首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sample of Baltic amber ( approximately 40 million yrs old) has been extracted using pentane, toluene and 1-methyl-2-pyrrolidinone (NMP). The relationship between solubility characteristics of the extracts in relation to molecular mass and chemical makeup has been investigated. The extracts were first characterised by (13)C-NMR spectrometry, size exclusion chromatography (SEC) and UV-fluorescence spectroscopy. The fractions differed less in terms of chemical structural features than they did in terms of molecular mass. This contrasts markedly with data on fractions of coal-derived liquids, but parallels results from petroleum-derived vacuum residues. In SEC, the toluene soluble/pentane insoluble fraction gave a peak for high mass material at about 67 000 u. Material excluded from the column porosity in this fraction and in NMP solubles eluted between 8 and 11 min, corresponding to polystyrene masses between 200 000 and several million u. A column with a larger pore size distribution was calibrated using polystyrene and polymethylmethacrylate standards with detection by a light-scattering evaporative analyser. The largest polystyrene standard (15.4 million u) eluted at 13.4 min, similar to that of the earliest eluting amber-derived material in the NMP solubles fraction. Results from probe-MS and pyrolysis-GC/MS have been used to confirm the similarity of chemical structures of the three solubility fractions. Broadly, low mass ions appear to correspond to the various monomeric units of structures present in the amber, the higher mass ions to dimer units and the molecular ions to the different combinations of three or more monomeric units. The main monomer groups have been identified in detail, showing a situation very different from that of coal-derived materials, where the sizes of aromatic ring systems increase with molecular size.  相似文献   

2.
The size-exclusion chromatography (SEC) of acetone-soluble, pyridine-soluble and pyridine-insoluble fractions of a coal tar pitch indicates a bimodal distribution in each fraction. The proportion of high-mass material excluded from the SEC column porosity increases with solvent polarity. The polymer calibration of SEC shows the mass range of the small molecules to be from approximately 100 u to approximately 6000 u, with the mass range of the large excluded molecules above 200 000 u and up to several million u. In contrast, matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS) shows a similar low-mass range of ion abundances (< m/z 6000), but with a smaller range of high-mass ion abundances, from approximately m/z 10 000 to 100 000. The large molecules may have three-dimensional structures to allow molecules of relatively low mass to behave as if they are of large size in SEC. Laser desorption mass spectrometry of the acetone- and pyridine-soluble fractions produced molecular ions of polycyclic aromatics that can be related to the known compositions from gas chromatography (GC) mass spectrometry. The experimental conditions used to generate the bimodal distribution by MALDI-MS involve reducing the ion signal intensities to avoid overload of the detector and enable detection of the high-mass ions, by reducing the high-mass detector voltage (i.e. sensitivity) and increasing the laser power.  相似文献   

3.
Soluble, fully cyclized m-amino phenyl acetylene terminated polyimides based on several anhydride/diamine monomers were prepared in N-methylpyrrolidine (NMP) and cyclized by solution imidization to controlled molecular weight. The polyimides and a polyamic acid precursor were successfully analyzed by size exclusion chromatography (SEC) utilizing online parallel coupled refractive index and differential viscometer detectors. The calculated M nvalues were varied from 3,000 to 20,000 daltons. N-methylpyrrolidone (NMP), tetrahydrofuran (THF), and chloroform served as mobile phases for the cross-linked polystyrene gel packings. Normal retention behavior of the polyimides was observed in chloroform, THF, and NMP containing LiBr, or in NMP stirred over P2O5 before use. Values of Mark-Houwink-Sakurada exponents for narrow distribution linear polystyrene indicate that pure NMP and NMP with 0.06 M LiBr are good solvents for polystyrene standards at 60°C. In contrast, SEC behavior of polyimides in pure NMP leads to splitting of the peaks with the major portion observed to pass through the columns at the exclusion limit. In contrast to strong polymeric chain expansion of the polyamic acid in dilute solution, presumably due to a polyelectrolyte effect, no increase of intrinsic viscosity of polyimide samples in pure NMP was observed. This exclusion effect of polyimides analyzed in NMP is discussed in terms of possible ion-exclusion from pores of the stationary phase. Differences in polystyrene calibration in NMP with or without additives and the temperature dependence of calibration curves in these mobile phases is discussed as well. ©1995 John Wiley & Sons, Inc.  相似文献   

4.
Vacuum distillation residues from two petroleum crudes, a coal liquefaction extract and a coal tar pitch have been fractionated by planar chromatography (PC) using two solvent sequences: pyridine–acetonitrile and tetrahydrofuran (THF)–toluene. Fractions recovered from PC were examined by UV-fluorescence spectroscopy (UV-F), size-exclusion chromatography (SEC). UV-F and SEC of the whole samples showed differences in aromatic cluster size and molecular mass (MM) ranges which could be related to the different origins of the samples. The MM ranges indicated by SEC were greater for the vacuum residues than for coal-derived materials. However, the UV-F spectra of the fractions indicated that the petroleum residue fractions contained similar aromatic types, whereas the fractions from coal liquids contained significantly different aromatic types. SEC profiles of the fractions indicated a separation of coal-derived samples by increasing molecular size with increasing immobility in PC, whereas for petroleum fractions, the same trend was not apparent. MALDI-mass spectra of the set of original samples showed broadly similar ranges of MM distributions but additional work is necessary to identify appropriate matrices and procedures in order to improve the MALDI spectra.  相似文献   

5.
Six different soluble high-performance aromatic polyimides, each prepared by solution imidization to three controlled average molecular weights, were analyzed by size exclusion chromatography (SEC) using on-line parallel coupled refractometric and viscometric detectors. N-methylpyrrolidone (NMP) with 0.06 M LiBr and NMP stirred over P2O5 were used as mobile phase for four of the polyimides; NMP with 0.06 M LiBr and NMP stirred over P2O5 were used as mobile phases for four of the polyimides; NMP with 0.06 M LiBr tetrahydrofuran (THF) and chloroform served as mobile phases for the other two polyimides. For all the samples the stationary phase in the SEC columns was cross-linked polystyrene beads. Molecular weight averages of the polyimides were calculated using universal SEC calibration with polystyrene standards in each solvent. The agreement of the calculated molecular weight averages in the different solvents confirms that the universal SEC calibrations are valid for these semiflexible polymers. There was good agreement with weightaverage molecular weights obtained by low-angle laser light scattering (LALLS) performed in pure NMP. Intrinsic viscosity and molecular weight data for a series of nine samples of one polyimide covering a Mw = 20,000–70,000 g mol–1 interval were treated to obtain Mark-Houwink-Sakurada constants. Unperturbed chain dimensions of this polyimide were obtained by application of the Stockmayer-Fixman extrapolation procedure to these data. ©1995 John Wiley & Sons, Inc.  相似文献   

6.
The structural characterisation of a coal liquefaction extract and its three fractions separated by planar chromatography has been described. Size exclusion chromatography showed the molecular mass distributions to become progressively larger with decreasing mobility on the plate. UV-fluorescence spectroscopy of the fractions indicated parallel increases in the sizes of polynuclear aromatic ring systems. Analysis by probe-mass spectrometry of the 'whole' coal extract showed the expected array of small polynuclear aromatic groups extending to m/z 450. The probe mass spectra of the lightest fraction ('mobile in pyridine and acetonitrile') showed similar features, except for effects due to vacuum drying to remove solvent. In sharp contrast, the two heaviest fractions ('mobile in pyridine and immobile in acetonitrile' and 'immobile in pyridine') showed no significant ions other than those from residual NMP solvent (m/z 98 and 99). Pyrolysis-gas chromatography/mass spectrometry of these two heaviest fractions showed only traces of aromatic compounds or fragments. The aromatic pyrolysis products of these fractions were too large and involatile to pass through the GC column. The major components observed in the pyrolysis-gas chromatography/mass spectrometry of the two heavy fractions were alkanes and alkenes, ranging between C10-C25. Since none of the samples contained free alkanes, alkenes or cycloalkanes before pyrolysis, they were generated during the pyrolysis step. The shifts of UV-fluorescence spectral intensity to shorter wavelengths with decreasing size indicated by size exclusion chromatography (SEC) provide direct evidence of differences in structure with changing molecular mass. This evidence strongly suggests that species identified as being of large molecular mass in this extract sample are not composed of molecular aggregates. It remains difficult to establish whether and when it would be legitimate to invoke molecular aggregates to explain the large molecular masses (MMs) identified here and in other work. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

7.
With the increasing popularity of evaporative interfaces, detection using Fourier Transform Infrared (FTIR) spectrometry in the mid-infrared region is becoming more important in size-exclusion chromatography (SEC). FTIR spectrometry is a powerful, and potentially very widely applicable, method for obtaining chemical functional group information for each molecular size fraction. Quantitative evaluation of polymer composition across the SEC chromatogram can provide more accurate characterization of heterogeneous polymer samples for problem solving and for material specification. The evaporative interface removes the SEC mobile phase at the exit of the column and deposits the eluting polymer as a continuous film stripe or as a series of discrete films on infrared transparent substrates. Initially this detection approach was used only for qualitative analysis. More recently, it is being used quantitatively. Previously we demonstrated that the quality of the film generated by the evaporative interface was critical to determining the suitability of the resulting FTIR spectra for quantitative analysis. In a continuation of this work, the objective of this paper is to develop a procedure for obtaining valid quantitative results for polymer blends with the interface. Experimental topics include improving the quality of polymer films by post-SEC treatments, off-line FTIR calibrating using other means to obtain high quality polymer films, and utilizing in-line SEC detectors in calibration. Interpretation aspects focus upon peak fitting of FTIR spectra, linear regression, partial least squares, and data pre-processing. PLS prediction with internal calibration using the second derivative of solvent-annealed film spectra was found to provide the best compromise between processing time, accuracy and precision.  相似文献   

8.
We explore the use of preparative size-exclusion chromatography (SEC) and high-performance liquid chromatography (HPLC) to purify quantum dots (QDs) after surface modification. In one example, in which Bio-Beads (S-X1) were used as the packing material for the preparative SEC column, CdSe QDs treated with a functional coumarin dye could be separated from the excess free dye by using tetrahydrofuran (THF) as the mobile phase. This column was unable to separate polymer-coated QDs from free polymer (M ∼ 8000) because of the relatively low cutoff mass of the column. Here a preparative HPLC column packed with TOYOPEARL gel allowed the effective separation of polymer-bound QDs from the excess free polymer by using N-methyl-2-pyrrolidinone (NMP) as the mobile phase. When other solvents such as absolute ethanol, acetonitrile, THF, and THF–triethylamine mixtures were used as the eluent, QDs stuck to the column. While NMP was an effective medium to remove excess free polymer from the QDs, it was difficult to transfer the purified QDs to more volatile solvents and maintain colloidal stability.  相似文献   

9.
Summary The suitability of flash chromatography for the fractionation of coal liquids in compound classes has been studied. TLC data obtained from standards were used for establishing the sequence, composition and volume of eluents in order to collect the main components of coal liquids in six fractions of increasing polarity. The method was tested by the fractionation of a SCG coal extract and separations were evaluated by TLC, SEC, and IR and NMR spectroscopy.  相似文献   

10.
A more complete understanding of the raw materials used for making implant device materials becomes increasingly important in the medical device industry. Often such detailed information requires utilization of a combination of analytical techniques. In this work, we characterize a poly(dimethyl siloxane) (PDMS) material using on-line size exclusion chromatography (SEC) with electrospray ionization (ESI) and matrix assisted laser desorption ionization (MALDI) mass spectrometry (MS) techniques. Here, we obtain detailed molecular compositional information such as repeat units, end group chemistry, and identification of impurities in both the high and low mass range. SEC with light scattering, viscosity, and refractive index detection (triple detection) is used to obtain information on a small quantity of high mass impurity that was undetected by both SEC-ESI and MALDI MS techniques. SEC with triple detection measures absolute molecular weights and molecular weight distributions. We compare average molecular weight values of the implantable device polymer obtained by SEC with triple detection, SEC-ESI, and SEC-MALDI MS techniques.  相似文献   

11.
In size-exclusion chromatography (SEC), proteins and peptides are separated according to their molecular size in solution. SEC is especially useful as an effective fractionation step to separate a vast amount of impurities from the components of interest and/or as final step for the separation of purified proteins from their aggregates, in a so-called polishing step. However, the throughput in SEC is low compared to other chromatographic processes as good resolution can be achieved only with a limited feed volume (i.e., maximal approximately 5% of the column volume can be loaded). This limitation opposed widespread application of conventional SEC in industry despite its excellent separation potential. Therefore a continuous separation process (namely preparative continuous annular chromatography) was developed and compared to a conventional SEC system both using Superdex 200 prep grade as sorbent. An immunoglobulin G sample with a high content of aggregates was chosen as a model protein solution. The influence of the feed flow-rate, eluent flow-rate and rotation rate on the separation efficiency was investigated. The height equivalent to a theoretical plate was lower for preparative continuous annular chromatography which could be explained by reduced extra column band broadening. The packing quality was proved to be identical for both systems. The productivity of conventional batch SEC was lower compared to continuous SEC, consequently buffer consumption was higher in batch mode.  相似文献   

12.
The molecular weight of unfractionated heparin was determined by size exclusion chromatography (SEC) coupled with multiangle light scattering (MALS) detection. The SEC/MALS method determines absolute molecular weight directly from the angular dependence of scattered light intensity as a function of concentration and does not rely on molecular weight standards for column calibration. The SEC/MALS method developed at Scientific Protein Laboratories was qualified in terms of specificity, precision, robustness, and accuracy. By eliminating the requirement of well-characterized molecular weight standards derived from heparin, the present procedure represents a clear improvement over the column calibration methods used in molecular weight determination. The SEC/MALS method is suitable for routine quality control of unfractionated heparin.  相似文献   

13.
A general stochastic theory of size exclusion chromatography (SEC) able to account for size dependence on both pore ingress and egress processes, moving zone dispersion and pore size distribution, was developed. The relationship between stochastic-chromatographic and batch equilibrium conditions are discussed and the fundamental role of the 'ergodic' hypothesis in establishing a link between them is emphasized. SEC models are solved by means of the characteristic function method and chromatographic parameters like plate height, peak skewness and excess are derived. The peak shapes are obtained by numerical inversion of the characteristic function under the most general conditions of the exploited models. Separate size effects on pore ingress and pore egress processes are investigated and their effects on both retention selectivity and efficiency are clearly shown. The peak splitting phenomenon and peak tailing due to incomplete sample sorption near to the exclusion limit is discussed. An SEC model for columns with two types of pores is discussed and several effects on retention selectivity and efficiency coming from pore size differences and their relative abundance are singled out. The relevance of moving zone dispersion on separation is investigated. The present approach proves to be general and able to account for more complex SEC conditions such as continuous pore size distributions and mixed retention mechanism.  相似文献   

14.
A method for characterizing very large, water-soluble polymers by size exclusion chromotography (SEC) has been developed. Sephacryl S1000 packing material, a precision syringe pump, and an eluent pressure detector have been utilized to produce highly accurate chromatograms of polymers having molecular hydrodynamic diameters up to 250 nm. Previous SEC analysis has been limited to polymers having hydrodynamic diameters of less than 120 nm.  相似文献   

15.
Columns switch recycling size exclusion chromatography (csrSEC) was proposed to achieve high resolution protein separation with good biocompatibility. Proteins were firstly separated by two serially coupled SEC columns, and fractions were in sequence switched back to the first column by two-position valves for further separation in terms of close-loop recycling until satisfactory resolution was achieved. Compared to SEC, the separation window was broadened by increasing column length via cycling without further increase on back pressure. Compared to recycling SEC (rSEC), the overtaking of later eluted components by early eluted ones after several cycles could be avoided for complex sample analysis, by parking fractions in the second SEC column before transferred in turn back to the first one for cycling ordinally. In our experiments, the baseline separation of five proteins with molecular weight ranging from 10 kDa to 80 kDa was achieved by csrSEC. Furthermore, a multidimensional csrSEC–RPLC platform was constructed, and peak capacity up to 3600 was obtained for protein separation. All these results demonstrated that csrSEC is a promising protein separation mode with good biocompatibility, broadened separation window and improved resolution.  相似文献   

16.
A more complete understanding of polymeric, cationic cellulose derivatives, including polyquaterium-10 (Polymer JR), has become increasingly important in the eye care industry as thorough characterization of raw materials helps promote product quality and process control. Often such detailed information requires utilization of a combination of analytical techniques. In this work three Polymer JR samples with different viscosities were characterized using aqueous size exclusion chromatography (SEC) with a light scattering detector, a differential viscometer, and a differential refractometer (triple detection). Detailed molecular information such as absolute molecular weights, molecular weight distributions, intrinsic viscosities, and molecular conformations were obtained. One major challenge of analyzing cationic polymers is abnormal size exclusion separation, which could be caused by the ionic interaction between sample molecules and the column packing material. A selection of mobile phases varying in pH, buffer, organic solvent content, and molar concentration of salts was employed to evaluate the correlation of obtained molecular weight values and mobile phase composition. Universal calibration concept was used to examine the abnormal size exclusion separation phenomenon of Polymer JR samples when using different mobile phases. It was observed that the abnormal size exclusion was dependent on both the separation conditions and molecular weights of the samples. Despite the changes in separation parameters and uncharacteristic polymeric structure compared to conventional SEC samples, the use of aqueous SEC with triple detection provided reproducible and valuable molecular information of Polymer JR samples with low to medium molecular weights. By using a combination of high buffer content and adding organic solvent, the abnormal exclusion separation of high molecular weigh Polymer JR could be considerably reduced.  相似文献   

17.
The high-temperature gas chromatographic (GC) separation of several semivolatile compounds is studied with a short metal capillary column packed with fibrous material, having a polydimethylsiloxane coating thereon. Taking advantage of the excellent heat-resistance of the fiber and also the combination of the surface-deactivated metal capillary, a temperature-programmed separation up to 450 degrees C is successfully demonstrated for the separation of polymer standard samples. The average molecular weight of the commercially-available polymer standard samples for size exclusion chromatography (SEC) is estimated by high-temperature GC analysis and compared with the nominal value determined by a conventional SEC method. Although a slight deviation for the number-average molecular weight is observed between the GC and SEC analysis, the data for the weight-average molecular weight shows a good agreement in these methods. The results also suggest the future possibility of the fiber-packed metal capillary as a miniaturized GC column with an increased sample loading capacity.  相似文献   

18.
Complex, multicomponent mixtures are difficult to separate in a single chromatographic run. Therefore, the possibility to separate twelve coumarins from Archangelica officinalis was studied by combining a HPLC and a TLC system. HPLC optimized by the use of DryLab for Windows software was performed on RP-18 column and TLC was performed on silica plates. Fractions from the RP column were evaporated, applied on silica plate and developed in non-aqueous solvent. Possibilities of complete separation of investigated coumarins were discussed in RP and NP systems. The result of their complete separation was presented by HPLC chromatograms, DryLab simulated chromatograms and a video scan of TLC plate.  相似文献   

19.
Size-exclusion chromatography (SEC) has been widely used to detect antibody aggregates, monomer, and fragments. SEC coupled to mass spectrometry has been reported to measure the molecular weights of antibody; antibody conjugates, and antibody light chain and heavy chain. In this study, separation of antibody light chain and heavy chain by SEC and direct coupling to a mass spectrometer was further studied. It was determined that employing mobile phases containing acetonitrile, trifluoroacetic acid, and formic acid allowed the separation of antibody light chain and heavy chain after reduction by SEC. In addition, this mobile phase allowed the coupling of SEC to a mass spectrometer to obtain a direct molecular weight measurement. The application of the SEC-MS method was demonstrated by the separation of the light chain and the heavy chain of multiple recombinant monoclonal antibodies. In addition, separation of a thioether linked light chain and heavy chain from the free light chain and the free heavy chain of a recombinant monoclonal antibody after reduction was also achieved. This optimized method provided a separation of antibody light chain and heavy chain based on size and allowed a direct measurement of molecular weights by mass spectrometry. In addition, this method may help to identify peaks eluting from SEC column directly.  相似文献   

20.
Summary Copolymers of styrene and ethyl methacrylate have been separated according to composition by gradient HPLC on silica columns or CN bonded phase columns. This mode of separation according to composition was applied to fractions obtained by size exclusion chromatography (SEC). From viscosity and molecular mass data of copolymers with a styrene content ranging from 7.5 to 95.3 mass-% it can be concluded that SEC separates mainly by molecular mass even in this copolymer system. Thus, chromatographic cross-fractionation is possible by prefractionation by SEC and subsequent separation according to composition by gradient HPLC.
Untersuchung von Copolymeren von Styrol und Ethylmethacrylat durch Ausschluß-Chromatographie und Gradienten-HPLC
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号