首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
An industrial MCM‐41‐miniaturized matrix solid‐phase dispersion extraction coupled with response surface methodology was explored to determine L‐epicatechin, typhaneoside, isorhamnetin‐3‐O‐neohespeidoside, naringenin, kaempferol, and isorhamnetin in Pollen typhae by ultra‐high performance liquid chromatography connected to a photodiode array detection. Several variables were optimized in detail, including mesh number of sieve, type of adsorbent, mass ratio of sample to adsorbent, grinding time, methanol concentration, and elution volume. Central composite design was applied to optimize the best conditions for the maximum yields of the total flavonoids. The results displayed a good linear relationship (R > 0.9992) and the recoveries ranged from 92.9 to 103% (RSD < 4.53%) of the six flavonoids. The optimal method with high efficiency and low consumption was obviously better than heating reflux and ultrasonic extraction. It was proven that the developed industrial MCM‐41‐miniaturized matrix solid‐phase dispersion extraction coupled with simple ultra‐high performance liquid chromatography method could be a rapid and efficient tool for extraction and determination of flavonoids in natural products.  相似文献   

2.
A novel ionic‐liquid‐based vortex‐simplified matrix solid‐phase dispersion method using 2,6‐dimethyl‐β‐cyclodextrin was established by ultra high performance liquid chromatography coupled with a photodiode array detector. 2,6‐Dimethyl‐β‐cyclodextrin was first used as a promising adsorbent in this proposed method for simultaneous determination of eight compounds in Gardeniae fructus. These compounds are terpenoids (geniposidic acid, genipin‐1‐β‐D‐gentiobioside, geniposide, 8‐o‐acetyl shanzhiside methyl ester), crocins (crocin‐I, crocin‐II), quinic acid derivatives (chlorogenic acid), and flavonoids (isoquercitrin), respectively. Several parameters were investigated in the adsorption and desorption processes to obtain the optimal conditions, including 2,6‐dimethyl‐β‐cyclodextrin as sorbent, 0.5 mL 100 mM 1‐dodecyl‐3‐methylimidazolium hydrogen sulfate as the extraction solvent, 2:1 of sample/sorbent ratio, grinding for 2 min and vortexing for 60 s. The recoveries of the eight compounds ranged from 96.6 to 100% (<3.50%). The limits of detection and quantification were in the range of 0.02–0.30 and 0.06–1.25  μg/mL, respectively. Meanwhile, a good linearity was attained with r values (>0.9997). The established method showed higher extraction efficiency and less reagent consumption than traditional matrix solid phase dispersion and ultrasonic‐assisted extraction. Hence, it could be applied for sample preparation and analysis of natural products.  相似文献   

3.
In this study, chitosan‐zinc oxide nanoparticles were used as a sorbent of miniaturized matrix solid‐phase dispersion combined with flotation‐assisted dispersive liquid–liquid microextraction for the simultaneous determination of 13 n‐alkanes such as C8H18 and C20H42 in soil samples. The solid samples were directly blended with the chitosan nanoparticles in the solid‐phase dispersion method. The eluent of solid‐phase dispersion was applied as the dispersive solvent for the following flotation‐assisted dispersive liquid–liquid microextraction for further purification and enrichment of the target compounds prior to gas chromatography with flame ionization detection. Under the optimum conditions, good linearity with correlation coefficients in the range 0.9991 < r2 < 0.9995 and low detection limits between 0.08 to 2.5 ng/g were achieved. The presented procedure combined the advantages of chitosan‐zinc oxide nanoparticles, solid‐phase dispersion and flotation‐assisted dispersive liquid–liquid microextraction, and could be applied for the determination of n‐alkanes in complicated soil samples with acceptable recoveries.  相似文献   

4.
A simple and effective sample preparation process based on miniaturized matrix solid‐phase dispersion was developed for simultaneous determination of phenolic acids (gallic acid, chlorogenic acid, ferulic acid, 3,5‐dicaffeoylqunic acid, 1,5‐dicaffeoylqunic acid, rosmarinic acid, lithospermic acid, and salvianolic acid B), flavonoids (kaempferol‐3‐O‐rutinoside, calycosin, and formononetin), lactones (ligustilide and butyllidephthalide), monoterpenoids (paeoniflorin), phenanthraquinones (cryptotanshinone), and furans (5‐hydroxymethylfurfural) in Naoxintong capsule by ultra high‐performance liquid chromatography. The optimized condition was that 25 mg Naoxintong powder was blended homogeneously with 100 mg Florisil PR for 4 min. One milliliter of methanol/water (75:25, v/v) acidified by 0.05% formic acid was selected to elute all components. It was found that the recoveries of the six types of components ranged from 61.36 to 96.94%. The proposed miniaturized matrix solid‐phase dispersion coupled with ultra high‐performance liquid chromatography was successfully applied to simultaneous determination of the six types of components in Naoxintong capsules. The results demonstrated that the proposed miniaturized matrix solid‐phase dispersion coupled with ultra high‐performance liquid chromatography could be used as an environmentally friendly tool for the extraction and determination of multiple bioactive components in natural products.  相似文献   

5.
Matrix solid‐phase dispersion combined with dispersive liquid–liquid microextraction has been developed as a new sample pretreatment method for the determination of four sulfonylurea herbicides (chlorsulfuron, bensulfuron‐methyl, chlorimuron‐ethyl, and pyrazosulfuron) in tea by high‐performance liquid chromatography with diode array detection. The extraction and cleanup by matrix solid‐phase dispersion was carried out by using CN‐silica as dispersant and carbon nanotubes as cleanup sorbent eluted with acidified dichloromethane. The eluent of matrix solid‐phase dispersion was evaporated and redissolved in 0.5 mL methanol, and used as the dispersive solvent of the following dispersive liquid–liquid microextraction procedure for further purification and enrichment of the target analytes before high‐performance liquid chromatography analysis. Under the optimum conditions, the method yielded a linear calibration curve in the concentration range from 5.0 to 10 000 ng/g for target analytes with a correlation coefficients (r2) ranging from 0.9959 to 0.9998. The limits of detection for the analytes were in the range of 1.31–2.81 ng/g. Recoveries of the four sulfonylurea herbicides at two fortification levels were between 72.8 and 110.6% with relative standard deviations lower than 6.95%. The method was successfully applied to the analysis of four sulfonylurea herbicides in several tea samples.  相似文献   

6.
A new method for quantification of 12 nitroaromatic compounds including 2,4,6‐trinitrotoluene, its metabolites and 2,4,6‐trinitrophenyl‐N‐methylnitramine with microextraction by packed sorbent followed by gas chromatography and mass spectrometric detection in environmental and biological samples is developed. The microextraction device employs 4 mg of C18 silica sorbent inserted into a microvolume syringe for sample preparation. Several parameters capable of influencing the microextraction procedure, namely, number of extraction cycles, washing solvent, volume of washing solvent, elution solvent, volume of eluting solvent and pH of matrix, were optimized. The developed method produced satisfactory results with excellent values of coefficient of determination (R2 > 0.9804) within the established calibration range. The extraction yields were satisfactory for all analytes (> 89.32%) for aqueous samples and (> 87.45%) for fluidic biological samples. The limits of detection values lie in the range 14–828 pg/mL.  相似文献   

7.
A novel, low‐cost and effective in‐needle solid‐phase microextraction device was developed for the enrichment of trace polycyclic aromatic hydrocarbons in water samples. The in‐needle solid‐phase microextraction device could be easily assembled by inserting hydrofluoric acid‐etched wires, which were used as adsorbent, into a 22‐gauge needle tube within spring supporters. Compared with the commercial solid‐phase microextraction fiber, the developed device has higher efficiency for the extraction of polycyclic aromatic hydrocarbons with four to six rings from water samples using the optimized extraction conditions. With gas chromatography equipped with a flame ionization detector, the limits of detection for the polycyclic aromatic hydrocarbons with four to six rings ranged from 0.0020 to 0.0067 ng/mL. The relative standard deviations for one needle and needle‐to‐needle extractions were in the range of 5.2–9.9% (n = 5) and 3.4–12.3% (n = 5), respectively. The spiked recoveries of the polycyclic aromatic hydrocarbons in tap water samples ranged from 73.2 to 95.4%. This in‐needle solid‐phase microextraction device could be a good field sampler because of the low sample loss over a long storage time.  相似文献   

8.
The quantification of three alkaloids is important because quantitative study is a means of assessing the reliability of the experimental method, and three alkaloids of peimine, peiminine, and peimisine are main active ingredients in Chinese Pharmacopoeia 2015. An effective method based on the matrix solid‐phase dispersion microextraction was developed for the extraction of alkaloid compounds in Fritillariae Thunbergii Bulbus. Target analytes were analyzed by capillary electrophoresis coupled with quadrupole time‐of‐flight mass spectrometry. The optimized experimental condition was that 50 mg Fritillariae Thunbergii Bulbus was blended homogeneously with 10 mg citric acid for 5 min. Two hundred microliters of water acidized by 1 mol/L hydrochloric acid (pH = 4.5) was selected to elute tested alkaloids. The results demonstrated that the investigated method had low limits of detection (1.32–1.59 ng/mL), good recoveries (86.63–98.12%), and reproducibility (relative standard deviations of peak areas < 0.87%). The proposed matrix solid‐phase dispersion microextraction coupled with capillary electrophoresis combined with quadrupole time‐of‐flight mass spectrometry was successfully applied for the extraction of alkaloids in plants.  相似文献   

9.
In the present work, a high‐efficiency and solvent minimized microextraction technique, fabric phase sorptive extraction followed by gas chromatography and mass spectrometry analysis is proposed for the rapid determination of four organophosphorus pesticides (terbufos, malathion, chlorpyrifos, and triazofos) in vegetable samples including beans, tomato, brinjal, and cabbage. Fabric phase sorptive extraction combines the beneficial features of sol‐gel derived microextraction sorbents with the rich surface chemistry of cellulose fabric substrate, which collectively form a highly efficient microextraction system. Fabric phase sorptive extraction membrane, when immersed directly into the sample matrix, may extract target analytes even when high percentage of matrix interferents are present. The technique also greatly simplifies sample preparation workflow. Most important fabric phase sorptive extraction parameters were investigated and optimized. The developed method displayed good linearity over the concentration range 0.5–500 ng/g. Under optimum experimental conditions, the limits of detection were found in the range of 0.033 to 0.136 ng/g. The relative standard deviations for the extraction of organophosphorus pesticides were < 5%. Subsequently, the new method was applied to beans, tomato, brinjal, and cabbage samples. The results from the real sample analysis indicate that the method is green, rapid, and economically feasible for the determination of organophosphorus pesticides in vegetable samples.  相似文献   

10.
A method based on matrix solid‐phase dispersion extraction followed by ultra high performance liquid chromatography with tandem mass spectrometry is presented for the extraction and determination of phenolic compounds in Equisetum palustre. This method combines the high efficiency of matrix solid‐phase dispersion extraction and the rapidity, sensitivity, and accuracy of ultra high performance liquid chromatography with tandem mass spectrometry. The influential parameters of the matrix solid‐phase dispersion extraction were investigated and optimized. The optimized conditions were as follows: silica gel was selected as dispersing sorbent, the ratio of silica gel to sample was selected to be 2:1 (400/200 mg), and 8 mL of 80% methanol was used as elution solvent. Furthermore, a fast and sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the determination of nine phenolic compounds in E. palustre. This method was carried out within <6 min, and exhibited satisfactory linearity, precision, and recovery. Compared with ultrasound‐assisted extraction, the proposed matrix solid‐phase dispersion procedure possessed higher extraction efficiency, and was more convenient and time saving with reduced requirements on sample and solvent amounts. All these results suggest that the developed method represents an excellent alternative for the extraction and determination of active components in plant matrices.  相似文献   

11.
In this study, a simple and accurate sample preparation method based on dispersive solid‐phase extraction and dispersive liquid‐liquid microextraction has been developed for the determination of seven novel succinate dehydrogenase inhibitor fungicides (isopyrazam, fluopyram, pydiflumetofen, boscalid, penthiopyrad, fluxapyroxad, and thifluzamide) in watermelon. The watermelon samples were extracted with acetonitrile, cleaned up by dispersive solid‐phase extraction procedure using primary secondary amine, extracted and concentrated by the dispersive liquid‐liquid microextraction procedure with 1,1,2,2‐tetrachloroethane, and then analyzed by ultra high performance liquid chromatography with tandem mass spectrometry. The main experimental factors affecting the performance of dispersive solid‐phase extraction and dispersive liquid‐liquid microextraction procedure on extraction efficiency were investigated. The proposed method had a good linearity in the range of 0.1–100 µg/kg with correlation coefficients (r) of 0.9979–0.9999. The limit of quantification of seven fungicides was 0.1 µg/kg in the method. The fortified recoveries of seven succinate dehydrogenase inhibitor fungicides at three levels ranged from 72.0 to 111.6% with relative standard deviations of 3.4–14.1% (n = 5). The proposed method was successfully used for the rapid determination of seven succinate dehydrogenase inhibitor fungicides in watermelon.  相似文献   

12.
An analytical method is presented for the determination of paraben preservatives in semisolid cream samples by matrix solid‐phase dispersion combined with supramolecular solvent‐based microextraction. Due to the oily and sticky nature of the sample matrix, parabens were first extracted from the samples by matrix solid‐phase dispersion using silica as sorbent material with a clean‐up performed with tetrahydrofuran in the elution step. The eluate (500 μL), 1‐decanol (120 μL), and water (4.4 mL) were then mixed in a polyethylene pipette to form supramolecular solvent. Finally, the analytes in the supramolecular solvent were separated and determined by liquid chromatography with ultraviolet detection. Under optimal extraction conditions, the extraction recoveries of the studied compounds were obtained in the range of 63–83%. The limits of detection for the analytes were between 0.03 and 0.04 μg/g. The precision of the method varied between 4.0–6.7 (intraday) and 6.2–7.9% (interday). Finally, the optimized procedure was applied to the determination of the target preservatives in a variety of cream samples (diaper rash, skin allergy, face and hand moisturizing) with satisfactory recoveries (86–102%).  相似文献   

13.
New ternary deep eutectic solvents were prepared and applied as efficient green dispersing solvents in miniaturized matrix solid-phase dispersion to extract chlorophenols from river sediments for the first time. High-performance liquid chromatography coupled with a photodiode array detector was used to analyze the target analytes. The significant factors affecting the extraction were optimized as follows: dispersant (100 mg), sample (100 mg), ternary eutectic solvents (150 μl), grinding for 1 min, 450 μl of acetonitrile as the elution solvent, and vortex mixing for 20 s. Under the optimal conditions, the method exhibited excellent linearity (correlation coefficient > 0.9980), low limits of detection between 1.039–2.478 μg/g, and extraction recoveries between 93.9% and 99.2%. Furthermore, the method demonstrated excellent precision in the intra- and inter-day analysis with a relative standard deviation below 6%. When compared to conventional extraction techniques, the miniaturized matrix solid-phase dispersion considerably reduced samples and solvent usag, offering important environmental benefits. The green profile of the method was assessed using the complementary green analytical procedure index tool confirming its eco-friendship. The technique was finally employed to evaluate sediment samples from three distinct locations along the Zuibaiji River, indicating its applicability for monitoring environmental samples.  相似文献   

14.
In this research, a green approach for dispersive solid phase microextraction was introduced for the extraction and determination of melamine in various matrices such as infant formula and hot water in a melamine bowl. In this way, a natural polar polymer called ß-cyclodextrin has been cross-linked with citric acid to create a water-insoluble adsorbent. The extraction was carried out by dispersion of the sorbent into the sample solution. The effective parameters on the extraction efficiency of the melamine, including ion strength, extraction time, sample volume, amount of absorbent, pH, type of desorption solvent, desorption time, and desorption solvent volume were optimized by one variable at a time approach. Under the optimal conditions, the method showed a good linear dynamic range for melamine in the range of 1–1000 μg/L with a coefficient of determination of 0.9985. The obtained limit of detection was 0.3 μg/L. The intra-day and inter-day relative standard deviations (n = 3) were 3.1% and 3.2% respectively. Lastly, this technique was applied to extract and determine the analyte in a melamine bowl and infant formula with acceptable and satisfactory results.  相似文献   

15.
A simple, efficient, and sensitive strategy by coupling matrix solid‐phase dispersion with ultra high performance liquid chromatography quadrupole time‐of‐flight mass spectrometry was proposed to extract and determine three types of components (including seven analytes) in Chinese patent medicines Chenxiangqu. The highly ordered mesoporous material Fe‐SBA‐15 synthesized under weakly acidic conditions was selected as a dispersant in matrix solid phase dispersion extraction for the first time. Several parameters including the mass ratio of sample to dispersant, the type of dispersant, the grinding time, and the elution condition were investigated in this work. Under the optimized conditions, 20 compounds were identified by quadrupole time‐of‐flight mass spectrometry and seven analytes were quantified. The results demonstrated that the developed method has good linearity (r > 0.9995), and the limits of detection of the analytes were as low as 0.55 ng/mL. The recoveries of all seven analytes ranged from 97.6 to 104.6% (relative standard deviation < 3.4%). Finally, the improved method was successfully applied to determination of five batches of Chenxiangqu samples, which provided a robust method in quality control of Chinese patent medicines Chenxiangqu. The developed strategy also shows its great potential in analysis of complex matrix samples.  相似文献   

16.
Polypyrrole‐magnetite dispersive micro‐solid‐phase extraction method combined with ultraviolet‐visible spectrophotometry was developed for the determination of selected cationic dyes in textile wastewater. Polypyrrole‐magnetite was used as adsorbent due to its thermal stability, magnetic properties, and ability to adsorb Rhodamine 6G and crystal violet. Dispersive micro‐solid‐phase extraction parameters were optimized, including sample pH, adsorbent amount, extraction time, and desorption solvent. The optimum polypyrrole‐magnetite dispersive micro‐solid phase‐extraction conditions were sample pH 8, 60 mg polypyrrole‐magnetite adsorbent, 5 min of extraction time, and acetonitrile as the desorption solvent. Under the optimized conditions, the polypyrrole‐magnetite dispersive micro‐solid‐phase extraction with ultraviolet‐visible method showed good linearity in the range of 0.05–7 mg/L (R 2 > 0.9980). The method also showed a good limit of detection for the dyes (0.05 mg/L) and good analyte recoveries (97.4–111.3%) with relative standard deviations < 10%. The method was successfully applied to the analysis of dyes in textile wastewater samples where the concentration found was 1.03 mg (RSD ±7.9%) and 1.13 mg/L (RSD ± 4.6%) for Rhodamine 6G and crystal violet, respectively. It can be concluded that this method can be adopted for the rapid extraction and determination of dyes at trace concentration levels.  相似文献   

17.
Taxanes are natural anticancer constituents, and the sample preparation from matrix normally depends on organochlorine solvents. In this study, green and natural menthol‐based aqueous deep eutectic solvent was synthesized and used for sample preparation for taxanes. Five key parameters were optimized and the optimal preparation conditions were as follows: menthol/1‐propanol ratio 1:1 (mol/mol), solid–liquid ratio 1:30 g/mL, extraction time 30 min, ultrasonic power 250 W, and water content 80%. Under the above conditions, the total extraction efficiency of seven main taxanes was 1.25‐ to 1.44‐fold to the conventional methods. In addition, a high‐performance liquid chromatography method with C18 column was established for quantitation of seven main taxanes in <25 min, which had excellent linearity (R> 0.9986), precision (relative standard deviation < 3.00%), repeatability (relative standard deviation < 3.69%), and recovery (90.26–109.00%). This method performed the extraction, and enrichment processes simultaneously, and it had advantages such as high extraction efficiency, simple operation, low cost, and eco‐friendliness. This work indicated that the natural menthol‐based deep eutectic solvent aqueous could be an excellent alternative to the sample preparation from Taxus or other plants.  相似文献   

18.
Ionic liquids and derivatives—mainly polymeric ionic liquids and magnetic ionic liquids—have been extensively used in microscale extraction over the past few years. Current trends in analytical sample preparation gear toward linking microextraction approaches with high‐throughput sample processing to comply with green analytical chemistry requirements. A variety of high sample throughput strategies that are coupled to both ionic‐liquid‐based solid‐phase microextraction and ionic liquid‐based liquid‐phase microextraction are herein reported. The review is focused on microscale extraction methods that use (i) custom‐made and dedicated extraction devices, (ii) parallel extraction, (iii) magnetic‐based separation, and (iv) miniaturized systems employing semi‐automatic or fully automatic flow injection methods, related micro/millifluidic devices, and robotic equipment.  相似文献   

19.
A rapid, green and effective miniaturized sample preparation technique, ionic‐liquid‐assisted microwave distillation coupled with headspace single‐drop microextraction was developed for the extraction of essential oil from dried Dryopteris fragrans. 1‐Ethyl‐3‐methylimidazolium acetate was the optimal ionic liquid as the destruction agent of plant cell walls and microwave absorption was medium. n‐Heptadecane (2.0 μL) was adopted as the suspended microdrop solvent in the headspace for the extraction and concentration of essential oil. The optimal parameters of the proposed method were an irradiation power of 300 W, sample mass of 0.9 g, mass ratio of ionic liquids to sample of 2.8, extraction temperature of 79°C, and extraction time of 3.6 min. In comparison to the previous reports, the proposed technique could equally monitor all the essential oil components with no significant differences in a simple way, which was more rapid and required a much lower amount of sample.  相似文献   

20.
In this study, graphene‐encapsulated silica was synthesized by a hydrothermal reduction strategy. The presence of silica in graphene was identified by Fourier‐transform infrared spectrometry, X‐ray diffraction and scanning electron microscopy. The graphene‐encapsulated silica subsequently was used as adsorbent for matrix solid‐phase dispersion extraction of poly‐methoxylated flavonoids from the dried leaves of Murraya panaculata (L.) Jack. Compared with the other adsorbents (graphene, silica gel, C18 silica, neutral alumina, diatomaceous earth) and without any adsorbents, better results were obtained. Then a method for analysis of poly‐methoxylated flavonoids was established by coupling matrix solid‐phase dispersion extraction with ultra high performance liquid chromatography and UV detection. Compared with reflux extraction and ultrasonic extraction, the proposed method is quicker, more efficient and more environmental protection. Less than 10 min is needed from extraction to detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号