首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An attempt was made to produce calcium containing plasma electrolytic oxidation (PEO) coatings on AM50 magnesium alloy using an alkaline electrolyte. This study was performed in three alkaline electrolytes containing calcium hydroxide and sodium phosphate with three different mass ratios viz., 1:2.5, 1:5 and 1:7.5. All the three coatings produced were found to contain Ca and P in appreciable amounts. The concentration of P was found to be higher in the coatings obtained in the electrolytes with higher concentration of phosphate ions. Even though all the three coatings were found to be constituted with magnesium oxide and magnesium phosphate phases, X-ray diffraction analyses revealed that the phase composition was influenced by the phosphate ion concentration/conductivity of the electrolyte. Further, the PEO coating obtained in the 1:7.5 ratio electrolyte was found to contain di-calcium phosphate (monetite) and calcium peroxide phases, which were absent in the other two coatings. Potentiodynamic polarization studies performed in 0.1 M NaCl solution showed that the coatings obtained from the 1:5 ratio electrolyte possessed a superior corrosion resistance, which is attributed to the combined effect of thickness, compactness and phase/chemical composition of this coating.  相似文献   

2.
Plasma electrolytic oxidation (PEO) of an AM50 magnesium alloy was accomplished in a silicate-based electrolyte using a DC power source. Coatings were produced at three current densities, i.e. 15 mA cm−2, 75 mA cm−2, and 150 mA cm−2 and were characterised for thickness, roughness, microstructural morphology, phase composition, and corrosion resistance. Even though the 15 min treated coatings produced at higher current density levels were thicker, they showed poor corrosion resistance when compared to that of the coatings obtained at 15 mA cm−2. Short-term treatments (2 min and 5 min) at 150 mA cm−2 yielded coatings of thickness and corrosion resistance comparable to that of the low current density coatings. The superior corrosion resistance of the low thickness coatings is attributed to the better pore morphology and compactness of the layer.  相似文献   

3.
Two types of PEO coatings, one consisting of magnesium oxide (MgO) and the other comprising zirconium oxide (ZrO2) as the main phase composition were produced on AM50 magnesium alloy from alkaline and acidic electrolytes, respectively. The ZrO2 coating was found to be spongy and thicker with a higher roughness, whilst the relatively more compact MgO coating was having contrasting features. In the dry sliding oscillating wear tests under two different loads viz., 2 N and 5 N, the ZrO2 coating exhibited a very poor wear resistance. The MgO coating showed an excellent resistance to sliding wear under 2 N load; however, the load bearing capacity of the coating was found to be insufficient to resist the wear damage under 5 N load. The higher specific wear rates of the MgO coating under 5 N load and that of the ZrO2 coating under 2 N and 5 N loads were attributed to the poor load bearing capacity and a three-body-abrasive wear mechanism.  相似文献   

4.
Ceramic coatings on the surfaces of Mg-9Al-1Zn (AZ91) magnesium alloy and Mg-9Al-1Zn-1Nd magnesium alloy (AZ91 magnesium alloy modified by neodymium, named as AZ91Nd in this paper) are synthesized in aluminate electrolyte by plasma electrolytic oxidation (PEO) process, respectively. X-ray diffraction and X-ray photoelectron spectroscopy analyses show the PEO coating on the Mg-9Al-1Zn-1Nd alloy comprises not only MgO and Al2O3, which are found in the coating on the AZ91 alloy, but also a trace amount of Nd2O3. Microstructure observations indicate the addition of Nd can decrease the sizes of β phases and form Al2Nd intermetallics in the AZ91 alloy. The fine β phases can effectively restrain the formation of unclosed-holes and greatly decrease the sizes of pores in the coating during the PEO process. In addition, the Al2Nd intermetallics can be completely covered due to the lateral growth of the PEO coatings formed on the α and β phases. As a result, the coating on the AZ91Nd alloy possesses a dense microstructure compared with that on the AZ91 alloy. The following corrosion tests indicate the corrosion resistance of the PEO coating on the AZ91Nd alloy is evidently higher than that of the PEO coating on the AZ91 alloy.  相似文献   

5.
The influence of the surface roughness of Mg alloys on the electrical properties and corrosion resistance of oxide layers obtained by plasma electrolytic oxidation (PEO) were studied. The leakage current in the insulating oxide layer was enhanced by increasing the surface roughness, which is a favorable characteristic for the material when applied to hand-held electronic devices. The variation of corrosion resistance with surface roughness was also investigated. The corrosion resistance was degraded by the increasing surface roughness, which was confirmed with DC polarization and impedance spectroscopy. Pitting corrosion on the passive oxide layer was also analyzed with a salt spray test, which showed that the number of pits was not affected by the surface roughness when the spray time reached 96 h.  相似文献   

6.
The plasma electrolytic oxidation (PEO) process of 6061Al alloy was carried out under the conditions with and without the assistance of ultrasound, respectively. The effects of ultrasound on the evolution of voltage, micro-discharge, morphology and composition of PEO coatings were investigated. The results show that ultrasound can greatly decrease the dielectric breakdown voltage of the coatings, increase the number of micro-discharges while decrease their average size, promote the evolution of micro-discharges, decrease the number and the average size of residual discharge pores in the coatings after 30 min of the process, promote the homogeneous distribution of elements and the formation of α-Al2O3 and 3Al2O3⋅2SiO2 in the coatings.  相似文献   

7.
Coatings with a thickness of 22-32 μm were formed on an AM60B magnesium alloy by plasma electrolytic oxidation (PEO) in electrolytes containing 12.0-24.0 g/l NaAlO2 and other additives. SEM analyses of the coated samples showed that the coatings were compact with relatively low porosity. X-ray diffraction revealed that the coatings consisted of mainly MgAl2O4 and MgO phases. The relative amount of MgAl2O4 in the coating increased with increasing NaAlO2 concentration. The relatively compact and thick coatings provide good corrosion protection for magnesium, as indicated by the results of potentiodynamic polarization tests. In addition, the PEO treatment also significantly improved the wear resistance of the alloy. Pin-on-disk wear tests showed that the PEO treatment reduced the wear volume loss by a factor of 10.  相似文献   

8.
Titania composite coatings were prepared on carbon steel by plasma electrolytic oxidation in silicate electrolyte and aluminate electrolyte with titania powers doping in the electrolytes. The microstructure of the coatings was characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). The properties of the coatings including bond strength, thickness, thermal shock resistance and corrosion resistance varying with the quantities of titania powers in the electrolytes were studied. Investigation results revealed that the coating obtained in silicate electrolyte was composed of anatase-TiO2, rutile-TiO2 crystal phases and some Fe, Si, P elements; coating obtained in aluminate electrolyte consisted of anatase-TiO2, Al2TiO5 and some Fe, P elements. Coatings obtained in two types of electrolytes show porous and rough surface. With increasing the concentration of titania powers in the electrolytes, the coating surface first became more compact and less porous and then became more porous and coarse. The bond strength and thickness were not strongly affected by concentration of titania powers in electrolytes. The valves were 23 MPa and for 66 μm for coatings obtained in aluminate electrolyte, and 21 MPa and 35 μm for coatings obtained in silicate electrolyte. Coatings obtained in silicate electrolyte showed a little better thermal shock resistance than those obtained in aluminate electrolyte and the best coatings were obtained with middle concentration of titania powers in the electrolytes. All coated samples showed better corrosion resistance than the substrate in 3.5 wt% NaCl solution. The best coatings were also obtained with middle concentration of titania powers doping in both electrolytes whose corrosion current density was decreased by 2 orders of magnitude compared with the substrate.  相似文献   

9.
The aim of this work is to discuss the growth characteristics of the ceramic coatings on Ti alloy by plasma electrolytic oxidation (PEO) technique. Ceramic coatings were prepared on Ti alloy by plasma electrolytic oxidation in different electrolyte solutions under different pulse modes. The composition and the structure of the coatings were investigated by X-ray diffraction and scanning electron microscopy (SEM), respectively. The amount of the dissolved titanium into the electrolytes during PEO process was measured by inductively coupled plasma-atomic emission spectrometer (ICP-AES). The structure and the composition of the coatings were related to the mode of the spark discharge during PEO process. (a) Under the pulsed single-polar mode: In Na3PO4 solution, the spark discharge was mainly due to the breakdown of the oxide film, and the coatings prepared were porous and mainly structured by the Ti from the substrate. In K4ZrF6-H3PO4 and NaAlO2-Na3PO4 solutions, the main mode of the spark discharge was the breakdown of the oxide film at the initial stage, and then changed into the breakdown of the vapor envelope, and the coatings were rough and thick, and mainly structured by the elements from the electrolyte. (b) Under the pulsed bi-polar mode in NaAlO2-Na3PO4 solution, the spark discharge may be mainly due to the breakdown of the oxide film, the coatings prepared were dense in inner layer and loose in outer layer, and structured by the elements from both the substrate and the electrolyte. Besides, the ICP-AES analyses showed that the amount of the dissolved titanium in the electrolyte during PEO process was more under the breakdown of the oxide film than under the breakdown of the vapor envelope, which was consistent with the changes of the structure of the coatings. Cathode pulse in the pulsed bi-polar mode increased the amount of the dissolved titanium in the electrolyte, compared with the pulsed single-polar one.  相似文献   

10.
The microstructure, composition and corrosion performance of oxide coatings formed on AM60B alloy using microarc oxidation techniques at different waveforms of applied current densities were investigated within this study. It is found that the use of optimizing current density waveforms, i.e. decaying freely current density in the later stage and stepped decreasing current density, significantly improved the microstructure of oxide coatings compared with the constant current density mode, which are connected with changes in behaviors of spark discharges on the surface in oxidation process. The optimal waveform of current density is showed to be decaying freely current density in the later stage, which results in sealing the originally formed large micropores. The optimisation of the microstructure results in a significant improvement of the corrosion resistance of oxide coating.  相似文献   

11.
Producing titania and hydroxyapatite (HA) bioceramic coating on titanium alloys increases corrosion resistance and biocompatibility of these alloys. Plasma electrolytic oxidation (PEO) is one of the effective techniques for producing this type of coating. This method produces coatings with enough thickness and appropriate adhesion. In this study, titania and HA were directly produced on Ti-6Al-4V by applying PEO process in a Ca- and P-containing electrolyte by changing voltage and time parameters. Morphology and cross section, chemical composition and elements of coatings were investigated by scanning electron microscope, X-ray diffraction and energy dispersive spectroscopy, respectively. Corrosion behavior of the samples was also examined by potentiodynamic polarization and electrochemical impedance spectroscopy. The results indicated that the formation of HA phase with titania needs a minimum voltage below which HA is not formed. By increasing the operation time, the amount of the formed HA increased. Also, the sample coated at 500 V and 15 min showed the best corrosion behavior in Ringer's solution.  相似文献   

12.
Ceramic oxide coatings (titania) were produced on Ti by micro-arc oxidation in different aluminate and carbonate based electrolytes. This process was conducted under constant pulsed DC voltage condition. The effect of KOH and NaF in aluminate based solution was also studied. The surface morphology, growth and phase composition of coatings were investigated using scanning electron microscope and X-ray diffraction. Corrosion behavior of the coatings was also examined by potentiodynamic polarization and electrochemical impedance spectroscopy. It was found that the sparking initiation voltage (spark voltage) had a significant effect on the form and properties of coatings. Coatings obtained from potassium aluminate based solution had a lower spark voltage, higher surface homogeneity and a better corrosion resistance than the carbonate based solution. Addition of NaF instead of KOH had improper effects on the homogeneity and adhesion of coatings which in turn caused a poor corrosion protection behavior of the oxide layer. AC impedance curves showed two time constants which is an indication of the coatings with an outer porous layer and an inner compact layer.  相似文献   

13.
Microarc oxidation coatings on AM60B magnesium alloy were prepared in silicate and phosphate electrolytes. Structure, composition, mechanical property, tribological, and corrosion resistant characteristics of the coatings was studied by scanning electron microscope (SEM), X-ray diffraction (XRD) and microhardness analyses, and by ball-on-disc friction and potentiodynamic corrosion testing. It is found that the coating produced from the silicate electrolyte is compact and uniform and is mainly composed of MgO and forsterite Mg2SiO4 phases, while the one formed in phosphate electrolyte is relatively porous and is mainly composed of MgO phase. The thick coating produced from a silicate electrolyte possesses a high hardness and provides a low wear rate (3.55 × 10−5 mm3/Nm) but a high friction coefficient against Si3N4 ball. A relatively low hardness and friction coefficient while a high wear rate (8.65 × 10−5 mm3/Nm) is recorded during the testing of the thick coating produced from a phosphate electrolyte. Both of these types of coatings provide effective protection for the corrosion resistance compared with the uncoated magnesium alloy. The coating prepared from the silicate electrolyte demonstrates better corrosion behavior due to the compacter microstructure.  相似文献   

14.
Plasma electrolytic oxidation (PEO) was applied on the surface of commercially pure titanium substrates in a mixed aluminate-phosphate electrolyte in the presence of silicon nitride nanoparticles as suspension in the electrolyte in order to fabricate nanocomposite coatings. Pulsed current was applied based on variable duty cycle in order to synthesize functionally gradient coatings (FGC). Different rates of variable duty cycle (3, 1.5 and 1%/min), applied current densities (0.06-0.14 A/cm2) and concentrations of nanoparticles in the electrolyte (2, 4, 6, 8 and 10 g l−1) were investigated. The nanopowder and coated samples were analyzed by atomic force microscope, scanning electron microscope and transmission electron microscope. The influence of different rates of variable duty cycle (or treatment times) on the growth rate of nanocomposite coatings and their microhardness values was investigated. The experimental results revealed that the content of Si3N4 nanoparticulates in the layer increases with the increase of its concentration in the plasma electrolysis bath. Nanocomposite coatings fabricated with lower rate of variable duty cycle have higher microhardness with smoother microhardness profile.  相似文献   

15.
The aim of this work is to discuss the growth characteristics and corrosion behavior of the prepared ceramic coatings on titanium by plasma electrolytic oxidation (PEO) technique in different electrolytes. PEO process was carried out on titanium under constant voltage regime using a pulse power supply. Three kinds of electrolytes, phosphate, silicate and borate based solutions, were used to evaluate the influence of electrolyte composition on the structure, surface morphology, phase composition and corrosion behavior of prepared ceramic oxide films (titania). The phase composition of the coatings was investigated by X-ray diffraction. Scanning electron microscopy was employed to evaluate the growth and surface morphology of coatings. Elements of coatings were investigated with energy dispersive spectrometer. Corrosion behavior of the coatings was also examined by potentiodynamic polarization and electrochemical impedance spectroscopy. The spark voltage of oxide films had a significant effect on the surface morphology, size and homogeneity of micro-pores, thickness and corrosion properties of coatings.  相似文献   

16.
Oxide coatings were produced on AM60B magnesium alloy substrate making use of microarc oxidation (MAO) technique. The effect of KF addition in the Na2SiO3-KOH electrolytic solution on the microarc oxidation process and the structure, composition, and properties of the oxide coatings was investigated. It was found that the addition of KF into the Na2SiO3-KOH electrolytic solution caused increase in the electrolyte conductivity and decrease in the work voltage and final voltage in the MAO process. Subsequently, the pore diameter and surface roughness of the microarc oxidation coating were decreased by the addition of KF, while the coating compactness was increased. At the same time, the phase compositions of the coatings also varied after the addition of KF in the electrolytic solution, owing to the participation of KF in the reaction and its incorporation into the oxide coating. Moreover, the coating formed in the electrolytic solution with KF had a higher surface hardness and better wear-resistance than that formed in the solution without KF, which was attributed to the changes in the spark discharge characteristics and the compositions and structures of the oxide coatings after the addition of KF.  相似文献   

17.
The paper reports on a systematic investigation into the effects of process parameters on the growth kinetics and associated changes in the structure, phase composition and mechanical properties of surface layers formed on Ti–6Al–4V alloy by plasma electrolytic oxidation (PEO) treatment in 0.05–0.2 mol l−1 solutions of sodium aluminate. Methods of gravimetric, SEM and XRD analysis, as well as microhardness and scratch testing, are employed to investigate mass transfer and phase-structure transformations in the surface layer. The probable mechanisms of layer formation are discussed, which comprise electrochemical oxidation of the Ti-electrode by OH anions, complimented by chemical precipitation of Al(OH)3 and plasma-induced transformations in the surface discharges. Running with a total yield efficiency of 20–30%, these processes lead to the formation of predominantly the Al2TiO5 phase with heterogeneous precipitation of Al2TiO5·TiO2 and 3Al2TiO5·Al2O3 eutectics. Al- and Ti-enriched constituents of this structure show hardnesses of 1050–1480 and 300–845 HK, 0.02, respectively. The layer growth rate increases with increasing electrolyte concentration, providing a maximum thickness of over 60 μm and a surface roughness (Ra) of 3–4 μm. Increasing the electrolyte pH from 12.0 to 12.8 results in smoothing and thickening of the surface layer but a lower sample weight gain, associated with an enhancement of the Ti electro-oxidation process. Morphological changes during PEO formation of the surface layer include gradual transformation of the original fine grained but porous structure into a dense, fused morphology which is adversely affected by discharge-induced thermal stresses, causing a degradation of the layer adhesion strength.  相似文献   

18.
Ceramic coatings were successfully prepared on steel by plasma electrolytic oxidation (PEO) in aluminate electrolyte and silicate electrolyte, respectively. The microstructure of the coatings including surface morphology, phase and element composition were studied by scanning electron microscopy (SEM) and X-ray diffraction (XRD), respectively. The bonding strength between the ceramic coating and the substrate was tested using different methods including tensile tests and shearing tests. The thermal shock resistance of the coatings was also evaluated. The results indicated that coatings obtained in both electrolytes were porous and coarse. The average diameters of the pores were below 10 μm. PEO coatings obtained in aluminate electrolyte were composed of Fe3O4 and FeAl2O4, while those obtained in silicate electrolyte were in a noncrystal state. PEO coatings obtained in aluminate electrolyte showed similar change trend of tensile strength and shearing strength with increasing treating time, namely, a relatively high values with middle time treating and low value with short and long time treating. The best coating was the samples treated with 30 min, whose tensile strength was 20.6 MPa and shearing strength was 16 MPa. The tensile strength and shearing strength of coatings obtained in silicate electrolyte were not strongly influenced by the treating time, the values of which were range in 14 ± 2 MPa and 11 ± 2 MPa, respectively. Coatings obtained in both electrolytes showed the best thermal shock resistance with middle time treating. Coatings obtained in silicate electrolyte show a little better thermal shock resistance than those obtained in aluminate electrolyte.  相似文献   

19.
Magnesium and its alloy currently are considered as the potential biodegradable implant materials, while the accelerated corrosion rate in intro environment leads to implant failure by losing the mechanical integrity before complete restoration. Dense oxide coatings formed in alkaline silicate electrolyte with and without titania sol addition were fabricated on magnesium alloy using microarc oxidation process. The microstructure, composition and degradation behavior in simulated body fluid (SBF) of the coated specimens were evaluated. It reveals that a small amount of TiO2 is introduced into the as-deposited coating mainly composed of MgO and Mg2SiO4 by the addition of titania sol into based alkaline silicate electrolytic bath. With increasing concentration of titania sol from 0 to 10 vol.%, the coating thickness decreases from 22 to 18 μm. Electrochemical tests show that the Ecorr of Mg substrate positively shifted about 300500 mV and icorr lowers more than 100 times after microarc oxidation. However, the TiO2 modified coatings formed in electrolyte containing 5 and 10 vol.% titania sol indicate an increasing worse corrosion resistance compared with that of the unmodified coating, which is possibly attributed to the increasing amorphous components caused by TiO2 involvement. The long term immersing test in SBF is consistent with the electrochemical test, with the coated Mg alloy obviously slowing down the biodegradation rate, meanwhile accompanied by the increasing damage trends in the coatings modified by 5 and 10 vol.% titania sol.  相似文献   

20.
The microstructure, morphology and composition highly determine the corrosion resistance and bioactivity of coating. In traditional cathodic electrodeposition process, because of the unfavorable effects of the polarization of concentration difference and H2 evolution, fluorine-doped hydroxyapatite coating was loose and porous. This coating could not ensure the long-term stability of the Mg alloy implants. In order to improve the corrosion resistance and bioactivity of coating, pulse electrodeposition and H2O2 were introduced into the electrodeposition to deposit fluorine-doped hydroxyapatite coating. As a comparative study, microstructure, corrosion resistance properties and bioactivity of traditional cathodic electrodeposition coating and pulse electrodeposition coating were investigated, respectively. The results revealed that nano fluorine-doped hydroxyapatite coating could be prepared by pulse electrodeposition, and the coating was dense and uniform. The potentiodynamic polarization experiment indicated that the dense and uniform coating could effectively protect Mg alloy substrate from corrosion. Immersion testing was performed in simulated body fluid. It was found that pulse electrodeposition coating could more effectively induce the precipitation of Mg2+, Ca2+ and PO43− in comparison with traditional cathodic electrodeposition coating, because the nano phase had comparatively high specific surface area. Thus magnesium alloy coated with fluorine-doped nano-hydroxyapatite coating may be a promising candidate as biodegradable bone implants, and was worthwhile to further investigate the in vivo degradation behavior.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号