首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 27 毫秒
1.
建立了浊点萃取-分光光度法测定痕量NO2-根的方法.以对氨基苯磺酸和α-萘胺为络合剂,非离子型表面活性剂TritonX-100为萃取剂,富集、分离水样中痕量NO2-,采用可见吸收光谱法进行检测.研究了溶液的酸度、试剂用量、平衡时间、平衡温度、干扰离子对浊点萃取效果的影响,并得到最佳实验条件:5%的TritonX-100用量2.0mL、平衡温度85℃、平衡时间10min、对氨基苯磺酸和α-萘胺均为0.3mL、0.1mol/LH2SO4溶液0.5mL.在最佳实验条件下,对氨基苯磺酸、α-萘胺和NO2-生成的络合物被萃取到TritonX-100表面活性剂相并与水相分开.该方法适用于环境水样中痕量NO2-的测定.  相似文献   

2.
A new micelle-mediated cloud point extraction method is described for sensitive and selective determination of trace amounts of rhodamine B by spectrophotometry. The method is based on the cloud point extraction of rhodamine B from aqueous solution using Triton X-100 in acidic media. The extracted surfactant rich phase is diluted with water and its absorbance is measured at 563 nm by a spectophotometer. The effects of different operating parameters such as concentration of surfactant and salt, temperature and pH on the cloud point extraction of rhodamine B were studied in details and a set of optimum conditions were obtained. Under optimum conditions a linear calibration graph in the range of 5-550 ng mL−1 of rhodamine B in the initial solution with r = 0.9991 (n = 15) was obtained. Detection limit based on three times the standard deviation of the blank (3Sb) was 1.3 ng mL−1 (n = 10) and the relative standard deviation (R.S.D.) for 50 and 350 ng mL−1 of rhodamine B was 2.40 and 0.87% (n = 10), respectively. The method was applied for the determination of rhodamine B in soft pastel, hand washing liquid soap, matches tip and textile dyes mixture samples.  相似文献   

3.
浊点萃取光度法测定水样中亚硝酸根   总被引:1,自引:0,他引:1  
A new method for the determination of trace nitrite by spectrophotometric after cloud point extraction was proposed.The effects of experimental conditions such as acidity,concentration of chromogenic reagent and surfactant,equilibration temperature and time on cloud point extraction were discussed.Under the optimum conditions,a good linear relationship was obtained in the range of 4.0~200 μg/L of the nitrite(r=0.9998),the detection limits of 0.43 μg/L.The recoveries fell in the range from 97.7% to 102.4% an...  相似文献   

4.
A novel method for the spectrophotometric determination of nitrite in water   总被引:4,自引:0,他引:4  
Aydın A  Ercan O  Taşcıoğlu S 《Talanta》2005,66(5):1181-1186
A rapid, simple, selective and sensitive method for the spectrophotometric determination of nitrite in water has been developed and optimum reaction conditions along with other analytical parameters have been evaluated. Nitrite reacts with barbituric acid in acidic solution to give the nitroso derivative, violuric acid. At analytical wavelength of 310 nm, Beer's law is obeyed over the concentration range 0.00–3.22 ppm of nitrite. The molar absorptivity is 15330 ± 259.7 (95%) with pooled standard deviation of 355.57 and R.S.D. of 2.32%. As well as the method is sensitive (2.99 × 10−3 μg NO2 cm−2) and selective, it tolerates most of the potential interferents. It has been successfully applied to nitrite determination in natural waters by use of a calibration graph with determination limit of 1.66 μg NO2 in 100 mL working solution corresponding to minimum 9.5 ppb NO2–N in water samples. Lower concentrations of nitrite (3.0 μg NO2/L sample) is precisely analyzed by using the method of dilution with sample, with R.S.D. of lower than 0.5%. The results were compared with standard N-(1-naphtyl)ethylenediamine dihydrochloride method and very good agreement between the data was observed. The method can easily be applied in the field.  相似文献   

5.
The possibility to use 4-(2-pyridylazo)resorcinol (PAR) and 1-(2-pyridylazo)-2-naphthol (PAN) for manganese(II) concentrating by the micellar extraction at cloud point (CP) temperature and subsequent atomic absorption spectrometry (AAS) determination was investigated. Under the optimum conditions, preconcentration of 100 ml of water sample in the presence of 1% non-ionic surfactant (NS) OP-7, 1×10−4 M 1-(2-pyridylazo)-2-naphthol permitted the detection 5 μg l−1 manganese. The proposed method has been applied to the AAS determination of manganese in water samples after cloud point extraction.  相似文献   

6.
Pourreza N  Ghomi M 《Talanta》2011,84(1):240-243
A novel simultaneous cloud point extraction method for the determination of carmoisine and brilliant blue FCF by spectrophotometry has been developed. The method is based on the cloud point extraction of carmoisine and brilliant blue FCF from aqueous solution using Triton X-100, diluting the extracted surfactant rich phase with water and measuring the absorbance at 522 and 640 nm for carmoisine and brilliant blue FCF, respectively. The effects of different parameters such as pH, concentration of surfactant and temperature on the cloud point extraction of both dyes were investigated and optimum conditions were established. Linear calibration curves were obtained in the range of 0.02-3.50 μg mL−1 for carmoisine and 0.05-3.50 μg mL−1 for brilliant blue FCF under optimum conditions. Detection limit based on three times the standard deviation of the blank (3Sb) was 0.017 and 0.016 μg mL−1 (n = 10) for carmoisine and brilliant blue FCF, respectively. The relative standard deviation (RSD) for 0.1 μg mL−1 was 4.14 and 3.30% (n = 10), for carmoisine and brilliant blue FCF, respectively. The method was applied to the simultaneous determination of the dyes in different food samples.  相似文献   

7.
Yue XF  Zhang ZQ  Yan HT 《Talanta》2004,62(1):97-101
A new flow injection catalytic spectrophotometric method is proposed for the simultaneous determination of nitrite and nitrate based on the catalytic effect of nitrite on the redox reaction between crystal violet and potassium bromate in phosphoric acid medium and nitrate being on-line reduced to nitrite with a cadmium-coated zinc reduction column. The redox reaction is monitored spectrophotometrically by measuring the decrease in the absorbance of crystal violet at the maximum absorption wavelength of 610 nm. A technique of inserting a reduction column into sampling loop is adopted and the flow injection system produces a signal with a shoulder. The height of shoulder in the ascending part of the peak corresponds to the nitrite concentration and the maximum of the peak corresponds to nitrate plus nitrite. The detection limits are 0.3 ng ml−1 for nitrite and 1.0 ng ml−1 for the nitrate. Up to 32 samples can be analyzed per hour with a relative standard deviation of less than 2%. The method has been successfully applied for the simultaneous determination of nitrite and nitrate in natural waters.  相似文献   

8.
A new approach, employing cloud point extraction (CPE) in combination with thermal lens spectrometry (TLS), has been developed for the determination of cobalt. The CPE and TLS methods have good matching conditions for combination because TLS is suitable for low volume samples obtained after CPE and for organic solvents, which are used for dissolving the remaining analyte phase.1-(2-Pyridylazo)-2-naphthol (PAN) was used as a complexing agent and octylphenoxypolyethoxyethanol (Triton X-114) was added as a surfactant; then the pH of solution was adjusted. After phase separation at 50 °C based on the cloud point extraction of the mixture, the surfactant-rich phase was dried and the remaining phase was dissolved using 20 μL of carbon tetrachloride. The obtained solution was introduced into the quartz micro cell and the analyte was determined by thermal lens spectrometry. The He-Ne laser (632.8 nm) was used as both the probe and the excite source.Under optimum conditions, the analytical curve was linear for the concentration range of 0.2-40 ng mL−1 and the detection limit was 0.03 ng mL−1. The enhancement factor of 470 was achieved for a 10 mL sample. Relative standard deviations were lower than 5%.The method was successfully applied to the extraction and determination of cobalt in tap, river and sea water.  相似文献   

9.
The possibility to use monocarboxylic acids and their mixtures with amines for copper concentrating by the way of micellar extraction at cloud point temperature, and later atomic absorption spectrometry (AAS) determination was investigated. Under the optimum conditions, preconcentration of 100 ml of water sample in the presence of 1% non-ionic surfactant OP-10, 0.005 M capric acid and 0.01 M octylamine permitted the detection of 0.01 μg ml−1 copper. The proposed method has been applied to the AAS determination of copper in water samples after cloud point extraction.  相似文献   

10.
A novel cloud point phase separation of cationic surfactant, Aliquat-336 and capabilities of its reactive solubilizing sites for selective extraction of chromium species at ultra trace levels was examined in natural water. The phase separation behavior of Aliquat-336 is studied with various additives. The nonionic surfactant, Triton X-114 was found to induce the cloud point phase separation of Aliquat-336. The separation of anionic Cr(VI) was enabled by the formation of ion associate with quaternary ammonium head group of Aliquat-336 at pH 2, and the recovery of Cr(VI) and Cr(III) were 101.4 ± 1.4% and 2.2 ± 0.4%, respectively at 0.5-1 ng mL−1, Total Cr was pre-concentrated as Cr-APDC species using the hydrophobic tail group at pH 6.5. The Cr(III) concentration was obtained by subtracting Cr(VI) from total Cr. The recovery of total Cr was 99.5 ± 1.2%. Parameters affecting extraction were assessed. The procedure was applied to NIST 1643c and NIST 1643d waters, and the sum of individual species obtained was compared with the certified chromium values. The method was also applied to various natural waters with limits of detection and pre-concentration factor of 0.010 and 0.025 ng mL−1; 10 and 10, respectively, for Cr(VI) and Cr(III)-APDC using ICP-MS operated in DRC mode.  相似文献   

11.
This work describes a new, simple, and sensitive colorimetric determination method for indoxyl sulfate (indican) by fiber optic UV-Vis spectrophotometry coupled to cloud point extraction as the separation-preconcentration method. This method is based on the diazotization of sulphanilic acid in acidic medium followed by its coupling with indoxyl sulfate (indican), which gives an azo product and extraction of the colored product using the cloud point extraction (CPE) technique. The optimal extraction and reaction conditions (e.g., acid and reagent concentrations, effect of time) were studied, and the analytical characteristics of the method (e.g., limit of detection, linear range, preconcentration factor) were obtained. Linear response was achieved within 0.9–44 μg/mL and the detection limit was estimated as 0.6 μg/mL. The inter-day and intraday relative standard deviations were in the ranges 1.2–1.3% and 1.6–1.8% for indican. The method was applied to the determination of indican in human spiked urine samples; Recoveries within 96–99% were obtained.  相似文献   

12.
Determination of estrogens in water by HPLC-UV using cloud point extraction   总被引:1,自引:0,他引:1  
Wang L  Cai YQ  He B  Yuan CG  Shen DZ  Shao J  Jiang GB 《Talanta》2006,70(1):47-51
A method based on cloud point extraction was developed to determine four kinds of estrogens: estriol (E3), estradiol (E2), estrone (E1), and progesterone (P) in water by high performance liquid chromatography separation and ultraviolet detection (HPLC-UV). The non-ionic surfactant Triton X-114 was chosen as extractant solvent. The parameters affecting extraction efficiency, such as concentrations of Triton X-114 and Na2SO4, equilibration temperature, equilibration time and centrifugation time were evaluated and optimized. Under the optimum conditions, preconcentration factors of 99 for E3, 73 for E2, 152 for E1 and 86 for P were obtained for 10 mL water sample. The detection of limitation was 0.23 ng mL−1 for E3, 0.32 ng mL−1 for E2, 0.25 ng mL−1 for E1 and 5.0 ng mL−1 for P. The proposed method was successfully applied to the determination of trace amount of estrogens in wastewater treatment plant (WWTP) effluent water and exposure water with 10 ng mL−1 E2 for toxicological study in our lab. For the case of WWTP effluent water samples, no estrogen was found. The accuracy of the proposed method was tested by recovery measurements of spiked samples and good recoveries of 81.2-99.5% were obtained.  相似文献   

13.
Recently, cloud point extraction (CPE) has been an attractive subject as an alternative to liquid–liquid extraction. The technique is based on the property of most non-ionic surfactants in aqueous solutions to form micelles and become turbid when heated to the cloud point temperature. This review covers a selection of the literature published on applications of CPE in determination of metal ions over the period between 2004 and 2008.  相似文献   

14.
N. Shokoufi 《Talanta》2007,73(4):662-667
A new combination method, employing thermal lens spectrometry (TLS) after cloud point extraction (CPE), has been developed for the preconcentration and determination of rhodium. TLS and CPE methods have good matching conditions for the combination because TLS is a suitable method for the analysis of low volume samples obtained after CPE.Rhodium was complexed with 1-(2-pyridylazo)-2-naphthol (PAN) as a complexing agent in an aqueous medium and concentrated by octylphenoxypolyethoxyethanol (Triton X-114) as a surfactant. After the phase separation at 50 °C based on the cloud point extraction of the mixture, the surfactant-rich phase was dried and the remaining phase was dissolved using 20 μL of carbon tetrachloride. The obtained solution was introduced into a quartz micro cell and the analyte was determined by laser induced-thermal lens spectrometry (LI-TLS). The single laser TLS was used as a sensitive method for the determination of Rhodium-PAN complex in 20 μL of the sample. Under optimum conditions, the analytical curve was linear for the concentration range of 0.5-50 ng mL−1 and the detection limit was 0.06 ng mL−1. The enhancement factor of 450 was achieved for 10 mL samples containing the analyte and relative standard deviations were lower than 5%. The developed method was successfully applied to the extraction and determination of rhodium in water samples.  相似文献   

15.
A novel and sensitive cloud point extraction procedure for the determination of trace amounts of malachite green by spectrophotometry was developed. Malachite green was extracted at pH 2.5 mediated by micelles of nonionic surfactant Triton X-100. The extracted surfactant-rich phase was diluted with ethanol and its absorbance was measured at 630 nm. The effect of different variables such as pH, Triton X-100 concentration, cloud point temperature and time and diverse ions was investigated and optimum conditions were established. The calibration graph was linear in the range of 4-500 ng mL−1 of malachite green in the initial solution with r = 0.9996 (n = 10). Detection limit based on three times the standard deviation of the blank (3Sb) was 1.2 ng mL−1 and the relative standard deviation (R.S.D.) for 20 and 300 ng mL−1 of malachite green was 1.48 and 1.13% (n = 8), respectively. The method was applied to the determination of malachite green in different fish farming and river water samples.  相似文献   

16.
A cloud point extraction (CPE) method has been developed for the preconcentration of trace aluminum prior to its determination by flame atomic absorption spectrometry (FAAS). The CPE method is based on the complex of Al(III) with Xylidyl Blue (XB) and then entrapped in non-ionic surfactant Triton X-114. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of XB and Triton X-114, equilibration temperature and time, were investigated in detail. An enrichment factor of 50 was obtained for the preconcentration of Al(III) with 50 mL solution. Under the optimal conditions, the detection limit of this method for Al(III) is 1.43 μg L− 1, and the relative standard deviation is 2.7% at determination of 100 μg L− 1 Al(III). The proposed method has been applied for determination of trace amount of aluminum in mineral water samples with satisfactory results. Also, the proposed method was applied to the certified reference materials. The results obtained were in good agreement with certified values.  相似文献   

17.
The cloud point of nonionic surfactant polyoxyethylene (23) lauryl ether (Brij-35) was determined in the presence of various inorganic electrolytes. The measurements of cloud point (CP) were carried out with UV-vis spectrophotometer instead of visual observation. CP of Brij-35 could not be measured directly because its CP is more than 100 °C. Therefore, CP values of Brij-35 were lowered by the addition of electrolytes. In this study, NaF, NaCl, NaBr, KNO3, K2CO3, K3PO4, Li2SO4, Na2SO4, K2SO4, (NH4)2SO4, CuSO4, ZnSO4, CoSO4 were used as electrolytes. Linear lines which were drawn with CP values were extrapolated to zero electrolyte concentration. The real CP value of Brij-35 which is merely listed as >100 °C in the literature was found as 118.5 ± 0.5 °C for all samples. Furthermore, the effects of the nature of the cation and the anion and the valencies of the cations on CP were reported and the rate of decrease in CP with concentration is discussed.  相似文献   

18.
建立了以四甲基联苯胺(TMB)为络合剂,非离子表面活性剂Triton-114为萃取剂的浊点萃取-紫外可见分光光度法测定痕量金的方法。考察了溶液的pH、络合剂和表面活性剂浓度、平衡温度和时间等条件对浊点萃取的影响。在最优条件下,该方法对金的富集倍数为12倍,线性范围为0~0.5μg/mL,检出限(3σ)为8.6ng/mL,相对标准偏差RSD为2.3%~3.6%(n=6),回收率在97%~102%之间。方法已用于工业废水中痕量金的测定。  相似文献   

19.
Persistent organic pollutants (POPs) are recognized as a class of poisonous compounds which pose risks of causing adverse effects to human health and the environment. Thus, it is very important to detect POPs in environmental and biological samples. The identification and determination of very low levels of POPs in complex matrices is extremely difficult. Recently a promising environmentally benign extraction and preconcentration methodology based on cloud point extraction (CPE) has emerged as an efficient sample pretreatment technique for the determination of trace/ultra-trace POPs in complex matrices. The purpose of this paper is to review the past and latest use of CPE for preconcentrating POPs and its coupling to different contemporary instrumental methods of analysis. First, the comparison of various extraction techniques for POPs is described. Next, the general concept, influence factors and other methods associated with CPE technique are outlined and described. Last, the hyphenations of CPE to various instrumental methods for their determination are summarized and discussed.  相似文献   

20.
A new cloud point extraction (CPE) method for ergotamine analysis using fluorimetric detection is described. Ergotamine from an aqueous solution was preconcentrated into a smaller surfactant-rich phase using nonionic surfactant polyoxyethylene(7.5)nonylphenylether (PONPE 7.5). Differently from the conventional CPE procedure in which the resulting surfactant-rich phase is diluted by a fluidificant before its analysis, in this method the fluorescence measurements were carried out directly onto the undiluted surfactant-rich phase. The high viscosity provided by the undiluted surfactant rich phase greatly improved the fluorescence emission of ergotamine, leading to a total enhancement factor of 1325. This spectral advantage plus the preconcentration factor achieved, contributed to the method sensitivity allowing the ergotamine determination at trace level concentration. Under optimal experimental conditions, a linear calibration curve was obtained from 3.81 × 10−7 to 1.10 μg mL−1, with detection and quantification limits of 0.11 and 0.38 pg mL−1, respectively. The accuracy and versatility of the present methodology were proved by analyzing ergotamine in real samples of different natures such as pharmaceuticals, urine and saliva.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号