首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
利用白光干涉技术测量块状材料的群折射率   总被引:1,自引:0,他引:1       下载免费PDF全文
张淑娜  罗震岳  沈伟东  刘旭  章岳光 《物理学报》2011,60(1):14221-014221
对群折射率的精确而快速测量是光学工程领域一个基础而又亟需解决的难题,本文提出了一套光谱型迈克尔逊白光干涉系统的解决方案.该系统充分利用了微型光纤光谱仪一次测量便可获得所有干涉信息的特点,无需机械扫描装置,具有结构简单和测量快速的优点.与传统的窗口傅里叶变换算法相比,本文采用小波变换直接从干涉信号的小波脊中提取群延迟,减小了由相位求导得到群延迟过程中引入的误差放大效应,进而提高了群折射率的测量精度.基于此迈克尔逊白光干涉系统,在不同干涉位置处对两块不同厚度的石英和BK7玻璃进行了测量,实验结果表明此方法在宽 关键词: 白光干涉 群折射率 小波变换 傅里叶变换  相似文献   

2.
In this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherence interferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum of measured signal have made possible to determined relationship between complex refractive index and hematocrit level in human blood.  相似文献   

3.
In this study an alternative method based on surface plasmon resonance is proposed for in-situ monitoring of variation in the refractive index of a test sample. A wavelength-modulated light source and an unequal-path-length optical configuration heterodyne interferometer are used to detect the phase difference change, which can then be used to estimate the change in the refractive index of a test sample. The experimental results demonstrate a phase stability of 0.02°. The resolution power of the refractive index is 1.5 × 10− 6 RIU. This method has several advantages over previously used methods such as simple optical setup, easier operation in real time, and low cost.  相似文献   

4.
张诚平 《光学技术》2000,26(2):153-155
介绍了用准相干干涉法测量光纤群折射率的方法。通过准相干干涉定位 ,用精密光栅数显系统测长 ,由计算机采集并处理数据获得一段短光纤的光学长度 ,然后利用常规精密测长手段测得其几何长度 ,从而得到光纤的群折射率。实验结果及误差分析得出 :测量不确定度优于 7× 10 -5(2σ)。  相似文献   

5.
本文分析和讨论了双波长全息干涉计量的单次曝光法和双曝光法。这两种方法都提供了用可见光得到相当于不可见的长波干涉的结果,其测量灵敏度和测量精度可以通过选择合适的工作波长而能得到调整。  相似文献   

6.
We present a novel needle-based device for the measurement of refractive index and scattering using low-coherence interferometry. Coupled to the sample arm of an optical coherence tomography system, the device detects the scattering response of, and optical path length through, a sample residing in a fixed-width channel. We report use of the device to make near-infrared measurements of tissues and materials with known optical properties. The device could be used to exploit the refractive index variations of tissue for medical and biological diagnostics accessible by needle insertion.  相似文献   

7.
A new method has been proposed for determining the complex refractive index of terahertz surface plasmons. This method implements the concept of asymmetric static interferometry in the planar version, where the interference pattern is formed by surface rather than bulk waves. The information about the real part of the refractive index is carried by the interference pattern period, while its imaginary part can be found from the illumination magnitudes in the pattern extrema. Original Russian Text ? G.D. Bogomolov, G.N. Zhizhin, A.P. Kiryanov, A.K. Nikitin, O.V. Khitrov, 2009, published in Izvestiya Rossiiskoi Akademii Nauk. Seriya Fizicheskaya, 2009, Vol. 73, No. 4, pp. 562–565.  相似文献   

8.
Using the phenomenon of total internal reflection and a beam splitting device, a technique of simultaneous phase-shift interferometry is proposed for measuring the full-field refractive index. Because this method applies a beam splitting device that mimics the characteristics of beam splitting and phase modulation, four interferemetric images of various phase distributions can be simultaneously captured. Therefore, this setup can avoid errors caused by non-simultaneous capturing of images and offers the benefits of high stability, ease of operation, and real-time measurement. Furthermore, using the phenomenon of total internal reflection, the phase difference between p- and s-polarized light varies considerably with the refractive index of a tested specimen. This can substantially increase the measurement resolution. The feasibility of this method is verified using an experiment, and the measurement resolution can be higher than 3.65 × 10−4 RIU.  相似文献   

9.
The absorption contrast image is very low for those weakly absorbing materials or weak phase object, such as the soft biological tissues, however, the phase item value of refractive index is a thousand larger than the absorption item, therefore the refractive index interferometry method is expected to be a new imaging tool for them. An interferometry method based on the X-ray crystallography is explored to the measurement of refractive index in this paper. The theoretical foundation, the optical design, the crystal transistor performance are the key parts to this interferometry method based on the X-ray crystallography. We give out a special refractive index detection scheme, using a laboratory hard X-ray source, and four single Si crystals. With this instrument, refractive index profile of those weak phase object can be unfolded accurately using this method. This refractive index interferometry method based on the X-ray crystallography will provide a new research tool for those special material properties or biological tissues study.  相似文献   

10.
The thermal contribution to the nonlinear refractive index of air at 1.064mum was measured with a high-finesse Fabry-Perot cavity and a 500-mW cw laser beam. At room temperature and pressure, the nonlinear refractive-index coefficient of air was found to be n(2)((th))=(-1.9+/-0.2)x10 (-14) cm(2)/W for a beam waist radius of 0.23 mm and was found to be independent of the relative humidity. The thermal nonlinearities of N(2) , O(2) , and CO(2) were also measured, and it was found that the dominant contribution to air is its O(2) content.  相似文献   

11.
12.
Q Chen  H Luo  S Wang  F Wang 《Optics letters》2012,37(14):2916-2918
A method for refractive index of air measurement is presented based on surface plasmon resonance (SPR) and phase detection using a dual-frequency laser interferometer. Theoretical analyses indicate that the phase-difference variation of the measurement signal versus the reference signal is linear with refractive index of air (RIA) fluctuation, and the calculation formula of RIA is derived. The structure design of the self-adaptive SPR sensor greatly reduces the measurement error resulting from the incident angle shift and improves the sensitivity. The experiments show that measurement uncertainty of 10(-6) order has been achieved when phase detection precision is 0.1°. The phenomenon of sudden phase variation during air pumping and air filling, which is caused by temperature fluctuation, is discussed.  相似文献   

13.
A real-time test method for determining the refractive index distributions of 3-D axisymmetric temperature field around a flame with the use of a photorefractive holographic interferometer is proposed. Some techniques in data processing for improving the quality of resultant interferogram are developed. Experimental results, which show the effectiveness of this method and agree with theoretical expectations, are also given.  相似文献   

14.
Pulsed digital holographic interferometry has been used to investigate the plume and the shock wave generated in the ablation process of a Q-switched Nd-YAG (λ=1064 nm and pulse duration=12 ns) laser pulse on a polycrystalline boron nitride (PCBN) target under atmospheric air pressure. A special setup based on two synchronised wavelengths from the same laser for simultaneous processing and measurement has been used. Digital holograms were recorded for different time delays using collimated laser light (λ=532 nm) passed through the volume along the target. Numerical data of the integrated refractive index field were calculated and presented as phase maps showing the propagation of the shock wave and the plume generated by the process. Radon inversion has been used to estimate the 3D refractive index fields measured from the projections assuming rotational symmetry. The shock wave density has been calculated using the point explosion model and the shock wave condition equation and its behaviour with time at different power densities ranging from 1.4 to 9.1 GW/cm2 is presented. Shock front densities have been calculated from the reconstructed refractive index fields using the Gladstone–Dale equation. A comparison of the shock front density calculated from the reconstructed data and that calculated using the point explosion model at different time delays has been done. The comparison shows quite good agreement between the model and the experimental data. Finally the reconstructed refractive index field has been used to estimate the electron number density distribution within the laser-induced plasma. The electron number density behaviour with distance from the target at different power densities and its behaviour with time are shown. The electron number densities are found to be in the order of 1018 cm?3 and decay at a rate of 3×1015 electrons/cm3 ns.  相似文献   

15.
We present a white-light spectral interferometric technique employing a low-resolution spectrometer for a direct measurement of the dispersion of the ordinary and extraordinary group refractive indices of a quartz crystal over the wavelength range approximately from 480 to 860 nm. The technique utilizes a dispersive Michelson interferometer with the quartz crystal of known thickness to record a series of spectral interferograms and to measure the equalization wavelength as a function of the displacement of the interferometer mirror from the reference position, which corresponds to a balanced non-dispersive Michelson interferometer. We confirm that the measured group dispersion agrees well with that described by the dispersion equation proposed by Ghosh. We also show that the measured mirror displacement depends, in accordance with the theory, linearly on the theoretical group refractive index and that the slope of the corresponding straight line gives precisely the thickness of the quartz crystal.  相似文献   

16.
张晓青  施涌潮 《光学技术》2001,27(4):338-339
当用双波长全息干涉术通过单次曝光法或双曝光法对物体进行测量时 ,其效果相当于用一个等效波长λeq=λ1 λ2 /|λ1 -λ2 |对物体进行测量 ,扩大了测量波长的可选范围。采用莫尔理论从一个全新的角度对双波长全息干涉术的基本原理进行了分析和探讨 ,不仅揭示出了二者之间存在着的必然内在联系 ,而且还进一步证明了双波长全息干涉术的准确性和可行性 ,从而扩展了双波长全息干涉术的应用领域  相似文献   

17.
A synchronously pumped stimulated Raman oscillator (SPSRO) has been used to measure the group refractive indices of several liquids. The characteristics of the SPSRO are described.  相似文献   

18.
姜蕾  陈艺  代江云  刘念  吕嘉坤  张立华  李芳  贺红磊  高聪  沈昌乐 《强激光与粒子束》2022,34(12):121006-1-121006-4
基于光束扫描法的光纤预制棒折射率测试仪主要适用于直径和长度在一定范围内的圆柱形样品折射率分布的测试。提出一种套管辅助法可实现更短长度、更细直径和变直径样品的折射率测试。该方法将待测样品居中放置于一个尺寸符合测试要求的圆柱形套管内,并在套管内注入折射率匹配油,使其没过待测样品后按常规步骤进行测试。对比实验结果表明,套管辅助法与直接测量法的偏差与仪器的测量误差相当。采用套管法,获得了预制棒拉丝终止后变径区不同位置折射率的径向分布,可为拉丝过程的研究提供参考。  相似文献   

19.
A differential detection technique combined with a surface plasmon resonance technique is proposed for refractive index variation measurement. The experimental results demonstrate that our system can attain a resolution of 1.2 × 10?5 RIU (refractive index unit). In addition, a method for two-dimensional detection of the refractive index variation is demonstrated. The system is free from the influence of optical source fluctuation, and can improve the measurement sensitivity.  相似文献   

20.
花世群  骆英 《物理学报》2013,62(5):57801-057801
涂层的折射率是发光光弹性涂层方法采用斜射法应变分离时不可缺少的参数之一. 通过对发光光弹性涂层受斜入射光波激发时, 发射光波沿入射光波原路径返回振幅变化的理论分析, 提出一种基于发光涂层光学菲涅耳响应的折射率在线测量方法. 实验测量了罗丹明B为发光染料的发光光弹性涂层在入射角为60°、波长为465 nm光波激发下的涂层折射率. 测量结果表明: 新的折射率测量方法是可行的, 对于其他用途的发光涂层折射率测量同样适用. 关键词: 折射率 光学测量 光学涂层 光致发光  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号