首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
张琪 《色谱》2020,38(9):1028-1037
在现代分离科学中,手性化合物的分离分析一直是研究的重点和难点。相比于高效液相色谱(HPLC)、气相色谱(GC)等传统色谱分析方法,毛细管电泳(CE)技术凭借其高效率、低消耗、分离模式多样化等诸多优势,已经发展成为手性分离研究领域最有应用前景的分析方法之一。近年来,研究人员在CE手性分析方法的构建过程中,基于毛细管电动色谱(EKC)、配体交换毛细管电泳(LECE)、毛细管电色谱(CEC)等各种基础电泳模式,不断地对传统手性分离体系进行优化和改造,构建出了许多高性能的新型手性CE分离体系。如利用各类功能化离子液体以"手性离子液体协同拆分""手性离子液体配体交换""离子液体手性选择剂"等模式设计出多种基于离子液体的CE手性分离体系;利用纳米材料独特的尺寸效应、多样性、可设计性等特点,直接或与传统手性选择剂有机结合构建CE手性分离体系。此外,金属有机骨架材料修饰、低共熔溶剂修饰、非连续分段式部分填充等各式新颖的CE手性分离体系也都被研究人员成功开发,并表现出较大的发展潜力。该综述将对近年来(尤其是2015~2019年)此类新型CE手性分离体系的发展状况进行梳理,并结合相应的手性识别机理研究和手性CE方法实际应用情况,对该领域存在的问题及发展前景进行分析和展望。  相似文献   

2.
The separation of drug enantiomers using proteins as the chiral selectors in capillary electrophoresis (CE) is considered in this review. The proteins used include albumins such as bovine serum albumin, human serum albumin and serum albumins from other species, glycoproteins such as alpha1-acid glycoprotein, crude ovomucoid, ovoglycoprotein, avidin and riboflavin binding protein, enzymes such as fungal cellulase, cellobiohydrolase I, pepsin and lysozyme and other proteins such as casein, human serum transferrin and ovotransferrin. Protein-based CE is carried out in two modes: in one proteins are immobilized or adsorbed within the capillary, or protein-immobilized silica gels are packed into the capillary (affinity capillary electrochromatography mode), and in the other proteins are dissolved in the running buffer (affinity CE mode). Furthermore, the advantages and limitations of the two modes and the factors affecting the chiral separations of various drugs by protein-based CE are discussed.  相似文献   

3.
《Electrophoresis》2017,38(3-4):533-539
In this study, an optimized method using capillary electrophoresis (CE) with a direct contactless conductivity detector (C4D) for a new application field is presented for the quantification of fluoride in common used lithium ion battery (LIB) electrolyte using LiPF6 in organic carbonate solvents and in ionic liquids (ILs) after contacted to Li metal. The method development for finding the right buffer and the suitable CE conditions for the quantification of fluoride was investigated. The results of the concentration of fluoride in different LIB electrolyte samples were compared to the results from the ion‐selective electrode (ISE). The relative standard deviations (RSDs) and recovery rates for fluoride were obtained with a very high accuracy in both methods. The results of the fluoride concentration in the LIB electrolytes were in very good agreement for both methods. In addition, the limit of detection (LOD) and limit of quantification (LOQ) values were determined for the CE method. The CE method has been applied also for the quantification of fluoride in ILs. In the fresh IL sample, the concentration of fluoride was under the LOD. Another sample of the IL mixed with Li metal has been investigated as well. It was possible to quantify the fluoride concentration in this sample.  相似文献   

4.
This review, covering reports published from 2001 to December 2008, shows how ionic liquids (ILs) have made significant contributions in the improvement of capillary and microchip electrophoresis (CE and μCE) for the separation and detection of analytes such as phenols and aromatic acids, metal ions, medicines, enantiomers, biological materials, etc. Furthermore, CE methods applied in the sensitive and accurate determination of physico-chemical properties of ILs have been summarized. Accordingly, research vacancies and future development trends in these areas are discussed.  相似文献   

5.
TANAKA Yoshihide 《色谱》2002,20(4):317-327
 Capillary electrophoresis (CE) has become a powerful tool for enantiomer separations during the last decade. Since 1993, the author has investigated enantiomer separations by affinity capillary electrophoresis (affinity CE) with some proteins and by cyclodextrin electrokinetic chromatography (CDEKC) with some charged cyclodextrins (CDs). Many successful enantiomer separations are demonstrated from our study in this review article. In the enantiomer separations by affinity CE, the deterioration of detection  相似文献   

6.
In this study, we report the effects of adding ionic liquids (ILs), as compared to adding conventional molecular organic solvents (MOSs), to aqueous buffer solutions containing molecular micelles in the separation of chiral analyte mixtures in micellar EKC (MEKC). The molecular micelle used in this study was polysodium oleyl-L-leucylvalinate (poly-L-SOLV). The ILs were 1-alkyl-3-methylimidazolium tetrafluoroborate, where the alkyl group was ethyl, butyl, hexyl, or octyl. These ILs were chosen due to their hydrophobicity, good solvating, and electrolyte properties. Thus, it was expected that these ILs would have favorable interactions with chiral analytes and not adversely affect the background current. Common CE buffers, mixed with a molecular micelle, and an IL or a MOS, were used for these chiral separations. The buffers containing an IL in the concentration range of 0.02-0.1 v/v were found to support a reasonable current when an electric field strength of 500 V/cm was applied across the capillary. However, a current break down was observed for the buffers containing more than 60% v/v MOS on application of the above-mentioned electric field. The chiral resolution and selectivity of the analytes were dependent on the concentration and type of IL or MOS used.  相似文献   

7.
A novel chiral selector, clindamycin succinate, was synthesized and first used as a chiral selector in capillary electrophoresis (CE). The chiral resolution ability of this kind of clindamycin derivation was studied by CE using some racemic drugs as model analytes. From the experimental results, it was found that both resolution and selectivity of the selector were dependent on the following parameters: concentration of chiral selectors, pH of the running buffer, temperature of the capillary column, applied voltage and organic modifier used. The results show that the chiral selector possesses high resolution toward some racemic drugs, including ofloxacin, chlorphenamine, tryptophan, propranolol, sotalol and metoprolol. Excellent chiral resolution of these tested drugs was achieved under the optimal conditions of 50 mM clindamycin succinate, 10% MeOH v/v, 50 mM Tris buffer, pH 4.0, at 22 kV and 20 °C within 25 min.  相似文献   

8.
Ionic liquids as electrolytes for nonaqueous capillary electrophoresis   总被引:2,自引:0,他引:2  
Acetonitrile is a well-suited medium for nonaqueous capillary electroseparations and enables extending the range of applications of capillary electrophoresis (CE) techniques to more hydrophobic species. In this study, the dialkylimidazolium-based low temperature melting organic salts know as "ionic liquids" (ILs) are used as electrolytes. At room temperature these liquids are miscible with acetonitrile which makes it easy to use them for adjustment of analyte mobility and separation. The anionic part as well as the concentration of an IL influence the general electrophoretic mobility of the buffer system. The separation of different analytes is achieved because they become charged in the presence of ILs in separation media. There is also a possibility for a complex formation between the solute and the electrolyte which alters the mobility of the solute. A selected application of separations of phenols and aromatic acids will be discussed.  相似文献   

9.
Matsunaga H  Haginaka J 《Electrophoresis》2001,22(15):3251-3256
Separations of basic drug enantiomers by capillary electrophoresis (CE) using ovoglycoprotein (OGCHI) as a chiral selector are described. The effects of running buffer pH and 2-propanol content on the migration times and resolution of basic drug enantiomers were examined using a linear polyacrylamide-coated capillary. High resolution of basic drug enantiomers was attained using a mixture of 50 mM sodium phosphate buffer (pH 4.5-6.0) and 2-propanol (5-30%) including 50 microM OGCHI. It was found that ionic and hydrophobic interactions could work for the recognition of basic drug enantiomers. Further, we compared the chiral resolution ability of OGCHI with that of completely deglycosylated OGCHI (cd-OGCHI) using them as chiral selectors in CE. OGCHI showed higher resolution for basic drug enantiomers tested than cd-OGCHI. The results suggest that the chiral recognition site(s) for OGCHI exists on the protein domain of OGCHI.  相似文献   

10.
Contactless conductivity detection is successfully demonstrated for the enantiomeric separation of basic drugs and amino acids in capillary electrophoresis (CE). Derivatization of the compounds or the addition of a visualization agent as for indirect optical detection schemes were not needed. Non-charged chiral selectors were employed, hydroxypropylated cyclodextrin (CD) for the more lipophilic basic drugs and 18-crown-6-tetracarboxylic acid (18C6H4) for the amino acids. Acidic buffer solutions based on lactic or citric acid were used. The detection limits were determined as 0.3 microM for pseudoephedrine as an example of a basic drug and were in the range from 2.5 to 20 microM for the amino acids.  相似文献   

11.
A great interest has been drawn these last years towards ionic liquids in analytical chemistry, especially for separation methods. Recent synthesis of chiral ILs opened the way of the evaluation of new potential selectors for enantiomeric separations. This work focused on the evaluation of two chiral ILs (ethyl- and phenylcholine of bis(trifluoromethylsulfonyl)imide) by CE. Particular selectivities are awaited by exploiting unique ion-ion or ion-dipole interactions and by tailoring the nature of the cation and the anion. To evaluate such phenomena, a study was carried out with anti-inflammatory drugs 2-arylpropionic acids as model compounds. The results show that these chiral ILs did not present direct enantioselectivity with regard to these model analytes. The influence of chiral ILs in the electrolytes was then studied in the presence of classical chiral selectors (di- or trimethyl-beta-cyclodextrin). Although no general trend could be established, an increase in separation selectivity and resolution was observed in some cases, suggesting synergistic effects. The complementary determination of apparent inclusion constant values of these IL cations in the used cyclodextrins by affinity CE provided support to the understanding of the phenomena involved.  相似文献   

12.
In the current work, two eco‐friendly analytical methods based on capillary electrophoresis (CE) and reversed phase liquid chromatography (RPLC) were developed for simultaneous determination of the most commonly used anticancer drugs for Hodgkin's disease: methotrexate (MTX), vinblastine, chlorambucil and dacarbazine. A background electrolyte (BGE) of 12.5 mmol/L phosphate buffer at pH 7.4 and 0.1 µmol/L 1‐butyl‐3‐methyl imidazolium bromide (BMImBr) ionic liquid (IL) was used for CE measurements at 250 nm detection wavelength, 20 kV applied voltage and 25 °C. The rinsing protocol was significantly improved to reduce the adsorption of IL on the interior surface of capillary. Moreover, RPLC method was developed on α‐1‐acid glycoprotein (AGP) column. Mobile phase was 10 mmol/L phosphate buffer at pH 6.0 (100% v/v) and flow rate at 0.1 mL/min. As AGP is a chiral column, it was successfully separated l ‐MTX from its enantiomer impurity d ‐MTX. Good linearity of quantitative analysis was achieved with coefficients of determinations (r2) >0.995. The stability of drugs measurements was investigated with adequate recoveries up to 24 h storage time under ambient temperature. The limits of detection were <50 and 90 ng/mL by CE and RPLC, respectively. The using of short‐chain IL as an additive in BGE achieved 600‐fold sensitivity enhancement compared with conventional Capillary Zone Electrophoresis (CZE). Therefore, for the first time, the proposed methods were successfully applied to determine simultaneously the analytes in human plasma and urine samples at clinically relevant concentrations with fast and simple pretreatments. Developed IL‐assisted CE and RPLC methods were also applied to measure MTX levels in patients’ samples over time. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
A total of 26 different cyclodextrin (CD) derivatives with different functional groups and degrees of substitution were tested against 35 basic pharmaceutical compounds in an effort to investigate their effectiveness as chiral selectors for enantiomeric separation in capillary electrophoresis (CE). Testing was performed under the same conditions using a low pH buffer (25 mM phosphate buffer at pH approximately 2.5). Five CD derivatives, namely, highly sulfated-beta-CD, highly sulfated-beta-CD, hydroxypropyl-beta-CD (degree of substitution approximately 1), heptakis-(2,6-O-dimethyl)-beta-CD, and heptakis(2,3,6-O-trimethyl)-beta-CD were identified to be most effective for enantiomeric separations and have a wide range of enantiomeric selectivity towards the model compounds. Over 90% of the model compounds were enantiomerically resolved with the five identified CD derivatives, at a minimum resolution of 0.5. An additional 20 compounds were also tested to demonstrate the validity of the identified CD derivatives. The five CD derivatives were recommended as the starting chiral selectors in developing enantiomeric separation methods by CE.  相似文献   

14.
程燕  白敏  王新梅  明永飞  尤进茂 《色谱》2006,24(2):188-191
以咔唑-9-乙基氯甲酸酯(CEOC)作为柱前衍生试剂,采用毛细管电泳对14种二肽进行了手性拆分。以5种二肽为代表,考察了缓冲液种类、浓度、pH值、二元手性选择剂的组合配比等因素对二肽的拆分效果,优化了实验条件。在各自的优化条件下,14种二肽手性拆分的分离度均在3.63以上,最高分离度可达43.14(Gly-Ala)。  相似文献   

15.
A single enzyme treatment with alpha-amylase, prior to the quantification of added folic acid (FA) in fortified instant fried Asian noodles with analysis performed by capillary zone electrophoresis (CZE) and reversed-phase high performance liquid chromatography (RP-HPLC) with UV detection, is described. The method was validated and optimized for capillary electrophoresis (CE) with separation achieved using a 8 mM phosphate-12 mM borate run buffer with 5% MeOH at pH 9.5. FA was well separated from matrix components with nicotinic acid (NA) employed as an internal standard. In a comparative study, separation of FA was performed using HPLC with a mobile phase consisting of 27% MeOH (v/v) in aqueous potassium phosphate buffer (3.5 mM KH(2)PO(4) and 3.2 mM K(2)HPO(4)), pH 8.5, and containing 5 mM tetrabutylammonium dihydrogen phosphate as an ion-pairing agent. For both methods, excellent results were obtained for various analytical parameters including linearity, accuracy and precision. The limit of detection was calculated to be 2.2 mg/L for CE without sample stacking and 0.10 mg/L with high performance liquid chromatography (HPLC). Sample extraction involved homogenization and enzymatic extraction with alpha-amylase. Results indicated that FA was stable during four main stages of instant fried noodle manufacturing (dough crumbs, cut sheets, steaming and frying).  相似文献   

16.
Tao Yu  Yingxiang Du  Bin Chen 《Electrophoresis》2011,32(14):1898-1905
Nowadays, macrocyclic antibiotics are presenting an increasing number of enantioseparation applications. The macrocyclic antibiotics used as chiral selectors in capillary electrophoresis (CE) include the ansamycins and the glycopeptides. The macrolides, another important class of macrocyclic antibiotics, have been reported as a new type of chiral selectors recently. In this study, clarithromycin lactobionate (CL), belonging to the group of macrolide antibiotics, was first investigated for its potential as a novel chiral selector in CE for enantiomeric separation of several basic drugs. As observed, CL allowed excellent separation of the enantiomers of metoprolol, atenolol, propranolol, bisoprolol, esmolol, ritodrine, and amlodipine, as well as partial enantioresolution of labetalol and nefopam. In addition, CL possesses advantages such as high solubility and low viscosity in the solvent and very weak UV absorption. In the course of this study, it was found that both migration times and enantioseparation of the basic drugs were influenced by several experimental parameters, e.g. selector concentration, the composition and pH of the BGE, the type and concentration of organic modifier, and applied voltage. Thus, the effects of these factors were systematically investigated, and satisfactory enantioseparations of the studied drugs were achieved at the buffer pH range of 7.3–7.5 using 12.5 mM borax buffer with 50% v/v methanol, 60 mM CL, and 20 kV applied voltage. Moreover, comparison of the influences of the studied parameters was further investigated by means of Statistical Product and Service Solutions (SPSS) in this article.  相似文献   

17.
郝颖  王荣  尹强  谢华  李文斌  贾正平 《色谱》2013,31(10):1005-1009
胃癌是临床常见的恶性肿瘤之一。近年来寻找肿瘤相关特异蛋白质是蛋白质组学研究的热点。本文通过考察毛细管动态涂层方法、筛分介质聚环氧乙烷(PEO)的浓度、缓冲液的pH值、分离电压、温度及荧光染料对分离效果的影响,建立了毛细管电泳-激光诱导荧光法分离胃癌组织及癌旁正常组织蛋白质的方法;通过分离检测,获得两者的蛋白质指纹图谱。经分析,两者的指纹图谱相似度达到0.8以上,差异蛋白质分子质量集中在50000~100000 Da之间,提示某些小分子蛋白质可能是和肿瘤发生相关的特异蛋白质,从而缩小了特异性分子标记物的筛选范围。病理组织学分型及蛋白质电泳峰数目的统计结果验证了该方法的可靠性。该方法具有临床应用的潜力。  相似文献   

18.
邹晓莉  黎源倩  毛红霞  曾红燕 《色谱》2005,23(3):264-266
建立了消毒剂中活性成分醋酸氯己定(又名:醋酸洗必泰)的毛细管电泳快速检测法。采用15 mmol/L磷酸盐-乙腈( 体积比为60∶40)缓冲体系,将醋酸氯己定在50 cm×75 μm i.d.的石英毛细管柱中进行电泳分离,电泳电压为15 kV,检 测波长为254 nm。同时,对毛细管电泳分析醋酸氯己定的条件(如缓冲液的种类、pH值、浓度及电泳电压等)进行了优化 。用该方法对消毒剂样品进行测定,在4 min内可完成分析。醋酸氯己定在质量浓度为0.01~0.10 g/L时线性良好,检测 限为0.004 mg/L,吸光度值的相对标准偏差为3.97%,迁移时间的相对标准偏差为2.99%,样品加标回收率为91.4%~116.6%。将该方法 与高效液相色谱法进行比较,两种方法测定结果的相对误差≤4%。所建立的检测醋酸氯己定含量的毛细管区带电泳法简单 、快速,适用于消毒剂样品的测定。  相似文献   

19.
A systematic approach to enantiomeric separations in capillary electrophoresis (CE) and liquid chromatography (LC) with chiral mobile phase additives (MPA) or a chiral stationary phase (CSP) is used in the study of fluoxetine and norfluoxetine with cyclodextrins as chiral selectors. Binding constants and selectivities are determined under the same experimental conditions (mobile phase, buffer composition). Good agreement is found between results from the three techniques. The role of the buffer salt is investigated by comparison of binding constants obtained with triethylammonium and sodium acetate buffers.

Investigation of the effects of derivatisation of the selector in CE and LC with MPA demonstrates the appropriate choice of cyclodextrin type for use in LC. By studying the influence of organic modifier content on separation parameters, CE can predict a useful solvent working range for a CSP.  相似文献   


20.
Determination of impurities in ionic liquids (ILs) remains a difficult task. In this work, the hyphenation of isotachophoretic (ITP) preconcentration to zone electrophoresis (ZE) has been explored for the trace analysis of the cationic impurities Na(+), Li(+), and methylimidazolium (MI(+)) in butylmethylimidazolium (BMI(+))-based ILs. Simultaneous detection of UV-transparent and UV-absorbing impurities was ensured by a BGE composed of creatinine-acetate buffer. To induce ITP, three different strategies were evaluated: (i) Sample self-stacking ensured by the addition of ammonium acetate (NH(4)Ac) to 25-50-fold diluted IL solution (transient ITP). (ii) Complete ITP-ZE separation performed in a single capillary: ITP was realized in discontinuous electrolytes comprising an 80 mM NH(4)Ac, 40 mM acetic acid, 30 mM alpha-CD, pH 5.05, leading electrolyte (LE) and a 10 mM creatinine, 10 mM acetic acid, pH 4.9, terminating electrolyte (TE). To create the ZE stage, the ITP stack of analytes was moved back toward the capillary inlet by pressure and simultaneously the capillary was filled with the BGE. This protocol made it possible to accommodate a 2.5-times diluted IL sample. (iii) Complete counterflow ITP-ZE with continuous electrokinetic sample supply: the ITP stage was performed in a capillary filled with a 150 mM NH(4)Ac, 75 mM acetic acid, 30 mM alpha-CD, pH 5.0 LE, with 40-times diluted IL at the capillary inlet. BMI(+) from IL acts as the terminating ion. The LODs reached in this latter case were at the 10 and 1 ppb levels for MI(+) and Li(+) in diluted IL matrix, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号