首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is increasingly used as a microbial diagnostic method for species identification of pathogens. However, MALDI-TOF identification of bacteria at the species level remains unsatisfactory, with the major problem being an incomplete database that still needs refinement and expansion. Augmentation of the original MALDI BioTyper 2.0 (Bruker) database by incorporating mass spectra obtained in-house from clinical isolates may increase the identification rate at the species level. We conducted a prospective study to assess whether the augmented database can improve the performance of MALDI-TOF MS for routine identification of species. Cluster analyses revealed distinct differences in MS spectral profiles of clinical isolates obtained in our hospital and those of ATCC strains in the Bruker database. In the first part of the study, which was performed over 3 weeks, 259 bacterial isolates were subjected to analysis by MALDI-TOF MS, and MS spectra of 229 successfully identified isolates (49 species) were incorporated into the original database to give the augmented Bruker-Chiba database. In a second separate analysis, the concordance of identification of 498 clinical isolates of the 49 species with conventional methods was 87.1% (434/498) with the commercial Bruker database and 98.0% (488/498) using the Bruker-Chiba database. These results indicate that refinement of a commercial database can be achieved relatively easy and effectively by incorporating MS spectra of clinical isolates obtained in a clinical laboratory.  相似文献   

2.
The identification of new biomarkers or a disease-related protein fingerprint for inflammatory bowel diseases (IBDs) represents a major task in the diagnosis, prognosis and pharmacological therapy. To address these issues, a simple and rapid analytical proteomic method for serum protein profiling based on selective beads-based solid-phase bulk extraction, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and chemometric data analysis was developed. Serum proteins from healthy subjects (22) and patients with Crohn's disease (15) and ulcerative colitis (26) were selectively extracted according to reversed-phase (C18), strong anion-exchange (SAX) and metal ion affinity (IDA-Cu(II)) principles. This approach allowed enrichment of serum proteins/peptides due to the high interaction surface between analytes and the solid phase and high recovery due to the elution step performed directly on the MALDI-target plate. The MALDI-TOF MS serum protein profiles were acquired and, after a data pre-processing step, analyzed by linear discriminant analysis (LDA), a chemometric classification technique, in order to classify serum samples among healthy subjects and patients with inflammatory bowel diseases (IBDs). Since the high number of variables in the MALDI spectra (more than 16000 m/z values) prevents the use of LDA, the variables were reduced to 10-20 by features selection, thus allowing the evaluation of a pattern of m/z values with high discriminant power. Serum protein profiles obtained by reversed-phase extraction and the selection of 20 m/z values gave the best overall prediction ability (96.9%). The recognition of these m/z values may allow the identification of protein biomarkers involved in IBDs.  相似文献   

3.
Plant diseases caused by plant pathogens substantially reduce crop production every year, resulting in massive economic losses throughout the world. Accurate detection and identification of plant pathogens is fundamental to plant pathogen diagnostics and, thus, plant disease management. Diagnostics and disease-management strategies require techniques to enable simultaneous detection and quantification of a wide range of pathogenic and non-pathogenic microorganisms. Over the past decade, rapid development of matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) techniques for characterization of microorganisms has enabled substantially improved detection and identification of microorganisms. In the biological sciences, MALDI-TOF MS is used to analyze specific peptides or proteins directly desorbed from intact bacteria, fungal spores, nematodes, and other microorganisms. The ability to record biomarker ions, in a broad m/z range, which are unique to and representative of individual microorganisms, forms the basis of taxonomic identification of microorganisms by MALDI-TOF MS. Recent advances in mass spectrometry have initiated new research, i.e. analysis of more complex microbial communities. Such studies are just beginning but have great potential for elucidation not only of the interactions between microorganisms and their host plants but also those among different microbial taxa living in association with plants. There has been a recent effort by the mass spectrometry community to make data from large scale mass spectrometry experiments publicly available in the form of a centralized repository. Such a resource could enable the use of MALDI-TOF MS as a universal technique for detection of plant pathogens and non-pathogens. The effects of experimental conditions are sufficiently understood, reproducible spectra can be obtained from computational database search, and microorganisms can be rapidly characterized by genus, species, or strain.  相似文献   

4.
MALDI-TOF MS has proved to be an accurate, rapid, and cost-effective technique for microbial identification in which the spectral fingerprint of an unknown strain can be compared to a database of spectra from reference strains. Most of the existing databases are private and often costly to access, and little spectral information is shared among researchers. The objective of the present communication is to introduce the SpectraBank database (http://www.spectrabank.org), which provides open access MALDI-TOF mass spectra from a variety of microorganisms. This work aims to familiarize readers with the SpectraBank database, from the sample preparation, data collection, and data analysis to how the spectral reference data can be used for microbial species identification. The database currently includes more than 200 MALDI-TOF MS spectra from more than 70 bacterial species and links to the freely available web-based application SPECLUST (http://bioinfo.thep.lu.se/speclust.html) to allow comparisons of the obtained peak mass lists and evaluate phyloproteomic relationships. The SpectraBank database is intended to be expanded by the addition of new spectra from microbial strains, obtained in our laboratory and by other researchers.  相似文献   

5.
夏树华  王璋 《色谱》2007,25(1):58-65
运用反相高效液相色谱(RP-HPLC)对酶解螺蛳腹足肌得到的血管紧张素转换酶(ACE)抑制肽进行两步分离提纯,第一步主要得到8个组分;选取其中活性最高的组分进一步分离,得到2个组分,其中活性较高组分的ACE半抑制浓度为43.5 μmol/L,基本为单一肽组分。对提纯的组分分别使用高效液相色谱/电喷雾离子质谱法(HPLC/ESI-MS)和基质辅助激光解吸电离飞行时间质谱法(MALDI-TOF MS)进行分析,同时结合氨基酸组成分析结果,最终得到的肽链一级结构为Lys-Glu-Ile-Trp(KEIW),符合已知的高活性ACE抑制肽的结构规律。经过对两种方法分析过程的比较,认为ESI-MS可以得到多方面的信息,但无法确定肽的序列;MALDI-TOF MS可以得到精确的二级质谱图(m/z精确至0.0001),从而可以得到确定的肽的序列。  相似文献   

6.
用基质辅助激光解吸电离-飞行时间质谱(MALDI-TOF MS)观察炭疽芽孢适配子与炭疽芽孢结合反应,将SELEX(system evolution of ligands by exponential enrichment)技术筛选获得的一个炭疽芽孢适配子F77和第18轮的混合适配子以及兔抗炭疽芽孢抗体分别与炭疽芽孢结合反应后,用MALDI-TOF MS指纹图变化来研究这些分子与芽孢的结合情况,结果显示抗体、单体和混合适配子与芽孢结合反应后约在m/z1800处产生的质谱峰强度与芽孢对照相比明显降低;用MALDI-TOF MS质谱图变化可以推测适配子与芽孢的结合反应,该试验中观察到的结合情况与作者以前的研究结果一致。  相似文献   

7.
Atmospheric-pressure matrix-assisted laser desorption/ionization (AP-MALDI) ion trap mass spectrometry (ITMS) has been evaluated for automated protein identification. By using signal averaging and long ion-injection times, protein identification limits in the 50-fmol range are achieved for standard protein digests. Data acquisition requires 7.5 min or less per sample and the MS/MS spectra files are automatically processed using the SEQUEST database searching algorithm. AP-MALDI-ITMS was compared with the widely used methods of microLC/MS/MS (ion trap) and automated MALDI-TOF peptide mass mapping. Sample throughput is 10-fold greater using AP-MALDI compared with microcapillary liquid chromatography/tandem mass spectrometry (microLC/MS/MS). The protein sequence coverage obtained from AP-MALDI-MS/MS spectra matched by SEQUEST is lower compared with microLC/MS/MS and MALDI-TOF mass mapping. However, by using the AP-MALDI full-scan peptide mass fingerprint spectrum, sequence coverage is increased. AP-MALDI-ITMS was applied for the analysis of Coomassie blue stained gels and was found to be a useful platform for rapid protein identification.  相似文献   

8.
Chen X  Kong L  Su X  Pan C  Ye M  Zou H 《Journal of chromatography. A》2005,1089(1-2):87-100
An approach for the separation and identification of components in a traditional Chinese medicine Psoralea corylifolia was developed. Ion-exchange chromatography (IEC) was applied for the fractionation of P. corylifolia extract, and then followed by concentration of all the fractions with rotary vacuum evaporator. Each of the enriched fractions was then further separated on an ODS column with detection of UV absorbance and atmospheric pressure chemical ionization mass spectrometer (APCI/MS), respectively, and also analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) with matrix of oxidized carbon nanotubes. Totally more than 188 components in P. corylifolia extract were detected with this integrated approach, and 12 of them were preliminary identified according to their UV spectra and mass spectra performed by APCI/MS and MALDI-TOF/MS. The obtained analytical results not only demonstrated the powerful resolution of integration IEC fractionation with reversed-phase liquid chromatography (RPLC)-APCI/MS and MALDI-TOF/MS for analysis of compounds in a complex sample, but also exhibited the superiority of APCI/MS and MALDI-TOF/MS for identification of low-mass compounds, such as for study of traditional Chinese medicines (TCMs) and metabolome.  相似文献   

9.
Careful analysis of the electron impact (EI) mass spectral data obtained for the trimethylsilyl (TMS) ethers of known trichothecene mycotoxins of the deoxynivalenol group permitted the construction of a database useful for the identification of these mycotoxins directly from a gas chromatography/mass spectrometry (GC/MS) run. Structures of the ions at m/z 103, 117, 147 and 191 were elucidated by high-resolution mass spectrometry (HRMS) and a fragmentation scheme was suggested. The relative abundances of these ions in the mass spectra of the trichothecenes allowed a fast structural diagnosis during analysis of biological matrices. A new mycotoxin of this group, 3-acetylnivalenol, was tentatively identified by using MS data interpretation only.  相似文献   

10.
An organic salt, N-(1-naphthyl) ethylenediamine dinitrate (NEDN), with rationally designed properties of a strong UV absorbing chromophore, hydrogen binding and nitrate anion donors, has been employed as a matrix to analyze small molecules (m/z?相似文献   

11.
Acceleration of liquid chromatography/mass spectrometric (LC/MS) analysis for metabolite identification critically relies on effective data processing since the rate of data acquisition is much faster than the rate of data mining. The rapid and accurate identification of metabolite peaks from complex LC/MS data is a key component to speeding up the process. Current approaches routinely use selected ion chromatograms that can suffer severely from matrix effects. This paper describes a new method to automatically extract and filter metabolite-related information from LC/MS data obtained at unit mass resolution in the presence of complex biological matrices. This approach is illustrated by LC/MS analysis of the metabolites of verapamil from a rat microsome incubation spiked with biological matrix (bile). MS data were acquired in profile mode on a unit mass resolution triple-quadrupole instrument, externally calibrated using a unique procedure that corrects for both mass axis and mass spectral peak shape to facilitate metabolite identification with high mass accuracy. Through the double-filtering effects of accurate mass and isotope profile, conventional extracted ion chromatograms corresponding to the parent drug (verapamil at m/z 455), demethylated verapamil (m/z 441), and dealkylated verapamil (m/z 291), that contained substantial false-positive peaks, were simplified into chromatograms that are substantially free from matrix interferences. These filtered chromatograms approach what would have been obtained by using a radioactivity detector to detect radio-labeled metabolites of interest.  相似文献   

12.
We report herein, facile metabolite identification workflow on the anti-depressant nefazodone, which is derived from accurate mass measurements based on a single run/experimental analysis. A hybrid LTQ/orbitrap mass spectrometer was used to obtain accurate mass full scan MS and MS/MS in a data-dependent fashion to eliminate the reliance on a parent mass list. Initial screening utilized a high mass tolerance ( approximately 10 ppm) to filter the full scan MS data for previously reported nefazodone metabolites. The tight mass tolerance reduces or eliminates background chemical noise, dramatically increasing sensitivity for confirming or eliminating the presence of metabolites as well as isobaric forms. The full scan accurate mass analysis of suspected metabolites can be confirmed or refuted using three primary tools: (1) predictive chemical formula and corresponding mass error analysis, (2) rings-plus-double bonds, and (3) accurate mass product ion spectra of parent and suspected metabolites. Accurate mass characterization of the parent ion structure provided the basis for assessing structural assignment for metabolites. Metabolites were also characterized using parent product ion m/z values to filter all tandem mass spectra for identification of precursor ions yielding similar product ions. Identified metabolite parent masses were subjected to chemical formula calculator based on accurate mass as well as bond saturation. Further analysis of potential nefazodone metabolites was executed using accurate mass product ion spectra. Reported mass measurement errors for all full scan MS and MS/MS spectra was <3 ppm, regardless of relative ion abundance, which enabled the use of predictive software in determining product ion structure. The ability to conduct biotransformation profiling via tandem mass spectrometry coupled with accurate mass measurements, all in a single experimental run, is clearly one of the most attractive features of this methodology.  相似文献   

13.
The formation of linoleic acid radical species under the oxidative conditions of the Fenton reaction (using hydrogen peroxide and Fe (II)) was monitored by FAB-MS and ES-MS using the spin trap 5,5-dimethyl-1-pyrrolidine-N-oxide, DMPO. Both the FAB and ES mass spectra were very similar and showed the presence of ions corresponding to carbon- and oxygen centered spin adducts (DMPO/L*, DMPO/LO*, and DMPO/LOO*). Cyclic structures, formed between the DMPO oxygen and the neighboring carbon of the fatty acid, were also observed. Electrospray tandem mass spectrometry of these ions was performed to confirm the proposed structure of these adducts. All MS/MS spectra showed an ion at m/z 114, correspondent to the [DMPO + H]+, and a fragment ion due to loss of DMPO (loss of 113 Da), confirming that they are DMPO adducts. ES-MS/MS spectra of alkoxyl radical adducts (DMPO/LO*) showed an additional ion at m/z 130 [DMPO - O + H]+, while ES MS/MS of peroxyl radical adducts (DMPO/LOO*) showed a fragment ion at m/z 146 [DMPO - OO + H]+, confirming both structures. Other fragment ions were observed, such as alkyl acylium radical ions, formed by cleavage of the alkyl chain after loss of water and the DMPO molecule. The identification of fragment ions observed in the MS/MS spectra of the different DMPO adducts suggests the occurrence of structural isomers containing the DMPO moiety both at C9 and C13. The use of ES tandem mass spectrometry, associated with spin trapping experiments, has been shown to be a valuable tool for the structural characterization of carbon and oxygen-centered spin adducts of lipid radicals.  相似文献   

14.
The development of analytical techniques suitable for providing structural information on a wide range of elemental species is a growing necessity. For arsenic speciation a variety of mass spectrometric techniques, mainly inductively coupled plasma mass spectrometry (ICP-MS) and electrospray tandem mass spectrometry (ES-MS/MS) coupled on-line with high-performance liquid chromatography (HPLC), are in use. In this paper we report the identification of arsenic species present in samples of marine origin (seaweed extracts) using ES ion trap mass spectrometry (IT) multistage mass spectrometry (MS(n)). Both reversed-phase and anion-exchange HPLC have been coupled on-line to ES-ITMS. Product ion scans with multiple stages of tandem MS (MS(n); n=2-4) were used to acquire diagnostic data for each arsenosugar. The spectra contain structurally characteristic fragment ions for each of the arsenosugars examined. In addition it was observed that upon successive stages of collision-induced dissociation (CID) a common product ion (m/z 237) was formed from all four arsenosugars examined. This product ion has the potential to be used as an indicator for the presence of dimethylated arsenosugars (dimethylarsinoylribosides). The HPLC/ES-ITMS(n) method developed allows the sensitive identification of arsenosugars present in crude seaweed extracts without the need for extended sample preparation. In fact, sample preparation requirements are identical to those typically employed for HPLC/ICP-MS analysis. Additionally, the resulting product ions are structurally diagnostic of the arsenosugars examined, and tandem mass spectra are reproducible and correspond well to those obtained using other low-energy CID techniques. As a result, the HPLC/ES-ITMS(n) approach minimises the potential for arsenic species misidentification and has great potential as a means of overcoming the need for characterised standards.  相似文献   

15.
We demonstrate that the semi-quantitative information in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectra of tryptically digested protein mixtures can, via a systematic statistical approach, be utilized for the identification of a protein present in different concentrations in two samples. Multiple mass spectra were acquired from a series of tryptically digested test samples in which the concentration of one protein was varied and the concentrations of three other proteins were held constant. The mass spectra were subjected to soft independent modeling of class analogy (SIMCA) analysis assuming that spectra originating from two different samples belonged to different data classes. The SIMCA analysis yielded information on which individual m/z values discriminate between two classes. Protein identification by proteolytic peptide mass fingerprinting was performed with different numbers of mass values in the fingerprint according to the discriminatory information, beginning with the mass corresponding to the best discrimination, followed by the best together with the second best, etc. By using the Probity algorithm, which computes the statistical significance of each identification result, we demonstrate that the first protein identified at a desired significance level (0.001) is the protein that was present in a different concentration in the two samples. Differential analysis of expression is often performed by comparing 2D-gel-spot intensities followed by mass spectrometric identification of the respective protein in each spot that differs. The method presented here has the potential to allow identification of the protein component that differs in cases where a gel-spot is poorly resolved and contains several proteins.  相似文献   

16.
Analysis of crude methanolic extracts of fresh khat (Catha edulis) by liquid chromatography/mass spectrometry (LC/MS) revealed the presence of 62 cathedulin alkaloids (compared with 15 published structures). Many cathedulins generated doubly protonated molecules following electrospray ionisation and the ratio of doubly to singly protonated species could be manipulated by adjusting the electrospray capillary position and source conditions. By selecting the doubly protonated species for serial mass spectrometric analysis (MS/MS), it was possible to use an ion trap mass spectrometer to observe singly charged product ions at lower m/z values than ion trap MS/MS analysis of [M+H](+) would have allowed. These spectra were particularly valuable in elucidating the acylation patterns of cathedulins where MS/MS analysis of [M+H](+) resulted in loss of a large neutral species to yield a small singly charged fragment below the lower limit for ion trapping. Acylation patterns for most of the 62 cathedulins are proposed from mass spectrometric analysis, and the data obtained for a major unreported cathedulin of mass 1001 Da suggest that it belongs to a new group of cathedulins having a cathate dilactone bridge but not an evoninate bridge.  相似文献   

17.
Characterization of the peptide content in snake venoms can be an important tool for the investigation of new pharmacological lead compounds. For this purpose, single-step analysis of crude venoms has recently been demonstrated using mass spectrometry (MS) techniques. Reproducible profiles of ions in MS and MS/MS spectra may also be used to compare venoms from different species. In this work matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was used to obtain mass patterns of the major peptides (<8 kDa) found in pooled venoms from the genera Bothrops and Crotalus. Venoms from five different Bothrops species (B. jararaca, B. insularis, B. alternatus, B. jararacussu, and B. neuwiedi) and three Crotalus species (C. viridis, C. adamanteus and C. durissus terrificus) were analyzed. In agreement with other reports, venoms from Bothrops species contained a variety of peptides in the range m/z 1000-1500, and in some samples larger components (m/z 7000-8000) were detected. In the Crotalus species venoms were rich in peptides ranging from m/z 1000-1500 and 4000-5500. MS/MS experiments on the low molecular mass peptides (m/z 1000-1500) confirmed the presence of ten new bradykinin-potentiating peptides among venoms from genera Bothrops and Crotalus. In order to determine whether additional peptides could be identified after partial purification, B. jararaca venom was subjected to size-exclusion chromatography on Sephacryl S-200, and two distinct low molecular mass pools were analyzed further by MALDI-TOFMS. No additional peptides were detected from the pool with masses below 2000 Da but a substantial improvement with better resolution was observed for the pool with masses above 7000 Da, indicating that complex samples such as crude snake venoms can be analyzed for low molecular mass peptides using a single-step procedure.  相似文献   

18.
An important aspect in drug discovery is the early structural identification of the metabolites of potential new drugs. This gives information on the metabolically labile points in the molecules under investigation, suggesting structural modifications to improve their metabolic stability, and allowing an early safety assessment via the identification of metabolic activation products. From an analytical point of view, metabolite identification still remains a challenging task, especially for in vivo samples, in which they occur at trace levels together with high amounts of endogenous compounds. Here we describe a method, based on LC-ion trap tandem MS, for the rapid in vivo metabolite identification. It is based on the automatic, data-dependent acquisition of multiple product ion MS/MS scans, followed by a postacquisition search, within the entire MS/MS data set obtained, for specific neutral losses or marker ions in the tandem mass spectra of parent molecule and putative metabolites. One advantage of the method is speed, since it requires minimum sample preparation and all the necessary data can be obtained in one chromatographic run. In addition, it is highly sensitive and selective, allowing detection of trace metabolites even in the presence of a complex matrix. As an example of application, we present the studies of the in vivo metabolism of the compound MEN 15916 (1). The method allowed identification of monohydroxy ([M + H](+) = m/z 655), dihydroxy ([M + H](+) = m/z 671), and trihydroxy ([M + H](+) = m/z 687) metabolites, as well as some unexpected biotransformation products such as a carboxylic acid ([M + H](+) = m/z 669), a N-dealkylated metabolite ([M + H](+) = m/z 541), and its hydroxy-analog ([M + H](+) = m/z 557).  相似文献   

19.
Anatoxin-a (AN) and homoanatoxin-a (HMAN) are potent neurotoxins produced by a number of cyanobacterial species. A new, sensitive liquid chromatography/multiple tandem mass spectrometry (LC/MS(n)) method has been developed for the determination of these neurotoxins. The LC system was coupled, via an electrospray ionisation (ESI) source, to an ion-trap mass spectrometer in positive ion mode. The [M+H](+) ions at m/z 166 (anatoxin-a) and m/z 180 (homoanatoxin-a) were used as the precursor ions for multiple MS experiments. MS(2)bond;MS(4) spectra displayed major fragment ions at m/z 149 (AN), 163 (HMAN), assigned to [Mbond;NH(3)+H](+); m/z 131 (AN), 145 (HMAN), assigned to [Mbond;NH(3)bond;H(2)O+H](+), and m/z 91 [C(7)H(7)](+). Although the chromatographic separation of these neurotoxins is problematic, reversed-phase LC, using a C(18) Luna column, proved successful. Calibration data for anatoxin-a using spiked water samples (10 mL) in LC/MS(n) modes were: LC/MS (25-1000 microg/L), r(2) = 0.998; LC/MS(2) (5-1000(microg/L), r(2) = 0.9993; LC/MS(3) (2.5-1000 microg/L), r(2) = 0.9997. Reproducibility data (% RSD, N = 3) for each LC/MS(n) mode ranged between 2.0 at 500 microg/L and 7.0 at 10 microg/L. The detection limit (S/N = 3) for AN was better than 0.03 ng (on-column) for LC/MS(3) which corresponded to 0.6 microg/L.  相似文献   

20.
Mass spectra of atactic polystyrene were collected into the mega-dalton mass range with a matrix-assisted laser desorption ionization time of flight (MALDI TOF) mass spectrometer, which incorporates a cryodetector comprised of an array of 16 superconducting tunnel junctions (STJ). The STJ cryodetector, theoretically, has no loss in signal response at any mass compared with the reduced signal found at high mass when using a conventional secondary-ionization detector. Since ion detection at high m/z is one of the fundamental limitations of mass spectrometry (MS), the cryodetector was used to explore the high m/z limit of the MALDI TOF technique for the analysis of two polymer types. Mass spectra were collected for polystyrene at Mn 170, 400, 900, and 2000 kDa and polymethyl methacrylate (PMMA) at Mn 62.6 kDa and 153.7 kDa. For polystyrene, the data showed a trend toward increased aggregation and charge state with mass. The Mn 2 MDa polystyrene data revealed a peak at m/z 2.2 MegaTh and a charge state analysis revealed that these ions were primarily polystyrene aggregates with a mass of approximately 4 MDa. This aggregate assignment was possible because the cryodetector response allows for the determination of a charge state up to about four. The contribution of each charge state for a selected peak can be determined in this fashion. This analysis revealed the preferential formation of doubly charged even-numbered aggregates over odd-numbered aggregates for high molecular mass polystyrene. A potential mechanism for the aggregation process for doubly charged species is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号