首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Polyhalogenated aromatic hydrocarbons, such as polychlorinated dibenzo-p-dioxins are a large and diverse group of environmental pollutants. Their tendency to accumulate in the food chain and their toxicity make monitoring necessary. The reference analysis method is laborious and very expensive, therefore cheap and rapid bioassays have been developed. The chemical-activated luciferase bioassay (CALUX) bioassay uses a recombinant cell line, which responds to dioxins and dioxin-like molecules with Ah receptor (AhR)-dependent induction of firefly luciferase in a dose related response. The CALUX was tested for its use in the screening of feed. Aliquots of 20 g of enriched feed were extracted with a toluene:methanol mixture (20:4 v/v) and extracts were defatted on 33% H2SO4 silica columns and purified on carbon columns. Only the dioxin and furan fraction was analysed, the PCB fraction was discarded. The precision of the method is acceptable and in compliance with an R.S.D. <30% as suggested for cell-based bioassays in the Commission Directive 2002/70/EC of July 2002. The results evidence good agreement between TEQ-values obtained by either CALUX or GC–HRMS. The method is now routinely in use for a feed screening programme designed by the Federal Agency for the Safety of the Food chain. Approximately, 25 samples are analysed weekly. From the obtained results approximately 10% was confirmed by GC–HRMS. The false positive ratio is 1% and no false negatives were found, making the use of the CALUX technology advantageous.  相似文献   

2.
Differences between chemical activated luciferase gene expression (CALUX) bioassay and chemoanalyses results are observed.

This paper shows that calculations of the TEQ values using REP values instead of WHO TEF values give different results. The REP values do affect the results obtained by the CALUX technique. These differences are more marked for the dioxin like PCB compounds (CALUX TEQ values are lower than WHO TEQ values) than for the dioxin compounds (CALUX TEQ values are higher than WHO TEQ values).

The CALUX results were compared with the concentrations of the congeners’ spiked into the oil.  相似文献   


3.
Schroijen C  Windal I  Goeyens L  Baeyens W 《Talanta》2004,63(5):1261-1268
The reporter gene expression method CALUX has proven to be a very valuable screening technique for assessing toxic equivalents of dioxins and dioxin-like compounds, because it detects all AhR ligands in a variety of sample matrices. However, the exact meaning of the CALUX response is difficult to evaluate for complex mixtures mainly since not all AhR ligands are known and since antagonistic or synergistic effects occurs.

In this paper, non-additive effects on the CALUX response of dioxins were investigated for a limited number of dioxin-like compounds in concentration ranges that are 102–108 times higher than that of 2,3,7,8-TCDD. Antagonistic effects are detected for three Aroclors (1242, 1254, 1260), Halowax 1014 (PCN), HCB and PBB 169. The ratios, Aroclor/dioxin, Halowax/dioxin and HCB/dioxin, needed to observe an antagonistic effect are 10 000, 5000 and 50 000, respectively. No significant deviation from additivity was observed for Aroclor 5442 (PCT) and PBB 77 in the concentration range investigated.

Two clean-up procedures have also been tested: in some cases the non-additive effects disappeared or were strongly reduced. Using only an acidic silica column, the classical dioxin-like compounds investigated here (PCB, PCT, PBB, PCN, HCB) as well as the dioxins are collected and analyzed altogether in one fraction. Consequently, no major alteration of the non-additive effects is expected. An acidic silica column combined with an activated carbon column allows the separation of PCDD/F and dioxin-like PCB in two different fractions, PBB 169 is completely eluted in the dioxin fraction and PBB 77 is distributed between the PCB and dioxin fraction. HCB is completely separated from the PCDD/F fraction.  相似文献   


4.
Analyses of dioxins in food have become increasingly important since the European Commission has enforced maximal toxic equivalent concentration (TEQ) levels in various food and feed products. Screening methodologies are usually used to exempt those samples that are below the maximum permitted limit and that can, therefore, be released to the market. In addition, one needs to select those samples that require confirmation of their dioxin TEQ level. When bioassays are used as screening tools, the interpretation of the obtained results should consider the higher variability and uncertainty associated with them. This paper explores the use of CALUX data as quantitative screening results. The validation of the method for the polychlorinated dibenzo-p-dioxins (PCDD)/F TEQ determination in milk samples is described with emphasis on the decision limit (CC) and the precision of the method. The decision limit amounts to 4.53 pg TEQ/g fat. Repeatability and within-lab reproducibility coefficients of variation are below 30%. The newly introduced parameter CC* of 1.47 pg TEQ/g fat delimits with CC a range of suspicious results. These data are not significantly different from the maximum limit of 3 pg TEQ/g fat and should be confirmed by a confirmatory analytical method such as HRGC–HRMS.  相似文献   

5.
杜兵  刘爱民  黄业茹 《色谱》2014,32(9):967-970
采用同位素稀释高分辨气相色谱-高分辨质谱法(isotope dilution high resolution gas chromatography and high resolution mass spectrometry,ID-HRGC-HRMS)测定土壤样品中二恶英类化合物(polychlorinated dibenzo-p-dioxins and dibenzofurans,PCDD/Fs)的等价毒性当量(toxic equivalent quantity,TEQ)。讨论并确定了测定土壤样品中二恶英类化合物2,3,7,8位异构体不确定度的来源并合成了各异构体的相对标准不确定度;在此基础上,计算了3种等价毒性当量因子(toxic equivalent factor,TEF)框架下土壤样品中PCDD/Fs的TEQ浓度及其合成不确定度和扩展不确定度。  相似文献   

6.
This paper reports on the optimisation, characterisation, validation and applicability of gas chromatography coupled to triple quadrupole mass spectrometry in its tandem operation mode (GC-QqQ(MS/MS) for the quantification of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs, dioxins) and dioxin-like polychlorinated biphenyls (DL-PCBs) in environmental and food matrices. MS/MS parameters were selected to achieve the high sensitivity and selectivity required for the analysis of this type of compounds and samples. Good repeatability for areas (RSD = 1–10%, for PCDD/Fs and DL-PCBs) and for ion transition ratios (RSD = 0.3–10%, for PCDD/Fs, and 0.2–15%, for DL-PCBs) and low instrumental limits of detection, 0.07–0.75 pg μL−1 (for dioxins) and 0.05–0.63 pg μL−1 (for DL-PCBs), were obtained. A comparative study of the congener specific determination using both GC-QqQ(MS/MS) and gas chromatography-high resolution mass spectrometry (GC-HRMS) was also performed by analysing several fortified samples and certified reference materials (CRMs) with low (feed and foodstuffs), median (sewage sludge) and high (fly ash) toxic equivalency (TEQ) concentration levels, i.e. 0.60, 1.83, 72.9 and 3609 pg WHO-TEQ(PCDD/Fs) g−1. The agreement between the results obtained for the total TEQs (dioxins) on GC-QqQ(MS/MS) and GC-HRMS in all the investigated samples were within the range of ±4%, and that of DL-PCBs at concentration levels of 0.84 pg WHO-TEQs (DL-PCBs) g−1, in the case of feedstuffs, was 0.11%. Both instrumental methods have similar and comparable linearity, precision and accuracy. The GC-QqQ(MS/MS) sensitivity, lower than that of GC-HRMS, is good enough (iLODs in the down to low pg levels) to detect the normal concentrations of these compounds in food and environmental samples. These results make GC-QqQ(MS/MS) suitable for the quantitative analysis of dioxins and DL-PCBs and a real alternative tool to the reference sector HRMS instruments.  相似文献   

7.
Immunochemical determination of dioxins in sediment and serum samples   总被引:3,自引:0,他引:3  
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are considered highly toxic contaminants and the environmental and biological monitoring of these compounds is of great concern. Immunoassays may be used as screening methods to satisfy the growing demand for rapid and low cost analysis. In this work, we describe the application of an immunoassay that uses 2,3,7-trichloro-8-methyldibenzo-p-dioxin (TMDD) as a surrogate standard for 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) to sediment and human serum samples. Sample extraction and preparation methods were developed with the aim to establish the simplest, cost-effective and efficient removal of the matrix interferences in the enzyme-linked immunosorbent assay (ELISA). The overall method for sediments is based on a hexane extraction; clean up by a multilayered silica gel column and an activated carbon column; an organic solvent exchange with DMSO–Triton X-100 and ELISA measurement. The gas chromatography–high resolution mass spectrometry (GC–HRMS) validation studies (n = 13) revealed that the method is suitable for the toxic equivalents (TEQ) screening of dioxin in sediments with a method detection limit of about 100 pg g−1 dry sediment with a precision of 13–33% R.S.D. The analysis of a large number of samples originating from different sources would be required to establish more precisely the screening level, as well as the number of false positives and negatives of dioxin TEQ by the immunoassay for sediments. The immunoassay method for sediment analysis offers improvement in speed, sample throughput, and cost in comparison to GC–HRMS. Dioxins were determined in serum samples after a simple liquid–liquid extraction and solvent exchange into DMSO–Triton X-100 without further dilution. The current method (approximate method LOQ of 200 pg ml−1 serum) is not sufficiently sensitive for the determination of dioxins in serum to measure acceptable exposure limit.  相似文献   

8.
2014年1月在杭州市选择5个点位采集大气颗粒物PM2.5样品,采用同位素稀释高分辨气相色谱/高分辨质谱测定PM2.5中的二恶英(PCDD/Fs)和多氯联苯(PCBs),对PM2.5的污染状况以及PM2.5中PCDD/Fs和PCBs的污染水平及分布特征进行了研究。PM2.5的质量浓度范围为85~168 μg/m3,PM2.5污染较重,但与2004年同期相比明显降低。PM2.5中PCDD/Fs的毒性当量(TEQ)为0.277~0.488 pg I-TEQ/m3,明显高于2004年同期采集样品。颗粒物中PCDD/Fs以八氯代二苯并-对-二恶英(OCDD)为主,毒性当量主要贡献者为2,3,4,7,8-五氯代二苯并呋喃(2,3,4,7,8-PeCDF)。PM2.5中PCBs的质量浓度范围为2.9~8.1 pg/m3,二恶英类多氯联苯(DL-PCBs)的毒性当量范围为2.6~6.1 fg WHO-TEQ/m3,污染较低。PCBs在颗粒物中分布以PCB-28为主,但对毒性当量贡献最大的为PCB-126。PCDD/Fs和PCBs的气-固分配特征表现为PCDD/Fs主要分布于颗粒物中,而PCBs主要分布于气相中。  相似文献   

9.
Differences between chemical activated luciferase gene expression (CALUX) bioassay and chemoanalyses results are observed.This paper shows that calculations of the TEQ values using REP values instead of WHO TEF values give different results. The REP values do affect the results obtained by the CALUX technique. These differences are more marked for the dioxin like PCB compounds (CALUX TEQ values are lower than WHO TEQ values) than for the dioxin compounds (CALUX TEQ values are higher than WHO TEQ values).The CALUX results were compared with the concentrations of the congeners’ spiked into the oil.  相似文献   

10.
A method was developed on a gas chromatograph coupled to a triple quadrupole mass spectrometer(GC-MS/MS) for trace level determination of polychlorinated dibenzo-p-dioxins/dibenzofurans(PCDD/Fs) and dioxin-like polychlorinated biphenyls(DL-PCBs) in food and feed. The results demonstrated good sensitivity and repeatability for PCDD/Fs and DL-PCBs at an extremely low level(10 pg mL~(-1) for 2,3,7,8-TCDD/F), as well as wide linear response of over 3 or 4 orders of magnitude in concentration ranges; 0.5–200 ng mL~(-1) for PeCDD/F and 0.2–2000 ng mL~(-1) for DL-PCBs. The method detection limits for PCDD/Fs and DL-PCBs were in the range from 0.018–0.17 pg g~(-1) to 0.13–0.36 pg g~(-1), respectively. The performance of the GC-MS/MS for food and feed sample analysis showed high precision and accuracy compared to the high resolution gas chromatograph/high resolution mass spectrometer. The results indicated the feasibility of GC-MS/MS as a confirmatory method for the measurement of PCDD/Fs and DL-PCBs in food and feed as required by European Union legislation.  相似文献   

11.
The chemical-activated luciferase expression (CALUX) assay is a reporter gene assay that detects dioxin-like compounds based on their ability to activate the aryl hydrocarbon receptor (AhR) and thus expression of the reporter gene. In this paper, the CALUX assay was examined for its application in the screening of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dioxin-like PCBs) in retail fish. The sample extracts were cleaned up on a sulfuric acid-silica gel column followed by an activated carbon column, and the AhR activity of the separated PCDD/F and dioxin-like PCB fractions was determined using the assay. The quantitative limit for 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) was 0.98 pg ml(-1) (0.19 pg assay(-1) in the standard curve, corresponding to 0.16 pg g(-1) of CALUX-based toxic equivalency (2,3,7,8-TCDD equivalents) in the tested sample. Recovery tests in which dioxins were added to fish samples resulted in acceptable recoveries (77-117%). The CALUX assay performed well in the analysis of dioxins in fish samples and a comparative study revealed a strong correlation between the CALUX assay and high-resolution gas chromatography-high-resolution mass spectrometry analysis for the determination of PCDD/Fs (r = 0.89) and dioxin-like PCBs (r = 0.91) in retail fish (n = 22). These data revealed that the CALUX assay would be a useful screening method for PCDD/Fs and dioxin-like PCBs in retail fish.  相似文献   

12.
This paper presents Chemically Activated LUciferine gene eXpression (CALUX) TEQ-values obtained for nine plasma samples following two different purification procedures, one of them involving fractionation. CALUX results obtained for the dioxin (DX) and dioxin + PCB (DX + PCB) fractions were then compared to the GC-HRMS TEQ-values calculated for the 17 polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (17 PCDD/F) and 17 PCDD/F + 4 cPCB congeners, respectively. The overestimation of the CALUX (DX fraction) TEQ-values in comparison with the chemo-analyses of the 17 PCDD/F is mainly explained by the presence of other AhR agonists, like brominated compounds. Otherwise, the constancy of the CALUX (DX + PCB fraction) TEQ-value which compares to increasing the GC-HRMS (17 PCDD/F + 4 cPCB) TEQ results raises questions concerning (1) the significance of CALUX results obtained without fractionation as well as (2) the toxicological effect of a cocktail of contaminants on the human health.  相似文献   

13.
The European strategy for dioxin monitoring of the food chain has defined high-resolution gas chromatography coupled to high-resolution mass spectrometry (HRGC/HRMS) method as the confirmatory method that can provide reliable and comparable results at sub-parts per trillion (ppt) level. This paper describes the first inter-laboratory study on dioxins, furans and dioxin-like PCBs by HRGC/HRMS method in animal feedingstuffs. Two different statistical approaches (ISO 5725 and Cofino’s statistics) were used for the statistical evaluation. For this particular study, the performances of the HRGC/HRMS method seem to be congener-independent in repeatability and reproducibility conditions over a concentration range covering more than four orders of magnitude. Results clearly show the effect of precision loss below 0.1 ppt level per congener in repeatability conditions and below 0.2 ppt level per congener in reproducibility conditions. LODs reported by the laboratories give median values of 0.02 ng/kg for most of the toxic congeners. Relative standard deviation between the laboratories’ mean values using upper-bound approach for TEQ calculation is 6.2%, more than twice the maximum level set at 0.75 ng TEQ/kg of product.  相似文献   

14.
Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast and inexpensive tool for the throughput analysis of dioxin-like compounds in a large number of samples and requires only small sample volumes, the use of this technique in human biomonitoring programs provides a good alternative to GC-HRMS. In this study, a method for the separate analysis of PCDD/Fs and dioxin-like PCBs (dl-PCBs) in human serum with the new sensitive H1L7.5c1 mouse hepatoma cell line was optimized.Sample dilution factors of 5 and 2.4 were selected for routine analysis of respectively the PCDD/Fs and dl-PCBs. The validation studies showed that repeatability and within-lab reproducibility for the quality control (QC) standard were within the in-house criteria. A long-term within-lab reproducibility of 25% for the PCDD/F fraction and 41% for the dl-PCB fraction for the analysis of pooled serum samples, expressed as pg BEQ/g fat, was determined. CALUX recoveries of the spiked procedural blanks were within the acceptable in-house limits of 80-120% for both fractions and the LOQ was 30.3 pg BEQ/g fat for the PCDD/Fs and 14.5 pg BEQ/g fat for the dl-PCBs. The GC-HRMS recovery of a C13-spiked pooled serum sample was between 60 and 90% for all PCDD/F congeners and between 67 and 82% for the non-ortho PCBs. An adequate separation between both fractions was found. The CALUX/GC-HRMS ratio for a pooled serum sample was respectively 2.0 and 1.4 for the PCDD/Fs and the dl-PCBs, indicating the presence of additional AhR active compounds. As expected, a correlation was found between human serum samples analyzed with both the new H1L7.5c1 cell line and the more established H1L6.1c3 cell line. The geometric mean CALUX-BEQ values, reported for the adolescents of the second Flemish Environment and Health Study (FLEHS II) recruited in 2009-2010, were 108 (95% CI: 101-114) pg CALUX-BEQ/g fat for the PCDD/Fs and 32.1 (30.1-34.2) pg CALUX-BEQ/g fat for the dioxin-like PCBs.  相似文献   

15.
《Analytica chimica acta》2004,520(1-2):237-243
In the Czech Republic no study on the levels of brominated flame retardants in human milk has been conducted, yet. In the first step analytical method for determination of PBDEs in this bioindicator matrix was implemented. Liquid–liquid extraction (LLE) (hexane, diethyl ether), followed by gel permeation chromatography was employed for isolation of PBDEs. Identification and quantification of PBDEs was carried out by GC–MS operated in negative chemical ionisation (NCI). Two mass spectrometric technologies, one employing quadrupole and the other one high resolution (HR) time-of-flight (TOF) analyzer, etc. were used in our study. Detection limits (LODs) obtained by quadrupole analyzer ranged from 0.02 to 0.05 ng g−1 lipid weight, using high resolution time-of-flight analyzer LODs were significantly lower, ranging from 0.002–0.005 ng g−1 lipid weight, what enabled detection of minor PBDE congeners.

Within this pilot study 103 breast milk samples, obtained from mothers living in Olomouc region, were examined. Ten PBDE congeners were determined. All samples examined till now contained PBDEs residues, the dominating contaminant representing this group was congener BDE 47. In most of analysed samples levels of this compound ranged from 0.2 to 2 ng g−1 of lipid weight. Three exceptionally contaminated samples, containing levels of PBDEs 5–10 times higher than other samples, were found.  相似文献   


16.
Inductively coupled plasma mass spectrometry (ICP-MS) and atomic fluorescence spectrometry (AFS) coupled with gas chromatography (GC) have been evaluated as element specific detectors for the determination of methylmercury in marine samples. Detection limits for methylmercury chloride, obtained using ICP-MS and AFS, were 0.9 and 0.25 pg as Hg, respectively. Methylmercury was determined in marine tissue reference materials IAEA 142 and NIST 8044 mussel homogenate, and DOLT-2 dogfish liver by GC–AFS, with found values of 45±7, 26±4, and 671±41 ng g−1, compared with certified values of 47±4, 28±2, and 693±53 ng g−1. The analyses of IAEA 142 and NIST 8044 were repeated using GC–ICP-MS, with found values of 48±9 and 30±3 ng g−1, respectively. Methylmercury was determined in real samples of ringed seal and beluga whale, with found values of 801±62 and 2830±113 ng g−1, respectively.  相似文献   

17.
随机选择空白的和经过印刷的新闻纸和复印纸,粉碎后用溶剂提取并经多步色谱柱纯化,采用同位素稀释、高分辨气相色谱/高分辨质谱(HRGC/HRMS)联用技术分析了其中的二含量。结果表明:新闻纸中二的总量高于复印纸,但是毒性当量却低于复印纸;经过印刷的新闻纸和复印纸中二的含量均高于空白的新闻纸和复印纸;新闻纸和复印纸中相同二异构体的含量 是不同的。空白的和经过印刷的新闻纸中二毒性当量分别为0.48 ng/kg和0.61 ng/kg,而空白的和经过印刷的复印纸中二恶英毒性当量分别为0.74 ng/kg和0.79  相似文献   

18.
Eppe G  Focant JF  Pirard C  Pauw ED 《Talanta》2004,63(5):1135-1146
Recent developments in trapping efficiency inside ion trap mass spectrometer permitted to lower instrument detection limit (IDL). An IDL of 200 fg μl−1 injected with a signal-to-noise ratio of 5:1 for tetrachlorodibenzo-p-dioxin (TCDD) was obtained by gas chromatography coupled to a quadrupole ion storage mass spectrometer in tandem mode (GC/MS/MS). Coupling large volume programmable temperature vaporizer (PTV-LV) injection to GC/MS/MS provides an alternative and complementary method to classical splitless-GC injection connected to high-resolution mass spectrometry (splitless-GC/HRMS) method for dioxin monitoring in food and feed.

An injection volume of 10 μl was found to be the best compromise between the sensitivity requirements and the robustness required for a high throughput method. PTV-LV-GC/MS/MS and Splitless-GC/HRMS were compared by performing analysis on five different matrices such as beef fat, yolk eggs, milk powder, animal feed and serum samples covering a concentration range of two orders of magnitude (i.e. 0.2–25 ng WHO-TEQ kg−1). An analysis of variance (ANOVA) was carried out. Fisher tests pointed out that the method effect for all the 2,3,7,8 congeners was not significant, indicating that the null hypothesis (H0: μ12=…=μn) was not rejected. Moreover, the interaction effects between methods and matrices were not significant for most of the 2,3,7,8 congeners. However, three congeners (2,3,7,8-TCDF; 1,2,3,4,7,8-HxCDD and 1,2,3,4,6,7,8-HpCDD) were characterized by P-values lower than the significance level (=0.05). In toxic equivalence (TEQ), the study showed that no significant bias was observed between the two methods. Consequently, PTV-LV-GC/MS/MS is an attractive technique and can be used as a cost effective complementary method to HRMS for dioxin levels monitoring in food and feed.  相似文献   


19.
随机选择空白的和经过印刷的新闻纸和复印纸 ,粉碎后用溶剂提取并经多步色谱柱纯化 ,采用同位素稀释、高分辨气相色谱 /高分辨质谱 (HRGC/HRMS)联用技术分析了其中的二含量。结果表明 :新闻纸中二的总量高于复印纸 ,但是毒性当量却低于复印纸 ;经过印刷的新闻纸和复印纸中二的含量均高于空白的新闻纸和复印纸 ;新闻纸和复印纸中相同二异构体的含量是不同的。空白的和经过印刷的新闻纸中二毒性当量分别为 0 4 8ng/kg和 0 6 1ng/kg,而空白的和经过印刷的复印纸中二毒性当量分别为 0 74ng/kg和 0 79ng/kg。所有样品中添加的13 C标记的 2 ,3,7,8位取代的二回收率均在 4 9 82 %至 131 34%之间。  相似文献   

20.
Simultaneous determination of PCDDs, PCDFs, PCBs and PBDEs in food   总被引:4,自引:0,他引:4  
Fernandes A  White S  D'Silva K  Rose M 《Talanta》2004,63(5):1147-1155
Established and comprehensively validated methodology for the analysis of PCDDs, PCDFs and polychlorinated biphenyls (PCBs) in food, animal feed and other matrices is presented. The method achieves the analytical standards of EU protocols (2002/69/EC and 2002/70/EC) that are used to determine the compliance of food and animal feed to maximum permissible levels of chlorinated dioxins in these commodities. The methodology provides WHO–TEQ data for dioxins and PCBs as well as individual concentrations for toxic PCDD/F congeners and >50 commonly occurring PCBs. In addition, the methodology allows the simultaneous determination of individual polybrominated diphenylether (PBDE) congeners. A wide range of 13Carbon-labelled surrogates allow accurate internal standardisation, and measurements are carried out using high resolution GC coupled to high resolution mass spectrometry except for mono-, tetra, ortho-substituted PCBs where unit resolution mass spectrometry can be used instead. Evidence of internal as well as external validation through the frequent use of reference materials, and successful participation in international inter-comparison exercises over many years is presented. A large number of different food types have been analysed for dioxins and PCBs using this methodology over several years and typical congener profiles for various food matrices are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏