首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Given the potential risks of chlorinated polycyclic aromatic hydrocarbons, the analysis of their presence in water is very urgent. We have developed a novel procedure for determining chlorinated polycyclic aromatic hydrocarbons in water based on solid‐phase extraction coupled with gas chromatography and mass spectrometry. The extraction parameters of solid‐phase extraction were optimized in detail. Under the optimal conditions, the proposed method showed wide linear ranges (1.0–1000 ng/L) with correlation coefficients ranging from 0.9952 to 0.9998. The limits of detection and the limits of quantification were in the range of 0.015–0.591 and 0.045–1.502 ng/L, respectively. Recoveries ranged from 82.5 to 102.6% with relative standard deviations below 9.2%. The obtained method was applied successfully to the determination of chlorinated polycyclic aromatic hydrocarbons in real water samples. Most of the chlorinated polycyclic aromatic hydrocarbons were detected and 1‐monochloropyrene was predominant in the studied water samples. This is the first report of chlorinated polycyclic aromatic hydrocarbons in water samples in China. The toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in the studied tap water were 9.95 ng the toxic equivalency quotient m?3. 9,10‐Dichloroanthracene and 1‐monochloropyrene accounted for the majority of the total toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in tap water.  相似文献   

2.
This study presents the optimization and application of an analytical method based on the use of stir bar sorptive extraction (SBSE) gas chromatography coupled to mass spectrometry (GC–MS) for the ultra-trace analysis of POPs (Persistent Organic Pollutants) in Arctic ice. In a first step, the mass-spectrometry conditions were optimized to quantify 48 compounds (polycyclic aromatic hydrocarbons, brominated diphenyl ethers, chlorinated biphenyls, and organochlorinated pesticides) at the low pg/L level. In a second step, the performance of this analytical method was evaluated to determine POPs in Arctic cores collected during an oceanographic campaign. Using a calibration range from 1 to 1800 pg/L and by adjusting acquisition parameters, limits of detection at the 0.1–99 and 102–891 pg/L for organohalogenated compounds and polycyclic aromatic hydrocarbons, respectively, were obtained by extracting 200 mL of unfiltered ice water. α-hexachlorocyclohexane, DDTs, chlorinated biphenyl congeners 28, 101 and 118 and brominated diphenyl ethers congeners 47 and 99 were detected in ice cores at levels between 0.5 to 258 pg/L. We emphasise the advantages and disadvantages of in situ SBSE in comparison with traditional extraction techniques used to analyze POPs in ice.  相似文献   

3.
Decomposition of chlorobenzene as a model molecule of aromatic chlorinated compounds was studied in radiofrequency thermal plasma both in neutral and oxidative conditions. Optical emission spectroscopy was applied for the evaluation of the plasma excitation and molecular rotational-vibrational temperature. Atomic (C, H, O) and molecular (CH, OH, C2) radicals were identified, while the morphology of the formed soot was characterized by electron microscopy. Organic compounds adsorbed on the surface of the soot after plasma processing were comprised of various polycyclic aromatic hydrocarbons (PAH) and chlorinated PAH molecules. Their amount was greatly affected by experimental conditions, especially the oxygen content and plate power. The higher input power reduced the ring number of the PAH molecules. Addition of oxygen significantly reduced the amount of both PAHs chlorinated PAH molecules but enhanced the formation of polychlorinated benzene compounds.  相似文献   

4.
We have evaluated an analytical method for the determination of polycyclic aromatic hydrocarbons (PAHs) and sulfur compounds in air by means of adsorption/temperature-programmed thermal desorption (ATPTD) with small bed volume (0.08g) Tenax-TA cartridges, followed by a cryogenic trap in a precolumn with liquid nitrogen as an appropriate concentration method before capillary gas chromatography is described. The enriched components from the adsorption cartridges are transferred to the capillary column with a valveless switching system. Recoveries were determined for the complete ATPTD method. Desorption recoveries near 100% were found for various of polycyclic aromatic hydrocarbons and sulfur compounds. The sulfur compounds known to cause nuisance odors in the atmosphere near sulfur recovery and sewerage treatment works were also determined.  相似文献   

5.
Jinno  K.  Nakamura  H. 《Chromatographia》1994,39(5-6):285-293
Summary Fluorinated bonded silica has been evaluated as a packing material in reversed-phase liquid chromatography (RPLC) with polycyclic aromatic hydrocarbons, chlorinated benzenes and substituted benzenes as sample probes. The bonded material is useful as a reversed-phase stationary phase and for polar compounds it offers a specific selectivity not found with octadecylsilica (ODS) phases. The phase also retains non-planar compounds more than planar molecules. The results can be explained by conformational differences between ODS and the fluorinated bonded phase by MM2 calculation.  相似文献   

6.
A technique was developed for the sorption preconcentration of polycyclic aromatic hydrocarbons on polyurethane foams in the batch and dynamic modes providing their simultaneous quantitative extraction. A procedure was proposed for screening waters for polycyclic aromatic hydrocarbons based on the preconcentration of these compounds with polyurethane foam, determination of their total amount by the luminescence method, desorption of adsorbed compounds with acetonitrile, and determination of individual compounds in the eluate by high-performance liquid chromatography with fluorescence detection. The procedure was tested with model and real samples of water.  相似文献   

7.
The agronomic benefit of biochar has attracted widespread attention to biochar‐based fertilizers. However, the inevitable presence of polycyclic aromatic hydrocarbons in biochar is a matter of concern because of the health and ecological risks of these compounds. The strong adsorption of polycyclic aromatic hydrocarbons to biochar complicates their analysis and extraction from biochar‐based fertilizers. In this study, we optimized and validated a method for determining the 16 priority polycyclic aromatic hydrocarbons in biochar‐based fertilizers. Results showed that accelerated solvent extraction exhibited high extraction efficiency. Based on a Box–Behnken design with a triplicate central point, accelerated solvent extraction was used under the following optimal operational conditions: extraction temperature of 78°C, extraction time of 17 min, and two static cycles. The optimized method was validated by assessing the linearity of analysis, limit of detection, limit of quantification, recovery, and application to real samples. The results showed that the 16 polycyclic aromatic hydrocarbons exhibited good linearity, with a correlation coefficient of 0.996. The limits of detection varied between 0.001 (phenanthrene) and 0.021 mg/g (benzo[ghi]perylene), and the limits of quantification varied between 0.004 (phenanthrene) and 0.069 mg/g (benzo[ghi]perylene). The relative recoveries of the 16 polycyclic aromatic hydrocarbons were 70.26–102.99%.  相似文献   

8.
Detection of monohydroxy polycyclic aromatic hydrocarbons metabolites in urine is an advisable and valid method to assess human environmental exposure to polycyclic aromatic hydrocarbons. In this work, novel Fe3O4/graphene oxide composites were prepared and their application in the magnetic solid‐phase extraction of monohydroxy polycyclic aromatic hydrocarbons in urine was investigated by coupling with liquid chromatography and mass spectrometry. In the hybrid material, superparamagnetic Fe3O4 nanoparticles provide fast separation to simplify the analytical process and graphene oxide provides a large functional surface for the adsorption. The prepared magnetic nanocomposites were characterized by X‐ray diffraction, scanning electron microscopy, transmission electron microscopy, and vibrating sample magnetometry. The experimental conditions were optimized systematically. Under the optimal conditions, the recoveries of these compounds were in the range of 98.3–125.2%, the relative standard deviations ranged between 6.8 and 15.5%, and the limits of detection were in the range of 0.01–0.15 ng/mL. The simple, quick, and affordable method was successfully used in the analysis of human urinary monohydroxy polycyclic aromatic hydrocarbons in two different cities. The results indicated that the monohydroxy polycyclic aromatic hydrocarbons level in human urine can provide useful information for environmental exposure to polycyclic aromatic hydrocarbons.  相似文献   

9.
Steel stirrers jacketed with polytetrafluoroethylene can be regarded as an ideal substrate for stirrer bar sorptive extraction. However, it is still a great challenge to immobilize graphene onto a polytetrafluoroethylene stirrer due to the high chemical resistance of the surface of a polytetrafluoroethylene stirrer. We describe here a method to modify the surface of polytetrafluoroethylene stirrers with graphene. In this work, graphene was used as the sorbent due to its excellent adsorption capability for aromatic compounds, such as polycyclic aromatic compounds. Graphene was successfully immobilized onto polytetrafluoroethylene‐stirrer by a bio‐inspired polydopamine functionalization method. The graphene‐modified polytetrafluoroethylene‐stirrer shows good stability and tolerance to stirring, ultrasonication, strong acidic and basic solutions, and to organic solvents. The multilayer coating was characterized by scanning electronic microscopy and Fourier transform infrared spectroscopy. After the optimization of some experimental conditions, the graphene‐modified polytetrafluoroethylene stirrer was used for the stirrer bar sorptive extraction of polycyclic aromatic hydrocarbons, in which the binding between the polycyclic aromatic hydrocarbons and the graphene layer was mainly based on π–π stacking and hydrophobic interactions. The graphene‐modified polytetrafluoroethylene‐stirrer‐based stirrer bar sorptive extraction and high‐performance liquid chromatography method was developed for the determination of polycyclic aromatic hydrocarbons with great extraction efficiency, with enrichment factors from 18 to 62. The method has low limits of detection of 1–5 pg/mL, wide linear range (5–100 and 10–200 pg/mL), good linearity (R ≥ 0.9957) and good reproducibility (RSD ≤ 6.45%). The proposed method has been applied to determine polycyclic aromatic hydrocarbons in real dust samples. Good recoveries were obtained, ranging from 88.53 to 109.43%.  相似文献   

10.
SRM 1941a, Organics in Marine Sediment, has been recently issued with certified concentrations for 23 polycyclic aromatic hydrocarbons, 21 polychlorinated biphenyl congeners, 6 chlorinated pesticides, and sulfur. Noncertified concentrations have been also reported for additional PAHs, PCB congeners, and chlorinated pesticides and for percent total organic carbon (TOC), aliphatic hydrocarbons, and trace elements. SRM 1941a is the most extensively characterized natural matrix SRM issued by the National Institute of Standards and Technology (NIST).  相似文献   

11.
This article introduces a simple, rapid, and reliable solid‐phase microextraction (SPME) method coupled with GC‐MS for the quantitative determination of 16 polycyclic aromatic hydrocarbons in water. In this study, the Taguchi experimental design was used to optimize extraction conditions of polycyclic aromatic hydrocarbons using SPME method to obtain highly enriched analytes. Consequently, quantitative determination of polycyclic aromatic hydrocarbons in water was achieved by GC‐MS technique. The selected parameters affecting enrichment of polycyclic aromatic hydrocarbons were sample extraction time, stirring speed, temperature, ionic strength, and pH. The study revealed that optimal operating conditions were found to be 90‐min extraction time, 1400 rpm stirring speed, and 60°C sample temperature. The effect of ionic strength and pH were shown to be insignificant. Optimized conditions were also reevaluated by placing the 16 polycyclic aromatic hydrocarbons into several subgroups based on their molecular weight. The extraction efficiency of polycyclic aromatic hydrocarbons with low molecular weight was shown to be a function of only the extracting temperature. Satisfactory results were obtained for linearity (0.983–0.999), detection limits (2.67–18.02 ng/L), accuracy (71.2–99.3%), and precision (4.3–13.5%). The optimum conditions reported by other design approaches were evaluated and generalized optimum conditions were suggested.  相似文献   

12.
Coupled liquid chromatography – gas chromatography – mass spectrometry (LC-GC-MS) has been applied for on-line clean up, separation, and identification of chlorinated polycyclic aromatic hydrocarbons (CI-PAHs). A loop-type interface was used to couple the liquid chromatograph on-line with the GC-MS, and concurrent solvent evaporation was used for sample transfer. A back-flush technique was used in conjunction with a two-dimensional column system for isolation of CI-PAHs and polycyclic aromatic hydrocarbons (PAHs). This fraction was transferred on-line to the GC and separated on a capillary column. Selective and sensitive detection of CI-PAHs in the GC eluate was obtained by negative ion chemical ionization (NICI) mass spectrometry and selected ion monitoring (SIM). The combined on-line system for isolation, separation, and identification showed high precision and accuracy, and demonstrated a linear response from 1 to 1000 pg for chlorinated PAHs. The estimated detection limit was 250 fg for 1-chloropyrene and 1,6-dichloropyrene. The technique was demonstrated by analysis of urban air samples. The low detection limit made it possible to use the technique for analysis of personally carried monitoring equipment for measurement of exposure to CI-PAHs in the work environment.  相似文献   

13.
A novel organic–inorganic composite-coated fiber was developed for selective solid-phase microextraction (SPME) by direct electrodeposition of zinc oxide microparticles on a pretreated stainless steel wire followed by self-assembly of hydroxyundecanethiol with zinc–sulfur bonds. The performance of the hydroxyundecyl-modified zinc oxide-coated steel fiber was then assessed for SPME of polar aromatic compounds coupled to high-performance liquid chromatography with ultraviolet detection. Excellent extraction and selectivity were obtained for polycyclic aromatic hydrocarbons. The extraction and desorption times, temperature, stirring rate, and ionic strength were optimized. The limits of detection were from 0.034 to 0.132?µg?L?1. The relative standard deviations were from 3.4 to 4.9% for a single fiber and from 5.1 to 6.4% for multiple fibers. The recovery of polycyclic aromatic hydrocarbons in environmental water fortified at 5.0 and 50?µg?L?1 was from 83.1 to 103% with relative standard deviations below 8.4%. This fiber was shown to withstand at least 200 extraction and desorption cycles. The method was used for the preconcentration and determination of polycyclic aromatic hydrocarbons in environmental water.  相似文献   

14.
This paper describes the determination of Henry's law coefficients by means of the EPICS (equilibrium partitioning in closed systems) technique in combination with SPME (solid-phase microextraction). The use of solid-phase microextraction-sampling allowed us to extend the possibilities of the equilibrium partitioning in closed systems technique with respect to the range of Henry's law coefficients which can be measured. Whereas the equilibrium partitioning in closed systems technique is limited to determine air–water equilibrium partitioning of volatile compounds with Henry's law coefficients of at least 0.06 (dimensionless), the current method allowed to measure coefficients between 0.0023 and 13.5. In this way Henry's law coefficients of 20 compounds, being in a range covering five orders of magnitude, were measured with relative standard deviations between 1.0 and 19.8% (mean standard deviation: 5.7%; median of standard deviations: 4.8%, n=99). Several types of compounds were examined i.e. aliphatic hydrocarbons, monocyclic and polycyclic aromatic hydrocarbons, chlorinated and fluorinated compounds, ethers and esters, biphenyl and N-containing compounds, including compounds for which availability of experimental Henry's law coefficients is limited. Measurement of the equilibrium partitioning in the 2 to 25°C range allowed to establish relations of Henry's law coefficient as a function of temperature.  相似文献   

15.
The new membrane-enclosed silicone collector (MESCO) was, in two different configurations with respect to the thickness of low-density polyethylene membrane used, subject to serial batch extraction tests to obtain (preliminary) sampling rates for estimating water concentrations of selected chlorinated organic compounds and polycyclic aromatic hydrocarbons. This rapid calibration procedure is simple to implement compared to experiments in a flow-through apparatus and yielded reasonable sampling rates in the range of 50 microL-2 mL per hour for the compounds tested. The new MESCO formats were also exposed for 28 days in the polluted creek to test their field performance. For priority contaminants of special interest, alpha-hexachlorocyclohexane and hexachlorobenzene, the time-weighted average concentrations derived from the freshly calibrated sampling devices agree well with those obtained by conventional water analysis of spot samples.  相似文献   

16.
We propose a method for the simultaneous determination of 15 kinds of polycyclic aromatic hydrocarbons in marine samples (muscle) employing gas chromatography with mass spectrometry after saponification with ultrasound‐assisted extraction and solid‐phase extraction. The experimental conditions were optimized by the response surface method. In addition, the effects of different lyes and extractants on polycyclic aromatic hydrocarbons extraction were discussed, and saturated sodium carbonate was first used as the primary saponification reaction and extracted with 10 mL of ethyl acetate and secondly 1 mol/L of sodium hydroxide and 10 mL of n‐hexane were used to achieve better results. The average recovery was 67–112%. Satisfactory data showed that the method has good reproducibility with a relative standard deviation of <13%. The detection limits of polycyclic aromatic hydrocarbons were 0.02–0.13 ng/g. Compared with other methods, this method has the advantages of simple pretreatment, low solvent consumption, maximum polycyclic aromatic hydrocarbons extraction, the fast separation speed, and the high extraction efficiency. It is concluded that this method meets the batch processing requirements of the sample and can also be used to determine polycyclic aromatic hydrocarbons in other high‐fat (fish, shrimp, crab, shellfish) biological samples.  相似文献   

17.
Abstract

The trace organic pollutants in the Yellow River enriched by a solvent extraction method were pre-separated into four different fractions of fatty hydrocarbons, polycyclic aromatic hydrocarbons, polar compounds and organic acids and were analyzed by the use of combined capillary column gas chromatography-mass spectrometry. Using the combined techniques of relative retention value, mass spectra and mass chromatogram, more than 60 organic pollutants were identified, among which 16 fatty hydrocarbons and 6 polycyclic aromatic hydrocarbons which were quantitatively analyzed. The concentration range of fatty hydrocarbon was 5–800 ng/l, and that of polycyclic aromatic hydrocarbon was 0-90ng/l.  相似文献   

18.
Summary An LC clean-up procedure based upon a complexation between polycyclic aromatic hydrocarbons (PAHs) and silica with chemically bonded 2,4-dinitroaniline has been combined with GC/MS. The LC pre-separation makes it possible to obtain a relatively clean fraction of PAHs free from alkanes, alkylbenzenes and naphthalenes, PCBs, chlorinated pesticides and many other interfering compounds. This fraction has been analyzed using capillary GC and mass selective detector (MSD). Substantial improvement of the MS spectra of PAHs with three or more fused benzene rings is achieved.  相似文献   

19.
Guo K  Zhou J  Liu Z 《色谱》2012,30(2):128-134
通过对升温速度、二维补偿温度、调制周期等关键实验参数的优化,建立了全二维气相色谱-飞行时间质谱(GC×GC-TOF MS)分析重馏分油中芳烃组分的方法,得到了重馏分油芳烃组分按环数分布的二维点阵图。根据谱库检索、标准化合物对照及文献报道,对重馏分油芳烃组分中菲、甲基菲及芘、苯并蒽等常见多环芳烃(PAH)进行了准确定性,并将该方法应用到重馏分油加氢处理工艺研究中,对菲、芘的加氢处理产物进行了定性分析。该研究为重馏分油芳烃组分的准确定性提供了新的技术手段,为加深对油品加氢规律的认识提供了技术支持。全二维气相色谱与普通一维色谱对比,在重馏分油的芳烃组分分析上体现了极大优势。  相似文献   

20.
An analytical method for the quantitative determination of neutral and acidic lipid biomarkers in particulate and sediment samples has been developed. The method involves a first step with solvent extraction to isolate the neutral from the acidic compounds and a second step using normal-phase HPLC on a Nucleosil silica column to separate four different classes of neutral compounds: (1) aliphatic hydrocarbons, (2) aromatic hydrocarbons, (3) ketone compounds and (4) sterol and alcohol compounds. Recoveries of the individual spiked lipid biomarkers for the whole analytical procedure ranged from 88 to 106% for fatty acids, from 50 to 60% for aliphatic hydrocarbons (> or = n-C17), from 50 to 60% for polycyclic aromatic hydrocarbons (PAHs) (> or = 3 rings), 83% for friedelin and 60-80% for the sterol and alcohol compounds. The isolated compound classes were analysed by gas chromatography-combustion-isotope ratio mass spectrometry to measure the stable carbon isotope ratios in the individual compounds. The method enables the isolation of compound classes without fractionation for compound-specific carbon isotope analysis (delta13C). This analytical protocol has been applied, and proved suitable, for the determination of lipid biomarkers (sterols, fatty alcohols and fatty acids) in marine particulate material and for the determination of PAHs in sediment samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号