首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
The impedance of the middle-ear air space was measured on three human cadaver ears with complete mastoid air-cell systems. Below 500 Hz, the impedance is approximately compliance-like, and at higher frequencies (500-6000 Hz) the impedance magnitude has several (five to nine) extrema. Mechanisms for these extrema are identified and described through circuit models of the middle-ear air space. The measurements demonstrate that the middle-ear air space impedance can affect the middle-ear impedance at the tympanic membrane by as much as 10 dB at frequencies greater than 1000 Hz. Thus, variations in the middle-ear air space impedance that result from variations in anatomy of the middle-ear air space can contribute to inter-ear variations in both impedance measurements and otoacoustic emissions, when measured at the tympanic membrane.  相似文献   

2.
Bone conduction (BC) relative to air conduction (AC) sound field sensitivity is here defined as the perceived difference between a sound field transmitted to the ear by BC and by AC. Previous investigations of BC-AC sound field sensitivity have used different estimation methods and report estimates that vary by up to 20 dB at some frequencies. In this study, the BC-AC sound field sensitivity was investigated by hearing threshold shifts, ear canal sound pressure measurements, and skull bone vibrations measured with an accelerometer. The vibration measurement produced valid estimates at 400 Hz and below, the threshold shifts produced valid estimates at 500 Hz and above, while the ear canal sound pressure measurements were found erroneous for estimating the BC-AC sound field sensitivity. The BC-AC sound field sensitivity is proposed, by combining the present result with others, as frequency independent at 50 to 60 dB at frequencies up to 900 Hz. At higher frequencies, it is frequency dependent with minima of 40 to 50 dB at 2 and 8 kHz, and a maximum of 50 to 60 dB at 4 kHz. The BC-AC sound field sensitivity is the theoretical limit of maximum attenuation achievable with ordinary hearing protection devices.  相似文献   

3.
In a previous paper (Arnold and Burkard, 1998) a dichotic f2-f1 difference tone (DT) auditory evoked potential from the chinchilla inferior colliculus (IC) was measured while presenting f1 (2000 Hz) to one ear and f2 (2100 Hz) to the other ear. This measurement paradigm could be used as a means to study binaural processing in an unanesthetized animal model. However, it is possible that this response is actually generated peripherally, as a result of acoustic crossover. The purpose of the present set of experiments was to investigate whether the dichotic DT is a true binaural phenomenon. Recordings were made from chronically implanted IC electrodes in unanesthetized, monaural chinchillas (left cochlea destroyed). In experiment 1, interaural attenuation (IA) was measured in two ways. First, IA was measured by comparing IC evoked potential thresholds obtained when stimulating the normal right ear and the dead left ear, using tone bursts (0.5-8 kHz). Mean values of interaural attenuation ranged from 50-65 dB across frequency (55 dB at 2000 Hz). Next, the DT was measured monaurally using f1 = 2000 and f2 = 2100 (L1 = L2). By comparing the mean DT input/output functions for monaural stimulation of the right and left ears, a mean value of IA for the tonal pair was estimated (approximately 69 dB). In experiment 2, the DT was measured with right monaural stimulation, while varying the relative levels of the primaries. A small DT could be seen with primary levels up to 30 dB apart, but not for greater level differences. Differences substantially greater than 30 dB would be expected in the crossover situation based upon IA. In experiment 3, the stimuli were presented dichotically (f1 to right ear, f2 to left ear and vice versa, L1 = L2) to determine whether acoustic crosstalk to the normal right ear would generate a DT. No DT was reliably observed in this condition. Taken together, these results suggest that the dichotic DT is a true binaural phenomenon, and not simply attributable to acoustic crossover.  相似文献   

4.
In clinical measurements of hearing sensitivity, a given earphone is assumed to produce essentially the same sound-pressure level in all ears. However, recent measurements [Voss et al., Ear and Hearing (in press)] show that with some middle-ear pathologies, ear-canal sound pressures can deviate by as much as 35 dB from the normal-ear value; the deviations depend on the earphone, the middle-ear pathology, and frequency. These pressure variations cause errors in the results of hearing tests. Models developed here identify acoustic mechanisms that cause pressure variations in certain pathological conditions. The models combine measurement-based Thévenin equivalents for insert and supra-aural earphones with lumped-element models for both the normal ear and ears with pathologies that alter the ear's impedance (mastoid bowl, tympanostomy tube, tympanic-membrane perforation, and a "high-impedance" ear). Comparison of the earphones' Thévenin impedances to the ear's input impedance with these middle-ear conditions shows that neither class of earphone acts as an ideal pressure source; with some middle-ear pathologies, the ear's input impedance deviates substantially from normal and thereby causes abnormal ear-canal pressure levels. In general, for the three conditions that make the ear's impedance magnitude lower than normal, the model predicts a reduced ear-canal pressure (as much as 35 dB), with a greater pressure reduction with an insert earphone than with a supra-aural earphone. In contrast, the model predicts that ear-canal pressure levels increase only a few dB when the ear has an increased impedance magnitude; the compliance of the air-space between the tympanic membrane and the earphone determines an upper limit on the effect of the middle-ear's impedance increase. Acoustic leaks at the earphone-to-ear connection can also cause uncontrolled pressure variations during hearing tests. From measurements at the supra-aural earphone-to-ear connection, we conclude that it is unusual for the connection between the earphone cushion and the pinna to seal effectively for frequencies below 250 Hz. The models developed here explain the measured pressure variations with several pathologic ears. Understanding these mechanisms should inform the design of more accurate audiometric systems which might include a microphone that monitors the ear-canal pressure and corrects deviations from normal.  相似文献   

5.
Approaches were examined for reducing acoustic noise levels heard by subjects during functional magnetic resonance imaging (fMRI), a technique for localizing brain activation in humans. Specifically, it was examined whether a device for isolating the head and ear canal from sound (a "helmet") could add to the isolation provided by conventional hearing protection devices (i.e., earmuffs and earplugs). Both subjective attenuation (the difference in hearing threshold with versus without isolation devices in place) and objective attenuation (difference in ear-canal sound pressure) were measured. In the frequency range of the most intense fMRI noise (1-1.4 kHz), a helmet, earmuffs, and earplugs used together attenuated perceived sound by 55-63 dB, whereas the attenuation provided by the conventional devices alone was substantially less: 30-37 dB for earmuffs, 25-28 dB for earplugs, and 39-41 dB for earmuffs and earplugs used together. The data enabled the clarification of the relative importance of ear canal, head, and body conduction routes to the cochlea under different conditions: At low frequencies (< or =500 Hz), the ear canal was the dominant route of sound conduction to the cochlea for all of the device combinations considered. At higher frequencies (>500 Hz), the ear canal was the dominant route when either earmuffs or earplugs were worn. However, the dominant route of sound conduction was through the head when both earmuffs and earplugs were worn, through both ear canal and body when a helmet and earmuffs were worn, and through the body when a helmet, earmuffs, and earplugs were worn. It is estimated that a helmet, earmuffs, and earplugs together will reduce the most intense fMRI noise levels experienced by a subject to 60-65 dB SPL. Even greater reductions in noise should be achievable by isolating the body from the surrounding noise field.  相似文献   

6.
The ear canal sound pressure and the malleus umbo velocity with bone conduction (BC) stimulation were measured in nine ears from five cadaver heads in the frequency range 0.1 to 10 kHz. The measurements were conducted with both open and occluded ear canals, before and after resection of the lower jaw, in a canal with the cartilage and soft tissues removed, and with the tympanic membrane (TM) removed. The sound pressure was about 10 dB greater in an intact ear canal than when the cartilage part of the canal had been removed. The occlusion effect was close to 20 dB for the low frequencies in an intact ear canal; this effect diminished with sectioning of the canal. At higher frequencies, the resonance properties of the ear canal determined the effect of occluding the ear canal. Sectioning of the lower jaw did not significantly alter the sound pressure in the ear canal. The sound radiated from the TM into the ear canal was investigated in four temporal bone specimens; this sound is significantly lower than the sound pressure in an intact ear canal with BC stimulation. The malleus umbo velocity with air conduction stimulation was investigated in nine temporal bone specimens and compared with the umbo velocity obtained with BC stimulation in the cadaver heads. The results show that for a normal open ear canal, the sound pressure in the ear canal with BC stimulation is not significant for BC hearing. At threshold levels and for frequencies below 2 kHz, the sound in the ear canal caused by BC stimulation is about 10 dB lower than air conduction hearing thresholds; this difference increases at higher frequencies. However, with the ear canal occluded, BC hearing is dominated by the sound pressure in the outer ear canal for frequencies between 0.4 and 1.2 kHz.  相似文献   

7.
针对管道内低频噪声难以抑制的问题,本文基于亥姆霍兹共振腔(HR)阵列吸声板和穿孔管消声器组合,设计了一种复合式宽带消声器。首先利用有限元法仿真分析传统穿孔管消声器,发现中低频消声能力较差,通过嵌入HR阵列吸声板吸收中低频噪声。采用仿真与实验的方式研究吸声板的声学性能:在400-1000 Hz频段内的平均吸声系数达到了0.88。然后对复合式消声器进行数值模拟及3D打印阻抗管实验测试对比:复合式消声器在400-1718Hz频率范围内的平均传递损失为18.15 dB ,最终实现了管道内全频带噪声有效控制。  相似文献   

8.
A new method to reduce traffic noise by means of an ‘invisible’ wall has been investigated both theoretically and experimentally. A formula was derived for the frequency dependent impedance of an infinite structure of parallel ribs on an impedance boundary. From the definition of surface waves it followed that these waves can only exist for certain combinations of frequencies, heights of ribs and phases of the complex reflection coefficient of the underlying surface. Upon making this surface softer, more low frequency sound is absorbed. Outdoor experiments above an array of 16 or 21 low brick walls showed a considerable absorption of sound. Attenuations occurred up to 20 dB in the one-third octave bands from 125 to 400 Hz and amplifications up to 12 dB in the range of 400–1000 Hz. It was possible to explain these measurements qualitatively by the theory of surface waves. The wall structure caused an insertion loss of approximately 4 dB(A) in the total sound pressure level of the A-weighted one-third octave bands from 100 to 12,500 Hz.  相似文献   

9.
The noise-excluding properties of a standard supra-aural audiometric earphone, a widely used circumaural-supra-aural combination, and an insert earphone sealed to the ear with a vinyl foam eartip were measured in a diffuse-field room complying with ANSI S12.6-1984. Data on attenuation were obtained monaurally with the nontest ear plugged and muffed. Results for the supra-aural earphones generally agreed well with previously reported measurements. A broadband masking noise was used to directly test the ANSI S3.1-1977 permissible background noise levels for measuring to audiometric zero using standard audiometric earphones. This "ANSI noise" raised the average thresholds of 15 normal-hearing test subjects by 3 to 5 dB at the octave frequencies from 500 to 4000 Hz. With a noise conforming to the less stringent OSHA-1983 regulation, average thresholds were elevated 9 to 17 dB. An "ENT office noise" with an overall sound level of 54 dBA raised average thresholds even further, by as much as 29 dB at 500 Hz. Use of the circumaural system in the office noise limited the threshold elevation to 11, 5, 2, and 0 dB at the four octave frequencies tested. With the fully ("deeply") inserted foam eartips, the threshold elevation in the simulated office noise was 2 dB or less at all test frequencies. Actual threshold elevations agreed closely with predictions based on a critical ratio calculation utilizing measured sound field noise levels and measured earphone attenuation values.  相似文献   

10.
Input-output (I/O) functions for stimulus-frequency (SFOAE) and distortion-product (DPOAE) otoacoustic emissions were recorded in 30 normal-hearing adult ears using a nonlinear residual method. SFOAEs were recorded at half octaves from 500-8000 Hz in an L1=L2 paradigm with L2=0 to 85 dB SPL, and in a paradigm with L1 fixed and L2 varied. DPOAEs were elicited with primary levels of Kummer et al. [J. Acoust. Soc. Am. 103, 3431-3444 (1998)] at f2 frequencies of 2000 and 4000 Hz. Interpretable SFOAE responses were obtained from 1000-6000 Hz in the equal-level paradigm. SFOAE levels were larger than DPOAEs levels, signal-to-noise ratios were smaller, and I/O functions were less compressive. A two-slope model of SFOAE I/O functions predicted the low-level round-trip attenuation, the breakpoint between linearity and compression, and compressive slope. In ear but not coupler recordings, the noise at the SFOAE frequency increased with increasing level (above 60 dB SPL), whereas noise at adjacent frequencies did not. This suggests the existence of a source of signal-dependent noise producing cochlear variability, which is predicted to influence basilar-membrane motion and neural responses. A repeatable pattern of notched SFOAE I/O functions was present in some ears, and explained using a two-source mechanism of SFOAE generation.  相似文献   

11.
12.
The responses of the malleus and the stapes to sinusoidal acoustic stimulation have been measured in the middle ears of anesthetized chinchillas using the M?ssbauer technique. With "intact" bullas (i.e., closed except for venting via capillary tubing), the vibrations of the tip of the malleus reach a maximal peak velocity of about 2 mm/s in responses to 100-dB SPL tones in the frequency range 500-6000 Hz; vibration velocity diminishes toward lower frequencies with a slope of about 6 dB/oct. Opening the bulla widely increases the responses to low-frequency stimuli by as much as 16 dB. At low frequencies, malleus response sensitivity with either open or intact bullas far exceeds all previous measurements in cats and matches or exceeds such measurements in guinea pigs. Whether measured in open or intact bullas, phase-versus-frequency curves closely approximate those predicted from the magnitude-versus-frequency curves by minimum phase theory. The stapes responses are similar to those of the malleus, except that stapes response magnitude is lower, on the average, by 7.5 dB at frequencies below 2 kHz and 10.7 dB at 2 kHz and above. Comparison of the responses of the middle ear with those of the basilar membrane at a site 3.5 mm from the stapes indicates that, at frequencies below 150 Hz, the basilar membrane displacement is proportional to stapes acceleration. At frequencies between 150 and 2000 Hz, basilar membrane displacement is proportional to stapes velocity.  相似文献   

13.
A piezoelectric (PZE) vibrator was used to mechanically drive the columella footplate and stimulate the cochlea of chicken embryos and hatchlings. Our objectives were to characterize the motion of the PZE driver and determine the relationship between columella footplate motion (displacement/ velocity) and the cochlear microphonic recorded from the recessus scala tympani (CMrst). At each frequency, displacement of the PZE driver probe tip was linearly related to the applied voltage over a wide range of attenuation levels (-60 to -20 dBre:50 Vp-p). The mean displacement across frequencies (100-4000 Hz) was 0.221+/-0.042 micromp-p for a constant applied voltage level of -20 dBre:50 Vp-p. Displacement was within 1.5 dB of the mean for this stimulus level at all frequencies except for 4000 Hz, where it was approximately 3 dB higher (p < 0.01). CMrst amplitudes in hatchlings were larger than amplitudes in embryos (p=0.003). For a given frequency, CM was linearly related to footplate displacement and velocity at both ages. The transform ratio of CMrst/A (CM amplitude/displacement) increased at approximately 6 dB/octave at frequencies between 100 and 1000 Hz in hatchlings suggesting that cochlear impedance (Zc) was resistive at these frequencies. In a large fraction of the embryos, Zc exhibited reactive behavior.  相似文献   

14.
为研究烟火药水下燃烧声辐射机理,采用烟火药和压缩氮气喷射声源对比的方法,利用水声测试系统,通过实验研究不同体积流量下两种声源装置的声辐射规律。结果表明,烟火药水下燃烧声源与压缩氮气声源的声辐射特征相似,辐射频率主要集中在0~1000 Hz内,峰值频率均位于100 Hz附近,总声压级、峰值声压级均随着气体流量增加而增强。当气体流量从60 ml/s增加到84 ml/s时,烟火药峰值声压级由155 d B增加到163 d B,0~1000 Hz内总声压级由159 d B增加到165 d B;当喷气流量从70 ml/s增加到141 ml/s时,压缩氮气源峰值声压级由136 d B增加到139 d B,0~1000 Hz内总声压级由144 d B增加到147 d B。当气体流量相近时,烟火药相比压缩氮气声压级相差显著,其声压级均高于同频率下压缩氮气源,两者的峰值声压级分别为157 d B、139 d B,0~1000 Hz内总声压级分别为160 d B、147 d B。  相似文献   

15.
The relation between the monaural critical band and binaural analysis was examined using an NoSm MLD paradigm, in order to resolve ambiguities about the width of the masking spectrum important for binaural detection. A 500-Hz pure-tone signal was presented with a 600-Hz-wide band of masking noise to the signal ear. Bands of noise ranging in width from 25 to 600 Hz, or noise notches (imposed on a 600-Hz-wide band centered on the signal frequency) ranging in width from 0 to 600 Hz were presented to the nonsignal ear. All noise bands and notches were centered on 500 Hz, the frequency of the signal. The effects of varying bandwidth were radically different from those of varying notchwidth: the MLD changed from zero to approximately 8 dB over a bandwidth range of 400 Hz; for notchwidths, however, the MLD changed 8 dB over a range of only 50 Hz. The results support an interpretation that the fine frequency selectivity of monaural analysis is preserved in peripheral binaural interaction, but that a relatively wide frequency range of critical bands is scanned at a later stage of binaural processing. It was suggested that the wide spectral range of binaural analysis may provide a background against which binaural differences due to the signal are detected.  相似文献   

16.
Artificial ear is being used to evaluate the acoustic response and the sound quality of the mobile telephony devices, which simulates the practical listening condition of the outer ears. In this paper, a method to estimate the coupled acoustic response of the device with an artificial ear is studied to be effectively used in the design. To this end, an equivalent circuit model of the total receiver system including all accessory elements is established. Acoustic impedance of artificial ear, which is essential in the equivalent model, is directly measured by using three microphones arranged in tandem on the duct wall connected to the artificial ear. Input impedances of two artificial ears, Type 3.3 and 3.4, which are currently employed as the standard devices, are measured. The measured data is incorporated into the model to predict the acoustic response. To validate the proposed model using the measured impedance, the measured acoustic responses of two simulation systems including mobile phone and artificial ear are compared with the predicted ones. A reasonably good agreement between measurement and prediction is observed, and their difference is less than 4.5 dB at the narrow communication band for a mobile phone (f < 3.4 kHz). It is also found that the input impedance of Type 3.3 ear is more robust to the change of measuring condition than Type 3.4 ear.  相似文献   

17.
Methods of measuring the attenuation of hearing protection devices   总被引:1,自引:0,他引:1  
The published literature describing three real-ear-attenuation-at-threshold (REAT), nine above-threshold, and four objective methods of measuring hearing protector attenuation is reviewed and analyzed with regard to the accuracy, practicality, and applicability of the various techniques. The analysis indicates that the REAT method is one of the most accurate available techniques since it assesses all of the sound paths to the occluded ear and, depending upon the experimenter's intention, can reflect actual in-use attenuation as well. An artifact in the REAT paradigm is that masking in the occluded ear due to physiological noise can spuriously increase low-frequency (less than or equal to 500 Hz) attenuation, although the error never exceeds approximately 5 dB, regardless of the device, except below 125 Hz. Since the preponderance of available data indicates that attenuation is independent of sound level for intentionally linear protectors, the use of above-threshold procedures to evaluate attenuation is not a necessity. An exception exists in the case of impulsive noises, for which the existing data are not unequivocal with regard to hearing protector response characteristics. Two of the objective methods (acoustical test fixture and microphone in real ear) are considerable time savers. All objective procedures are lacking in their ability to accurately determine the importance of the flanking bone-conduction paths, although some authors have incorporated this feature as a post-measurement correction. The microphone in real-ear approach is suggested to be one of the most promising for future standardization efforts and research purposes, and the acoustical test fixture technique is recommended (with certain reservations) for quality control and buyer acceptance testing.  相似文献   

18.
In this article the results are reported of a study to measure the intensity of the vocal displays of a population of American alligators (Alligator mississippiensis). It was found that the dominant frequencies in air range between 20 and 250 Hz with a source sound pressure level (SPL) of 91-94 dB at 1 m. The active space for the air-borne component is defined by the background and was estimated to be in a range up to 159 m in the 125-200 Hz band. For the water-borne component the dominant frequency range was 20-100 Hz with a source SPL of 121-125 dB at 1 m. The active space in water is defined by hearing thresholds and was estimated to range up to 1.5 km in the 63-100 Hz band. In the lowest frequency bands, i.e., 16-50 Hz, the estimated active space for otolith detection of near-field particle motion in water ranged to 80 m, which compared significantly with far-field detection for these frequencies. It is suggested that alligator vocal communication may involve two distinct sensory mechanisms which may subserve the functions of scene analysis and reproduction, respectively.  相似文献   

19.
针对深水、低频、宽带换能器的技术需求,结合Janus-Helmholtz换能器的结构特点和铁镓单晶材料低场应变大及机械强度高的特性,提出了铁镓单晶Janus-Helmholtz换能器设计方案。采用永磁偏磁场和环形闭合磁路,建立了一系列铁镓单晶磁致伸缩换能器理论分析模型,包括对磁致伸缩材料参数进行线性化处理,设计了换能器最佳工作点,结合静态磁场和动态磁场分布情况分段细化换能器驱动等效参数,以及利用全阻抗模型通过电感损耗等效计算换能器静态阻抗,然后通过二维有限元分析等效模型,优化分析了换能器的结构参数与电声性能。最后制作了换能器样机,并进行了测试与分析。对比仿真和测试结果表明:全阻抗模型得到的阻抗曲线与样机测试结果相一致,有限元等效模型计算的发送电流响应与样机测试结果良好吻合。换能器样机水中谐振基频为1000 Hz,谐振频率下发送电流响应176.4 dB;在875~2300 Hz频率范围内,发送电流响应起伏不大于6 dB;增加驱动电流有效值到16.2 A,最大声源级可以达到196.2 dB。  相似文献   

20.
高效共振混合机工作频率为60 Hz,且系统处于共振,产生较大低频噪声。针对振动机械产生的有害噪声,分析了高效共振混合机低频高加速度共振混合过程的特点,得到了60 Hz低频声波穿透力强的特点,相比传统的以吸声材料构建的50~100 mm厚度、隔声效果小于10 dB的隔声罩,分析了薄膜型声学超材料在低频减振降噪中的隔声特性。通过多物理场仿真分析,60 Hz时隔声量为31.4 dB,确定了硅橡胶弹性薄膜的预应力和质量块的面密度;采用3D打印机快速成型技术,构建了隔声实验装置,分析了独立隔声单元、面密度、薄膜尺寸等隔声特性规律。基于人耳在实际环境中感受到的噪声强度,提出了噪声衰减量和插入损失的分析方法,在距离声源380 mm和1000 mm的位置,60 Hz时隔声量分别为27 dB和38 dB。研究成果丰富了低频隔声特性理论,为薄膜型声学超材料的工程设计和优化提供了技术支撑。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号