. Resonance causing a zigzag peak, well described in capillary zone electrophoresis (CZE), was observed if 1‐pentanol was injected into a chromatographic system with one‐component mobile phase.  相似文献   

13.
李笃信  魏远隆  宋伦  李彤  杜一平  张维冰 《化学学报》2009,67(21):2481-2485
在二维液相色谱中, 第二维的分离速度是制约其发展的重要因素. 升高色谱柱温度可以有效降低流动相粘度, 加快溶质在两相间的传质速率, 有效加快分析速度. 以离子交换色谱法(WAX)为第一维分离模式和反相色谱法(RP)为第二维分离模式, 十通阀和两个捕集柱为接口, 通过将第二维色谱柱温度升高到80 ℃和提高流量到3 mL/min, 构建了高温WAX/RP二维液相色谱系统. 以4种标准蛋白的酶解物为样品评价系统的分离性能, 第一维共有33个馏分被捕集并导入到第二维分析, 高温二维液相色谱系统识别出187个色谱峰.  相似文献   

14.
A simple preparation process of alkylamide phase for reversed-phase HPLC (RP-HPLC) is described. The process includes aminopropyltrimethoxysilane firstly reacted with octanoyl chloride, then the intermediate was coupled onto porous silica. The resultant bonded silica has a reproducible ligand surface concentration and homogenous bonded ligand distribution on the porous silica. Characterization of prepared packing was carried out with elemental analysis, solid-state 13C NMR and Fourier transform infrared (FT-IR). Chromatographic evaluations were carried out by using a mixture of organic compounds including acidic, basic and neutral analytes under methanol/water as binary mobile phase. The results showed that the stationary phase have excellent chromatographic properties and can be efficiently used for the separation of basic compounds.  相似文献   

15.
The separation of C60 and C70 fullerenes on four different polysiloxane stationary phases was examined. It was determined that polar solvents can be used as mobile phases effectively for the separation of fullerene molecules. Unlike previously published work, a polymeric octadecyl siloxane (ODS) stationary phase provided higher separation factors for C70/C60 than did monomeric ODS stationary phases or phenyl substituted stationary phases. For example, for a methanol-diethyl ether (50:50, v/v) mobile phase and C60, k' approximately 5.0 separation factors, alpha = 3.3, were achieved with polymeric ODS compared to alpha = 2.2, with a monomeric ODS stationary phase. A linear solvation energy relationship (LSER) was used to model the importance of solvent interactions and stationary phase interaction to solute retention.  相似文献   

16.
The resolving power of four reversed-phase-reversed-phase two-dimensional (2D) chromatographic systems was evaluated using information theory (IT) and a geometric approach to factor analysis. The first separation dimension employed a C18 column, while the second separation dimension employed a carbon clad zirconia column. Mobile phases in each dimension were either methanol or acetonitrile. The sample matrix that was employed in this study contained a mixture of 58 components, comprised of stereoisomers and structural isomers of a systematic variation in molecular weight. Each of the components were oligostyrenes, with between two and five configurational repeating units having either n-butyl, sec-butyl or tert-butyl end groups. In the two-dimensional systems employed in this study, between 46 and 49 of the 58 components could be separated, depending on the mobile phase combinations--with apparent resolution that could not possibly be achieved in a single one-dimensional separation. The results from this study indicate that in order to fully evaluate the resolving power of a 2D system multiple methods of analysis that evaluate the separation potential are most appropriate. This becomes increasingly important when the sample contains components that are very closely related and the retention of solutes displays a high degree of solute crowding.  相似文献   

17.
Summary A recently-developed octadecyl-bonded alumina (ODA) stationary phase was evaluated for the separation of peptides and proteins by reversed phase high performance liquid chromatography. Using standard water-acetonitrile mobile phase gradients containing 0.1 % trifluoroacetic acid, the average peak capacity obtained for the separation of a mixture of ribonuclease a, cytochrome c, lysozyme and carbonic anhydrase on an ODA column are similar to that obtained on a widely used octadecylsilane (ODS) column. However, overall chromatographic resolution of the components of this mixture on ODA is inferior to that obtained on ODS. Cytochrome c peak areas were found to be 50% smaller on the ODA column than on ODS. On the other hand, both peak capacities and resolutions of octapeptide mixtures were found to be generally superior on the ODA column, and peak areas for a representative octapeptide were found to be virtually identical for both ODA and ODS columns. The differences in the results obtained on the ODA and ODS columns for these separations are attributed to the smaller pore size and unique fused-microplatelet shape of the ODA particles. Comparisons of the separations of the tryptic digest of cytochrome c on the ODS and ODA columns demonstrate that the ODA phase is potentially as useful as ODS for peptide mapping applications.  相似文献   

18.
An online high‐pH reversed‐phase liquid chromatography× low‐pH reversed‐phase liquid chromatography tandem electrospray ionization mass spectrometry combined with pulse elution gradient in the first dimension was constructed to separate and identify alkaloids from Macleaya cordata (willd.) R. Br. The modulation was performed by using a dual second dimensional columns interface combined with a make‐up dilution pump, which is responsible for dilution and neutralization of the first dimensional effluent, and the dual second dimensional columns integrated the trapping and the separation function to reduce the second dimension system dead volume. Taking advantage of the dissociable characteristics of alkaloids, mobile phases with different pH values were applied in the first dimension (pH 9.0) and the second dimension (pH 2.6) to improve the orthogonality of two‐dimension separation. Besides, the pulse elution gradient in first dimension and second dimensional gradient were carefully optimized and much better separation was achieved compared to the separation with the traditional two‐dimensional liquid chromatography approach. Finally, mass measurement was performed for alkaloids in M. cordata (willd.) R. Br. by coupling proposed two‐dimensional liquid chromatography system with triple quadrupole mass spectrometry, and 39 alkaloids were successfully identified by comparing the obtained result with the former reported results.  相似文献   

19.
In this paper a phenyl-carbamate-propyl-β-cyclodextrin stationary phase was employed for the enantioseparation of several flavonoids, including flavanones and methoxyflavanones by using nano-liquid chromatography (nano-LC). The same stationary phase was also used for the diastereoisomeric separation of two flavanone glycosides. The compounds: flavanone, 2′-hydroxyflavanone, 4′-hydroxyflavanone, 6-hydroxyflavanone, 7-hydroxyflavanone, 4′-methoxyflavanone, 6-methoxyflavanone, 7-methoxyflavanone, hesperetin, hesperidin, naringenin and naringin were studied using reversed, polar organic and normal elution modes. The effect of the nature and composition of the mobile phase (organic modifier type, buffer and water content in the reversed phase mode) on the enantioresolution (Rs), retention factor (k) and enantioselectivity (α) were investigated. Baseline resolution of all studied flavonoids, with the exception of 2′-hydroxyflavanone and naringin, was achieved in reversed phase mode using a mixture of MeOH/H2O at different ratios as mobile phase. Good results, in terms of peak efficiency and short analysis time, were obtained adding 1% triethylammonium acetate pH 4.5 buffer to MeOH/H2O mixture. The separation of the studied compounds was also performed in polar organic mode. By using 100% of MeOH as mobile phase, the resolution was achieved for the studied analytes, except for 7-hydroxyflavanone, 2′-hydroxyflavanone, naringenin, hesperidin and naringin. Normal mode was tested employing a mixture of EtOH/hexane/TFA as mobile phase achieving the enantiomeric and diastereomeric separation of only hesperetin and hesperidin, respectively. The use of nano-LC technique for the resolution of flavanones optical isomers allowed to achieve good resolutions in shorter analysis time compared to the results reported in literature with conventional HPLC.  相似文献   

20.
The chromatographic behavior of 8 ionic liquids - 7 homologues of 1-alkyl-3-methylimidazolium and 4-methyl-N-butylpyridinium - has been investigated with a strong cation exchange adsorbent. In particular, the dependence of the retention properties of these solutes on mobile phase composition, pH, and buffer concentration was evaluated with the aim of optimizing and improving the selectivity and retention of solute separation. While using the SCX stationary phase, several interactions occurred with varying strengths, depending on the mobile phase composition. Cation exchange, nonspecific hydrophobic interactions, and adsorption chromatography behavior were observed. Reversed phase chromatography occurred at low concentrations of acetonitrile, electrostatic and adsorption interactions at higher organic modifier concentrations. Elevated buffer concentrations lowered the retention factors without affecting the selectivity of ionic liquids. Obtained results were further compared to the chromatographic behaviour of ionic liquids in the reversed phase system. All analyzed ionic liquids follow reversed-phase behavior while being separated. Much lower selectivity in the range of highly hydrophilic compounds is obtained. This suggests preferred use of ion chromatography for separation and analysis of compounds below 4 carbon atoms in the alkyl side chain.  相似文献   