首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Purification of compounds from traditional Chinese medicines (TCMs) is an important task for understanding the chemical composition of TCMs. However, it is difficult to obtain compounds with high enough purity for identification by NMR due to the complexity of TCMs in chemical composition. In this study, a two‐dimensional purification method based on a Click oligo (ethylene glycol) column and a C18 column was developed to realize an orthogonal separation in preparative level for purifying compounds efficiently. The first dimensional preparation was performed on a Click oligo (ethylene glycol) column to simplify the sample into the fractions with good separation repeatability. On the first dimension, 7.2 g sample was separated into 11 fractions with a recovery of 86% within 6 h. A C18 column was taken as the second dimension to realize the high‐performance separation and rapid preparation from the fractions collected from the first dimension. Eight compounds in fraction 6 and 2 compounds in fraction 8 were isolated and identified after optimizing the separation and collection parameters. This method is a high‐efficient and orthogonal preparation method to improve the separation of a complex sample and increase the purity of the compounds, which benefits from the application of novel materials in the preparation and purification.  相似文献   

2.
通过十八烷基胺的氨基与二醛微晶纤维素的醛基共价键合,制备了基于二醛微晶纤维素(DMCC)官能化C18的新型反相/亲水色谱固定相(C18-DMCC/SiO2),该色谱固定相被用于反相色谱(RPLC)和亲水相互作用色谱(HILIC)模式。C18-DMCC/SiO2色谱柱展现了良好的疏水选择性和芳香选择性,在反相色谱模式下可分离烷基苯和多环芳烃(PAHs)。苯胺类、酚类和糖苷类等极性化合物被用于评估该色谱柱在反相色谱模式下的极性选择性,商品C18柱作对照柱,色谱评价结果令人满意。核酸碱基被用于评估C18-DMCC/SiO2色谱柱的亲水色谱性能。通过考察有机溶剂含量对分析物保留的影响,发现该新型色谱固定相具有反相/亲水色谱的典型特征。  相似文献   

3.
An efficient method for purification of alkaloids from Corydalis yanhusuo W. T. Wang using HPLC was developed, featuring a polar-copolymerized stationary phase named C18HCE. As ionizable solutes, the crude alkaloid sample often suffered from serious peak tailing problem on conventional RP-LC columns, and the separation would rapidly became destroyed with the increasing of load amount. However, on the new stationary phase, good peak shapes (asymmetry factor <1.5) as well as good loadability were easily obtained in a commonly used acidic mobile phase condition. The loading amount could reach 10 mg per injection on an analytical C18HCE column for laboratory-scale purification. About 6.8 mg of palmatine (HPLC purity >98%) and 44.4 mg of dehydrocorydaline (HPLC purity >98%) were rapidly derived from 200 mg of the crude alkaloid sample, and the recoveries of these two compounds were 76.5 and 81.7%, respectively. The purified alkaloids were characterized by comparing retention times with standard compounds as well as (1)H-NMR data. The new method is simple and high yielding, and it may provide a promising tool for purification of alkaloids as well as other alkaline compounds.  相似文献   

4.
Comprehensive two-dimensional (2D) HPLC in the reversed-phase liquid chromatography (RPLC) mode using C18 silica monolith columns at first dimension (1st-D) (10 cm x 4.6mm I.D.) and second dimension (2nd-D) (5 cm x 4.6mm I.D.) was carried out successfully. A mixture of water and tetrahydrofuran (THF) was used as a mobile phase in the 1st-D separation, and a mixture of water and methanol (CH3OH) in the 2nd-D separation. Sample fractions from 1st-D column were directly loaded into an injection loop of the 2nd-D HPLC equipped with two injector valves for one column. The fractionation time at the 1st-D that was equal to the separation time at the 2nd-D was 45 or 60s. Total peak capacity up to 900 was obtained in about 60 min for the isocratic mode separation of aromatic compounds in this system. Gradient elution mode applied to both 1st-D and 2nd-D separations resulted in shorter separation time and better separation efficiencies than the isocratic mode. It was demonstrated that 2D-HPLC systems employing popular C18 stationary phases with different organic modifiers in mobile phases for each dimension could produce large peak capacity. The different selectivities were provided by the difference in polar interactions between a solute and the organic modifier existing in the stationary phase.  相似文献   

5.
Fingerprint analysis is considered one of the most powerful approaches to quality control in traditional Chinese medicines (TCMs). In this study, a binary chromatographic fingerprint analysis was developed using hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) to gain more chemical information about polar compounds and weakly polar compounds. This method was used to construct a chromatographic fingerprint of Ligusticum chuanxiong. The two chromatographic methods demonstrated good precision, reproducibility, and stability, with relative standard deviations of <2% for retention time and 7% for peak area for both HILIC and RPLC separations. Data from the analysis of 14 samples by HILIC and RPLC were processed with similarity analysis, with correlation coefficients and congruence coefficients. This binary fingerprint analysis, using two chromatographic modes, is a powerful tool for characterizing the quality of samples, and can be used for the comprehensive quality control of TCMs.  相似文献   

6.
A mixed-mode chromatographic packing material, C18 and diol groups modified silica (C18-Diol), was prepared with controllable hydrophobicity and hydrophilicity. It demonstrated excellent aqueous compatibility and stability in aqueous mobile phase; compared to the traditional C18 column, improved peak shape of basic analytes was also obtained. Additionally, it exhibited both reversed-phase liquid chromatographic (RPLC) and hydrophilic interaction chromatographic (HILIC) performance; the analyte separation scope was thus enlarged, demonstrated by simultaneous separation of twenty acids, bases and neutrals. More interestingly, a novel on-line two-dimensional liquid chromatography on the single column (2D-LC-1C) was established by modifying the high performance liquid chromatographic instrument only with the addition of an extra six-port two-position valve. The early co-eluted components of the extract of Lonicera japonica on the 1st-dimension (RPLC) were collected for the online re-injection to the 2nd-dimension (HILIC) by conveniently varying the mobile phase components. Six more peaks were obtained. The established system was simple, easy operation and low cost, which had advantages in analyzing complicated samples.  相似文献   

7.
建立了亲水/反相二维制备液相色谱(Pre-2D-HILIC/RPLC)分离纯化络石藤中化学成分的分析方法。络石藤药材经醇提、活性炭脱色后用反相固相萃取柱除去色素和强极性物质,最终得到干燥的浅黄色粉末。一维亲水色谱选择Click XIon色谱柱(250 mm×20 mm,10μm)作为固定相,水和乙腈作为流动相,进行梯度洗脱,以紫外触发模式收集馏分,共得到15个组分。二维反相色谱选择C18色谱柱(250 mm×20 mm,5μm)作为固定相,水和乙腈作为流动相,进行梯度洗脱,最终得到14个高纯度化合物,并通过质谱和核磁共振对其进行确认。实验结果表明,该法具有良好的正交选择性,可以有效提高分离度和峰容量,对于分离络石藤等复杂样品具有重要意义。  相似文献   

8.
Purification of high‐purity compounds from traditional Chinese medicines (TCMs) plays an important role in investigating their bioactivity. Nevertheless, it is often quite difficult to isolate compounds with high purity because of the complexity of TCMs in chemical composition. In this work, a two‐dimensional preparation method was successfully developed for the preparation of high‐purity compounds from the stem of Lonicera japonica Thunb, based on two novel polar copolymerized RP stationary phases, XAqua C3 and XAqua C18. An XAqua C3 prep column was used to separate the sample in the first‐dimensional preparation, and 14 g of sample was fractionated into eight fractions with a recovery of 82%. An XAqua C18 prep column was selected to prepare high‐purity compounds in the second‐dimensional preparation for its good orthogonality with the XAqua C3 stationary phase. As a result, major compounds in the sample were isolated with more than 99% purity. This method is a potent method to realize the efficient purification of compounds with high purity from the stem of L. japonica Thunb and it shows great potential in the separation of high‐purity compounds from complex samples.  相似文献   

9.
硅胶色谱柱的亲水作用保留机理及其影响因素   总被引:1,自引:0,他引:1  
李瑞萍  袁琴  黄应平 《色谱》2014,32(7):675-681
亲水作用色谱(HILIC)是替代反相色谱(RPLC)分离强极性及亲水性化合物的另一色谱模式,其分离机理与RPLC有很大不同,具有和RPLC互补的选择性。在HILIC模式中,采用正相色谱(NPLC)中的极性固定相及含高浓度有机溶剂(通常为乙腈)的水溶液为流动相。硅胶是开发最早、研究最为深入及应用最为广泛的HILIC固定相,本文介绍了硅胶色谱柱的HILIC保留机理,详细概述了操作条件如硅胶柱类型、流动相组成及柱温对HILIC分离的影响,并对硅胶填料色谱柱的HILIC模式的发展方向与应用前景进行了展望。  相似文献   

10.
Hu L  Li X  Feng S  Kong L  Su X  Chen X  Qin F  Ye M  Zou H 《Journal of separation science》2006,29(6):881-888
A mode of comprehensive 2-D LC was developed by coupling a silica-bonded HSA column to a silica monolithic ODS column. This system combined the affinity property of the HSA column and the high-speed separation ability of the monolithic ODS column. The affinity chromatography with HSA-immobilized stationary phase was applied to study the interaction of multiple components in traditional Chinese medicines (TCMs) with HSA according to their affinity to protein in the first dimension. Then the unresolved components retained on the HSA column were further separated on the silica monolithic ODS column in the second dimension. By hyphenating the 2-D separation system to diode array detector and MS detectors, the UV and molecular weight information of the separated compounds can also be obtained. The developed separation system was applied to analysis of the extract of Rheum palmatum L., a number of low-abundant components can be separated on a single peak from the HSA column after normalization of peak heights. Six compounds were preliminarily identified according to their UV and MS spectra. It showed that this system was very useful for biological fingerprinting analysis of the components in TCMs and natural products.  相似文献   

11.
建立了亲水相互作用色谱柱(HILIC)串联C18柱的方法,高效分离实际样品中的胭脂红,并对色谱柱的串联顺序以及色谱分离条件进行优化。结果表明:当HILIC柱在前C18柱在后,流动相为乙腈-乙酸铵(5 mmol/L)=91∶9(V/V),流速为0.9 mL/min,柱温为25℃,检测波长为508 nm时,此时胭脂红的分离效果最佳。在最佳的色谱分离条件下,选用两种市售饮品进行实际样品的测定,回收率在81.2%~119%。方法适用于水相样品中的强极性物质的高效分离与分析。  相似文献   

12.
The goal of this study was to compare the performance of three separation techniques for the analysis of 57 hydrophilic compounds. RPLC, hydrophilic interaction liquid chromatography (HILIC) and subcritical fluid chromatography (SFC) were tested. The comparison was based on the retention, selectivity, peak shape (asymmetry and peak width) and MS sensitivity. As expected, RPLC had some obvious limitations for such classes of compounds, and on average the %ACN required to elute these hydrophilic substances was 4, 7, and 11% ACN at pH 3, 6, and 9, respectively. However, a hybrid polar‐embedded C18 phase with an appropriate mobile phase could represent a viable strategy for hydrophilic basic compounds with log D greater than –2 on average. HILIC and SFC were found to be more appropriate for analyzing a large majority of these hydrophilic analytes (~60 and 70% of compounds eluted during the gradient in HILIC and SFC), while maintaining good MS sensitivity. Finally, this work demonstrated the complementarity of the three analytical techniques and showed that the selection of a suitable strategy should mostly be based on physicochemical properties of the analytes (pKa, log D, H‐bonding capability, etc.).  相似文献   

13.
Reversed‐phase liquid chromatography coupled with middle chromatogram isolated gel column was employed for the efficient preparative separation of the arylbutanoid‐type phenol [(‐)‐rhododendrin] from Saxifraga tangutica. Universal C18 (XTerra C18) and XCharge C18 columns were compared for (‐)‐rhododendrin fraction analysis and preparation. Although tailing and overloading occurred on the XTerra C18 column, the positively charged reversed‐phase C18 column (XCharge C18) overcame these drawbacks, allowing for favorable separation resolution, even when loading at a on a preparative scale (3.69 mg per injection). The general separation process was as follows. First, 365.0 mg of crude (‐)‐rhododendrin was enriched from 165 g Saxifraga tangutica extract via a middle chromatogram isolated gel column. Second, separation was performed on an XTerra C18 preparative column, from which 73.8 mg of the target fraction was easily obtained. Finally, the 24.0 mg tailing peak of (‐)‐rhododendrin on XTerra C18 column was selectively purified on the XCharge C18 analytical column. These results demonstrate that the tailing nonalkaloid peaks can be effectively used for preparative isolation on XCharge C18 columns.  相似文献   

14.
Chromatographic evaluations of a C18 dimethylurea phase in 150 mm x 3.9 mm HPLC columns were performed using the Tanaka and Engelhardt test mixtures. The applicability of the new C18 dimethylurea phase was also evaluated with a mixture of some herbicides and their metabolites. An artificial aging procedure was also performed by passing a potassium phosphate mobile phase buffered at pH 7.0 through C18 50 mm x 3.9 mm dimethylurea columns. The column stability was evaluated by means of the chromatographic parameters obtained for the separation of some compounds from the Neue test mixture, using apolar, polar and highly basic analytes.  相似文献   

15.
Chen X  Kong L  Su X  Pan C  Ye M  Zou H 《Journal of chromatography. A》2005,1089(1-2):87-100
An approach for the separation and identification of components in a traditional Chinese medicine Psoralea corylifolia was developed. Ion-exchange chromatography (IEC) was applied for the fractionation of P. corylifolia extract, and then followed by concentration of all the fractions with rotary vacuum evaporator. Each of the enriched fractions was then further separated on an ODS column with detection of UV absorbance and atmospheric pressure chemical ionization mass spectrometer (APCI/MS), respectively, and also analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) with matrix of oxidized carbon nanotubes. Totally more than 188 components in P. corylifolia extract were detected with this integrated approach, and 12 of them were preliminary identified according to their UV spectra and mass spectra performed by APCI/MS and MALDI-TOF/MS. The obtained analytical results not only demonstrated the powerful resolution of integration IEC fractionation with reversed-phase liquid chromatography (RPLC)-APCI/MS and MALDI-TOF/MS for analysis of compounds in a complex sample, but also exhibited the superiority of APCI/MS and MALDI-TOF/MS for identification of low-mass compounds, such as for study of traditional Chinese medicines (TCMs) and metabolome.  相似文献   

16.
Quantification of neurotransmitters as biologically active analytes in neurological samples is of high interest for studying their effect on multiple targets. This work is part of a strategy involving two-dimensional liquid chromatography (2D LC) system with mass spectrometry (MS) detection. The concept of the on-line LC system is the coupling of reversed phase liquid chromatography (RPLC, the second separation dimension) to ion-exchange chromatography (IEC, the first dimension). Our objective in this study is to find the appropriate second dimension column, ensuring that samples of neurotransmitters are refocused and separated on it. Silica-based columns designed specifically to retain polar compounds were tested in LC conditions and compared with results obtained with a porous graphitic carbon (PGC, Hypercarb) column. These polar embedded, polar endcapped, and high-density alkyl chain columns successfully separated analytes in question using mobile phase systems with high percentage of water, or even pure water. Only Hypercarb column provided efficient retention of the most polar neurotransmitters and could be used for trapping and preconcentrating the compounds without rapid breakthrough.  相似文献   

17.
Guo Y  Yuan Q  Li R  Huang Y 《色谱》2012,30(3):232-238
亲水作用色谱(HILIC)是一种分离极性和亲水性化合物的液相色谱模式,其作为反相液相色谱(RPLC)的重要补充,近年来越来越受到各个领域的关注和重视。这不只是因为强极性化合物的分离问题在各个领域引起了重视,而且因为与RPLC比较,HILIC具有流动相组成黏度低、色谱柱渗透性好、与质谱联用的灵敏度高及反压较低等优势。本文简要概述了HILIC的发展历程、特点及保留机理,重点介绍了HILIC用于环境分析的最新进展,评述了HILIC及RPLC用于污染物分析的优缺点,并指出了HILIC用于环境分析的未来发展趋势。  相似文献   

18.
The separation of basic macrolide antibiotics suffers from peak tailing and poor efficiency on traditional silica‐based reversed‐phase liquid chromatography columns. In this work, a C18HCE column with positively charged surface was applied to the separation of macrolides. Compared with an Acquity BEH C18 column, the C18HCE column exhibited superior performance in the aspect of peak shape and separation efficiency. The screening of mobile phase additives including formic acid, acetic acid and ammonium formate indicated that formic acid was preferable for providing symmetrical peak shapes. Moreover, the influence of formic acid content was investigated. Analysis speed and mass spectrometry compatibility were also taken into account when optimizing the separation conditions for liquid chromatography coupled with tandem mass spectrometry. The developed method was successfully utilized for the determination of macrolide residues in a honey sample. Azithromycin was chosen as the internal standard for the quantitation of spiramycin and tilmicosin, while roxithromycin was used for erythromycin, tylosin, clarithromycin, josamycin and acetylisovaleryltylosin. Good correlation coefficients (r2 > 0.9938) for all macrolides were obtained. The intra‐day and inter‐day recoveries were 73.7–134.7% and 80.7–119.7% with relative standard deviations of 2.5–8.0% and 3.9–16.1%, respectively. Outstanding sensitivity with limits of quantitation (S/N ≥ 10) of 0.02–1 μg/kg and limits of detection (S/N ≥ 3) of 0.01–0.5 μg/kg were achieved.  相似文献   

19.
A novel polar-copolymerized C8 stationary phase composed of octyl and chloropropyl (C8-C3Cl)-bonded silica has been developed for protein separation. Separation of standard proteins on this homemade column was investigated and compared with separation on a Waters Symmetry 300 C4 column. Results indicated that the chromatographic performance of the homemade column in the separation of proteins was excellent. The new polar copolymerized C8 stationary phase enabled glycoprotein separation with good resolution and reproducibility. It was also used for purification of ovalbumin glycoprotein in order to improve identification of the protein.  相似文献   

20.
Two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography (2D-RPLC/HILIC) system was successfully applied for comprehensive characterization of steviol glycosides from Stevia rebaudiana. The experiments were performed in offline mode using an XCharge C18 column in first dimension and an XAmide column in second dimension. In first dimension, preliminary separation of Stevia aqueous extract was accomplished and 30 fractions were collected. Then fractions 1-20 were selected for further purification and 13 compounds with high purity were obtained in second dimension. Comprehensive characterization of these compounds was completed by determination of their retention time, accurate molecular weight, diagnostic fragmentation ions, and nuclear magnetic resonance spectroscopy. As a result, all nine known steviol glycosides, as well as other four steviol glycosides were fully purified. The result demonstrated that this procedure is an effective approach for the preparative separation and comprehensive characterization of steviol glycosides in Stevia. This 2D-RPLC/HILIC method will be a promising tool for the purification of low-abundance compounds from natural products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏