首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A fast and accurate micellar electrokinetic capillary chromatography (MEKC) method was developed for monitoring N-methyl-2-pyrrolidone (NMP) exposure. Baseline separation of NMP and its main metabolites: 5-hydroxy-N-methyl-2-pyrrolidone (5HNMP), N-methylsuccinimide (MSI), 2-hydroxy-N-methylsuccinimide (2HMSI), and 2-pyrrolidone (2P) was obtained within 6 min in an uncoated fused silica capillary using 5 mM phosphate buffer and 140 mM sodium dodecyl sulfate (pH 7.1) as background electrolyte (BGE). On-line UV-detection was performed at 200 nm and the applied electric field was 400 V cm−1. Possible interference of BGE-induced system peaks on separation was investigated by computer simulation and no such interference was observed. The developed MEKC method combined with solid phase extraction for sample preparation was successfully applied to the analysis of urine of rats exposed to NMP. The urinary excretion was determined in 0–6 h and 6–24 h specimens collected after an intragastic administration of 308 mg NMP / kg rat body weight. The results of NMP disposition kinetics in rat urine are reported for NMP and metabolites.   相似文献   

2.
Summary A method for the determination of 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methylsuccinimide (2-HMSI) in plasma was developed. 5-HNMP and 2-HMSI are metabolites to the widely used organic solvent N-methyl-2pyrrolidone (NMP). The 5-HNMP and 2-HMSI were purified from plasma by C8 solid phase extraction, derivatised by bistrimethylsilyl trifluoroacetamid, and analysed by gas chromatography with mass spectrometric detection. For 5-HNMP, the precision was 2–7 % (120 and 780 ng mL−1) and the detection limit was 6 ng mL−1 (m/z 98). For 2-HMSI, the precision was 2–9 % (160 and 1000 ng mL−1) and the detection limit was 4 ng mL−1 (m/z 144). The method is applicable for analysis of plasma samples from workers exposed to NMP.  相似文献   

3.
Summary A method was developed for the separation and quantification of the warfare nerve agent sarin (O-isopropylmethylphosphonoflouridate), its metabolite methylphosphonic acid, the anti nerve agent drug pyridostigmine bromide (PB;3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) and its metaboliteN-methyl-3-hydroxypyridinium bromide in rat plasma and urine. The method involved using solid phase extraction and high performance liquid chromatography (HPLC) with reversed phase C18 column, and UV detection at 280 nm. The compounds were separated using gradient of 1% to 55% acetonitrile in 0.1% triflouroacetic acid water solution (pH 3.20) at flow rate of 0.9 ml/min in a period of 15 min. The retention times ranged from 4.4–12.1 min. The limits of detection were 50 ng mL−1 for PB andN-methyl-3-hydroxypyridinium bromide, and 10 μg mL−1 for sarin and methylphosphonic acid, while limits of quantitation were between 100 ng mL−1–12 μg mL−1. Average percentage recovery of five spiked samples from plasma were 84.6±8.4, 86.5±9.0, 76.4±8.5, 81.3±8.2, and from urine 78.5±7.9, 76.4±7.8, 74.4±8.4, 80.6±6.8 for sarin, methylphosphonic acid, pyridostigmine bromide andN-methyl-3-hydroxypyridinium bromide, respectively. This method was applied to analyze the above chemicals and metabolites following combined administration in rats.  相似文献   

4.
Summary Direct chiral-phase HPLC methods have been developed for the determination of flurbiprofen and its major metabolites, namely 4′-hydroxyflurbiprofen and 3′-hydroxy-4′-methoxyflurbiprofen, in biological fluids using a derivatized amylose chiral stationary phase (CSP; Chiral-pak AD). Quantification of all three analytes, both free and conjugated, in urine was carried out following liquid-liquid extraction using tandem ultraviolet (UV) and fluorescence detection. Determination of flurbiprofen and the 4′-hydroxy-metabolite in plasma utilized the same CSP but required modification in the mobile phase composition and sole use of fluorescence detection. The urine assay was linear (r>0.998) between 0.05–10 μg mL−1, 0.1–20 μg mL−1 and 0.01–2 μg mL−1 for the enantiomers of flurbiprofen, 4′-hydroxyflurbiprofen and 3′-hydroxy-4′-methoxyflurbiprofen respectively. The plasma assay was linear (r>0.997) between 0.1–6 μg mL−1 and 0.01–0.6 μg mL−1 for the enantiomers of flurbiprofen and 4′-hydroxyflurbiprofen respectively. Both assays, typically yielded within- and between-day imprecision and accuracy values less than 10% for the enantiomers of the different analytes. Initial volunteer studies suggest that the disposition of flurbiprofen displays modest enantioselectivity in humans.  相似文献   

5.
Metabolism of four tobacco-specific N-nitrosamines (TSNAs), N′-nitrosonornicotine (NNN), N′-nitrosoanatabine (NAT), N′-nitrosoanabasine (NAB), and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) has been studied by solid-phase extraction (SPE) and liquid chromatography–tandem mass spectrometry (LC–MS–MS). 4-(Methylnitrosamino)-4-(3-pyridyl)-1-butanol (iso-NNAL) was used as internal standard. SPE and LC–MS–MS was found to be a rapid, simple, sensitive, and selective method for analysis of TSNAs in rabbit serum. The relative standard deviation (R.S.D., n = 6) for analysis of 5 ng mL−1 and 0.5 ng mL−1 standards and of serum sample spiked with 5 ng mL−1 standards of five TSNAs was 2.1–11% and recovery of 5 ng mL−1 standards from serum was 100.2–112.9%. A good linear relationship was obtained between peak area ratio and concentration in the range of 0.2–100 ng mL−1 for NNAL and 0.5–100 ng mL−1 for other four TSNAs, with correlation coefficients (R 2) >0.99 (both linear and log–log regression). Detection limits for standards in solvent were between 0.04 and 0.10 ng mL−1. Doses of TSNAs administered to rabbits via the auricular vein were 4.67 μg kg−1 and 11.67 μg kg−1, in accordance with the different levels in cigarettes. Metabolic curves were obtained for the four TSNAs and for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a metabolite of NNK; on the basis of these curves we modeled metabolic kinetic equations for these TSNAs by nonlinear curve fitting.  相似文献   

6.
A simple reversed-phase high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of the antiepileptic drugs (AEDs) zonisamide (ZNS), primidone (PRI), lamotrigine (LTG), phenobarbital (PB), phenytoin (PHT), oxcarbazepine (OXC), and carbamazepine (CBZ) and two of their active metabolites, monohydroxycarbamazepine (MHD) and carbamazepine 10,11-epoxide (CBZE) in human plasma. Plasma (100 μL) was pretreated by deproteinization with 300 μL methanol containing 20 μg mL−1 propranolol hydrochloride as internal standard. HPLC was performed on a C8 column (4.6 mm × 250 mm; particle size 5 μm) with methanol–acetonitrile–0.1% trifluoroacetic acid, 235:120:645 (v/v), as mobile phase at a flow rate of 1.5 mL min−1. ZNS, OXC, and CBZ were monitored by UV detection at 235 nm, and PRI, LTG, MHD, PB, PHT, and CBZE by UV detection at 215 nm. Relationships between response and concentration were linear over the concentration ranges 1–80 μg mL−1 for ZNS, 5–50 μg mL−1 for PRI, 1–25 μg mL−1 for LTG, 1–50 μg mL−1 for MHD, 5–100 μg mL−1 for PB, 1–10 μg mL−1 for CBZE, 0.5–25 μg mL−1 for OXC, 1–50 μg mL−1 for PHT, and 1–25 μg mL−1 for CBZ. Intra-day and inter-day reproducibility were adequate (coefficients of variation were ≤11.6%) and absolute recovery ranged from 95.2 ± 6.13 to 107.7 ± 7.76% for all the analytes; for the IS recovery was 98.69 ± 1.12%. The method was proved to be accurate, reproducible, convenient, and suitable for therapeutic monitoring of the nine analytes.  相似文献   

7.
A high-performance liquid chromatography–UV method for determining DCJW concentration in rat plasma was developed. The method described was applied to a pharmacokinetics study of intramuscular injection in rats. The plasma samples were deproteinized with acetonitrile in a one-step extraction. The HPLC assay was carried out using a VP-ODS column and the mobile phase consisting of acetonitrile–water (80:20, v/v) was used at a flow rate of 1.0 mL min−1 for the effective eluting DCJW. The detection of the analyte peak area was achieved by setting a UV detector at 314 nm with no interfering plasma peak. The method was fully validated with the following validation parameters: linearity range 0.06–10 μg mL−1 (r > 0.999); absolute recoveries of DCJW were 97.44–103.46% from rat plasma; limit of quantification, 0.06 μg mL−1 and limit of detection, 0.02 μg mL−1. The method was further used to determine the concentration–time profiles of DCJW in the rat plasma following intramuscular injection of DCJW solution at a dose of 1.2 mg kg−1. Maximum plasma concentration (C max) and area under the plasma concentration–time curve (AUC) for DCJW were 140.20 ng mL−1 and 2405.28 ng h mL−1.  相似文献   

8.
To evaluate the pharmacokinetics of a novel analogue of ginkgolide B, 10-O-dimethylaminoethylginkgolide B (XQ-1) in rat plasma in pre-clinical studies, a sensitive and specific liquid chromatographic method with electrospray ionization mass spectrometry detection (LC–ESI–MS) was developed and validated. After a simple extraction with ethyl acetate, XQ-1 was analyzed on a Shim-pack C18 column with a mobile phase of a mixture of 1 μmol L−1 ammonium acetate containing 0.02% formic acid and methanol (55:45, v/v) at a flowrate of 0.3 mL min−1. Detection was performed in selected ion monitoring (SIM) mode using target ions at [M + H]+ m/z 496.05 for XQ-1 and m/z 432.10 for the internal standard (lafutidine). Linearity was established for the concentration range from 2 to 1,000 ng mL−1 . The extraction recoveries ranged from 86.0 to 89.9% in plasma at concentrations of 5, 50, and 500 ng mL−1. The lower limit of quantification was 2 ng mL−1 with 100 μL plasma. The validated method was successfully applied to a pharmacokinetic study after intragastic administration of XQ-1 mesylate in rats at a dose of 20 mg kg−1.  相似文献   

9.
A new method was developed for the simultaneous determination of lidocaine, proline and lomefloxacin in human urine by capillary electrophoresis-electrochemiluminescence detection with Ru(bpy)3 2+. Conditions of the separation and detection were investigated and optimized. It was proved that 20 mM phosphate buffer at pH 6.7 could achieve the most favorable resolution, and the high sensitivity of detection was obtained by using the detection potential at 1.15 V and 5 mM Ru(bpy)3 2+–60 mM phosphate buffer at pH 7.6 in the detection reservoir. The detection limits were 0.02 μg mL−1 for lidocaine, 0.03 μg mL−1 for proline and 0.06 μg mL−1 for lomefloxacin. Relative standard deviations of the ECL intensity and the migration time were 3.5 and 1.1% for 6 μg mL−1 lidocaine, 3.2 and 1.0% for 6 μg mL−1 proline and 3.7 and 1.2% for 6 μg mL−1 lomefloxacin, respectively. A baseline separation for lidocaine, proline and lomefloxacin was achieved within 360 s. The developed method was successfully applied to determine the amounts of lidocaine, proline and lomefloxacin in human urine. The recovery and RSD were in the range of 93.3–97.2 and 3.8–4.9%, respectively.  相似文献   

10.
Summary A high-performance liquid chromatographic method, with 9-anthryldiazomethane as derivatizing agent, has been developed for the simultaneous determination ofN-carbamoyl aspartate andl-dihydroorotate in serum. Sample preparation for 1 mL serum was by simple liquid-liquid extraction and then derivatization. The compounds were separated on a Luna C18(2) column by use of a gradient prepared from acetonitrile and 10 mM sodium acetate buffer, pH 6.0, and fluorimetric detection was performed at excitation and emission wavelengths of 365 nm and 412 nm, respectively. The response was found to be linearly dependent on concentration between 0.8 and 60 μg mL−1 forl-dihydrooratate and between 0.9 and 90 μg mL−1 forN-carbamoyl aspartate; the mean recovery rates were 50 and 51%, respectively. The limits of detection and quantification were 0.33 μg mL−1 and 0.6 μg mL−1, respectively, forl-dihydroorotate and 0.4 μg mL−1 and 0.7 μg mL−1 forN-carbamoyl aspartate. This method can be used to assess accumulation ofN-carbamoyl aspartate andl-dihydroorotate in body fluids in situations where cellular pyrimidine de novo synthesis is impaired.  相似文献   

11.
D. Sircar  G. Dey  A. Mitra 《Chromatographia》2007,65(5-6):349-353
A reverse phase HPLC method was developed and validated for the simultaneous determination of 2-hydroxy-4-methoxybenzaldehyde and 2-hydroxy-4-methoxybenzoic acid in the root extracts of Hemidesmus indicus. A comprehensive validation of the method including sensitivity, linearity, reproducibility, accuracy, limit of detection (LOD) and limit of quantification (LOQ) was conducted using the optimized chromatographic conditions. The method was found to be linear (r > 0.998) in the range of 5–350 μg mL−1 for 2-hydroxy-4-methoxybenzaldehyde and for 2-hydroxy-4-methoxybenzoic acid (r > 0.999) in the range 10–300 μg mL−1. The method was found to be precise with inter-day precision values (% RSD) in the ranges of 0.61–1.76% for 2-hydroxy-4-methoxybenzaldehyde and 1.3–2.8% for 2-hydroxy-4-ethoxybenzoic acid while intra-day precisions (% RSD) of two analytes were in the range of 0.41–1.07 and 0.95–2.5%. The limits of detection (LODs) for 2-hydroxy-4-methoxybenzaldehyde and 2-hydroxy-4-methoxybenzoic acid were 0.84 and 2.34 μg mL−1. The described method was fast, sensitive and reproducible, and thus well suited for routine analysis of these two compounds from root extracts of H. indicus and other plants.  相似文献   

12.
Summary A reliable and sensitive high-performance liquid chromatographic method for the determination of the recent antidepressant citalopram and two metabolites in human plasma has been developed. Fluorescence detection at 300 nm was used, exciting at 238 nm. Separation was obtained using a reversed-phase column (C18, 250 × 3.0 mm i.d., 5 μm) and a mobile phase. 40% acetonitrile: 60% aqueous tetramethylammonium perchlorate (pH 1.9). Calibration curves were linear over a working range: 5–300 ng mL−1 for citalopram, 2.5–150.0 ng mL−1 for desmethylcitalopram and 2.5–50.0 ng mL−1 for didesmethylcitalopram. The limits of quantitation (LOQ) were 1.5 ng mL−1 for citalopram and desmethylcitalopram and 2.0 ng mL−1 for didesmethylcitalopram. Precision data, as well as accuracy, were satisfactory and no interference from different psychotropic drugs was found. The method was therefore suitable for therapeutic drug monitoring of citalopram and its active metabolites in plasma of depressed patients.  相似文献   

13.
Summary A rapid and simple liquid-chromatographic method has been developed for on-line quantification of amphetamine in biological fluids. Untreated samples (20 μL) are injected directly into the chromatographic system and purified on a 20 mm×2.1 mm i.d. pre-column packed with 30 μm Hypersil C18 stationary phase. After clean-up the analyte is transferred to the analytical column (125 mm×4 mm i.d., 5 μm LiChrospher 100 RP18) for derivatization and separation using a mixture of acetonitrile and the derivatization reagent (o-phthaldialdehyde andN-acetyl-L-cysteine) as the mobile phase. The experimental conditions for on-line derivatization and resolution of the amphetamine have been optimized, and the results have been compared with those obtained by derivatizing the analyte in pre-column mode. The method described has been applied to the determination of amphetamine in plasma and urine. Good linearity and reproducibility were obtained in the 0.1–10.0 μg mL−1 concentration range, and limits of detection were 25 ng mL−1 and 10 ng mL−1 with UV and fluorescence detection, respectively. The procedure described is very simple and rapid, because no off-line manipulation of the sample is required; the total analysis time is approximately 8 min.  相似文献   

14.
Aidi injection is a clinical medicine used in China for the treatment of cancer. Calycosin-7-O-β-d-glucoside is the main effective components of the formulas. In this study, a high performance liquid chromatographic (LC) method was developed to quantify calycosin-7-O-β-d-glucoside in rat plasma using a liquid–liquid extraction and ultraviolet (UV) absorbance detection. LC analysis was performed on a Diamonsil C18 column (200 × 4.6 mm i.d., 5 μm particle size) with isocratic mobile phase consisting of acetonitrile–0.05% phosphoric acid (19.5:80.5, v/v) of a flow rate of 1.0 mL min−1. The linear range was 0.11–17.6 μg mL−1 and the low quantification limit was 0.11 μg mL−1 (S/N = 10). The intra- and inter-day relative standard deviations (RSD) in the measurement of quality control (QC) samples 0.11, 0.22, 1.32 and 8.80 μg mL−1 ranged from 4.1 to 6.3 and 4.3 to 6.2%, respectively. The accuracy was from −6.7 to 4.3% in terms of relative error (RE). Calycosin-7-O-β-d-glucoside was stable in storage at −20 °C for 2 weeks and stable after three freeze–thaw cycles in rat plasma. This method was validated for specificity, accuracy, precision and was successfully applied to pharmacokinetic study of calycosin-7-O-β-d-glucoside in rat plasma after intravenous administration of Aidi lyophilizer.  相似文献   

15.
An integrated solid-phase spectrophotometry–FIA method is proposed for simultaneous determination of the mixture of saccharin (1,2-benzisothiazol-3(2H)-one-1,1-dioxide; E-954) (SA) and aspartame (N-l-α-aspartyl-l-phenylalanine-1-methyl ester; E-951) (AS). The procedure is based on on-line preconcentration of AS on a C18 silica gel minicolumn and separation from SA, followed by measurement, at λ=210 nm, of the absorbance of SA which is transiently retained on the adsorbent Sephadex G-25 placed in the flow-through cell of a monochannel FIA setup using pH 3.0 orthophosphoric acid–dihydrogen phosphate buffer, 3.75×10–3 mol L−1, as carrier. Subsequent desorption of AS with methanol enables its determination at λ=205 nm. With a sampling frequency of 10 h−1, the applicable concentration range, the detection limit, and the relative standard deviation were from 1.0 to 200.0 μg mL−1, 0.30 μg mL−1, and 1.0% (80 μg mL−1, n=10), respectively, for SA and from 10.0 to 200.0 μg mL−1, 1.4 μg mL−1, and 1.6% (100 μg mL−1, n=10) for AS. The method was used to determine the amounts of aspartame and saccharin in sweets and drinks. Recovery was always between 99 and 101%. The method enabled satisfactory determination of blends of SA and AS in low-calorie and dietary products and the results were compared with those from an HPLC reference method.  相似文献   

16.
A sensitive and specific liquid chromatographic method with electrospray ionization mass spectrometry (LC–ESI-MS) has been developed and validated for identification and quantification of mitiglinide in human urine. A simple liquid–liquid extraction procedure was followed by separation on a C18 column with gradient elution, and detection using a single-quadrupole mass spectrometer in selected-ion-monitoring (SIM) mode. The method was tested using six different batches of urine. Linearity was established for the mitiglinide concentrations in the range 0.005–1.0 μg mL−1, with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. Intra- and inter-day precision (as RSD, %) was below 10% and accuracy for mitiglinide ranged from 85 to 115%. The lower limit of quantification was reproducible at 0.002 μg mL−1 for 500 μL urine. The proposed method enables unambiguous identification and quantification of mitiglinide in pre-clinical and clinical studies.  相似文献   

17.
A novel method using liquid chromatography coupled with atmospheric pressure chemical ionization mass spectrometry in the negative selected ion monitoring mode has been developed and validated for rapid simultaneous determination of triptolide and tripdiolide in the extract of Tripterygium wilfordii Hook. f. The molecular ions m/z [M–H] 359 and 375 were selected for the quantification in selected ion monitoring mode for triptolide and tripdiolide. Standard calibration curve was linear over the concentration range of 0.12–24 and 0.15–30 μg mL−1 for triptolide and tripdiolide. The relative standard deviations of intra- and inter-day were in the range of 4.7–9.9 and 8.9–12.6%. The average recoveries were between 96.4 and 104.6%. The limits of quantitation were 2.0 × 10−3 and 2.5 × 10−3 μg mL−1 for triptolide and tripdiolide.  相似文献   

18.
Simple, sensitive, and reproducible off-line solid-phase microextraction and liquid chromatography (SPME/LC) methods are described for the determination of seven anticonvulsants and tricyclic antidepressants in human plasma. Factorial design and simplex methodology were applied in the optimization of the SPME procedure for tricyclic antidepressants analyses. Important factors in the SPME efficiency are discussed, such as the fiber coatings (both lab-made and commercial), extraction time, pH, ionic strength, influence of plasma proteins, and desorption conditions. The development of the lab-made fiber coatings, namely, octadecylsilane, aminosilane, and polyurethane, are further described and applied to anticonvulsants analyses. The investigated plasmatic range for the evaluated anticonvulsants, using CW-TPR fiber, were the following: phenylethylmalonamide (3.00–40.0 μg mL−1), phenobarbital (5.00–40.0 μg mL−1), primidone (3.00–40.0 μg mL−1), carbamazepine and carbamazepine-epoxide (2.00–24.0 μg mL−1), phenytoin (2.00–40.0 μg mL−1), and lamotrigine (0.50–12.0 μg mL−1). The antidepressants’ linear plasmatic concentration ranged from 75.0 to 500 ng mL−1 for imipramine, amitriptyline, and desipramine, and from 50.0 to 500 ng mL−1 for nortriptyline, being in all cases, the limit of quantification represented by the lowest value. The precision (interassays) for all investigated drugs in plasma sample spiked with different concentrations of each analyte and submitted to the described procedures were lower than 15%. The off-line SPME/LC methodologies developed allow anticonvulsants and antidepressants analyses from therapeutic to toxic levels for therapeutic drug monitoring.  相似文献   

19.
A method for the determination of total N-acetylcysteine and thioglycolic acid in human urine is described. Because these compounds are mainly excreted as disulfides, they are first reduced to the free thiols by treatment with tris(2-carboxyethyl)phosphine hydrochloride and then derivatized with 2-chloro-1-methylquinolinium tetrafluoroborate. Separation and quantitation of the 2-S-quinolinium derivatives of the thiols were achieved by reversed-phase ion-pair liquid chromatography with UV-detection at 355 nm. Because the method enables simultaneous determination of other endogenous urinary thiols, e.g. cysteine and cysteinylglycine, amounts of these compounds in urine were also studied. Detector responses were linear over the range covering most practical situations, with correlation coefficients for all four analytes better than 0.999. Recovery and imprecision (as RSD) were within 99.77–102.17 and 0.01–7.79%, respectively. The lower limit of detection was 0.25 μmol L−1 urine for thioglycolic acid and N-acetylcysteine, and 0.12 μmol L−1 urine for cysteine and cysteinylglycine. The method was used for analysis of urine samples from 29 healthy individuals to establish reference values for the thiols, normalized to creatinine. 3-Mercaptolactic acid, 2-mercaptopropionic acid, and mercaptoethanol were not present in the urine analyzed.  相似文献   

20.
Eprinomectin is a novel and potent antiparasitic animal health drug. An analytical procedure for the determination of EPR in bovine urine and feces has been developed. The urine sample was centrifuged and alkalized with ammonia following solid phase extraction. The fecal sample was extracted with acetonitrile, defatted with hexane, cleaned-up using C18 cartridge. All samples were analyzed by high performance liquid chromatography with fluorescence detection after derivatization with N-methylimidazole. The limits of detection are 0.5 ng mL−1 and 0.5 ng g−1, respectively. Fortified at 2, 10, 50, and 100 ng mL−1(ng g−1), inter-assay recoveries of EPR in cattle urine and feces were in the range of 87.9–91.5% and 78.6–86.3%, with coefficients of variation of 5.4–10.2% and 1.4–7.2%, respectively. Intra-assay mean recoveries of the analytes were 82.2–86.5% and 79.6–87.3%, with coefficients of variation of 7.8–11.5% and 6.3–7.8%, respectively. The method was used to study the excretion of eprinomectin in bovine urine and feces after subcutaneous administration at a dose of 0.5 mg kg−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号