首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Summary A gas chromatographic methodology with selective detection is presented for the analysis in wines and corks of pentachlorophenol residues, which are suspected to be the most likely precursors of some off-flavours described in several wine samples. After derivatisation, pentachlorophenol acetate residues were monitored by electrolytic conductivity detection and/or mass spectrometric detection in the selective ion mode at m/z 264 and 266. Recoveries varied from 80 to 96% for wine samples fortified with 5 to 100 g l–1 and from 83 to 91% for corks (fortified at 25 to 100 g kg–1). The proposed methodology allowed for a determination limit of g l–1 for wine and 10 g kg–1 for corks.  相似文献   

2.
Nanometer-sized l-cysteine-capped ZnS particles have been synthesized and used as a fluorescence probe to investigate the effect of proteins on fluorescent intensity. With =190 nm, maximum and constant synchronous fluorescence enhancement was produced at 267 nm and pH 5.12 in the presence of proteins. A highly sensitive synchronous fluorescence method for the rapid determination of proteins has been developed. Under optimum conditions, calibration graphs are linear over the range 0.03–8.0 g mL–1 for bovine serum albumin (BSA), 0.01–6.0 g mL–1 for human serum albumin (HSA), 0.05–8.0 g mL–1 for -globulin (-G), and 0.04–4.0 g mL–1 for ovalbumin, respectively. The relative standard deviations of seven replicate measurements were 1.75% for 1.0 g mL–1 BSA, 1.90% for 1.0 g mL–1 HSA, 1.65% for 1.0 g mL–1 -G, and 2.32% for 1.0 g mL–1 ovalbumin.  相似文献   

3.
The determination of trace metals, e.g. Bi, Cd, Pb, in high-purity aluminium, zinc and commercial steel by flame or graphite furnace atomic absorption spectrometry following their preconcentrations as iodo complexes on XAD-1180 resin by means of a short column system is described. The recoveries are quantitative (95%). The relative standard deviations varies between 6% and 10%. The relative errors are less than 8% in a concentration range of 1 × 10–3 –4 × 10–5%. Detection limits for flame AAS and GFAAS were in the ranges of 0.002–0.110 g/ml and 0.0003–0.004 g/ml or in the ranges of 0.08–4.40 g/g and 0.012–0.16 g/g with respect to the solid samples, respectively.  相似文献   

4.
Arsenic in sea water was determined directly by graphite furnace atomic absorption spectrometry (GFAAS) using palladium nitrate as chemical modifier, at an optimum concentration of 15 mg l–1. Deuterium and Zeeman effect background correction were compared and gave detection limits of 0.6 and 0.8 g l–1, respectively. Precisions between 8 and 2%, for both correctors, were obtained with an injection volume of 40 l. The accuracy obtained with different reference materials: CRM-403 (1.461 g kg–1), NASS-4 (1.26 ±0.09 gl–1) and IAEA/W-4 (24–31 g l–1) was studied for large injection volumes for both background correction systems. Interferences by chloride, sodium, potassium, calcium and silicon were removed by Zeeman correction, whereas deuterium correction was much less effective and was insufficiently accurate for sea water samples.  相似文献   

5.
Summary In natural waters, heavy metals such as Cd may be present in bound form. It is, therefore, important to consider chemical speciation, especially at low concentrations of the metal where a significant part can be bound by other trace constituents so tightly that it escapes several forms of its determination. It has been demonstrated that even the very strong complexant APDC is unable to leach out all of the heavy metal present in several coastal water samples from the German Bight.This paper describes a new micro method for the determination of total Cd in natural waters. First a small sample is dried in a polypropylene vial. Then the salt residue is heated to 90° C with a mixture of sulphuric and nitric acid for digestion of organic trace constituents (and oxidation of sulphides if present). After dilution subsamples are neutralized using an excess of NaHCO3 buffer solution. Extraction results are then independent from the possible slight variations of pH. The extractant, a solution of APDC in CCl4 is stable for weeks, and even the extract is stable for at least 16h. Precision is in the range of 7% at a concentration of 0.066 g Cd l–1; the detection limit is below 0.002 g l–1 and can be lowered, if necessary, by enlargement of the original sample. According to the sensitivity of the method the typical blank of 0.022 g Cd l–1 is high, but it is rather constant (mean variation from the mean: 0.0024 g l–1).Teil XI: Fresenius Z. Anal. Chem. 299, 206–207 (1979)  相似文献   

6.
The formation of nucleic acids/8-hydroxyquinoline/yttrium(III) ternary complexes and their fluorescent properties have been studied. The nucleic acids studied include native and thermally denatured calf thymus DNA, fish sperm DNA and yeast RNA. In the range of pH 7.6–8.5, controlled by NH3-NH4C1 buffer, ternary complexes are formed that fluoresce at different wavelengths with different nucleic acids. Based on the fluorescence reactions, sensitive spectrofluorimetric methods for nucleic acids are proposed. In optimal conditions, the calibration curves were linear in the range 0.5–4.0 gml–1 for calf thymus DNA, 0.5–2.5 g ml–1 for fish sperm DNA and 0.5–4.0 g ml–1 for yeast RNA. The limits of determination (3 ) were 0.030 g ml–1 for calf thymus DNA, 0.020 g ml–1 for fish sperm DNA and 0.090 g ml–1 for yeast RNA. Corresponding to the interferences of coexisting substances, six synthetic samples were constructed and the results of determination were satisfactory.  相似文献   

7.
A method for the determination of aldrin, dieldrin, DDT, DDE, and DDD contamination in animal fats (beef tallow, lard, and chicken fat) without using toxic reagents is developed, that uses high-performance liquid chromatography after the sample has been prepared by matrix solid-phase dispersion (MSPD) with acidic alumina oxide. A reversed-phase C1-silica column with a mobile phase of 50% (v/v) ethanol solution (in water) and a photo-diode array detector were used for the determination. Average recoveries of the target compounds (0.2–5.0 g g–1) ranged from 84–98%, with coefficients of variation of <5%. The limits of quantitation were 0.16 g g–1 for AD, 0.10 g g–1 for DD, 0.06 g g–1 for DDT, 0.07 g g–1 for DDE, and 0.05 g g–1 for DDD. No toxic reagents were used at all.  相似文献   

8.
This paper presents a new method for the determination of Hg(II) in waters, using indirect spectrophotometric measurements of the Hg(II) dithizone complex. The reagent is a mixture of dithizone, CDTA (1,2-cyclohexylene-dinitrilo-tetraacetic acid), thiourea, ethylic alcohol and glycine. Sensitivity and working range are 0.4 g · l–1 and 2–100 g · l–1, respectively. A comparison of the results with those of the cold-vapor atomic absorption spectrometry shows a good correlation for different samples revealing only small interferences. The new method is well suited for on-line measurements, easy to run and has low cost equipment.  相似文献   

9.
Some modifications of the stannous chloride reduction method for the estimation of inorganic phosphate reported by Berenblum-Chain are suggested. By this method, it is possible to measure 25 g l–1 of phosphorus /P/ as inorganic phosphate in the presence of macromolecules like deoxyribonucleic acid /100 g ml–1/, as compared to 200 g l–1 of P by the original method. If a larger sample volume /30 ml/ is used, even 5 g l–1 of P can be measured.  相似文献   

10.
Zusammenfassung Eine neue Methode zur Durchführung gravimetrischer Bestimmungen im Mikrogrammbereich wurde beschrieben; diese beruht im wesentlichen darauf, daß der Niederschlag nicht mehr zusammen mit dem Filter, sondern nach Überführen mit einem geeigneten Lösungsmittel in einem separaten Wägegefäß gewogen wird.Die dazu nötigen Geräte und deren Herstellung wurden beschrieben. Nach dieser Methode wurden folgende Bestimmungen mit zufriedenstellender Richtigkeit durchgeführt: 2,5–25g Al, 5–50g Cu und 5–50g Zn mit Oxin, 2,5–25g Fe(III) und 2,5–25g Ti(IV) mit N-Benzoyl-phenylhydroxylamin, 5–50g Ni und 5–50g Cu mit Salicylaldoxim, 2,5–50g Co(II) und 2,5–50g Fe(III) mit -Nitroso--naphthol sowie 5–50g Chlorid als Silberchlorid.
Precipitation analysis in the microgram-scale: A new method
Summary A new method for gravimetric determinations in the microgram-scale is described. This method is based on the fact that the precipitate is not weighed together with the filter but is transferred to a separate weighingvessel using a suitable solvent. The necessary simple devices and their use are described. The following determinations were carried out with satisfying accuracy: 2,5–25g Al, 5–50g Cu and 5–50g Zn with Oxine, 2,5–25g Fe and 2,5–25g Ti withN-benzoylphenylhydroxylamine, 5–50g Ni and 5–50g Cu with salicylaldoxime, 2,52–50g Co and 2,5–50g Fe with -nitroso--naphthol and 5–50g chloride as silver chloride.
  相似文献   

11.
The optimum conditions for the extractive spectrophotometric determination of dioxouranium(VI) with hexamethyleneiminecarbodithioate(HMICdt) have been established. Dioxouranium(VI) reacts with this ligand at pH 4.5 to form a yellowish-orange uncharged 12 metal-ligand complex which can be extracted by chloroform. The calibration graph was linear in the range of 1–20 g ml–1 of dioxouranium(VI) at 335 nm. The molar absorptivity of the extracted species is 5.952×103 l mol–1 cm–1 with Sandell's sensitivity of 0.04 g cm–2. The average of 10 determinations of dioxouranium was 49.75 g for the samples containing 50 g of U(VI) and the variation from the mean at 95% confidence limit was 49.75±0.5955.  相似文献   

12.
Summary The reducing fusion gas extraction method has been used for the determination of nitrogen in uranium metal and uranium dioxide reference materials at levels of about 10–15g·g–1. It has been found that when extracting at temperatures above 2700° C the use of a platinum flux is no longer necessary. Pure nitrogen and nitrogen-helium mixtures were used for calibrating the detection unit in the range of 1.5–670 g. The calibration of the extraction was performed with metallic reference materials in the range of 8–331 g N2 content.
Bestimmung von Stickstoff in Uran und Uranoxid durch Hochtemperatur-Gasextraktion
Zusammenfassung Die Gasextraktion aus reduzierender Schmelze wurde zur Stickstoffbestimmung in Uranmetall- und Urandioxid-Referenzmaterialien bei Gehalten von 10–15 g·g–1 angewendet. Bei Temperaturen über 2700° C ist kein Platinbad mehr erforderlich. Zur Eichung der Detektionseinheit im Bereich von 1,5–670 g wurden reiner Stickstoff oder Stickstoff-Helium-Mischungen benutzt. Zur Eichung der Extraktion wurden metallische Referenzmaterialien mit (8–331g) N2 eingesetzt.
  相似文献   

13.
Summary Two packing materials, C18 and PLRP-S, are studied for on-line trace enrichment of phenolic compounds in water. Various precolumns of different internal diameter are also tested and the addition of an ion-pair reagent to increase retention and thus, breakthrough volumes of phenolic compounds, is studied. Best results are obtained when a PLRP-S precolumn is coupled on-line with a C18 analytical column and DAD detector. Addition of TBA considerably increases breakthrough volumes. In contrast, when a C18 precolumn is used, breakthrough volumes are lower and it is impossible to determine TCP and PCP, under the experimental conditions used, because of interference of other nonpolar compounds in the samples. The performance of the system is evaluated with river and tap water and the preconcentration of 10 ml of sample in a PLRP-S precolumn involves a linear range between 1 g 1–1 and 20 l–1 and limits of determination between 0.5 g l–1 and 1 g l–1 are obtained.  相似文献   

14.
The absorption spectra of 4f electron transitions of the complexes of neodymium and erbium with 5,7-dibromo-8-hydroxyquinoline in the presence of octylphenol poly(ethyleneglycol)ether have been studied by normal and third-derivative spectrophotometry. The proposed method is free of interference of other rare earths. The calibration graphs were linear up to 18 g/ml of neodymium and 21 g/ml of erbium (in the final solution). The derivative molar absorptivities are 395 l.mol–1.cm–1 for neodymium and 3421.mol–1.cm–1 for erbium. The corresponding values of Sandell's sensitivity were 0.36 and 0.49 g.cm–1, respectively. The relative standard deviations evaluated from ten independent determinations of 2.5 g/ml of neodymium and erbium are 1.5 and 3.8% for neodymium and 1.8 and 4.1% for erbium in absence and presence of 70 g of lanthanum, respectively. The detection limits (signal to noise ratio=2) are 0.23 g/ml for neodymium and 0.30 g/ml for erbium. The method has been used for the determination of neodymium and erbium in mixed rare earths with satisfactory results.  相似文献   

15.
Summary A simple multi-residue procedure has been developed and applied to the analysis of pesticides in groundwater samples from the Comunidad Valenciana, a predominantly agricultural area on the Mediterranean coast of Spain. The procedure includes a liquid-liquid extraction, after addition of NaCl on the samples, and a subsequent analysis by capillary gas chromatography using a dual detection system with electron capture and nitrogen-phosphorous detectors. This allows the determination of more than 30 compounds (organophosphorous, organochlorine and pyrethroid pesticides) at the low ppb (g l–1) levels. Detection limits obtained varied between 0.01 g l–1 (lindane, fonofos) and 0.5 g l–1 (cypermethrin). An additional injection of the sample extracts into a gas chromatograph equipped with a column of different polarity and electron capture detector is used for the confirmation of chromatographic peaks. The recommended procedure has been applied to 66 ground water samples. Pesticides, including organophosphorus and organochlorine compounds were detected in 31 of them, in levels ranging from 0.02 to 0.7 g l–1.  相似文献   

16.
Summary A simultaneous capillary Gas Chromatographic-Mass Spectrometric (GC-MS) method is described for the determination of thirteen pesticides belonging to the triazine and amide families in water. The sample is extracted in liquid-liquid mode (dichloromethane) and then the determination of the residues is carried out by capillary gas chromatography with mass spectrometric detection in the Selected-Ion Monitoring mode (SIM). The average recoveries of spiked compounds are in the 78.4–135.4% range between the relative low level (0.100 g L–1) and the relative high level (10.0 g L–1). The limits of detection (LOD) are in the 0.009–0.128 g L–1 range.  相似文献   

17.
A method for simultaneous determination of traces of zinc, iron, and chloride ions by fast scan or ordinary differential pulse polarography has been proposed. The method is especially suited to check the purity of radiopharmaceutical gallium /67Ga/ citrate injections. The interference of citrate ions was eliminated by using a complex-forming base electrolyte containing triethanolamine and ammonia. The relative standard deviation of the determination of iron, zinc, and Cl ions in the range of 0.05–1.00 g of Fe or Zn and 3–25 g of Cl per ml solution was found to be 5–10%.  相似文献   

18.
Column preconcentration methods have been established for the spectrophotometric determination of trace nitrite with sulfanilic acid (SA) orp-aminoacetophenone (AAP) as the diazotizable aromatic amine andN, N-dimethylaniline (DMA) or 1-aminonaphthalene (AN) as the coupling agent, using differention-pairs co-precipitated with biphenyl. Nitrite ion reacts with SA in the pH range 2.0–3.0 and AAP in the pH range 1.7–3.0 in HCl medium to form water-soluble colourless diazonium cations. These cations are subsequently coupled with DMA in the pH range 3.7–6.1 for the SA-DMA system and AN in the pH range 1.7–2.3 for the AAP-AN system to be retained on microcrystalline biphenyl packed in a column. The solid mass is dissolved out from the column with 5 ml of DMF and the absorbance is measured by a spectrophotometer at 420 nm for the SA-DMA system and at 517 nm for the AAP-AN system. The calibration was linear over the concentration ranges 0.3–6.0 g of nitrite in 5 ml of DMF solution (i.e., 0.02–0.40 g/ml in the sample solution) for the SA-DMA system and 0.5–7.0 g of nitrite in 5 ml of DMF solution (i.e., 0.03–0.47 g/ml in the sample solution) for the AAP-AN system. The molar absorptivity and Sandell's sensitivity were respectively 2.63 × 104lmol–1cm–1 and 1.75 × 10–3 g cm–2 for SA-DMA and 3.28 × 104lmol–1 cm–1 and 1.40 × 10–3 g cm–2 for AAP-AN. The concentration factors were 4 and 16 for SA-DMA and AAP-AN, respectively. The detection limits were 0.0138 and 0.0175 g/ml NO2 for SA-DMA and AAP-AN, respectively. Seven replicate determinations of a solution containing 3.5 g of nitrite gave mean absorbances of 0.410 and 0.500 with relative standard deviations of 0.51 and 0.55% for SA-DMA and AAP-AN, respectively. Interference from various foreign ions has been studied and the methods have been applied to the determination of nitrite in environmental samples.  相似文献   

19.
Summary A method has been proposed for the determination of small quantities of Cl, SCN and I in mixtures. The method is based on the use of filter paper evenly impregnated with Ag2CrO4. The method permits the determination of 5 to 50g of Cl; 15 to 100g of I and 10 to 150g of SCN with an accuracy of 1.5%.The method may also be used for determination of SCN alone.
Zusammenfassung Ein Verfahren für die Bestimmung kleiner Mengen Chlorid, Rhodanid und Jodid in deren Gemischen wird vorgeschlagen. Es beruht auf der Verwendung eines mit Silberchromat gleichmäßig imprägnierten Filtrierpapierstreifens und ermöglicht die Bestimmung von 5 bis 50g Chlorid,15 bis 100g Jodid und 10 bis 150g Rhodanid mit einer Genauigkeit von 1,5%. Das Verfahren kann auch für die Bestimmung von Rhodanid allein verwendet werden.

Résumé On a proposé une méthode pour le dosage de petites quantités de Cl, SCN, et I en mélanges. La méthode est fondée sur l'emploi d'un papierfiltre uniformément imprégné d'Ag2CrO4. Elle permet le dosage de 5 à 50g de Cl, 15 à 100g d'I et de 10 à 150g de SON, à la précision de 1,5%. On peut aussi utiliser la méthode pour le dosage de SCN seul.
  相似文献   

20.
A sensitive and selective method is described for the determination of neodymium in mixed rare earths using fourth-derivative spectrophotometry. The method is based on the absorption spectra of 4f electron transitions of the complex of neodymium with methyl thymol blue and cetylpyridinium chloride. The influence of various instrumental parameters and reaction conditions for maximum colour development are investigated. The calibration curve is linear over the range 0–3.5 g ml–1 neodymium. The relative standard deviation for determination of 1.4 g ml–1 neodymium (n = 7) is 1.6%. The detection limit (signal-to-noise ratio = 3) is 0.2 g ml–1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号