首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 842 毫秒
1.
Y. Zhao 《Chromatographia》2000,51(3-4):231-234
Summary A new chelating reagent 2-thiophenaldehyde-4-phenyl-3-thiosemicarbazone (TAPT) has been examined for high performance liquid chromatographic (HPLC) separations of cobalt (II), copper(II) and iron (II) or cobalt (II), nickel (II), iron (II), copper (II) and mercury (II) as metal chelates on a C18, 5μm column (250×4 mm i.d.) The chelates were eluted isocratically with methanol: acetonitrile: water containing sodium acetate and tetrabutylammonium bromide (TBA), and detected at 254 nm. A solvent extraction procedure was developed for simultaneous determination of the metals with detection limits within 0.02–2.5 μ g.mL−1. The method was applied to the determination of copper, cobalt and iron in natural waters.  相似文献   

2.
Homogeneous liquid-liquid extraction method was studied based on a phase separation phenomenon in a ternary solvent system. According to this procedure, mononitrotoloenes were extracted by single-phase extraction in a water/methanol/chloroform, homogeneous ternary solvent system. Methanol and chloroform were used as consolute and extraction solvents, respectively. The homogeneous solution was broken by the addition of salt and a cloudy solution was formed. After centrifugation, the fine droplets of the extraction solvent were sedimented in the bottom of the conical test tube. Analysis of the extracts was carried out by gas chromatography. The optimization procedure was performed using Box-Behnken design. The variables involved were: sample and extraction solvent volumes, consolute solvent volume and phase separator reagent concentration. Optimum results were obtained under the following conditions: sample volume of 5 mL, extraction solvent volume of 55 μL, consolute solvent volume of 1 mL and phase separator reagent concentration; 5% (w/v). Under these conditions, the enrichment factors of 354, 311 and 300, dynamic linear ranges of 0.5-500, 1-500 and 1-500 μg L−1, and limit of detections (LODs) of 0.09, 0.09 and 0.1 μg L−1 were obtained for o-nitrotoluene, m-nitrotoluene and p-nitrotoluene, respectively. Finally, the method was successfully applied to the extraction and determination of MNTs in the waste water samples in the range of micrograms per liter with R.S.Ds. < 13.2%.  相似文献   

3.
A simple and rapid dispersive liquid-liquid microextraction procedure based on an ionic liquid (IL-DLLME) was developed for selective determination of cobalt (Co) with electrothermal atomic absorption spectrometry (ETAAS) detection. Cobalt was initially complexed with 1-nitroso-2-naphtol (1N2N) reagent at pH 4.0. The IL-DLLME procedure was then performed by using a few microliters of the room temperature ionic liquid (RTIL) 1-hexyl-3-methylimidazolium hexafluorophosphate [C6mim][PF6] as extractant while methanol was the dispersant solvent. After microextraction procedure, the Co-enriched RTIL phase was solubilized in methanol and directly injected into the graphite furnace. The effect of several variables on Co-1N2N complex formation, extraction with the dispersed RTIL phase, and analyte detection with ETAAS, was carefully studied in this work. An enrichment factor of 120 was obtained with only 6 mL of sample solution and under optimal experimental conditions. The resultant limit of detection (LOD) was 3.8 ng L−1, while the relative standard deviation (RSD) was 3.4% (at 1 μg L−1 Co level and n = 10), calculated from the peak height of absorbance signals. The accuracy of the proposed methodology was tested by analysis of a certified reference material. The method was successfully applied for the determination of Co in environmental and biological samples.  相似文献   

4.
The removal of excess reagent extracted into an organic phase in the solvent extraction of a metal complex anion with a quaternary ammonium ion is discussed. With a given chelating ligand (HO—R—SO3H), the order of extractability is HO—R—SO3- > M(OR—SO3)n- > X- > -O—R—SO3- when an anion such as nitrate or halide is added. If suitable amounts of the anion are added, only the excess of reagent can be removed. The principle is applied to the extraction with zephiramine of the cobalt complex anion formed with 2-nitroso-1-naphthol-4-sulfonic acid. Micro amounts of cobalt in pure nickel salts were determined spectrophotometrically.  相似文献   

5.
A preconcentration method for manganese determination by sequential injection cloud point extraction with subsequent detection by flame atomic absorption spectrometry (FAAS) has been developed. The enrichment of Mn was performed after a preliminary on-line cloud point extraction and entrapment of manganese-containing surfactant aggregated within a minicolumn packed with cotton. The laboratory-made reagent 4-(5′-bromo-2′-thiazolylazo)orcinol (Br-TAO) and the surfactant Triton X-114 were used for cloud point extraction. The manganese ions were eluted with sulphuric acid solution and directly introduced into the FAAS. Chemical and flow variables affecting the preconcentration were studied. Using a sample volume of 2.80 mL the limit of detection and enrichment factor were calculated to be 0.5 μg L−1 and 14, respectively. The sample frequency is 48 h−1, considering a total run cycle of 75 s. The accuracy of the proposed method has been demonstrated by the analysis of the certified reference biological materials rice flour and tomato leaves. The method has been applied to determination of manganese in food samples.  相似文献   

6.
The supramolecular solvent system consists of tetrahydrofuran (THF) and 1-decanol, that was used as an extraction solvent for a microextraction procedure for the preconcentration and separation of Co(II). The proposed supramolecular-based procedure was combined with microsampling flame atomic absorption spectrometry for the determination of cobalt at trace levels in water samples. N-Benzoyl-N,N-diisobutylthiourea was used to chelate Co(II) in an aqueous solution. Quantitative extraction efficiency was obtained at pH 6.5. The effects of analytical parameters including pH, amount of ligand, type, ratio and volume of supramolecular solvent, sample volume and interfering ions were investigated for optimisation of the procedure. The proposed supramolecular solvent-based microextraction procedure (Ss-ME) exhibits a limit of detection (LOD) of 1.29 µg L?1 and a limit of quantification (LOQ) of 3.88 µg L?1. The procedure was validated by addition/recovery tests and by applying TMDA 64.2 and TMDA 53.3 water certified reference materials. The microextraction method was successfully applied for the preconcentration and determination of cobalt in water samples.  相似文献   

7.
This paper presents a novel approach to dispersive liquid-liquid microextraction (DLLME), based on the use of an auxiliary solvent for the adjustment of density. The procedure utilises a solvent system consisting of a dispersive solvent, an extraction solvent and an auxiliary solvent, which allows for the use of solvents having a density lower than that of water as an extraction solvent while preserving simple phase separation by centrifugation. The suggested approach could be an alternative to procedures described in the literature in recent months and which have been devoted to solving the same problem. The efficiency of the suggested approach is demonstrated through the determination of gold based on the formation of the ion pair [Au(CN)2] anion with Astra Phloxine (R) reagent and its extraction using the DLLME procedure with subsequent UV-VIS spectrophotometric and graphite furnace atomic absorption spectrometric detection. The optimum conditions were found to be: pH 3; 0.8 mmol L−1 K4[Fe(CN)6]; 0.12 mmol L−1 R; dispersive solvent, methanol; extraction solvent, toluene; auxiliary solvent, tetrachloromethane. The calibration plots were linear in the ranges 0.39-4.7 mg L−1 and 0.5-39.4 μg L−1 for UV-VIS and GFAAS detection, respectively; thus enables the application of the developed method in two ranges differing from one from another by three orders of magnitude. The presented approach can be applied to the development of DLLME procedures for the determination of other compounds extractable by organic solvents with a density lower than that of water.  相似文献   

8.
Chen L  Ding L  Yu A  Yang R  Wang X  Li J  Jin H  Zhang H 《Analytica chimica acta》2007,596(1):164-170
This paper describes a new method for the determination of total flavonoids in Platycladus orientalis (L.) Franco. The method was based on dynamic microwave-assisted extraction (DMAE) coupled with on-line derivatization and ultraviolet-visible (UV-vis) detection. The influence of the experimental conditions was tested. Maximum extraction yield was achieved using 80% aqueous methanol of extraction solvent; 80 W of microwave output power; 5 min of extraction time; 1.0 mL min−1 of extraction solvent flow rate. The derivatization reaction between aluminium chloride and flavonoid is one of the most sensitive and selective reactions for total flavonoids determination. The optimized derivatization conditions are as follows: derivatization reagent 1.5% aluminium chloride methanol solution; reaction coil length 100 cm; derivatization reagent flow rate 1.5 mL min−1. The detection and quantification limits obtained are 0.28 and 0.92 mg g−1, respectively. The intra-day and inter-day precisions (R.S.D.) obtained are 1.5% and 4.6%, respectively. Mean recovery is 98.5%. This method was successfully applied to the determination of total flavonoids in P. orientalis (L.) Franco and compared with heat reflux extraction. The results showed that the higher extraction yield of total flavonoids was obtained by DMAE with shorter extraction time (5 min) and small quantity of extraction solvent (5 mL).  相似文献   

9.
A novel, simple and environmentally friendly procedure for silver determination has been developed. The method is based on ion associate formation of AgI2 and bisindocarbocyanine chloride (BDIC) reagent, followed by dispersive liquid–liquid microextraction (DLLME) of the ion associate formed and subsequent UV–Vis spectrophotometric detection. The structure of BDIC and the reaction mechanism were investigated by MS and NMR measurements and quantum chemical calculations.The optimum experimental conditions were found to be: pH 6; 0.1 mol L− 1 KI; 5 × 10− 5 mol L− 1 BDIC. The DLLME procedure was carried out using an auxiliary solvent for adjustment of solvent density. A 0.5 mL mixture of toluene as extraction solvent, carbon tetrachloride as auxiliary solvent and ethanol as disperser solvent was used. Ultrasonication of the organic phase was applied to decrease the value of the blank test. The absorbance of the coloured extracts obeys Beer's law in the range 0.07–2.1 mg L− 1 of Ag at 566 nm wavelength. The limit of detection, calculated from a blank test (n = 10) based on 3 s, is 0.03 mg L− 1 of Ag. The developed procedure was applied to the determination of silver in real samples such as Nano Silver and semi-conductor thin films.  相似文献   

10.
We report on a new method for the dispersive liquid-liquid microextraction of Cd(II), Co(II), Pb(II) and Ni (II) from water samples prior to their simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The procedure is based on the injection of a ternary solvent system composed of appropriate quantities of extraction solvent (trichloroethylene), dispersive solvent (ethanol), and the chelating reagent 2-(2′-benzothiazolylazo)-p-cresol into the sample solution. The solution turns turbid immediately after injection, and the analytes are extracted into the droplets of the organic phase which was dried and dissolved in a mixture of Triton X-114, nitric acid, and ethanol. The metal ions in this mixture were quantified by ICP-OES. The detection limits under optimized conditions are 0.2, 0.3, 0.2 and 0.7?μg?L?1 for Cd(II), Co(II), Pb(II) and Ni(II), respectively. The enrichment factors were also calculated for Cd (13), Co (11), Pb (11) and Ni (8). The procedure was applied to the determination of cadmium, cobalt, lead and nickel in certified reference material (waterway sediment) and water samples.
Figure
A new method for the dispersive liquid-liquid microextraction of Cd(II), Co(II), Pb(II) and Ni(II) from water samples prior to their simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP OES) is presented. The procedure was applied to the determination of elements in samples of river and lake water.  相似文献   

11.
An extraction procedure with iso-amylalcohol for the determination of traces of cobalt was developed using isonitrosodimedon. At 374mμ, the wavelength of maximal absorption, the molar extinction coefficient is as high as 19.680, allowing cobalt determination as low as 0.5μg/ml in the organic phase. The extraction is quantitative between pH 4 and 7. The most common ions in a 100-fold excess do not disturb the determination, though Fe+3, Cu+2, Cr+3 and Ni+2 should be absent.  相似文献   

12.
A new simple and rapid dispersive liquid–liquid microextraction has been applied to preconcentrate trace levels of cobalt as a prior step to its determination by spectrophotometric detection. In this method a small amount of chloroform as the extraction solvent was dissolved in pure ethanol as the disperser solvent, then the binary solution was rapidly injected by a syringe into the water sample containing cobalt ions complexed by 1-(2-pyridylazo)-2-naphthol (PAN). This forms a cloudy solution. The cloudy state was the result of chloroform fine droplets formation, which has been dispersed in bulk aqueous sample. Therefore, Co-PAN complex was extracted into the fine chloroform droplets. After centrifugation (2 min at 5000 rpm) these droplets were sedimented at the bottom of conical test tube (about 100 µL) and then the whole of complex enriched extracted phase was determined by a spectrophotometer at 577 nm. Complex formation and extraction are usually affected by some parameters, such as the types and volumes of extraction solvent and disperser solvent, salt effect, pH and the concentration of chelating agent, which have been optimised for the presented method. Under optimum conditions, the enhancement factor (as the ratio of slope of preconcentrated sample to that obtained without preconcentration) of 125 was obtained from 50 mL of water sample, and the limit of detection (LOD) of the method was 0.5 µg L?1and the relative standard deviation (RSD, n = 5) for 50 µg L?1 of cobalt was 2.5%. The method was applied to the determination of cobalt in tap and river water samples.  相似文献   

13.
The development of a spectrophotometric method for the determination of hydrogen peroxide in uranyl nitrate solutions is reported. The method involves the measurement of the absorbance at 520 nm of a vanadyl peroxide species. This species was formed by the addition of a reagent consisting of vanadium (V) (50 mmol·dm−3) in dilute sulphuric acid (2 mol·dm−3 H2SO4). This reagent, after dilution, was also used as an extractant for organic phase samples. The method is simple and robust and tolerant of nitric acid and U(VI). Specificity and accuracy were improved by the application of solid phase extraction techniques to remove entrained organic solvents and Pu(IV). Reverse phase solid phase extraction was used to clean-up aqueous samples or extracts which were contaminated with entrained solvent. A solid phase extraction system based upon an extraction chromatography system was used to remove Pu(IV). Detection limits of 26 μmol·dm−3 (0.88 μg·cm−3) or 7 μmol·dm−3 (0.24 μg·cm−3) for, respectively, a 1 and 4 cm path length cell were obtained. Precisions of RSD=1.4% and 19.5% were obtained at the extremes of the calibration curve (5 mmol·dm−3 and 50 μmol·dm−3 H2O2, 1 cm cell). The introduction of the extraction and clean-up stages had a negligible effect upon the precision of the determination. The stability of an organic phase sample was tested and no loss of analyte could be discerned over a period of at least 5 days. The presence of trace levels of reductants interfered with the determination, e.g., hydrazine (<2 mmol·dm−3), but this effect was ameliorated by increasing the concentration of the colormetric reagent.  相似文献   

14.
Nascentes CC  Arruda MA 《Talanta》2003,61(6):759-768
A new micelle-mediated phase separation of metal ions, applied for preconcentrating trace levels of cobalt as a prior step to its determination by flame atomic spectroscopy, has been developed. Two methods were proposed employing both Triton X-100 and sodium dodecyl sulfate (SDS) as a mixed micellar system while the phase separation was induced by HCl or NaCl addition. Cobalt was complexed with pyridylazo compounds (PAN, PAR, 5-Br-PADAP) in an aqueous surfactant medium and it was concentrated in the surfactant rich phase after phase separation. The chemical variables affecting the cloud point extraction were evaluated, optimized and successfully applied to cobalt determination in pharmaceutical samples. Under the optimized conditions, the preconcentration system permitted limits of detection as 1.1 and 1.6 μg l−1 cobalt, respectively, when HCl and NaCl were used. Both proposed methods showed linear calibration within a 25-200 μg l−1 cobalt range. The extraction efficiency was investigated at different cobalt concentrations (40-185 μg l−1) and good recoveries (98-102%) were obtained by using NaCl as electrolyte. The results obtained were compared with those observed with ET AAS.  相似文献   

15.
A new dispersive liquid–liquid microextraction based on solidification of floating organic droplet method (DLLME-SFO) was developed for the determination of volatile aldehyde biomarkers (hexanal and heptanal) in human blood samples. In the derivatization and extraction procedure, 2,4-dinitrophenylhydrazine (DNPH) as derivatization reagent and formic acid as catalyzer were injected into the sample solution for derivatization with aldehydes, then the formed hydrazones was rapidly extracted by dispersive liquid–liquid microextraction with 1-dodecanol as extraction solvent. After centrifugation, the floated droplet was solidified in an ice bath and was easily removed for analysis. The effects of various experimental parameters on derivatization and extraction conditions were studied, such as the kind and volume of extraction solvent and dispersive solvent, the amount of derivatization reagent, derivatization temperature and time, extraction time and salt effect. The limit of detections (LODs) for hexanal and heptanal were 7.90 and 2.34 nmol L−1, respectively. Good reproducibility and recovery of the method were also obtained. The proposed method is an alternative approach to the quantification of volatile aldehyde biomarkers in complex biological samples, being more rapid and simpler and providing higher sensitivity compared with the traditional dispersive liquid–liquid microextraction (DLLME) methods.  相似文献   

16.
Comitre AL  Reis BF 《Talanta》2005,65(4):846-852
A not expensive automatic flow system based on multicommutation and exploiting the liquid-liquid extraction methodology for the determination of lead in plant material is described. The spectrophotometric procedure for lead determination was based on the reaction with dithizone followed by extraction using an organic solvent. The facilities afforded by the multicommutation approach allowed the use of an air stream as carrier, thus contributing to reduce the overall waste generation. The results obtained analysing plant materials compare very well with those obtained employing inductive coupled plasma optical emission spectrometry (ICP OES) at 90% confidence level. Others profitable features such as a linear response range between 50 and 200 μg l−1 Pb (r = 0.999); a sampling rate of 15 determination per hour; a relative standard deviation of 1.8% (n = 12) for a typical sample containing 163 μg l−1 Pb; a detection limit of 12 μg l−1; a reagent consumption of 4.5 mg dithizone; and a waste generation of 225 μl organic solvent per determination were also achieved.  相似文献   

17.
The synthesis and characterization of the reagent 2-(5-bromothiazolylazo)-4-chlorophenol and its application in the development of a preconcentration procedure for cobalt determination using flame atomic absorption spectrometry after cloud point extraction is presented. This procedure is based on cobalt complexing and entrapment of the metal chelates into micelles of a surfactant-rich phase of Triton X-114. The preconcentration procedure was optimized by using a response surface methodology through the application of the Box-Behnken matrix. Under optimum conditions, the procedure determined the presence of cobalt with an LOD of 2.8 microg/L and LOQ of 9.3 microg/L. The enrichment factor obtained was 25. The precision was evaluated as the RSD, which was 5.5% for 10 microg/L cobalt and 6.9% for 30 microg/L. The accuracy of the procedure was assessed by comparing the results with those found using inductively coupled plasma-optical emission spectrometry. After validation, the procedure was applied to the determination of cobalt in pharmaceutical preparation samples containing cobalamin (vitamin B12).  相似文献   

18.
Ultrasound-assisted emulsification-microextraction (USAEME) procedure was developed for the determination of selected polychlorinated biphenyls (PCBs) in 10 mL of water samples by gas chromatography-mass-selective detection. After determination of the most suitable solvent and extraction time, several other parameters including solvent volume, centrifugation time and ionic strength of the sample were optimized using a 23 factorial experimental design. The optimized USAEME procedure used 200 μL of chloroform as extraction solvent, 10 min of extraction with no ionic strength adjustment at 25 °C and 5 min of centrifugation at 4000 rpm. The limits of detection ranged from 14 ng L−1 (for PCB153) to 30 ng L−1 (for PCB101). Recoveries of PCBs from fortified distilled water are over 80% for three different fortification levels between 0.1 and 5 μg L−1 and relative standard deviations of the recoveries are below 10%. The performance of the proposed method was compared with those involving traditional liquid-liquid extraction (LLE) and solid phase extraction (SPE) on the real water samples (i.e., tap and well water as well as domestic and industrial wastewaters, etc.) and comparable efficiencies were obtained. The proposed USAEME procedure has been demonstrated to be viable, simple, rapid and easy to use for residue analysis of PCBs in water samples.  相似文献   

19.
A substoichiometric radiochemical solventextraction method is described for the determination of cobalt, employing β-hydroxy-naphthaldoxime and chloroform as reagent and extractant, respectively. The extraction behaviour of the complex of cobalt with the reagent in the pH-range 8–9.5 and the effects of various metal ions on the extraction are critically studied. The method is used to determine the cobalt content in some pharmaceutical drugs. Received: 10 January 1997 / Revised: 11 March 1997 / Accepted: 25 March 1997  相似文献   

20.
Khuhawar MY  Lanjwani SN 《Talanta》1998,46(4):485-490
The complexing reagent 2-thiophenaldehyde-4-phenyl-3-thiosemicarbazone (TAPT) was examined for high performance liquid chromatographic (HPLC) separations of cobalt(II), copper(II) and iron(II) or cobalt(II), nickel(II), iron(II), copper(II) and mercury(II) as metal chelates on a Microsorb C-18, 5-mum column (150x4.6 mm i.d.) (Rainin Instruments Woburn, MA, USA). The complexes were eluted isocratically with methanol:acetonitrile:water containing sodium acetate and tetrabutyl ammonium bromide (TBA). UV detection was at 254 nm. The solvent extraction procedure was developed for simultaneous determination of the metals, with detection limits within 0.5-2.5 mug ml(-1) in the final solution. The method was applied for the determination of copper, cobalt and iron in pharmaceutical preparation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号