共查询到20条相似文献,搜索用时 0 毫秒
1.
Sarrión MN Santos FJ Moyano E Galceran MT 《Rapid communications in mass spectrometry : RCM》2003,17(1):39-48
Liquid chromatography with atmospheric pressure chemical ionisation mass spectrometry (LC/APCI-MS), using negative ion detection in a triple quadrupole instrument, was used for the determination of chlorophenols (CPs) in environmental samples. In-source collision-induced dissociation (CID) was compared with MS/MS fragmentation. In general, less fragmentation was observed in MS/MS as compared with in-source CID, with the latter providing more intense fragment ions due to chemical ionisation. Under MS/MS conditions [M - H - HCl](-) was the main fragment ion observed for all compounds except for pentachlorophenol, which showed no fragmentation. For multiple reaction monitoring (MRM) acquisition mode, the transition from [M - H](-) to [M - H - HCl](-) was selected, leading to detection limits down to 0.3 ng injected. Direct and headspace-solid-phase microextraction (HS-SPME) were used as preconcentration procedures for the analysis of CPs in wood and in industrially contaminated soils. CPs were quantified by standard addition, which led to good reproducibility (RSD between 4 and 11%) in both SIM and MRM modes, and detection limits down to ng/g. The combination of MS/MS and in-source CID allowed confirmation of the presence of CPs in environmental samples. 相似文献
2.
The feasibility of direct-immersion (DI) solid-phase microextraction (SPME) and headspace (HS) SPME for the determination of high-ring polycyclic aromatic hydrocarbons (PAHs) (4- to 6-ring PAHs) in water and soil samples is studied. Three SPME fibers--100- and 30-microm polydimethylsiloxane (PDMS) and 85-microm polyacrylate (PA) fibers-are compared for the effective extraction of PAHs. Parameters affecting the sorption of PAHs into the fiber such as sampling time, sampling volume, and temperature are also evaluated. The extracted amounts of high-ring PAHs decrease with the decreasing of film thickness, and the 100-microm PDMS has the highest extraction efficiency than 85-microm PA and 30-microm PDMS fibers. Also, the extraction efficiency decreases with the increasing molecular weights of PAHs. Of the 10 high-ring PAHs, only fluoranthene and pyrene can reach equilibrium within 120 min at 25 degrees C for DI-SPME in a water sample. Increasing the temperature to 60 degrees C can increase the sensitivity of PAHs and shorten the equilibrium time. A 0.7- to 25-fold increase in peak area is obtained for DI-SPME when the working temperature is increased to 60 degrees C. For HS-SPME, the extraction efficiency of PAHs decrease when the headspace volume of the sampling system increases. All high-ring PAHs can be detected in a water sample by increasing the temperature to 80 degrees C. However, only 4- and 5-ring PAHs can be quantitated in a CRM soil sample when HS-SPME is used. The addition of a surfactant with high hydrophilic property can effectively enhance the sensitivity of high-ring PAHs. HS-SPME as well as DI-SPME with 100-microm PDMS or 85-microm PA fibers are shown to be suitable methods for analyzing high-ring PAHs in a water sample; however, this technique can only apply in a soil sample for PAHs having up to 5 rings. 相似文献
3.
Solid-phase microextraction coupled with high-performance liquid chromatography was successfully applied to the analysis of nine phenylurea herbicides (metoxuron, monuron, chlorotoluron, isoproturon, monolinuron, metobromuron, buturon, linuron, and chlorbromuron). Polydimethylsiloxane-divinylbenzene (PDMS-DVB, 60 microm) and Carbowax-templated resin (CW-TPR, 50 microm) fibers were selected from four commercial fibers for further study because of their better extraction efficiencies. The parameters of the desorption procedure were studied and optimized. The effects of the properties of analytes and fiber coatings, carryover, duration and temperature of absorption, pH, organic solvent and ionic strength of samples were also investigated. External calibration with an aqueous standard can be used for the analysis of environmental samples (lake water) using either PDMS-DVB or CW-TPR fibers. Good precisions (1.0-5.9%) are achieved for this method, and the detection limits are at the level of 0.5-5.1 ng/ml. 相似文献
4.
Solid-phase microextraction versus single-drop microextraction for the analysis of nitroaromatic explosives in water samples. 总被引:1,自引:0,他引:1
This paper compares solid-phase microextraction (SPME) with a recently developed extraction method called single-drop microextraction (SDME) for the analysis of nitroaromatic explosives in water samples. The two techniques are examined in terms of procedure, chromatographic analysis and method performance. All practical considerations for both techniques are also reviewed. SPME requires dedicated apparatus and is relatively expensive, as the fiber's lifetime is limited. However, it has the advantages over SDME that it can be easily used for headspace analysis and has lower detection limits for all the target analytes. SDME requires more elaborate manual operations, thus affecting linearity and precision. 相似文献
5.
A solid-phase microextraction (SPME) and gas chromatography-mass spectrometry method for determining polycyclic aromatic hydrocarbons (PAHs) in environmental solid matrices is developed. Investigated matrices include seaweed (Undaria pinnatifida and Himanthalia elongata), humic substances (isolated from a wetland out-flow and purchased from Aldrich), and soil. Optimal conditions for a good SPME efficiency of 16 hydrocarbon compounds are obtained using a 100- micro m polydimethylsiloxane fiber directly immersed in aqueous carrier medium. The method is remarkable for presenting short extraction times and considerably high sensitivities. The SPME results obtained by using internal calibration give the total analyte concentration based on the identical partitioning behavior of native and spiked pollutants. The detection limits range from 0.001 to 0.1 mg of PAH per kilogram of dry matrix. SPME external calibration provides information regarding freely dissolved analytes. The detection limits range from 0.001 to 0.05 micro g of PAH per liter of carrier medium. The SPME with external calibration procedure can be applied to measure free concentrations of a target compound spiked into a carrier medium and onto a matrix. Based on a comparison of results obtained for the two samples, the partitioning of the target analyte between the matrix and the carrier medium is calculated. 相似文献
6.
Solid-phase microextraction for the analysis of short-chain chlorinated paraffins in water samples 总被引:2,自引:0,他引:2
A novel solid-phase microextraction (SPME) method coupled to gas chromatography with electron capture detection (GC-ECD) was developed as an alternative to liquid-liquid and solid-phase extraction for the analysis of short-chain chlorinated paraffins (SCCPs) in water samples. The extraction efficiency of five different commercially available fibres was evaluated and the 100-microm polydimethylsiloxane coating was the most suitable for the absorption of the SCCPs. Optimisation of several SPME parameters, such as extraction time and temperature, ionic strength and desorption time, was performed. Quality parameters were established using Milli-Q, tap water and river water. Linearity ranged between 0.06 and 6 microg l(-1) for spiked Milli-Q water and between 0.6 and 6 microg l(-1) for natural waters. The precision of the SPME-GC-ECD method for the three aqueous matrices was similar and gave relative standard deviations (RSD) between 12 and 14%. The limit of detection (LOD) was 0.02 microg l(-1) for Milli-Q water and 0.3 microg l(-1) for both tap water and river water. The optimised SPME-GC-ECD method was successfully applied to the determination of SCCPs in river water samples. 相似文献
7.
A highly selective, sensitive and rapid method for the determination of trace amounts of inorganic mercury based on the reaction of Hg (II) with 6-mercaptopurine and the solid phase extraction of the complex on C18 membrane disks was developed. The 6-mercaptopurine selectively reacts with Hg (II) to form a complex in the pH range of 5-8. This complex was preconcentrated by solid phase extraction with C18 disks. An enrichment factor of 100 was achieved. The molar absorptivity of the complex is 0.26 x 10(-6) L. mol(-1) cm(-1) measured at 315 nm. The Beer's law is obeyed in the concentration range of 0.002-0.048 microg mL(-1). The relative standard deviation for eleven-replicated measurement of 0.04 microg mL(-1) is 1.5 %. The detection limit is 0.001 microg mL(-1) in the water samples. The advantage of the method is that the determination of Hg (II) is free from interference of almost all the cations and anions found in environment and wastewater samples. The determination of Hg (II) in water samples of different origins and marine sediment were carried out by the present method and cold vapor atomic absorption spectrometry (CVAAS). Also the method's accuracy was investigated by using SRM 2709. The obtained results by the present procedure were in good agreement with those of the CVAAS and certified value, so that the applicability of the proposed method was confirmed for the real samples. 相似文献
8.
Solid-phase microextraction: a promising technique for sample preparation in environmental analysis 总被引:16,自引:0,他引:16
Alpendurada MF 《Journal of chromatography. A》2000,889(1-2):3-14
Solid-phase microextraction (SPME) is a simple and effective adsorption and desorption technique, which eliminates the need for solvents or complicated apparatus, for concentrating volatile or nonvolatile compounds in liquid samples or headspace. SPME is compatible with analyte separation and detection by gas chromatography and high-performance liquid chromatography, and provides linear results for wide concentrations of analytes. By controlling the polarity and thickness of the coating on the fibre, maintaining consistent sampling time, and adjusting other extraction parameters, an analyst can ensure highly consistent, quantifiable results for low concentration analytes. To date, about 400 articles on SPME have been published in different fields, including environment (water, soil, air), food, natural products, pharmaceuticals, biology, toxicology, forensics and theory. As the scope of SPME grew, new improvements were made with the appearance of new coatings that allowed an increase in the specificity of this extraction technique. The key part of the SPME fibre is of course the fibre coating. At the moment, 27 variations of fibre coating and size are available. Among the newest are a fibre assembly with a dual coating of divinylbenzene and Carboxen suspended in poly(dimethylsiloxane), and a series of 23 gauge fibres intended for specific septumless injection system. The growth of SPME is also reflected in the expanding number of the accessories that make the technology even easier to use Also available is a portable field sampler which is a self-contained unit that stores the SPME fibre after sampling and during the shipment to the laboratory. Several scientific publications show the results obtained in inter-laboratory validation studies in which SPME was applied to determine the presence of different organic compounds at ppt levels, which demonstrates the reliability of this extraction technique for quantitative analysis. 相似文献
9.
A headspace solid-phase microextraction (HS-SPME) method has been developed for the determination of iodinated trihalomethanes (ITHMs) in treated water samples. Mixed THMs (bromochloroido-, bromodiiodo-, chlorodiiodo-, dibromoiodo- and dichloroiodo-) were previously synthesized since commercial standards are not available. HS-SPME has shorter equilibration times than direct SPME, a cleaner background and a longer fiber life. Experimental parameters such as the selection of SPME coatings, sample volume, extraction time and addition of salts were studied. The Carbowax-divinylbenzene fiber appears to be the most suitable for the determination of ITHMs. Analytical parameters such as linearity, limit of detection and precision were also evaluated. HS-SPME was compared to liquid-liquid microextraction for the analyses of spiked treated water samples, obtaining a good agreement. It is concluded that HS-SPME has a great potential for drinking water analysis. 相似文献
10.
A. V. Chuikin S. V. Grigor’ev A. A. Velikov 《Russian Journal of Physical Chemistry A, Focus on Chemistry》2006,80(2):307-309
A concentrator was designed for solid-phase microextraction of aromatic compounds (benzene, toluene, ethylbenzene, o-xylene) from water samples. The concentrator was used as an attachment to a water vapor mobile phase chromatograph with a detection limit (compounds <1 μg/l). 相似文献
11.
Paula Berton 《Analytica chimica acta》2010,662(2):155-99
A simple and rapid dispersive liquid-liquid microextraction procedure based on an ionic liquid (IL-DLLME) was developed for selective determination of cobalt (Co) with electrothermal atomic absorption spectrometry (ETAAS) detection. Cobalt was initially complexed with 1-nitroso-2-naphtol (1N2N) reagent at pH 4.0. The IL-DLLME procedure was then performed by using a few microliters of the room temperature ionic liquid (RTIL) 1-hexyl-3-methylimidazolium hexafluorophosphate [C6mim][PF6] as extractant while methanol was the dispersant solvent. After microextraction procedure, the Co-enriched RTIL phase was solubilized in methanol and directly injected into the graphite furnace. The effect of several variables on Co-1N2N complex formation, extraction with the dispersed RTIL phase, and analyte detection with ETAAS, was carefully studied in this work. An enrichment factor of 120 was obtained with only 6 mL of sample solution and under optimal experimental conditions. The resultant limit of detection (LOD) was 3.8 ng L−1, while the relative standard deviation (RSD) was 3.4% (at 1 μg L−1 Co level and n = 10), calculated from the peak height of absorbance signals. The accuracy of the proposed methodology was tested by analysis of a certified reference material. The method was successfully applied for the determination of Co in environmental and biological samples. 相似文献
12.
Rapid determination of atrazine in environmental water samples by a novel liquid phase microextraction 总被引:2,自引:0,他引:2
Qing Xiang Zhou Guo Hong Xie Long Pang 《中国化学快报》2008,19(1):89-91
A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such as sample pH, extraction and disperser solvents, salting-out effect, and extraction time were investigated. The experimental results indicated that proposed method possessed an excellent analytical performance, The linear range, detection limit, and precision (R.S.D.) were 0.1- 50 ng mL- 1 (R2 = 0.9955), 0.601 ng mL- 1 and 6,4%, respectively. The proposed method was validated with the real water samples, and the spiked recoveries were in the range of 69.9-89.8%, respectively. These results indicated that the established method with high enrichment factor, short extraction time was an excellent alternative for the routine analysis of atrazine in environmental samples. 2007 Qing Xiang Zhou. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved. 相似文献
13.
Tsai HY Chang CM Shen JL Chen LJ Yang TF Bor Fuh C 《Journal of chromatographic science》2006,44(6):354-358
beta-Carotene in vegetables and nutritional products is analyzed using solid-phase microextraction (SPME) coupled with liquid chromatography (LC) to improve the speed of analysis and to reduce the consumption of organic solvents. The relative standard deviations (RSDs) of this analytical method for beta-carotene determinations in vegetables and nutritional products are approximately 10% and 5%, respectively. The amount of beta-carotene was found to vary from 0.35 +/- 0.05 ppm to 76.5 +/- 6.9 ppm for several vegetables in Taiwan. This method was linear over the range of 0.4-40 ppm with correlation coefficients higher than 0.997. The experimentally determined level of beta-carotene in nutritional products varied from 3.8 +/- 0.2 ppm to 24.6 +/- 1.1 ppm following SPME-LC. The recoveries of beta-carotene for these measurements following SPME were all higher than 97% +/- 2% (n = 3). The detection limits of beta-carotene for this method were from 0.027 to 0.054 ppm. Conventional solvent extractions take approximately 4-6 h for extraction and reconcentration but SPME takes approximately 1 h. From several tens to hundreds of milliliters, organic solvents can be saved using SPME. SPME provides better analyses on beta-carotene than conventional solvent extraction for nutritional products in terms of speed, precision, simplicity, and solvent consumption. 相似文献
14.
Peña RM Barciela J Herrero C García-Martín S 《Journal of separation science》2004,27(17-18):1540-1544
Solid-phase microextraction (SPME) using a 100 microm poly(dimethylsiloxane) (PDMS) fiber, followed by gas chromatography (GC-MS) determination, has been applied to the analysis of some monoterpenoids in honey. The extraction was performed by direct immersion of the fiber using a sampling period of 15 min with constant magnetic stirring (1100 rpm) and an extraction temperature of 20 degrees C. A 7 mL sample volume of an aqueous solution of honey with 25% of NaCl was placed in 15 mL glass vial fitted with screw cap and PTFE/silicone septum. Desorption was performed directly in the gas chromatograph injector port during 5 min at 250 degrees C using the splitless mode. The method is sensitive with detection limits between 11 and 25 microg L(-1), precise with coefficients of variation in the range 1.28 and 3.71%, and linear over more than one order of magnitude. The related conditions were used for honey sample analyses with recoveries between 71.8 and 90.9%. SPME remains an attractive alternative technique due to its rapidity and because it is a solvent free extraction method. 相似文献
15.
Sánchez-Ortega A Sampedro MC Unceta N Goicolea MA Barrio RJ 《Journal of chromatography. A》2005,1094(1-2):70-76
The aim of this study was to develop a methodology for the analysis of the insecticide fenitrothion and its two main environmental metabolites, fenitrooxon and 3-methyl-4-nitrophenol. For this purpose, a solid-phase microextraction (SPME) method coupled to high performance liquid chromatography (LC) was optimized. Two on-line detectors, diode array (DAD) and direct current amperometrical (DCAD) were used in order to determine sensitivity and selectivity. The effects of the extraction parameters, including exposure and desorption time, pH, temperature, salt concentration and desorption mode on the extraction efficiency were studied. A satisfactory reproducibility for extractions from samples at 20 ppb-level with RSD < 12.5% (n = 10) was obtained. The calibration graphs were linear in the range of 10-1000 microg l(-1) and detection limits for the target compounds were between 1.2 and 11.8 microg l(-1) depending on which detector was used. The method was applied for determining fenitrothion and both its metabolites in river waters which run through forest areas near to aerial application of the pesticide. 相似文献
16.
Solid-phase microextraction with on-fiber derivatization for the analysis of anti-inflammatory drugs in water samples 总被引:2,自引:0,他引:2
Rodríguez I Carpinteiro J Quintana JB Carro AM Lorenzo RA Cela R 《Journal of chromatography. A》2004,1024(1-2):1-8
A sensitive and solvent-free procedure for the determination of non-steroidal acidic anti-inflammatory drugs in water samples was optimized using solid-phase microextraction (SPME) followed by on-fiber silylation of the acidic compounds and gas chromatography-mass spectrometry (GC-MS) determination. Microextraction was carried out directly over the filtered water samples using a polyacrylate fiber. Derivatization was performed placing the SPME fiber, loaded with the extracted analytes, in the headspace of a vial containing 50 microl of N-methyl-N-(tert-butyldimethylsilyl)-trifluoroacetamide (MTBSTFA). Derivatives were desorbed for 3 min in the GC injector. Influence of several parameters in the efficiency of microextraction (volume of sample, time, pH, type of fiber coating, etc.) and derivatization steps (time, temperature and volume of MTBSTFA) was systematically investigated. In the optimal conditions an excellent linearity over three orders of magnitude and quantification limits at the ng/l level (from 12 to 40 ng/l) were achieved. The proposed method was applied to the determination of acidic compounds in sewage water and results compared to those obtained using solid-phase extraction (SPE) followed by the derivatization of the compounds in the organic extract of the solid-phase extraction cartridge. 相似文献
17.
A novel headspace solid-phase microextraction method for the exact determination of organochlorine pesticides in environmental soil samples 总被引:2,自引:0,他引:2
Zhao R Wang X Yuan J Jiang T Fu S Xu X 《Analytical and bioanalytical chemistry》2006,384(7-8):1584-1589
A novel method of determining organochlorine pesticides (OCPs) is described. It is based on solid-phase microextraction (SPME) and gas chromatography–electron capture detection. During the development of the method, soil samples were prepared, spiked with standard solution, and then aged for some time. Extraction conditions such as the extraction time, the NaCl content, the volume of water, the extraction temperature and the desorption time were investigated and optimized. The limits of detection obtained using the method ranged from 0.10 to 0.51 ng g−1, and relative standard deviations were lower than 10% for most organochlorine pesticides. Real soil samples were successfully analyzed using the proposed method. The results from the method developed here were in good agreement with those obtained using ultrasonic extraction. The result demonstrates that aging soils spiked with standard solution is an important method development step, because the soil samples obtained using this approach are more like real soils than those obtained when aging is not used.
相似文献
18.
This paper described a new approach for the determination of organophosphorus pesticides by temperature-controlled ionic liquid dispersive liquid-phase microextraction prior to high-performance liquid chromatography with ultraviolet detection. Methylparathion and phoxim, two of the typical organophosphorus pesticides, were used as the model analytes for the investigation of the development and application of the new microextraction method. 1-Hexyl-3-methylimidazolium hexafluorophosphate [C6MIM][PF6] was used as the extraction solvent and the factors affecting the extraction efficiency such as the volume of [C6MIM][PF6], pH of working solutions, extraction time, centrifuging time, dissoluble temperature and salt effect were optimized. Under the optimal extraction conditions, methylparathion and phoxim exhibited good linear relationship in the concentration range of 1-100 ng mL(-1). The detection limits were 0.17 ng mL(-1) and 0.29 ng mL(-1), respectively. Precisions of proposed method (RSDs, n=6) were 2.5% and 2.7%, respectively. This proposed method was successfully applied in the analysis of four real environmental water samples and good spiked recoveries over the range of 88.2-103.6% were obtained. These results indicated that temperature-controlled ionic liquid dispersive liquid-phase microextraction had excellent application prospect in environmental field. 相似文献
19.
Sevtap Yigit Mustafa Tuzen Mehmet Dogan 《International journal of environmental analytical chemistry》2016,96(6):568-575
A liquid phase microextraction method-based conformation of supramolecular assembly was developed for the separation and preconcentration of trace levels of Sudan blue II. Various analytical parameters such as pH, supramolecular solvent type and volume, sample volume and matrix effect etc. were optimised. Sudan blue II concentration in the extraction phase was determined by UV-visible spectrophotometer. Under the optimised conditions, detection limit and preconcentration factor was found as 2.16 µg L?1 and 80, respectively. Relative standard deviation value was found 5%. The developed procedure was successfully applied for the determination of trace levels of Sudan blue II in environmental samples. 相似文献
20.
Gallardo E Barroso M Margalho C Cruz A Vieira DN López-Rivadulla M 《Rapid communications in mass spectrometry : RCM》2006,20(5):865-869
A new, simple and rapid procedure for the determination of dimethoate in urine and blood samples was developed using direct immersion solid-phase microextraction and gas chromatography/mass spectrometry. This technique required only 0.1 mL of sample, and ethion was used as internal standard. Two types of coated fibre were compared (100 microm polydimethylsiloxane, and 65 microm Carbowax/divinylbenzene). Other parameters, such as extraction temperature, adsorption and desorption time, salt addition, agitation and pH, were optimized to enhance the sensitivity of the method. Limits of detection (LODs) and quantitation (LOQs) were 50 and 100 ng/mL for urine and 200 and 500 ng/mL for blood, respectively. The method was found to be linear between the LOQ and 40 microg/mL for urine, and between the LOQ and 50 microg/mL for blood, with correlation coefficients ranging from 0.9923-0.9996. Precision (intra- and interday) and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The mean absolute recoveries of dimethoate were 1.24 and 0.50% for urine and blood, respectively. Because of its simplicity and the fact that small volumes of sample are used, the described method can be successfully used in the diagnosis of poisoning by this pesticide, namely in those situations where the sample volume is limited, as frequently occurs in forensic toxicology. 相似文献