共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
5.
6.
7.
8.
Here, a two‐stage column separation scheme is developed for the concomitant isolation of Sr, Pb, Nd, and Hf from geological samples. The first column, which consists of three resin layers (AG50W‐X8 ion exchange resin + Ln specific resin + Sr specific resin), separates the high field strength element + rare earth element, Sr and Pb from the matrices. Subsequently, Nd and Hf are further separated from the high field strength element + rare earth element fraction on the second column using 1 mL of Ln specific resin. The two‐stage column process can be completed within about seven and a half hours for a batch of samples (20–30). The separated Sr fraction was ready for isotope ratio measurements by thermal ionization mass spectrometry. The Pb, Nd, and Hf fractions were converted to nitrate prior to isotopic analyses by multi‐collector inductively coupled plasma mass spectrometry. The feasibility of this new procedure is confirmed by the analyses of four international rock standards (BCR‐2, AGV‐2, BHVO‐2, and JB‐3), which yielded isotope ratios that were in good agreement with other published data. 相似文献
9.
10.
11.
《Rapid communications in mass spectrometry : RCM》2018,32(15):1215-1224
Rationale
Strontium isotope ratios (87Sr/86Sr) in modern‐day marine environments are considered to be homogeneous (~0.7092). However, in the Baltic Sea, the Sr ratios are controlled by mixing seawater and continental drainage from major rivers discharging into the Baltic. This pilot study explores if variations in Sr can be detected in marine mammals from archaeological sites in the Baltic Sea.Methods
87Sr/86Sr ratios were measured in tooth enamel from three seal species by laser ablation multi‐collector inductively coupled plasma mass spectrometry (LA‐MC‐ICP‐MS). The method enables micro‐sampling of solid materials. This is the first time that the method has been applied to marine samples from archaeological collections.Results
The analyses showed inter‐tooth 87Sr/86Sr variation suggesting that different ratios can be detected in different regions of the Baltic Sea. Furthermore, the intra‐tooth variation suggests possible different geographic origin or seasonal movement of seals within different regions in the Baltic Sea through their lifetime.Conclusions
The method was successfully applied to archaeological marine samples showing that: (1) the 87Sr/86Sr ratio in marine environments is not uniform, (2) 87Sr/86Sr differences might reflect differences in ecology and life history of different seal species, and (3) archaeological mobility studies based on 87Sr/86Sr ratios in humans should therefore be evaluated together with diet reconstruction.12.
Wang Zhongtang Wen Wei Quan Wei Du Liang Wang Ping Lin Jinxian Xie Yun Tan Zhaoyi 《Journal of Radioanalytical and Nuclear Chemistry》2018,316(1):411-417
Journal of Radioanalytical and Nuclear Chemistry - Plutonium is one of the key radionuclides in nuclear decommission. In this study, a rapid method was developed to analyze Pu for concrete samples... 相似文献
13.
U. Nygren H. Ramebäck C. Nilsson 《Journal of Radioanalytical and Nuclear Chemistry》2007,272(1):45-51
The age of plutonium is defined as the time since the last separation of the plutonium isotopes from their daughter nuclides.
In this paper, a method for age determination based on analysis of 241Pu/241Am and 240Pu/236Pu using ICP-SFMS is described. Separation of Pu and Am was performed using a solid phase extraction procedure including UTEVA,
TEVA, TRU and Ln-resins. The procedure provided separation factors adequate for this purpose. Age determinations were performed
on two plutonium reference solutions from the Institute for Reference Materials and Measurements, IRMM081 (239Pu) and IRMM083 (240Pu), on sediment from the Marshall Islands (reference material IAEA367) and on soil from the Trinity test site (Trinitite).
The measured ages based on the 241Am/241Pu ratio corresponded well with the time since the last parent-daughter separations of all the materials. The ages derived
from the 236U/240Pu ratio were in agreement for the IRMM materials, but for IAEA367 the determination of 236U was interfered by tailing from 238U, and for Trinitite the determined age was biased due to formation of 236U in the detonation of the “Gadget”. 相似文献
14.
15.
A sensitive and efficient flow-injection (FI) preconcentration and matrix-separation technique coupled to sector field ICP–mass spectrometry (SF-ICP–MS) has been developed and validated for simultaneous determination of ultra-low levels of uranium (U) and thorium (Th) in human urine. The method is based on selective retention of U and Th from a urine matrix, after microwave digestion, on an extraction chromatographic TRU resin, as an alternative to U/TEVA resin, and their subsequent elution with ammonium oxalate. Using a 10 mL sample, the limits of detection achieved for 238U and 232Th were 0.02 and 0.03 ng L–1, respectively. The accuracy of the method was checked by spike-recovery measurements. Levels of U and Th in human urine were found to be in the ranges 1.86–5.50 and 0.176–2.35 ng L–1, respectively, well in agreement with levels considered normal for non-occupationally exposed persons. The precision obtained for five replicate measurements of a urine sample was 2 and 3% for U and Th, respectively. The method also enables on-line measurements of the 235U/238U isotope ratios in urine. Precision of 0.82–1.04% (RSD) was obtained for 235U/238U at low ng L–1 levels, using the FI transient signal approach. 相似文献
16.
17.
Variations in Hg isotope ratios in cinnabar ores obtained from different countries were detected by high precision isotope ratio measurements using multi-collector inductively coupled mass spectrometry (MC-ICP-MS). Values of delta198/202Hg varied from 0.0-1.3 percent per thousand relative to a NIST SRM 1641d Hg solution. The typical external uncertainty of the delta values was 0.06 to 0.26 percent per thousand. Hg was introduced into the plasma as elemental Hg after reduction by sodium borohydride. A significant fractionation of lead isotopes was observed during the simultaneous generation of lead hydride, preventing normalization of the Hg isotope ratios using the measured 208/206Pb ratio. Hg ratios were instead corrected employing the simultaneously measured 205/203T1 ratio. Using a 10 ng ml(-1) Hg solution and 10 min of sampling, introducing 60 ng of Hg, the internal precision of the isotope ratio measurements was as low as 14 ppm. Absolute Hg ratios deviated from the representative IUPAC values by approximately 0.2% per u. This observation is explained by the inadequacy of the exponential law to correct for mass bias in MC-ICP-MS measurements. In the absence of a precisely characterized Hg isotope ratio standard, we were not able to determine unambiguously the absolute Hg ratios of the ore samples, highlighting the urgent need for certified standard materials. 相似文献
18.
19.
Lithium was determined in human serum by inductively coupled plasma mass spectrometry. Sample preparation was kept to the minimum: serum samples were diluted and beryllium was added as internal standard. Special attention was given to the choice of the internal standard and to the occurrence of memory effects. To test the accuracy of the method several biological reference materials were analysed, namely a “Second-Generation” Biological Reference Material (Freeze-Dried Human Serum) (University of Ghent), Human Serum SRM 909, Whole Egg Powder SRM 1845 and Mixed Human Diet SRM 1548 (National Institute of Standards and Technology). The results were compared with those obtained by other techniques. For the “second-generation” reference freeze-dried human serum a mean lithium concentration of 15.10 ng g?1 with a standard deviation of 0.54 ng g?1 dry weight was found. Analyses on serum samples from healthy individuals yielded lithium concentrations ranging from 0.22 to 0.97 μg l?1. 相似文献
20.
Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have been applied as the most important inorganic mass spectrometric techniques having multielemental capability for the characterization of solid samples in materials science. ICP-MS is used for the sensitive determination of trace and ultratrace elements in digested solutions of solid samples or of process chemicals (ultrapure water, acids and organic solutions) for the semiconductor industry with detection limits down to sub-picogram per liter levels. Whereas ICP-MS on solid samples (e.g. high-purity ceramics) sometimes requires time-consuming sample preparation for its application in materials science, and the risk of contamination is a serious drawback, a fast, direct determination of trace elements in solid materials without any sample preparation by LA-ICP-MS is possible. The detection limits for the direct analysis of solid samples by LA-ICP-MS have been determined for many elements down to the nanogram per gram range. A deterioration of detection limits was observed for elements where interferences with polyatomic ions occur. The inherent interference problem can often be solved by applying a double-focusing sector field mass spectrometer at higher mass resolution or by collision-induced reactions of polyatomic ions with a collision gas using an ICP-MS fitted with collision cell. The main problem of LA-ICP-MS is quantification if no suitable standard reference materials with a similar matrix composition are available. The calibration problem in LA-ICP-MS can be solved using on-line solution-based calibration, and different procedures, such as external calibration and standard addition, have been discussed with respect to their application in materials science. The application of isotope dilution in solution-based calibration for trace metal determination in small amounts of noble metals has been developed as a new calibration strategy. This review discusses new analytical developments and possible applications of ICP-MS and LA-ICP-MS for the quantitative determination of trace elements and in surface analysis for materials science. 相似文献