 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive method has been developed for the detection and quantitative determination of thiodiglycol in blood, plasma and urine. Samples were extracted from Clin Elut columns and cleaned up on C18 Sep-Pak cartridges (blood, plasma) or Florisil Sep-Pak cartridges (urine). Tetradeuterothiodiglycol was added to the sample prior to extraction as internal standard. Thiodiglycol was converted to its bis-(pentafluorobenzoate) derivative and analysed by capillary gas chromatography-electron-capture negative-ion chemical ionisation mass spectrometry using selected ion monitoring. Levels of thiodiglycol down to 1 ng/ml (1 ppb) could be detected in 1-ml spiked blood and urine samples; calibration curves were linear over the range 5- or 10-100 ng/ml. Blood and urine samples from a number of control subjects were analysed for background levels of thiodiglycol. Concentrations up to 16 ng/ml were found in blood, but urine levels were below 1 ng/ml.  相似文献   

2.
A high-performance liquid chromatographic method for the measurement of bumetanide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol-water-glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5-2000 ng/ml.  相似文献   

3.
A simple and sensitive high-performance liquid chromatographic assay was developed for the quantitative determination of major erythromycin components and their potential metabolites or degradation products in plasma and urine. An ether extract of alkalized plasma sample was chromatographed on a reversed-phase column and the components in the column effluent were monitored by an electrochemical detector. The recovery of the drug from extraction was virtually 100%. The detection limits for erythromycin A in plasma were 5-10 ng/ml and 30 ng/ml using 1 and 0.2 ml of sample, respectively. For urine samples, a simple one-step deproteinization with two volumes of acetonitrile was satisfactory for analysis. The method has been evaluated in plasma and urine from dogs receiving oral or intravenous erythromycin A. The standard curves for potential metabolites or degradation products were not constructed due to the lack of sufficient samples.  相似文献   

4.
A selective and sensitive high-performance liquid chromatographic method for determination of intact glibenclamide in human plasma or urine has been developed. With glibornuride as internal standard, acid-buffered plasma or urine was extracted with benzene. The organic layer was evaporated and the residue was dissolved in equilibrated mobile phase (acetonitrile-phosphate buffer 0.01 M pH 3.5, 50:50). An aliquot of 20 microliters was chromatographed on a Spherisorb ODS reversed-phase column, and quantitation was achieved by monitoring the ultraviolet absorbance at 225 nm. The response was linear (0-1000 ng/ml) and the detection limit was 5-10 ng/ml in plasma or urine. The within-assay variation was less than or equal to 10%. No interferences from metabolites or endogenous constituents could be noted. The utility of the method was demonstrated by analysing glibenclamide in samples from diabetic subjects on therapeutic doses of the drug.  相似文献   

5.
A relatively simple, sensitive and rapid high-performance liquid chromatographic method is described for measuring the anticancer drug 5-fluorouracil (5-FU) in human plasma and urine. The procedure includes liquid-liquid extraction using ethyl acetate-methanol (95:5) and preparative column chromatography to separate 5-FU from constituents normally occurring in these biological samples. The columns contained a specially modified form of diatomaceous earth, which requires no pre-conditioning washes. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70 mm x 4.6 mm I.D.) with a mobile phase of water-methanol (95:5) and ultraviolet detection (268 nm). The overall recovery from plasma and urine was 91 and 94%, respectively, at the concentration of 50 ng/ml. The determination limit of the assay for 5-FU was 10 ng/ml of plasma and urine. Concentrations of 5-FU between 10 and 500 ng/ml were measured in plasma and urine with a relative standard deviation of 6.8%. In order to evaluate the procedure, plasma and urine samples from three patients treated with 5-FU by continuous intravenous perfusion, were investigated.  相似文献   

6.
A sensitive and reproducible high-performance liquid chromatographic method was developed to assay ampherotericin B in plasma, blood, urine and various tissue samples. Amphotericin B was isolated from each sample matrix by solid-phase extraction (Bond-Elut). The eluate from Bond-Elut containing amphotericin B was injected onto a reversed-phase C18 column (Waters, mu Bondpak, 10 microns, 300 mm x 3.9 mm I.D.) with a mobile phase of 45% acetonitrile in 2.5 mM Na2EDTA at 1 ml/min. Detection of amphotericin B was by ultraviolet absorption at 382 nm. Blood and tissues were homogenized and extracted with methanol prior to Bond-Elut extraction. The extraction efficiencies of amphotericin B from plasma, blood and tissues were approximately 90, 70 and 75%, respectively. The sensitivity of the assay was less than or equal to 5 ng/ml for plasma, less than or equal to 25 ng/ml for blood, 2.5 ng/ml for urine and 50 ng/g for tissues. The linearity of the assay method was up to 2.5 micrograms/ml for plasma, 5 micrograms/ml for blood, 500 ng/ml for urine and 500 micrograms/g for tissues. The assay was reproducible with an intra-day coefficient of variation (C.V., n = 3) of less than 5% in general for plasma, blood and tissues. The inter-day C.V. of the assay was less than 5% for plasma (n = 5), less than 10% for blood (n = 4) and less than 5% for tissues (n = 3). The overall variability in the urine assay was generally less than 10%. This method has demonstrated significant improvement in the sensitivity and reproducibility in assaying amphotericin B in plasma and especially in blood, urine and tissues. We have employed this assay to compare the pharmacokinetic and tissue distribution profiles of amphotericin B in rats and dogs following administration of Fungizone and ABCD (amphotericin B-cholesteryl sulfate colloidal dispersion), a lipid-based dosage form. In addition, the assay method for plasma and urine samples can also be applied to pharmacokinetics studies of amphotericin B in man.  相似文献   

7.
A sensitive and selective method for the determination of the pyridinium metabolite (HPP+) derived from the antipsychotic drug haloperidol (HP) in brain tissue, plasma and urine using high-performance liquid chromatography with fluorescence detection is described. The HPP+ present in biological samples was extracted using a Sep-Pak C18 cartridge. Recoveries of HPP+ ranged from 78 to 90%. Final separation and quantitative estimations of HPP+ were achieved on a C18 reversed-phase column employing a mobile phase of acetonitrile-30 mM ammonium acetate (40:60, v/v) containing 10 mM triethylamine and adjusted to pH 3 with trifluoroacetic acid. The fluorescence detection utilized an excitation wavelength of 304 nm and an emission wavelength of 374 nm. Standard curves were linear in the range of 2.5-100 ng/ml for brain tissue homogenate and plasma samples and 10-500 ng/ml for urine samples. The detection limit of HPP+ was about 1 ng/ml in all biological samples. The concentrations of HPP+ in brain tissue, plasma and urine from HP-treated rats were determined using this method.  相似文献   

8.
A rapid, sensitive and robust assay procedure using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) for the determination of famotidine in human plasma and urine is described. Famotidine and the internal standard were isolated from plasma samples by cation-exchange solid-phase extraction with benzenesulfonic acid (SCX) cartridges. The urine assay used direct injection of a diluted urine sample. The chromatographic separation was accomplished by using a BDS Hypersil silica column with a mobile phase of acetonitrile-water containing trifluoroacetic acid. The MS/MS detection of the analytes was set in the positive ionization mode using electrospray ionization for sample introduction. The analyte and internal standard precursor-product ion combinations were monitored in the multiple-reaction monitoring mode. Assay calibration curves were linear in the concentration range 0.5--500 ng ml(-1) and 0.05--50 microg ml(-1) in plasma and urine, respectively. For the plasma assay, a 100 microl sample aliquot was subjected to extraction. To perform the urine assay, a 50 microl sample aliquot was used. The intra-day relative standard deviations at all concentration levels were <10%. The inter-day consistency was assessed by running quality control samples during each daily run. The limit of quantification was 0.5 ng ml(-1) in plasma and 0.05 microg ml(-1) in urine. The methods were utilized to support clinical pharmacokinetic studies in infants aged 0-12 months.  相似文献   

9.
Abstract

A high-performance liquid chromatographic method for the analyses of ciprofloxacin (BAY o 9867) (1-cyclopropyl-6-fluoro-1,4-dihydro-4-oxo-7-(1-piperazinyl)-3-quinoline carboxylic acid hydrochloride) in human serum, plasma and urine samples is described. Diluted serum, plasma, and urine samples are injected onto a RP-18 column without prior extraction or clean-up procedure. Ciprofloxacin is separated from the ballast by an eluent consisting of an 0.025M H3PO4 solution adjusted to pH=3 with tetrabutylammonium hydroxide and acetonitrile.

Ciprofloxacin is detected fluorimetrically giving a detection limit of 8ng/ml in plasma and serum and of 50ng/ml in urine. A statistical evaluation of the assay showed acceptable accuracy and precision for 10 to 500ng of BAY o 9867 per ml in serum and plasma and for 50ng to 600ng of BAY o 9867 per ml of diluted urine specimens. This method was used to monitor the concentrations of BAY o 9867 in serum, plasma and urine of volunteers after oral administration of ciprofloxacin.  相似文献   

10.
A sensitive, selective, and rapid high-performance liquid chromatographic procedure was developed for the determination of isoxicam in human plasma and urine. Acidified plasma or urine were extracted with toluene. Portions of the organic extract were evaporated to dryness, the residue dissolved in tetrahydrofuran (plasma) or acetonitrile (urine) and chromatographed on a mu Bondapak C18 column preceded by a 4-5 cm X 2 mm I.D. column packed with Corasil C18. Quantitation was obtained by UV spectrometry at 320 nm. Linearity in plasma ranged from 0.2 to 10 micrograms/ml. Recoveries from plasma samples seeded with 1.8, 4 and 8 micrograms/ml isoxicam were 1.86 +/- 0.077, 4.10 +/- 0.107 and 8.43 +/- 0.154 micrograms/ml with relative standard deviations of 3.3%, 2.5% and 5.4%, respectively. The linearity in urine ranged from 0.125 to 2 micrograms/ml. The precision of the method was 3.3-9.0% relative standard deviation over the linear range.  相似文献   

11.
A high-performance liquid chromatographic (HPLC) method for the determination of a new H2 receptor antagonist, 3-amino-5-[3-[4-(piperidinoindanyloxy)]propylamino] -1-methyl-1H-1,2,4-triazole (I), in human plasma and urine was developed. The method employs liquid-liquid extraction of the analyte and an internal standard and chromatographic separation using an alkylphenyl-bonded HPLC column. The total time of chromatography was less than 10 min. Sensitivity was 10 ng/ml for the plasma analysis and 1 microgram/ml for the analysis of I from urine. The coefficients of variation, based on interpolated concentrations, were less than 10%. The method was used for more than 5000 samples during clinical pharmacokinetic studies.  相似文献   

12.
A rapid, simple and sensitive column-switching high-performance liquid chromatographic procedure for the determination of captopril in plasma and urine had been developed. p-Bromophenacyl bromide was used as a derivatizing reagent to react with captopril to form a product that showed ultraviolet-absorbing properties. For plasma samples the protein was removed with 6% perchloric acid before injection. The urine samples were directly injected into the chromatograph. The column-switching system was equipped with a pre-column (5 cm x 0.5 cm I.D.) packed with muBondapak C18 (37-50 microns) and an analytical column (15 cm x 0.5 cm I.D.) packed with YWG-C18, 10 microns. Impurities were washed from the pre-column with 0.2% acetic acid and the retained substances were eluted into the analytical column with acetonitrile-water-acetic acid (35:65:0.4, v/v). Captopril was detected at 260 nm. The calibration curve was linear in the range 20-1000 ng/ml for plasma and 10-200 micrograms/ml for urine. The recoveries averaged 103.2 and 99.5% for plasma and urine, respectively. The coefficients of variation were all less than 10%.  相似文献   

13.
A highly sensitive and selective quantitative assay for unchanged veralipride has been developed. The compound is extracted from alkalized samples (plasma or urine) with dichloromethane and converted to its trimethylated derivative by reaction with trimethylanilinium hydroxide. The reaction mixture is then chromatographed on a 3% OV-1 column. Trimethylated derivatives of plasma samples were assayed by selected-ion monitoring in the chemical-ionization mode and quantified by comparing the intensity of the quasi-molecular ion m/z 426 (M + H) with the intensity of the corresponding ion from trideuterated internal standard, m/z 429 (M + H). Flame-ionization detection was used for the assay of urine samples. The peak height ratio of trimethylated veralipride over trimethylated sulpiride, the internal standard, was used for quantitation of urine samples. A relative standard deviation of less than 10% was found when quantifying 10 ng/ml veralipride in plasma or 1 microgram/ml in urine.  相似文献   

14.
A high-performance liquid chromatographic method with UV detection (226 nm) for the analysis of sulpiride and sultopride in body fluids has been developed. Plasma, red blood cell (RBC) and urine samples were extracted by chloroform at pH 10. Internal standards were a new substituted benzamide (N-[(ethyl-1-pyrrolidinyl-2)methyl] methoxy-2-ethylsulphonyl-5-benzamide, DAN) for the sulpiride assay and sulpiride for the sultopride assay. The detection limit in plasma and RBC was 10 ng/ml for sulpiride and 15 ng/ml for sultopride. The proposed techniques were selective, reliable and sensitive enough to be used for pharmacokinetic studies and drug monitoring. Some plasma and RBC data from pharmacokinetic studies in healthy volunteers (sulpiride) or patients (sultopride) are presented. Half-lives determined from either plasma or RBC concentrations were similar (7 h for sulpiride and 5 h for sultopride).  相似文献   

15.
Abstract

A liquid chromatographic method is described for the determination of the new fluoroquinolone Ro 23–6240 and its N-demethyl and N-oxide metabolites in plasma and urine. The three substances were extracted from aqueous solution with dichloromethane/isopropanol containing sodium dodecyl sulphate. After evaporation and reconstitution, samples were analysed on a reversed-phase column using ion pair chromatography and fluorescence detection. The limit of quantification was 10–20 ng/ml (RSD 4%) using a 0.5 ml plasma sample, and the inter assay precision was 3–10% over the concentration range 50 ng/ml to 20 μg/ml. Recovery from plasma was 81% (RSD 10%) over the range 10 ng/ml to 5 μg/ml. The method has been applied successfully to the analysis of several thousand samples from human pharmacokinetic studies. Care has to be taken to avoid exposure of samples to direct sunlight, and the use of opaque vessels for sample storage and handling is recommended.  相似文献   

16.
The simultaneous isolation and determination of mitoxantrone (Novantrone) and its two known metabolites (the mono- and dicarboxylic metabolites) were carried out using a high-performance liquid chromatographic (HPLC) system equipped with an automatic pre-column-switching system that permits drug analysis by direct injection of biological samples. Plasma or urine samples were injected directly on to an enrichment pre-column flushed with methanol-water (5:95, v/v) as the mobile phase. The maximum amount of endogenous water-soluble components was removed from biological samples within 9 min. Drugs specifically adsorbed on the pre-column were back-flushed on to an analytical column (Nucleosil C18, 250 X 4.6 mm I.D.) with 1.6 M ammonium formate buffer (pH 4.0) (2.5% formic acid) containing 20% acetonitrile. Detection was effected at 655 nm. Chromatographic analysis was performed within 12 min. The detection limit of the method was about 4 ng/ml for urine and 10 ng/ml for plasma samples. The precision ranged from 3 to 11% depending on the amount of compound studied. This technique was applied to the monitoring of mitoxantrone in plasma and to the quantification of the unchanged compound and its two metabolites in urine from patients receiving 14 mg/m2 of mitoxantrone by intravenous infusion for 10 min.  相似文献   

17.
A novel high-performance liquid chromatographic method for the determination of codeine, norcodeine and morphine in plasma and urine has been developed. The compounds were separated on a cyano column (15 cm x 4.6 mm, 5 microns particle size) using a mobile phase of acetonitrile-triethylamine-distilled water (4:0.1:95.9, v/v) pH 3.1 and then determined by fluorescence detection. Calibration curves in the range 5-200 ng/ml for plasma and 0.1-10 micrograms/ml for urine were linear and passed through the origin. The imprecision and inaccuracy of the assay were less than 10% and the limits of detection were 2 ng/ml for all three compounds in human plasma.  相似文献   

18.
A highly sensitive and convenient gas chromatographic-mass spectrometric (GC-MS) method is described for the determination of 5-fluorouracil in the presence of 2'-deoxy-5-fluorouridine (which breaks down into 5-fluorouracil during ordinary GC derivatization) in biological samples such as plasma and urine. After extraction with ethyl acetate, 5-fluorouracil and 5-chlorouracil, the latter being used as an internal standard, were converted into their tert.-butyldimethylsilyl derivatives by allowing the mixture to stand for 30 min at room temperature and were assayed by electron-impact ionization GC-MS. Under these conditions, 2'-deoxy-5-fluorouridine did not decompose or interfere with the determination of 5-fluorouracil. The assay method, including the extraction and tert.-butyldimethylsilyl derivatization of 5-fluorouracil, showed good linearity in the range 0-100 ng/ml for 5-fluorouracil in plasma (detection limit 0.5 ng/ml) and urine (detection limit 1 ng/ml). The usefulness of this method was demonstrated by determining plasma concentrations of 5-fluorouracil in rats treated intravenously with 5-fluorouracil and 2'-deoxy-5-fluorouridine.  相似文献   

19.
A simple, selective and sensitive procedure is described for the quantitation of flupirtine maleate (FLU) and its active acetylated metabolite (Met. 1) in plasma and urine. Using a 0.5-ml sample, a sensitivity of 10 ng/ml is easily achieved with a reversed-phase octadecylsilane (C18) column, and a high-performance liquid chromatographic system with fluorescence detection. Quantitation from plasma involves addition of an internal standard, protein precipitation with acetonitrile and a sample concentrating step, while for urinalysis the samples are taken through a single extraction with methylene chloride. Analytical recoveries of FLU and Met. 1 from plasma averaged greater than or equal to 95%, while from urine only 60 and 50%, respectively, could be recovered. The overall, inter- and intra-day variability for both FLU and Met. 1 averaged 6, 5 and 3%, in plasma, respectively. Standard calibration plots in plasma were linear (r greater than or equal to 0.99) for FLU (range: 0.01-10.0 micrograms/ml) and Met. 1 (range: 0.5-25 micrograms/ml) over the extended range. A slightly modified elution system was employed for quantitation of FLU and Met. 1 in urine.  相似文献   

20.
Sensitive methods were developed for the analysis of dextromethorphan (I) and two metabolites, (+)-17-methyl-morphinan-3-ol (II) and (+)-morphinan-3-ol (III), in plasma as well as dextromethorphan and three metabolites II, III and (+)-3-methoxymorphinan (IV) in urine using high-performance liquid chromatography followed by detection with a fluorometer. Dextromethorphan and its metabolites were extracted from plasma and urine and separated in the reversed-phase mode. The practical lower limits of determination for I, II, and III in plasma were 0.5, 5, and 5 ng/ml, respectively; for I, II, III, and IV in urine, the limits were 20 ng/ml, 0.6 microgram/ml, 0.5 microgram/ml, and 15 ng/ml, respectively. The linearity of the calibration graphs was excellent (r varied from 0.9994 to 0.9999) over concentration ranges of two orders of magnitude.  相似文献   