首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
The elution behaviors of the biogenic amines, histamine (HA) and its metabolite methyl histamine (MHA), were evaluated by means of on-column derivatization (OCD)-capillary electrochromatography (CEC) which employed a monolithic octadecylsilica (ODS) capillary column (20 cm of effective length x 50 microm of inner diameter). Five kinds of alkylthiols, e.g., 2- hydroxyethylthiol (or 2-mercaptoethanol (2-ME)), ethanethiol (ET), 1-propanethiol (1-PT), 2-methyl-1-propanethiol (2-MPT) and 1-butanethiol (1-BT) were separately presented at 5 mM each in the OCD-CEC separation run buffer consisting of 60% acetonitrile in 5 mM o-phthalaldehyde (OPA)-10 mM borate buffer (pH 10). When 2-ME was present in the run buffer solution, both derivatives corresponding to HA and MHA migrated separately, but closely together through the capillary column. Replacement of 2-ME with 1-BT in the run buffer solution caused a delay in their elution profiles on the electrochromatogram and the separation between those two peaks became remarkably improved. The elution times of HA and MHA followed the increase in alkyl chain length or hydrophobicity of thiol, 1-BT > 2-MPT > 1-PT > ET > 2-ME. Performance of on-line preconcentrations of HA and MHA was also evaluated by varying the electrokinetic injection voltage from 1 kV to 8 kV. The peak area counts corresponding to HA recorded about 50 times higher when 2 kV was applied for 240 s to a 0.1 mM HA solution than when 8 kV was applied for 5 s. This method was next applied to a sample of human urine spiked with HA and MHA at levels of 0.1 microM each. Although HA and MHA peaks were not identifiable among the peaks corresponding to the materials in the urine matrix when OPA/2-ME was employed in a run buffer for the OCD-CEC, the separation and identification of their peaks became possible by replacing 2-ME with 1-BT in the run buffer solution.  相似文献   

2.
A pressurized gradient capillary electrochromatography (pCEC) instrument was developed to separate 18 amino acid derivatives. A reversed-phase C18 column (3 microm, 130 mm x 75 microm I.D.) and an acetate buffer (50 mmol/l NaAc, pH 6.4) with an ion-pair reagent (1% N,N-dimethylformamide) were used to separate derivatized amino acids from a standard solution (2 microg/ml), and the wavelength of the UV-Vis detector was 360 nm. The pressure on the capillary column was kept at approx. 70 Pa and 3 kV positive voltage was added on the outlet end of column. The effect of voltage on the eluting order of amino acids and the resolution of separation were studied, and it was found that when the voltage was higher than 3 kV, the adsorption of amino acids in the porous C18 column occurred. The effect of salt concentration, injection volume, and column length on the separation of amino acids was determined. The amino acid sample was separated by pCEC, and RSDs of the migration times of each amino acid were all less than 2.5%.  相似文献   

3.
Yamane T  Kouzaka Y  Hirakawa M 《Talanta》2001,55(2):387-393
A simple, rapid and sensitive system for the determination of trace boron in iron and steels is presented, in which in-line separation/preconcentration of boron from iron matrix is directly coupled with fluorimetric detection in a continuous flow system. Boron was adsorbed on a small column packed with Sephadex G-25 gel, followed by elution with a small volume of dilute hydrochloric acid. The formation of boron complex with 1,8-dihydroxy-3,6-naphthalenedisulphonic acid in a continuous flow system was used for the sensitive determination of boron by fluorescence detection(lambda(ex)=314 nm and lambda(em)=355 nm). The present FIA system offers many advantages over existing methods, especially with respect to simplicity and sensitivity, permitting semi-automated determination of boron with a short analysis time (about 10 min), low limit of determination (0.1 ppm in steels) and good reproducibility (rsd<3% for 1-18 mug g(-1) boron in steels).The present FIA system can be readily applied to the steel samples.  相似文献   

4.
An easy, rapid and sensitive method of analysis for capsaicin and dihydrocapsaicin and its application for determination of these two amides in fruit extracts of different varieties of Capsicum frutescens by micellar electrokinetic capillary chromatography has been developed. Optimum separation was achieved with a fused-silica capillary column (600 mm x 0.075 mm I.D) and a running buffer at pH 9.0 prepared from 15 mM sodium tetraborate and 15 mM sodium dihydrogenphosphate, and 67.5 mM sodium dodecyl sulphate. Addition of 15% (v/v) methanol in the running buffer was found to be essential for the separation. The applied voltage was +22.5 kV. The compounds were detected by UV at 214 nm. Both capsaicin and dihydrocapsaicin were detected within 11 min, with an excellent resolution.  相似文献   

5.
柱前手性衍生化反相高效液相色谱法分离拉贝洛尔对映体   总被引:4,自引:1,他引:3  
赵华  李惠芝  邱宗荫 《色谱》1999,17(4):369-371
以乙酰葡萄糖异硫氰酸酯(GITC)作柱前手性衍生化试剂,用反相高效液相色谱法成功地分离了拉贝洛尔的两对对映异构体,并以荧光检测和紫外检测作对照,确认了4个衍生物的色谱峰。  相似文献   

6.
The use of a macrocyclic polyamine, 28[ane]-N6O2, as a selective modifier in a bonded-phase capillary column for the electrophoretic separation of 14 aromatic acids is described. Parameters that affect the performance of the separations, such as the type of buffer, the pH and concentration of buffer, the applied potential and the injection mode were studied. By changing the buffer pH (4.0-5.0), buffer concentration (10-50 mM) and applied potential (-10 approximately -20 kV), optimum conditions were obtained at -20 kV, using an acetate buffer (20 mM, pH 4.5), hydrodynamic injection with a vacuum at the buffer reservoir on the detector side and detection at 220 nm. The results showed that the separation was effective under these conditions. The plate number was greater than 4 x 10(4) m-l. Due to the wide variation in the mobilities of the test compounds, injection studies suggested that a vacuum at the buffer reservoir on the detector side would produce a result that is more representative of the initial sample composition. Benzoic acid in soy sauce, salicylic acid in Salic ointment and Aspirin were sampled and analyzed using the established conditions.  相似文献   

7.
周建忠  廖杰  钱小红  董芳霆 《色谱》1997,15(2):159-160
建立了用毛细管胶束电动色谱法(MEKC)分离19种PTH氨基酸的方法,并探讨了电压、pH值、温度、胶束浓度对氨基酸迁移时间的影响。方法具有速度快、灵敏度高、样品用量少的优点。  相似文献   

8.
RP-HPLC拆分普萘洛尔对映体的洗脱顺序及其荧光响应研究   总被引:3,自引:1,他引:2  
王凌志  邱宗荫 《色谱》1997,15(5):411-413
应用反相高效液相色谱法,以(R,R)-O,O-二乙酰基酒石酸酐(DATAAN)为手性衍生化试剂,拆分了普萘洛尔(propranolol)对映体。实验结果显示:普萘洛尔对映体经衍生化而生成的两个非对映异构体分子的空间结构有着明显的差异,即(R,R,R)-异构体中存在着分子内氢键,而(R,R,S)-异构体中却没有,这种结构上的区别不仅成为控制洗脱顺序的主要因素,而且对其荧光响应也产生重要的影响。  相似文献   

9.
Microemulsion electrokinetic chromatography (MEEKC) coupled with a diode-array detector was developed for the simultaneous analysis of natural steroidal compounds, withanolides including withaferin A, withacnistin and iochromolide. Optimal resolution was obtained with a microemulsion consisting of 70 mM octane, 800 mM 1-butanol, 100 mM sodium dodecyl sulfate (SDS), and 10 mM phosphate-borate buffer (pH 7) using a fused-silica capillary at 25 kV and 40 degrees C. Since this technique is not compatible with mass spectrometry detection, a capillary electrochromatographic method was developed to separate the investigated withanolides. The effects of mobile phase composition and pH were systematically investigated. Complete separation was obtained with a capillary electrochromatography (CEC) Hypersil C18 bonded silica column (packed length, 25 cmx100 microm ID and 375 microm OD), packed with 3 microm particles. The mobile phase consisted of formic acid-ammonia, pH 8 / acetonitrile (40/60 v/v); the voltage was set at 25 kV and the temperature at 20 degrees C. Under these conditions, resolution of these closely related compounds, including the critical pair withacnistin and iochromolide, was achieved in less than 5 min. The separations by MEEKC and CEC were compared with that obtained by reversed-phase liquid chromatography and showed similar retention order, indicating the analogy of the retention mechanism of these techniques. To further improve specificity and sensitivity, the developed CEC method was interfaced with electrospray ionization mass spectrometry using a Teflon connection between the CEC column and a void fused-silica capillary. Finally, the described methods were applied to the qualitative analysis of withanolides in Iochroma gesnerioides plant extract.  相似文献   

10.
彭军  王复  朱明华 《色谱》1999,17(1):90-92
分别用高效液相色谱法(HPLC)、毛细管区带电泳法(CZE)、胶束电动毛细管色谱法(MECC)测定了甘草制品中甘草酸的含量。对HPLC,CZE,MECC的分析条件作了一些选择实验,结果表明MECC法与HPLC法分析数据接近、比较准确,而且前者比HPLC法分离效率高、溶剂用量少,是一种很有发展潜力的分析方法。  相似文献   

11.
Immunoglobulins are present in most tissues and plasma and play crucial role in immune system. Alteration of the levels of the immunoglobulin G (IgG) subclasses (IgG1, IgG2, IgG3 and IgG4) is an indication of a disturbed immunological response. The aim of the present study was the development of a capillary electrophoresis (CE) method for the analysis of IgG subclasses in respect to their variable kappa and lambda chains. Various analytical conditions and CE modes, including capillary zone electrophoresis (CZE), capillary isoelectric focusing (CIEF) and micellar electrokinetic capillary chromatography (MECC) have been thoroughly studied. CZE was found to be the most convenient way to separate IgG subclasses. Three of the human IgG subclasses were resolved using uncoated fused-silica and 50 mM phosphate, pH = 9.3, as operating buffer at 20 kV and detection at 214 nm. IgG1kappa was completely separated from IgG2kappa and IgG3kappa, whereas IgG2kappa co-migrated with IgG4kappa, which is the minor IgG subclass. Under the same conditions IgG4lambda was completely separated from IgG1lambda, IgG2lambda and IgG3lambda, enabling the identification of the various lambda chains. The developed CE method is rapid and can be applied to the identification of the major immunoglobulin G subclasses in respect to their variable kappa and lambda chains.  相似文献   

12.
Benzodiazepines, namely flunitrazepam and its three major metabolites, were successfully separated by microemulsion electrokinetic chromatography. Separation was achieved using an untreated fused-silica capillary (48 cm (effective length 40 cm) x 50 num) at 25 kV; detection was performed by UV at 220 nm. The microemulsion system consisted of 70 mM octane, 800 mM 1-butanol, 80 mM sodium dodecyl sulfate (SDS) and 10 mM borate buffer, pH 9. Very high efficiencies (up to 400 000 plates) and resolution better than 3 were achieved. Since this technique is not compatible with mass spectrometry (MS) detection, a capillary electrochromatographic (CEC) method was developed to separate flunitrazepam and its metabolites. The effects of mobile phase composition and pH as well as voltage and temperature were systematically investigated. The optimized CEC method allowed the baseline separation of the investigated compounds. For the on-line coupling of CEC with electrospray ionization-mass spectrometry, the column was connected to a void fused-silica capillary using a Teflon connection. This configuration was found efficient and suitable for hyphenation of commercial CEC and MS instrumentation using commercially available CEC columns.  相似文献   

13.
Pulgarín JA  Molina AA 《Talanta》2002,56(3):557-564
A method for the determination of salicylamide at concentrations between 25 and 350 ng ml(-1) by use of matrix isopotential synchronous fluorescence spectrometry (MISF) in combination with derivative techniques is proposed. The method allows the determination of compounds in samples with unknown background fluorescence without the need for tedious pre-separation. Synchronous scans are performed along a trajectory that connects points of identical intensity in a three-dimensional fluorescence spectrum. The unknown analytical signal of the serum is suppressed from the MISF spectrum, by calculating its first derivative at lambda(exc)=324 nm and lambda(em)=392 nm. In order to ensure maximum sensitivity and adequate selectivity, the experimental variables affecting the fluorescence intensity of the salicylamide band at lambda(exc)=328 nm and lambda(em)=418 nm were studied. Based on the results, the determination was performed in an aqueous medium at pH 12 that was adjusted with a sodium phosphate/hydrogen phosphate buffer. Calibration graphs were subjected to a comprehensive statistical analysis. The error propagation has been considered in order to calculate the detection limit by the criterium of Clayton.  相似文献   

14.
This study concerns the technique electric field-assisted capillary liquid chromatography. In this technique, an electric field is applied over the separation capillary in order to provide an additional selectivity. In this technique, the electric field is applied in-line in the separation capillary and here the electric current is the factor limiting the magnitude of applied electric field. The influence of Joule heating and other factors on the current in such systems has been investigated. The temperature in the capillary was first measured within a standard CE set-up, as function of effect per unit of length. Then the same cooling system was applied to an in-line set-up, to replicate the conditions between the two systems, and thus the temperature. Thus Joule heating effects could then be calculated within the in-line system. It was found that for systems applying an electric field in line, the direct influence from Joule heating was only relatively small. The pH in the capillary was measured in the in-line set-up using cresol red/TRIS solutions as pH probe. Significant changes in pH were observed and the results suggested that electrolysis of water is the dominant electrode reaction in the in-line system. In summary, the observed conductivity change in in-line systems was found to be mainly due to the pH change by hydrolysis of water, but primarily not due the temperature change in the capillary column.  相似文献   

15.
以4-氟-7-硝基-2,1,3-苯并氧杂恶二唑(NBD-F)为衍生化试剂,建立了食品中5种痕量生物胺(色胺、组胺、酪胺、亚精胺、精胺)的毛细管电色谱-激光诱导荧光检测(CEC-LIF)分析方法。采用50 mmol/L硼酸盐缓冲溶液(pH 8.0)作为衍生介质,在75℃条件下对生物胺进行衍生化反应25 min。生物胺衍生产物的最优色谱条件:固定相为C18毛细管电色谱柱,流动相为乙腈-乙酸铵(20 mmol/L,pH 8.0)(75∶25,v/v),辅助压力为6.9 MPa,分离电压为-8 kV,流速为0.03 mL/min。实验结果表明,生物胺的检出限(LOD,S/N=3)为0.1~1.0μg/L,加标回收率为78.3%~113.9%。该方法可成功用于加工和发酵食品中生物胺的测定,结果与传统HPLC法的检测结果无显著性差异,且检出限更低、分析速度更快,对于食品中痕量污染物的残留监测具有应用价值。  相似文献   

16.
A fast analytical method has been developed for the determination of nine amino acids, together with serotonin, in wine samples of different origin and vintage. The method is based on capillary electrophoresis coupled to laser-induced fluorescence detection. Separation was obtained by using a fused-silica capillary (75?μm id, 74.0?cm total length, 60.0?cm length to detector) and a background electrolyte composed of carbonate buffer (20?mM, pH 9.2), applying a 20?kV voltage. Direct hydrodynamic injection of wine samples was made after an original microwave-assisted derivatisation step with 5-(4,6-dichlorotriazinyl)aminofluorescein. Fluorescence was induced by an Ar-Ion laser, exciting at 488?nm. Good linearity (r(2) >0.9990) was obtained for all considered analytes and sensitivity was also good, with limits of detection in the 7-50?ng/mL range. The method was successfully applied for the analysis of commercial Italian wines and thus seems to be suitable for the determination of the relevant amino acids and serotonin, providing good results in terms of accuracy and precision, together with the advantage of a very fast, microwave-assisted derivatisation procedure. Future applications of the method are planned to check for wine adulterations and commercial frauds.  相似文献   

17.
王玉红  刘芳  赵卉  王建民  王彦  阎超 《分析化学》2012,40(10):1622-1626
构建了适用于纳升级到微升级流量的毛细管分离体系的微流蒸发光散射检测器(μELSD),实现了其与毛细管液相色谱(eLC)的联用.对雾化器孔径和雾化毛细管内径、蒸发管内径和长度、光散射池尺寸、雾化毛细管位置和辅助载气流量等参数进行了优化.在最优条件下,微流蒸发光散射检测器检出限为直接进样葡萄糖1 ng(S/N> 10),线性范围0.01~1.0 μg,重复性好,峰面积RSD(n=6)为0.4%,峰高RSD(n=6)为0.3%.本检测器已成功应用cLC-μELSD平台,使用C18毛细管色谱柱(内径250 μm),0.1%甲酸铵溶液(pH 4.5)-甲醇(60∶40,V/V)为流动相,分离检测了3种常用甜味剂,表明本研究构建的系统可以应用于实际分离检测中,具有分析时间快、溶剂消耗量少、样品需求量小的优点.  相似文献   

18.
Fast, efficient separation of most common biogenic amines was successfully performed on a glass microchip capillary electrophoresis device. The amines putrescine, histamine, tyramine, cadaverine, phenethylamine, tryptamine, spermidine and spermine were derivatized prior to fluorescence detection with fluorescein isothiocyanate. Separation was carried out using a channel length of 28 mm, a cross section of 50 x 8 microm, and a field strength of 600 V/cm. After optimization of buffer electrolyte conditions (120 mM boric acid, pH 9.4, modified with 40 mM SDS), fluorescein thiocarbamyl amine derivatives were successfully resolved. Analysis time was as short as 75 s. Determination of the biogenic amines was achieved in soy sauce samples.  相似文献   

19.
闫小华  张毕奎  李焕德  马鸿宪 《色谱》2000,18(5):432-435
 建立了一种紫外检测器(UVD)与荧光检测器(FLD)串联的HPLC法,检测了火力发电厂环境中的多环芳烃(PAH)化合物。在所选择的色谱条件下12个PAH可得到完全分离,其中萘等8个PAH用UVD检测,苯并〔a〕芘等4个PAH用FLD检测。应用该方法对湖南省内几家火力发电厂的废水、烟道气、粉煤灰中的12个PAH进行了实测,效果良好。  相似文献   

20.
Gillespie E  Connolly D  Macka M  Hauser P  Paull B 《The Analyst》2008,133(8):1104-1110
A capacitively coupled contactless conductivity detector cell was designed and constructed suitable for standard HPLC 1.6 mm o.d. (1/16') tubing and columns. Bode plots were acquired in order to determine the optimum input frequency for the new detector cell, with three feedback resistors of increasing resistance (1 MOmega, 3.3 MOmega and 4.7 MOmega) alternately fitted to maximize sensitivity. To evaluate the new detector geometry, a 190 mm x 0.381 mm i.d. (1.59 mm o.d.) column packed with Dionex OmniPac 8.5 microm PAX-100 anion exchange resin was used, with an eluent of 0.5 mM sodium benzoate containing 2% methanol, pumped at 20 microL min(-1), with detection taking place 'on-column'. Standard analytical performance criteria were used to compare the test detector with a commercially available TraceDec C(4)D capillary (360 microm o.d.) detector, with the new detector cell matching the performance of the commercial instrument in terms of linearity, sensitivity and reproducibility. In 'on-column' detection mode, the detector cell could be moved during (or between) chromatographic runs along the length of the packed column bed, to shorten the effective length of the column and thus reduce the retention time of strongly retained sample components, whilst maintaining the resolution of weakly retained components. In addition, the detector could also be applied to the evaluation of the stationary phase packing homogeneity by physically scanning the entire length of the micro-bore column with the moveable detector cell.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号