共查询到20条相似文献,搜索用时 15 毫秒
1.
《Journal of separation science》2018,41(11):2453-2460
A method for the determination of 16 polycyclic aromatic hydrocarbons in water has been developed. First, we made a solid‐phase extraction column. After this, the parameters affecting the efficacy of the experimental method were optimized, including appropriate selection of a solid‐phase extraction column and cleanup conditions on columns. The separation was achieved by gas chromatography and detection with triple quadrupole tandem mass spectrometry. The method showed satisfactory linearity (R2 > 0.999) over the range assayed (0.01–1 μg/mL), and limits of quantification ranging from 0.0011 to 0.0199 μg/L. The recoveries ranged from 83 to 113%. The relative standard deviation is in the range 0.86–3.1%. The results indicated that this method had high selectivity and precision that was suitable for the simultaneous determination of 16 polycyclic aromatic hydrocarbons in water. 相似文献
2.
Gynostemma pentaphyllum, a traditional herbal tea, and its flavonoids possess antioxidant activities. This study was carried out to isolate and identify these flavonoids from G. pentaphyllum and determinate the contents of the main flavonoids and their antioxidant activities. Nine flavonoids were determinated rapidly from G. pentaphyllum using medium-pressure liquid chromatography combined with other simple chromatographic methods. And nine flavonoids were identified as rutin (1), 4′-O-methyl-kaempferol-3-O-rutinoside (2), ombuoside (3), kaempferol-3-β-D-O-rutinoside (4), isorhamnetin-3-O-β-D-rutinoside (5), quercetin-3-O-β-D-glucoside (6), isorhamnetin (7), kaempferol (8), and quercetin (9) by liquid chromatography mass spectrometry-ion trap time of flight and 13C nuclear magnetic resonance spectroscopy, respectively. All of them displayed various potent antioxidant effects against the DPPH radical and A549 cell injury by using H2O2-generate peroxyl radicals in vitro . A sensitive and specific ultra-performance liquid chromatography coupled with multiple-reaction monitoring mode was utilized to rapidly analyze the main six flavonoids of the ethanol extract of G. pentaphyllum within less than 8?min using a Waters Acquity UPLC BEH C18 column. The contents of them were from 57.11 to 12907.74?µg/g in G. pentaphyllum. 相似文献
3.
In the present work, an ultra performance liquid chromatography (UPLC)-electrospray ionization tandem triple quadrupole/mass spectrometry (ESI-MS/MS) method was developed in selected reaction monitoring (SRM) mode to determine the amounts of seven/microcystin variants (MCYST-RR, -YR, -LR, -LA, -LY, -LW, -LF) in water samples. Solid phase extraction (SPE) or porous filter was used for sample cleaning-up and analyte enrichment. A C18 column enabled separation of 7 microcystins within 10 min. Translation reaction ions including 995.6 > 134.9 (RR), 1045.8 > 135.1 (YR), 910.9 > 375.7 (LA), 1002.3 > 375.6 (LY), 520.1 > 135.0 (LR), 1025.8 > 891.7 (LW), 986.8 > 852.6 (LF) were set as quantitative ions and the enkephalin was the internal standard. Upon method validation, the limits of detection (LODs) and limits of quantification (LOQs) were found to be 0.06 μg L−1 and 0.2 μg L−1 (injection volume of 10 μL), respectively, for all seven microcystin variants. The correlation coefficients were larger than 0.994 in all linear ranges and recoveries were in the range of 66.24-99.22%. The developed approach was highly sensitive and easy to perform. It generated accurate quantitative results for the analysis of microcystins in environmental water samples with a wide concentration range. The results showed that MC-RR and MC-LR widely existed in polluted water, while MC-LA and MC-LY were detected sporadically. 相似文献
4.
Martínez Ocaña R Mena Granero A Egea Gonzalez FJ Garrido Frenich A Martínez Vidal JL Plaza Bolaños P 《Analytical and bioanalytical chemistry》2008,390(5):1413-1423
A multiresidue method for determining 22 polychlorinated biphenyls (PCBs) in air has been developed and validated by gas chromatography
(GC) coupled to tandem mass spectrometry (MS/MS) using a triple quadrupole analyzer (QqQ). The method was validated in terms
of both steps of sampling and analysis. The sampling method, which is based on active sampling using polyurethane foam (PUF)
as adsorbent, was validated by generating standard atmospheres. The retention capacity of this sampling sorbent allows up
to 5 m3 of air to be sampled without any breakthrough for most compounds. Two solvent extraction methods were compared: sonication
and Soxhlet extraction with a mixture of n-hexane:diethyl ether (95:5 v/v). Both extraction methods yielded similar results, but the first one required less solvent
and time. The method exhibited good accuracy (80.3–99.8%), precision (2.2–15.2%) and lower limits that allowed quantification
and confirmation at levels as low as 0.008 ng/m3. Finally, the method was applied to the analysis of PCBs in the air in areas near to a municipal solid-waste landfill and
directly above the refuse in the landfill, where it indicatedd the presence of some of the target compounds.
Figure General chemical structure of polychlorinated biphenyls 相似文献
5.
Determination of priority organic micro-pollutants in water by gas chromatography coupled to triple quadrupole mass spectrometry 总被引:1,自引:0,他引:1
A multiclass method has been developed for screening, quantification and confirmation of organic micro-pollutants in water by gas chromatography coupled to mass spectrometry with a triple quadrupole analyzer. The work has been focused on the determination of more than 50 compounds belonging to different chemical families: 19 organochlorine and organophosphorus insecticides, 6 herbicides, 7 polychlorinated biphenyls, 16 polycyclic aromatics hydrocarbons, 2 brominated diphenyl ethers, and 3 octyl/nonyl phenols and pentachlorobenzene. Most of these analytes are included in the list of priority substances in the framework on European Water Policy.Analyte extraction was performed by solid phase extraction using C18 cartridges, and five isotopically labeled standards were added before extraction as surrogates. Analyses were performed by gas chromatography with tandem mass spectrometry (MS/MS) in electron impact mode. Accuracy and precision were evaluated by means of recovery experiments using water samples fortified at two concentration levels (25 and 250 ng L−1), with satisfactory results for most of analytes. The excellent selectivity and sensitivity reached in selected reaction monitoring mode allowed us satisfactory quantification and confirmation at levels as low as 25 ng L−1. Two MS/MS transitions were acquired for each analyte, using the Q/q intensity ratio as a confirmatory parameter. The method developed was applied to the analysis of surface, ground and wastewater samples collected from the Valencia Region (Spain).Analytical methodology using negative chemical ionization mode was also validated for the organochlorine compounds selected, showing a superior sensitivity and lower detection limits. 相似文献
6.
Yuan Zhang Wen‐jie Wu Wei‐e Zhou Zhi‐qin Ren Xue‐song Feng Feng Zhang 《Journal of separation science》2020,43(7):1372-1381
A novel, simple, and sensitive method has been developed for simultaneous determination of 14 heterocyclic aromatic amines in meat product using solid‐phase extraction combined with ultrahigh‐performance supercritical fluid chromatography coupled to tandem quadrupole mass spectrometry. The analytes could be separated within 7 min and identified using their retention times and mass. The developed method was validated based on the linearity, limits of quantification, precision, and accuracy. The recovery ranged from 52.3 to 97.5% with an acceptable standard deviation, which is not higher than 6%. The limits of quantitation ranged from 0.03 to 0.17 µg/kg. The selectivity and sensitivity were satisfactory in multiple reaction monitoring mode. The method was applied to commercial meat products, and the results demonstrated that the novel method has potential for the analysis of the targets in food matrices. This is the first work reporting the simultaneous quantification of 14 heterocyclic aromatic amines by means of ultrahigh‐performance supercritical fluid chromatography coupled to tandem quadrupole mass spectrometry. 相似文献
7.
《Journal of separation science》2017,40(3):671-676
An analytical method has been developed for the detection of a metabolite of nifursol, 3,5‐dinitrosalicylic acid hydrazide, in foodstuffs of animal origin (chicken liver, pork liver, lobster, shrimp, eel, sausage, and honey). The method combines liquid chromatography and tandem mass spectrometry with liquid–liquid extraction. Samples were hydrolyzed with hydrochloric acid and derivatized with 2‐nitrobenzaldehyde at 37°C for 16 h. The solutions of derivatives were adjusted to pH 7.0−7.5, and the metabolite was extracted with ethyl acetate. 3,5‐Dinitrosalicylic acid hydrazide determination was performed in the negative electrospray ionization method. Both isotope‐labeled internal standard and matrix‐matched calibration solutions were used to correct the matrix effects. Limits of quantification were 0.5 μg/kg for all samples. The average recoveries, measured at three concentration levels (0.5, 2.0, and 10 μg/kg) were in the range of 75.8–108.4% with relative standard deviations below 9.8%. The developed method exhibits a high sensitivity and selectivity for the routine determination and confirmation of the presence of a metabolite of nifursol in foodstuffs of animal origin. 相似文献
8.
采用高效液相色谱-三重四极杆质谱技术,建立了荔枝和香蕉中草铵膦及3种代谢物的检测分析方法。样品加水超声提取,离心沉淀后进样分析,分析物经Extend-C18色谱柱分离,以0.1%氨水-甲醇(9:1,v/v)作为流动相等度洗脱,在电喷雾负离子扫描、多反应监测模式下,外标法定量分析,同时探讨了前处理和仪器分析条件对草铵膦及代谢物的影响效果。结果表明,草铵膦及3种代谢物在1~1000 μg/L范围内,峰面积与质量浓度的线性关系良好;当添加浓度水平在50、100、1000 μg/kg时,草铵膦及代谢物在荔枝和香蕉中的平均回收率为82.9%~98.6%,相对标准偏差(RSD)为2.6%~6.3%,检出限(LOD)为5~10 μg/kg。本方法简化了样品前处理步骤,具有良好的可靠性和灵敏度,适于荔枝和香蕉中草铵膦及其代谢物的快速分析。 相似文献
9.
建立了超高效液相色谱-三重四极杆质谱法(UPLC-MS/MS)同时测定水粉画颜料、油画颜料、丙烯画颜料等美术颜料中33种初级芳香胺(PAAs)的检测方法。样品中的初级芳香胺用乙腈提取,经离心分离、氮吹浓缩后,以甲醇-水(1:9, v/v)定容至2 mL, 0.22 μm膜过滤后上机检测。采用BEH Phenyl柱(100 mm×2.1 mm, 1.7 μm),以含0.07%(v/v)甲酸的甲醇溶液-水(1:9, v/v)为流动相,梯度洗脱分离,UPLC-MS/MS多反应监测模式(MRM)检测,同位素内标法定量。方法优化了色谱分离条件、质谱碎裂电压、碰撞能量等,并考察了提取时间、提取溶剂、浓缩方式等对回收率的影响。33种初级芳香胺的方法检出限为5~50 μg/kg,定量限为15~150 μg/kg, 3种不同基质样品在3个添加水平的平均回收率为70.1%~115.8%,相对标准偏差(RSD)为2.1%~15%。本方法操作简便、快速、准确、灵敏度高,能满足相关测定的要求。 相似文献
10.
建立了一种基于母离子扫描模式的超高效液相色谱-三重四极杆质谱检测尿液中酰基肉碱的分析方法。对酰基肉碱类化合物所共有的m/z为60、85和144的碎片离子进行选择性检测,结合化合物母离子扫描的结果及其对应的保留时间,选取一致性较好的化合物进行筛选,再利用高分辨质谱确认,最终检测到37种酰基肉碱化合物,其中有14种尚未被HMDB和LIPID MAPS数据库收录。该方法可应用于其他生物样本(如血液、组织)中酰基肉碱的定性、定量分析,可作为检测酰基肉碱化合物的新选择。 相似文献
11.
Plasma lipid analysis by hydrophilic interaction liquid chromatography coupled with electrospray ionization tandem mass spectrometry 下载免费PDF全文
Kazuhiro Sonomura Shinobu Kudoh Taka‐Aki Sato Fumihiko Matsuda 《Journal of separation science》2015,38(12):2033-2037
A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono‐hexsosyl ceramide groups with good peak area repeatability (RSD% < 10) and linearity (R2 > 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co‐existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage. 相似文献
12.
建立了大鼠灌胃麻杏石甘汤后血浆中苦杏仁苷、野黑樱苷的定性及定量方法。样品经液液萃取净化处理,定性采用超高效液相色谱-串联四极杆飞行时间质谱仪(UPLC-QTOF-MS/MS),经Shim-pack XR-ODS Ⅲ色谱柱(75 mm×2.0 mm,1.6 μm)分离,定量采用超高效液相色谱-串联三重四极杆质谱仪(UPLC-Q-TRAP-MS),经Agilent C18色谱柱(50 mm×2.1 mm,1.7 μm)分离,电喷雾负离子化(ESI)及MRM模式测定,流动相均为乙腈-0.1%(v/v)甲酸水溶液。结果显示苦杏仁苷、野黑樱苷在相应浓度范围内线性关系良好(相关系数分别为0.9990、0.9970),精密度(RSD)小于9.20%,回收率为82.33%~95.25%,检出限(LOD)约为0.50 ng/mL。本方法快速简便,为血浆样品中苦杏仁苷、野黑樱苷的定性和定量分析提供良好参考。 相似文献
13.
Xiaoliang Liu Chunhong Ji Wenwei Tang Mingfeng Hu Huihua Tan Xuesheng Li Shaozhi Ma Xiangyang Yu Dongqiang Zeng 《Journal of separation science》2019,42(19):3141-3151
A simple and efficient multiresidue method using dispersive solid phase extraction and liquid chromatography coupled with tandem mass spectrometry was developed for the targeted analysis of indaziflam and its five metabolites (indaziflam‐diaminotriazine, indaziflam‐carboxylic acid, indaziflam‐triazine indanone, indaziflam‐hydroxyethyl, and indaziflam‐olefin) in pitaya samples (including roots, plants, flowers, peels, pulp, and whole fruit). The analytes were extracted with acetonitrile, and the extracts were purified using multiwalled carbon nanotubes. The method was validated using pitaya samples spiked at 0.5, 5, and 50 µg/kg, and the average recoveries varied from 61.1 to 103.7% with relative standard deviations lower than 12.7% (n = 5). This method exhibited sufficient linearity within the concentration range of 0.1–100 µg/L. The limits of detection and quantification were in the ranges of 0.001–0.1 and 0.003–0.3 µg/kg, respectively. The method was successfully applied to analyze pitaya samples in Nanning, and no indaziflam or its metabolites were detected in the samples analyzed. 相似文献
14.
液相色谱-串联四极杆飞行时间质谱和超高效液相色谱-串联三重四极杆质谱用于检测牛肉中的刚果红 总被引:1,自引:0,他引:1
建立了牛肉中刚果红的检测方法。定性方法采用液相色谱-串联四极杆飞行时间质谱对未知物进行质谱谱图库匹配,定量分析采用超高效液相色谱-串联三重四极杆质谱。牛肉样品中的刚果红经液液萃取净化后,采用Agilent ZORBAX Eclipse Plus C18 Rapid Resolution HD色谱柱(50 mm×2.1 mm, 1.8 μm)进行分离,流动相为95%(体积分数)甲醇,流速为0.2 mL/min。AB 4000+三重四极杆质谱仪在电喷雾负离子化(ESI)及MRM模式下定量。结果显示,刚果红在0.03~1 mg/L浓度范围内,线性关系良好(相关系数为0.9998),精密度良好(RSD小于5%),回收率为88%~91%,检出限约为0.01 mg/L。本方法快速简便,重现性好,可以为牛肉及其他肉制品中刚果红的定量提供良好的解决方案。 相似文献
15.
YuXi Chen Wei Chen Yan Lan KaiTeng Wang YongChen Wu XiaoLi Zhong KaiYang Ying JunYing Li GuiDi Yang 《Journal of separation science》2019,42(4):816-825
An ultra high performance liquid chromatography with triple quadrupole mass spectrometry method for the determination of free and bound phenolic acids in tobacco plant and soil was developed. A simple solid‐phase extraction, which used Polar Enhanced Polymer column as stationary phase and methanol as mobile phase, was used for the clean‐up of bound phenolic acids, and a liquid‐phase extraction using chloroform as solvent was used to purify free phenolic acids. With our method, 18 phenolic acids in rhizosphere soil of continuous cropping flue‐cured cultivar k326 were separated and determined within 6 min with recoveries of 82–107% and relative standard deviations (n = 5) of 1.1–4.8%. Results showed that free phenolic acids accounted for 0–9, 92–100, and 69–100% of total phenolic acids in rhizosphere soil, cultivar k326 roots and leaves, respectively. Results also revealed that p‐hydroxybenzoic acid, p‐coumaric acid, vanillic acid, ferulic acid, and syringic acid were the predominant phenolic acids in rhizosphere soil of cultivar k326, and continuous cropping of cultivar k326 in the same farmland could lead to the accumulation of these phenolic acids in soil except syringic acid. The determination of phenolic acids provided detailed information for evaluating their source and characteristics in continuous cropping tobacco plant and soil. 相似文献
16.
《Journal of separation science》2017,40(10):2123-2130
The characterization of unknown compounds is still a great challenge currently. A strategy for deduction of potential new phthalides through the characterization of isomers based on ultra‐performance liquid chromatography coupled with quadrupole time of flight tandem mass spectrometry was proposed here to characterize the unknown compounds of Ligusticum chuanxiong Hort. (Chuanxiong). This proposed strategy consisted of four steps: (1) the high resolution MS data was collected, and the peaks were screened preliminarily by UNIFITM platform based on the in‐house database; (2) the fragmentation patterns and the characteristic fragments were summarized based on the representative standards; (3) the target compounds were identified based on the fragmentation rules, standards comparison and false positive exclusion; (4) the unknown components were structurally characterized according to the accurate mass and fragmentation patterns analysis. This strategy was successfully applied to the identification and deduction of phthalides in Chuanxiong. A total of 81 phthalides were detected. Fifty‐five known phthalides were identified, and 26 potential new phthalides were characterized. This research enriched the material basis of Chuanxiong, and provided a liquid chromatography tandem mass spectrometry‐oriented method for the discovery of the potential new compounds. 相似文献
17.
Zhurui Li Xiaozhen Zhao Jiaojiao Chen Yue Wu Jing Zhang Kankan Zhang Deyu Hu 《Biomedical chromatography : BMC》2016,30(10):1625-1631
A fast and simple analytical method was developed for the simultaneous determination of RH‐5849 and indoxacarb in soil, rice straw, rice husk and brown rice. QuEChERS (quick, easy, cheap, effective, rugged and safe) method was used for extraction, and liquid chromatography with tandem triple quadrupole mass spectrometry was used for quantification. The matrix‐matched calibration plots were linear in the range between 25 and 5000 μg/L for soil, rice straw, rice husk and brown rice samples. All determination coefficients (R2) were ≥0.9962. The limits of detection and quantification were 1.5 and 5 μg/kg, respectively. Recoveries at three fortification levels ranged between 79.5 and 97.9% with relative standard deviations <11%. The developed method was validated and applied for the analysis of dissipation study samples. For field experiments, the half‐lives of RH‐5849 and indoxacarb in rice straw were 11.93 and 5.83 days, respectively. The method was demonstrated to be reliable for the routine monitoring of RH‐5849 and indoxacarb in rice samples. Copyright © 2016 John Wiley & Sons, Ltd. 相似文献
18.
In this study, a modified quick, easy, cheap, effective, rugged, and safe method combined with ultra‐high performance liquid chromatography and tandem mass spectrometry was developed for the multiclass determination of 28 plant growth regulators in various fruits. Different extraction solvents and adsorbents, including primary secondary amine, octadecylsilyl, graphitized carbon black, and zirconia‐based sorbent, were investigated. Internal calibration and isotope internal standards, chlormequat chloride‐d4, mepiquat chloride‐d6, indole‐3‐acetic acid‐d2, and forchlorfenuron‐d5 were used to improve accuracy. For method validation, good linearity, low limits of detection and quantification were obtained. At three spiked concentrations (10, 50, and 100 µg/kg), satisfactory recoveries with relative standard deviations of 2.4–17.5% were obtained for strawberries (75.2–119.8%), grapes (70.5–114.0%), tangerines (71.7–115.4%), apples (72.7–115.4%), and kiwi fruits (71.7–119.2%). Samples analysis revealed that 15.6% of the samples (n = 96) were contaminated with one or two kinds of plant growth regulators, including chlormequat chloride, forchlorfenuron, paclobutrazol, 2,4‐dichlorophenoxyacetic acid, 2‐diethylaminoethyl hexanoate, and mepiquat chloride. Similar results were obtained by ultra‐high performance liquid chromatography with quadrupole time‐of‐flight mass spectrometry, indicating the robustness, effectiveness, and suitability of the developed method for routine monitoring of plant growth regulator residues in fruits. 相似文献
19.
《Biomedical chromatography : BMC》2017,31(6)
In this study, an analytical method was developed for quantification of residues of the anthelmintic drug phenothiazine (PTZ) in pork muscle using liquid chromatography–tandem mass spectrometry. Muscles were extracted using 0.2% formic acid and 10 mm ammonium formate in acetonitrile, defatted and purified using n ‐hexane. The drug was well separated on a Waters XBridge™ C18 analytical column using a binary solvent system consisting of 0.2% formic acid and 10 mm ammonium formate in ultrapure water (A) and acetonitrile (B). Good linearity was achieved over a six‐point concentration range in matrix‐matched calibration with determination coefficient =0.9846. Fortified pork muscle having concentrations equivalent to and double the limit of quantification (1 ng/g) yielded recovery ranges between 100.82 and 104.03% and relative standard deviations <12%. Samples (n = 5) collected from large markets located in Seoul City tested negative for PTZ residue. In conclusion, 0.2% formic acid and ammonium formate in acetonitrile can effectively extract PTZ from pork muscle without solid‐phase extraction, a step normally required for cleanup before analysis and the validated method can be used for routine analysis to ensure the quality of animal products. 相似文献
20.
Assessment of tandem mass spectrometry and high‐resolution mass spectrometry for the analysis of bupivacaine in plasma 下载免费PDF全文
Fleur Gaudette Javier Benito Paulo Steagall Francis Beaudry 《Biomedical chromatography : BMC》2015,29(11):1724-1730
Triple quadrupole mass spectrometers coupled with high performance liquid chromatography are workhorses in quantitative bioanalyses. They provide substantial benefits including reproducibility, sensitivity and selectivity for trace analysis. Selected reaction monitoring allows targeted assay development but datasets generated contain very limited information. Data mining and analysis of nontargeted high‐resolution mass spectrometry profiles of biological samples offer the opportunity to perform more exhaustive assessments, including quantitative and qualitative analysis. The objectives of this study were to test method precision and accuracy, to statistically compare bupivacaine drug concentration in real study samples and to verify if high‐resolution and accurate mass data collected in scan mode can actually permit retrospective data analysis, more specifically, extract metabolite related information. The precision and accuracy data presented using both instruments provided equivalent results. Overall, the accuracy ranged from 106.2 to 113.2% and the precision observed was from 1.0 to 3.7%. Statistical comparisons using a linear regression between both methods revealed a coefficient of determination (R2) of 0.9996 and a slope of 1.02, demonstrating a very strong correlation between the two methods. Individual sample comparison showed differences from ?4.5 to 1.6%, well within the accepted analytical error. Moreover, post‐acquisition extracted ion chromatograms at m/z 233.1648 ± 5 ppm (M ? 56) and m/z 305.2224 ± 5 ppm (M + 16) revealed the presence of desbutyl‐bupivacaine and three distinct hydroxylated bupivacaine metabolites. Post‐acquisition analysis allowed us to produce semi‐quantitative evaluations of the concentration–time profiles for bupicavaine metabolites. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献