首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

To test a magnetic resonance image (MRI) technique that uses an additional pulse in multi-echo T2* sequence that works to suppress the fat signal, in subjects with liver iron overload and concomitant presence of fat in the liver, which have been revealed as a major drawback that compromises the correct iron quantification by MRI.

Materials and Methods

Fifty magnetic resonance images of the liver (1.5 T scanner) of individuals with blood ferritin increases were retrospectively reviewed for the presence of steatosis, using the sequence in and out of phase, and iron overloading, using two sequences T2 * multi-echo: one standard and other with additional fat suppression pulse. T2 * values and their standard deviations were analyzed statistically.

Results

Our results showed that a significantly lower standard deviation of T2* values is obtained when the fat saturation pulse is applied in patients with steatosis. We found that modulation of fat signal on liver iron overload resulted in a different categorization of some patients. In one case, the patient was re-classified within normal levels of liver iron.

Conclusion

Our findings may contribute to a better measure of liver iron overload with relevant implications for patient treatment and care.  相似文献   

2.
This study assesses the stability of magnetic resonance liver fat measurements against changes in T2* due to the presence of iron, which is a confound for accurate quantification. The liver T2* was experimentally shortened by intravenous infusion of a super paramagnetic iron oxide contrast agent. Low flip angle multiecho gradient echo sequences were performed before, during and after infusion. The liver fat fraction (FF) was calculated in co-localized regions-of-interest using T2* models that assumed no decay, monoexponential decay and biexponential decay. Results show that, when T2* was neglected, there was a strong underestimation of FF and with monoexponential decay there was a weak overestimation of FF. Curve-fitting using the biexponential decay was found to be problematic. The overestimation of FF may be due to remaining deficiencies in the model, although is unlikely to be important for clinical diagnosis of steatosis.  相似文献   

3.

Purpose

To investigate the correlation between perfusion-related parameters obtained with intravoxel incoherent motion (IVIM) and classical perfusion parameters obtained with dynamic contrast-enhanced (DCE) magnetic resonance imaging in patients with head and neck squamous cell carcinoma (HNSCC), and to compare direct and asymptotic fitting, the pixel-by-pixel approach, and a region of interest (ROI)-based approach respectively for IVIM parameter calculation.

Materials and methods

Seventeen patients with HNSCC were included in this retrospective study. All magnetic resonance (MR) scanning was performed using a 3 T MR unit. Acquisition of IVIM was performed using single-shot spin-echo echo-planar imaging with three orthogonal gradients with 12 b-values (0, 10, 20, 30, 50, 80, 100, 200, 400, 800, 1000, and 2000). Perfusion-related parameters of perfusion fraction ‘f’ and the pseudo-diffusion coefficient ‘D*’ were calculated from IVIM data by using least square fitting with the two fitting methods of direct and asymptotic fitting, respectively. DCE perfusion was performed in a total of 64 dynamic phases with a 3.2-s phase interval. The two-compartment exchange model was used for the quantification of tumor blood volume (TBV) and tumor blood flow (TBF). Each tumor was delineated with a polygonal ROI for the calculation of f, f ? D* performed using both the pixel-by-pixel approach and the ROI-based approach. In the pixel-by-pixel approach, after fitting each pixel to obtain f, f ? D* maps, the mean value in the delineated ROI on these maps was calculated. In the ROI-based approach, the mean value of signal intensity was calculated within the ROI for each b-value in IVIM images, and then fitting was performed using these values. Correlations between f in a total of four combinations (direct or asymptotic fitting and pixel-by-pixel or ROI-based approach) and TBV were respectively analyzed using Pearson's correlation coefficients. Correlations between f ? D* and TBF were also similarly analyzed.

Results

In all combinations of f and TBV, f ? D* and TBF, there was a significant correlation. In the comparison of f and TBV, a moderate correlation was observed only between f obtained by direct fitting with the pixel-by-pixel approach, whereas a good correlation was observed in the comparisons using the other three combinations. In the comparison of f ? D* and TBF, a good correlation was observed only with f ? D* obtained by asymptotic fitting with the ROI-based approach. In contrast, moderate correlations were observed in the comparisons using the other three combinations.

Conclusion

IVIM was found to be feasible for the analysis of perfusion-related parameters in patients with HNSCC. Especially, the combination of asymptotic fitting with the ROI-based approach was better correlated with DCE perfusion.  相似文献   

4.
Whole-tissue and homogenized samples of human liver were studied in a NMR spectrometer, T1 and T2 relaxation times were measured as a function of added inorganic or organic iron. When inorganic iron (Fe+3) was added, pronounced T1 and T2 shortening was noted. However, when organic iron, in the form of ferritin, was added, the amount of T1 and T2 relaxation enhancement was much reduced for the same amount of added iron. The in vitro ferritin results model the situation found in clinical studies of hemochromatosis. Only in cases of severe iron overload were significant decreases in relaxation times observed. The T2 relaxation time was the more reliable indicator of excessive levels of iron in the liver. The large range of T1 and T2 values encountered in normal volunteers precludes the use of MR to quantitatively measure iron levels in the liver. The T1 and T2 relaxation times measured at intervals for one individual tend to fluctuate as well, making the use of MR to follow the course of treatment of iron overload disorders unreliable.  相似文献   

5.
Multiple sclerosis (MS) causes demyelinating lesions in the white matter and increased iron deposition in the subcortical gray matter. Myelin protons have an extremely short T2* (< 1 ms) and are not directly detected with conventional clinical magnetic resonance (MR) imaging sequences. Iron deposition also reduces T2*, leading to reduced signal on clinical sequences. In this study we tested the hypothesis that the inversion recovery ultrashort echo time (IR-UTE) pulse sequence can directly and simultaneously image myelin and iron deposition using a clinical 3 T scanner. The technique was first validated on a synthetic myelin phantom (myelin powder in D2O) and a Feridex iron phantom. This was followed by studies of cadaveric MS specimens, healthy volunteers and MS patients. UTE imaging of the synthetic myelin phantom showed an excellent bi-component signal decay with two populations of protons, one with a T2* of 1.2 ms (residual water protons) and the other with a T2* of 290 μs (myelin protons). IR-UTE imaging shows sensitivity to a wide range of iron concentrations from 0.5 to ~ 30 mM. The IR-UTE signal from white matter of the brain of healthy volunteers shows a rapid signal decay with a short T2* of ~ 300 μs, consistent with the T2* values of myelin protons in the synthetic myelin phantom. IR-UTE imaging in MS brain specimens and patients showed multiple white matter lesions as well as areas of high signal in subcortical gray matter. This in specimens corresponded in position to Perl's diaminobenzide staining results, consistent with increased iron deposition. IR-UTE imaging simultaneously detects lesions with myelin loss in the white matter and iron deposition in the gray matter.  相似文献   

6.
T2* measurements in human brain at 1.5, 3 and 7 T   总被引:1,自引:0,他引:1  
Measurements have been carried out in six subjects at magnetic fields of 1.5, 3 and 7 T, with the aim of characterizing the variation of T2* with field strength in human brain. Accurate measurement of T2* in the presence of macroscopic magnetic field inhomogeneity is problematic due to signal decay resulting from through-slice dephasing. The approach employed here allowed the signal decay due to through-slice dephasing to be characterized and removed from data, thus facilitating an accurate measurement of T2* even at ultrahigh field. Using double inversion recovery turbo spin-echo images for tissue classification, an analysis of T2* relaxation times in cortical grey matter and white matter was carried out, along with an evaluation of the variation of T2* with field strength in the caudate nucleus and putamen. The results show an approximately linear increase in relaxation rate R2* with field strength for all tissues, leading to a greater range of relaxation times across tissue types at 7 T that can be exploited in high-resolution T2*-weighted imaging.  相似文献   

7.

Background

The goal of the study was to assess a T2*-weighted MRI sequence for the ability to identify hepatocellular carcinoma (HCC).

Methods

Hepatic iron deposition, which is common in chronic liver disease (CLD), may increase the conspicuity of HCC on GRE imaging due to increased T2* signal decay in liver parenchyma. In this study, a breath-hold T2*-weighted MRI sequence was evaluated by a blinded observer for HCC and the results compared to a reference standard of gadolinium-enhanced MRI in these same patients. Forty-one patients (mean age 56.2 years; 17 females) were included in this approved, retrospective study.

Results

By the reference standard, 14 of 41 patients had a total of 25 HCCs. The sensitivity of the T2*-weighted MR sequence for identifying HCC, per lesion, was 60%, while the specificity was 100%. There was a significantly lower T2* value of liver parenchyma in patients with HCC identified by the T2*-weighted sequence than in those with HCCs which were not identified by the T2*-weighted sequence (27.8±2.2 vs. 21.9±2.1 ms; P=.02).

Conclusions

A T2*-weighted MRI sequence can identify HCC in patients with CLD. This technique may be beneficial for imaging of patients contraindicated for gadolinium.  相似文献   

8.
We retrospectively reviewed the MR studies on all patients with liver-related fluid collections compatible with acute or early subacute hemorrhage, who underwent MR imaging at our center between June 1994 and January 1998. All patients had a clinical history of an underlying liver lesion or injury with a duration of symptomatology of less than 5 days. In three patients with only 2-3 days of symptoms, the liver-related hemorrhagic fluid was hypointense on T1-weighted images and markedly hypointense on T2-weighted images relative to liver, consistent with intracellular deoxyhemoglobin. The fluid was relatively homogeneous in signal intensity. In three patients with 3-5 days of symptoms, the majority of liver-related fluid was hyperintense on T1-weighted images and hypointense on T2-weighted images relative to liver, consistent with intracellular methemoglobin. Three of these latter four patients also had fluid collections of varying T1-and T2-weighted signal intensity consistent with blood breakdown products of varying ages. Clinical findings matched the MR findings of acute/early subacute blood in all cases. Our results describe the findings of acute and early subacute liver hemorrhage. The most helpful MR feature of bleeding of recent origin is very low signal intensity of the fluid on T2-weighted imaging.  相似文献   

9.
We compared the effects of two superparamagnetic iron oxide (SPIO) contrast agents, ferumoxides and SHU-555A, in MR imaging of the liver and spleen. Thirty-six patients with known malignant lesions of the liver underwent T2W turbo spin-echo (TSE) and T1WGRE FLASH opposed-phase imaging before and after SPIO injection on a 1.0 T MR system. Post-ferumoxides images were obtained in 18 patients 90 min after infusion of 15 micrommol Fe/kg of the agent. In 18 other patients SHU-555A was administered as a rapid bolus at a dose of 7.0-12.9 micrommol Fe/kg. T1WGRE FLASH images were obtained immediately, 30 s and 480 s and T2WTSE images 10 min after injection. Signal intensity of the liver, spleen, and malignant liver lesions before and after SPIO was measured with operator-defined regions of interest. The effects of ferumoxides and SHU-555A were measured as the percentage signal intensity change (PSIC) and in the malignant liver lesions additionally as changes in lesion-to-liver contrast-to-noise ratio (deltaDCNR). On T2W TSE images, there was no significant difference between the two agents in signal loss of liver parenchyma (p > 0.05). The signal loss in the spleen produced by ferumoxides was greater than with SHU-555A (p < 0.05). Both SPIO agents produced a significant increase in the CNR of malignant liver lesions. Delta CNR was slightly greater with ferumoxides than with SHU-555A (p < 0.05). On T1WGRE FLASH images, a slight decrease of liver SI induced by both agents was found on late post-SPIO images. No significant difference of liver PSIC between the two SPIO agents was noted on T1W images. The SI of spleen was significantly increased with both agents on T1W images and no difference in PSIC of spleen was noted (p > 0.05). The T1 and T2 effects produced by ferumoxides and SHU-555A were comparable in the liver although ferumoxides produced a stronger T2 effect in the spleen.  相似文献   

10.
ObjectivesAceruloplasminemia (ACP) is a rare autosomal recessive disorder characterized by intracranial and visceral iron overload. With R2*-based imaging or quantitative susceptibility mapping (QSM), it is feasible to measure iron in the brain quantitatively, although to date this has not yet been done for patients with ACP. The aim of this study was to provide quantitative iron measurements for each affected brain region in an ACP patient with the potential to do so in all future ACP patients. This may shed light on the link between brain iron metabolism and the territories affected by ceruloplasmin function.MethodsWe imaged a patient with ACP using a 3T magnetic resonance imaging scanner with a fifteen-channel head coil. We manually demarcated gray matter and white matter on the Strategically Acquired Gradient Echo (STAGE) images, and calculated values for susceptibility and R2* in these regions. Correlation analysis was performed between the R2* values and the susceptibility values.ResultsBesides the usual territories affected in ACP, we also discovered that the mammillary bodies and the lateral habenulae had significant increases in iron, and the hippocampus was severely affected both in terms of iron content and abnormal tissue signal. We also noted that the iron in the cortical gray matter appeared to be deposited in the inner layers. Moreover, several pathways between the superior colliculus and the pulvinar thalamus, between the caudate and putamen anteriorly and between the caudate and pulvinar thalamus posteriorly were also evident. Finally, R2* correlated strongly with the QSM data (R2 = 0.67, t = 6.78, p < 0.001).ConclusionQSM and R2* have proven to be sensitive and quantitative means by which to measure iron content in the brain. Our findings included several newly noted affected brain regions of iron overload and provided some new aspects of iron metabolism in ACP that may be further applicable to other pathologic conditions. Furthermore, our study may pave the way for assessing efficacy of iron chelation therapy in these patients and for other common iron related neurodegenerative disorders.  相似文献   

11.
Currently, serum ferritin concentration is the best noninvasive estimator of liver iron content. This study investigated the ability of magnetic resonance imaging to determine hepatic iron concentration. Fisher rats were treated with either parenteral iron to increase levels or phlebotomy to lower them and achieved a wide range of liver iron concentrations. Rats were imaged using a clinical whole body scanner at 1.5 Tesla with a 15-cm Helmholtz surface coil and a 23-cm field of view. The ratio of signal intensity of liver to skeletal muscle from images of the live intact rats correlated well with chemically measured iron concentration of the liver (r = −.89, p < .0001, linear regression analysis). Transverse relaxation rates (1/calculated T2 relaxation times) also correlated with liver iron content (r = .66, p < .0001). The observation of a significant correlation between liver iron content and both signal intensities and T2 relaxation rates, obtained by magnetic resonance imaging, may have considerable clinical relevance. If adapted to humans, this technique would have obvious applications in the diagnosis and management of diseases associated with iron overload as well as in the investigation of the overall role of iron in various human liver diseases.  相似文献   

12.

Purpose

The aim of this study was to determine the adequate MR sequence for the lesion conspicuity of hepatocellular lesions with increased iron uptake on superparamagnetic iron oxide (SPIO)-enhanced MRI.

Materials and Methods

SPIO-enhanced MRI was performed using a 1.5-T system. Among 25 patients with hypovascular hepatocellular nodules on contrast-enhanced dynamic CT (no early enhancement at arterial phase and hypoattenuation at equilibrium phase), 39 lesions with increased iron uptake on SPIO-enhanced MRI were evaluated. SPIO-enhanced MRI included (1) T1-weighted in-phase gradient recalled echo (GRE) images, (2) T2-weighted fast spin echo (FSE) images, (3) T2*-weighted GRE with moderate TE (7 ms) and (4) long TE (12 ms). The lesion-to-liver contrast-to-noise ratios of the hepatocellular nodule and the signal-to-noise ratio (SNR) of the hepatic parenchyma were calculated by one radiologist for a quantitative assessment. MR images were reviewed retrospectively by two independent radiologists to compare the subjective lesion conspicuity in each image set based on a four-point rating scale.

Result

The mean lesion-to-liver contrast-to-noise ratios with T2*-weighted GRE with moderate TE (7 ms) was highest (5.79±3.71) and was significantly higher than those with T1-weighted, in-phase images (3.79±3.23, P<.01), T2-weighted images (2.72±1.52, P<.001) and T2*-weighted GRE with long TE (12 ms) (3.93±2.69, P<.05). The subjective rating of lesion conspicuity was best on the T2*-weighted GRE with moderate TE (7 ms), followed by that on the T2*-weighted GRE with moderate TE (7 ms; P<.05).

Conclusion

T2*-weighted GRE sequence with moderate TE (7 ms) showed high lesion-to-liver contrast-to-noise ratios in hepatocellular lesions with increased iron uptake on SPIO-enhanced MRI, indicating better lesion conspicuity of hypointense hepatocellular nodules in cirrhosis or chronic hepatitis.  相似文献   

13.
Sodium T2*-weighted MR imaging of acute focal cerebral ischemia in rabbits   总被引:2,自引:0,他引:2  
Changes in T2*-weighted tissue sodium (23Na) signal following acute ischemia may help to identify necrotic tissue and estimate the duration of ischemia. Sodium signal was monitored in a rabbit model of acute (0-4 h) focal cerebral ischemia, using gradient echo 23Na MR images (echo time = 3.2 ms) acquired continuously in 20-min intervals on a 4-Tesla MRI. 2,3,5-Triphenyl-tetrazolium chloride staining was used to identify regions of necrosis. In necrotic tissue, average 23Na image signal intensity decreased by 11% +/- 8% during the first 40 min of ischemia followed by a linear increase (0.19%/min) to 25% +/- 14% greater than baseline after 4 h of ischemia. The time course of 23Na signal change observed in necrotic tissue following focal ischemia in this rabbit model is consistent with an initial decrease in 23Na T2* relaxation time followed by an increase in tissue sodium concentration and provides further evidence that tissue 23Na signal may offer unique information regarding tissue viability that is complementary to other MR imaging techniques.  相似文献   

14.
A bi-exponential proton transverse relaxation rate (R(2)) image analysis technique has been developed that enables the discrimination of dual compartment transverse relaxation behavior in systems with rapid transverse relaxation enhancement. The technique is particularly well suited to single spin-echo imaging studies where a limited number of images are available for analysis. The bi-exponential R(2) image analysis is facilitated by estimation of the initial proton spin density signal within the region of interest weighted by the RF field intensities. The RF field intensity-weighted spin density map is computed by solving a boundary value problem presented by a high spin density, long T(2) material encompassing the region for analysis. The accuracy of the bi-exponential R(2) image analysis technique is demonstrated on a simulated dual compartment manganese chloride phantom system with relaxation rates and relative population densities between the two compartments similar to the bi-exponential transverse relaxation behavior expected of iron loaded liver. Results from analysis of the phantoms illustrate the potential of bi-exponential R(2) image analysis with RF field intensity-weighted spin density projection for quantifying transverse relaxation enhancement as it occurs in liver iron overload.  相似文献   

15.
Relaxation effects in the quantification of fat using gradient echo imaging   总被引:4,自引:0,他引:4  
Quantification of fat has been investigated using images acquired from multiple gradient echoes. The evolution of the signal with echo time and flip angle was measured in phantoms of known fat and water composition and in 21 research subjects with fatty liver. Data were compared to different models of the signal equation, in which each model makes different assumptions about the T1 and/or T2* relaxation effects. A range of T1, T2*, fat fraction and number of echoes was investigated to cover situations of relevance to clinical imaging. Results indicate that quantification is most accurate at low flip angles (to minimize T1 effects) with a small number of echoes (to minimize spectral broadening effects). At short echo times, the spectral broadening effects manifest as a short apparent T2 for the fat component.  相似文献   

16.
Short TI inversion-recovery (STIR) imaging provides specific advantages over standard spin-echo (SE) MR sequences by producing additive effects of T1 and T2 brightening of pathology and suppression of the signal from surrounding fat. We retrospectively evaluated 12 patients with abnormalities, primarily neoplastic, of the porta hepatis/hepatoduodenal ligament (PH/HdL) with CT and MR imaging, including SE and STIR imaging. Masses on CT were of slightly decreased density compared to liver and seen in contrast to surrounding fat in the PH/HdL region. On MR, T1-weighted images provided comparable anatomic detail to CT, with masses clearly distinguished from surrounding fat due to the low signal intensity of masses as compared to fat. T2-weighted images clearly depicted intrahepatic lesions because of their high signal intensity relative to liver. Increased signal in extrahepatic lesions made them less distinctly seen from surrounding fat. STIR images best demonstrated tumor relative to fat. In six cases, CT was equivalent in demonstrating pathology to the best MR sequence. At least one MR sequence demonstrated pathology better than CT in 6 of 12 cases. In five of these six cases, the STIR sequence was better than CT. Thus, MR, particularly STIR imaging, provides a useful technique in imaging of PH/HdL pathology.  相似文献   

17.
The purpose of this study was to evaluate the potential of superparamagnetic iron oxide particles (SPIO) as tissue specific contrast agent in magnetic resonance (MR) imaging in detection and characterization of focal hepatic lesions. We investigated 45 patients with focal hepatic lesions. T1-weighted SE (TR 650/TE 15 ms) and T2-weighted SE (TR 2015-2030/TE 45 and 90 ms) unenhanced images were obtained. After SPIO application we performed T1-weighted images with and T2-weighted images with and without fat suppression using the same image parameters. Liver signal intensity decreased by 74% (min 47%, max 83%) on T2-weighted images after application of the contrast agent. Benign lesions (FNH, adenoma) showed an average signal drop of 40% (min 20%, max 47%) whereas malignant lesions showed no significant change of signal intensity on post-contrast images. The mean tumor-to-liver contrast-to-noise ratio (C/N) was improved in all post-contrast sequences irrespective of the lesion type. An additional increase of tumor-to-liver contrast by use of fat suppression technique could be established in the slightly T2-weighted sequence (TE 45 ms). In metastases, divided in different size groups, we could determine a significant size relation of tumor-to-liver C/N. After SPIO application the number of detected lesions increased distinctly, especially small foci are more easily demonstrated. SPIO particles are a efficacious contrast agent for MR examinations of the liver. For tumor characterization T1- and T2-weighted pre- and post-contrast images are necessary. The T1-weighted sequences are helpful to differentiate benign lesions such as cysts and hemangiomas from malignant lesions. Detection and differential diagnoses of hepatic lesions are improved by use of the SPIO-particles.  相似文献   

18.
The purpose of our study was to determine the MR imaging appearance of exophytic benign liver tumors on precontrast and postgadolinium images. We reviewed our 9.5 year experience with MRI of the liver with dynamic gadolinium enhanced imaging to identify four patients with five histologically proven exophytic benign liver tumors. The histological diagnoses were cavernous hemangioma (2), focal nodular hyperplasia (FNH) (1), and hepatocellular adenoma (HCA) (2 exophytic adenomas in a patient with adenomatosis of the liver). All MRI studies were performed at 1.5 T and included: in-phase and out-of-phase T1-weighted spoiled gradient echo (SGE), T2-weighted fat-suppressed echo train spin echo, single shot T2-weighted sequences, and serial postgadolinium T1-weighted SGE sequences without and with fat-suppression. Prospective interpretations were reviewed and retrospective consensus readings of all MR images were performed assessing location, size, origin, morphology, visibility of the connection to the liver, signal characteristics on precontrast T1-weighted and T2-weighted images, and enhancement patterns on serial postgadolinium images. Three of the five tumors were pedunculated and connected to the liver by a thin stalk, which was prospectively identified in one patient. On precontrast and serial postgadolinium images, all exophytic tumors showed signal characteristics comparable to imaging features of standard intraparenchymal benign liver tumors. Our findings illustrate that the characteristic T1, T2, and postgadolinium imaging findings of these tumors permit correct identification of their liver origin despite their exophytic location, even if their connection with liver is not visualized.  相似文献   

19.
Clinical applications of blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) depend heavily on robust paradigms, imaging methods and analysis procedures. In this work, as a means to optimize and perform quality assurance of the entire imaging and analysis chain, a phantom that provides a well known and reproducible signal change similar to a block type fMRI experiment is presented. It consists of two gel compartments with slightly different T2 that dynamically enter and leave the imaged volume. The homogeneous gel in combination with a cylindrical geometry results in a well-defined T*2 difference causing a signal difference between the two compartments in T*2-weighted MR images. From time series data obtained with the phantom, maps of percent signal change (PSC) and t-values are calculated. As an example of image parameter optimisation, the phantom is demonstrated to be useful for accurate determination of the influence of echo time (TE) on BOLD fMRI results, taking the t-value as a measure of sensitivity. In addition, the phantom is proposed as a tool for quality assurance (QA) since reproducible time series and t-maps are obtained in a series of independent repeat experiments. The phantom is relatively simple to build and can therefore be used by any clinical fMRI center.  相似文献   

20.
T2-weighted images are considered the most sensitive for lesion detection at high field; however, long imaging time is problematic. Accordingly, the authors compared four breath-hold T2 or T2* weighted sequences comprising T2*-weighted FLASH, T2*-weighted PSIF, T2-weighted rapid spin echo (RASE), and T2-weighted Turbo-FLASH (Turbo) in 20 different healthy volunteers, 10 at 1.0 T and 10 at 1.5 T with reference to regular T2-weighted spin echo. Images were evaluated quantitatively by liver signal to noise (S/N) and spleen-liver signal difference to noise (SD/N) ratios and qualitatively for presence of artifacts and image quality. Data were evaluated for 1.0 T and 1.5 T separately and combined. In the combined evaluation, T2*-FLASH had good S/N (23.1 + 5.1) but low SD/N (2.9 + 1.7) and suffered from susceptibility artifacts. T2* PSIF had good S/N (28.1 + 10.0) and moderate SD/N (6.0 + 2.4), but occasionally had heterogeneous signal intensity. Flow signal void was an attractive feature. T2 RASE had very low S/N (4.4 + 1.9) and low SD/N (2.3 + 1.1) and suffered from flow artifacts. T2-Turbo had good S/N (24.6 + 8.6) and SD/N (8.9 + 2.5). Flow signal void was present, but small matrix size decreased image quality. The results of our study suggest that T2*-PSIF and T2-Turbo have good S/N and SD/N and fair image quality which may be clinically useful for breath-hold T2-weighted sequences of the liver.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号