 共查询到20条相似文献,搜索用时 15 毫秒
1.
An electroosmotic pump (EOP) capable of generating pressure above 3 MPa and μl/min flow rate with reverse phase mobile phases of HPLC was constructed and evaluated. The pump consisted of three parallel connected fused silica capillary columns (25 cm×320 μm I.D.) packed with 2 μm silica materials, hollow electrodes, a high voltage DC power supply, and a liquid pressure transducer. The EOP was applied in a capillary liquid chromatographic system for mobile phase delivery instead of a mechanical pump. Standard samples containing thiourea, naphthalene, anthracene, phenanthrene and acetonitrile were separated on a 15 cm×320 μm I.D. 5 μm Chromasil C18 packed capillary column with acetonitrile/water as mobile phase.  相似文献   

2.
毛细管等电聚焦和电渗泵驱动聚焦区带分离蛋白质   总被引:4,自引:0,他引:4  
建立了一种利用电渗泵驱动毛细管内的聚焦区带,实现毛细管电泳等电聚焦分离蛋白质的方法。通过控制电压来调节泵的输出流量,从而调节聚焦区带的迁移速度。适用于毛细管电泳等电聚焦两步法分离蛋白质等两性物质。考察了对牛血清白蛋白和溶菌酶两种粗提蛋白质混合物的分离,迁移时间的RSD分别为1.6%和1.3%,峰面积的RSD均为1.6%,证明方法可行。  相似文献   

3.
Analyses in chromatographic systems able to save mobile and stationary phases without reducing efficiency and resolution are of current interest. These advantages regarding savings have challenged us to develop a system dedicated to miniaturized liquid chromatography. This paper reports on the development of a high‐pressure syringe‐type pump, an oven able to perform isothermal and temperature programming and a software program to control these chromatographic devices. The experimental results show that the miniaturized system can generate reproducible and accurate temperature and flow rate. The system was applied to the separation of statins and tetracylines and showed excellent performance.  相似文献   

4.
A microfabricated electroosmotic pump with an integrated serpentine isolation channel was developed on a glass chip and applied to a capillary-based sequential injection analysis (SIA) system for an enzyme inhibition assay. The pump chip contains an anode reservoir, an ion-exchange membrane electric field decoupler (EFD) that also serves as a cathode reservoir, parallel pump channels and an isolation channel. A two-step etching process was adopted to etch the pump channels to a depth of 20 μm and the isolation channel to a depth of 90 μm. The pump flow rate was very stable: the relative standard deviation (RSD) of the pump rate was 1.9% for propulsion and 2.3% for aspiration. The pump chip was successfully applied to a capillary-based sequential injection analysis system with a confocal fluorescence detector. For repetitive analysis of a 13 μM fluorescein solution, an RSD of 0.6% was attained, which demonstrated the flow stability of the EOF pump. The system was then applied to an enzyme inhibition assay, the diethylenetriaminepentaacetic acid (DTPA) inhibition of the β-galactosidase-catalyzed hydrolysis of fluorescein di(β-d-galactopyranoside). Reproducible results (RSD<3.0%) were obtained.  相似文献   

5.
We integrate a high-pressure electroosmotic pump (EOP), a nanoflow gradient generator, and a capillary column into a miniaturized liquid chromatographic system that can be directly coupled with a mass spectrometer for proteomic analysis. We have recently developed a low-cost high-pressure EOP capable of generating pressure of tens of thousands psi, ideal for uses in miniaturized HPLC. The pump worked smoothly when it was used for isocratic elutions. When it was used for gradient elutions, generating reproducible gradient profiles was challenging; because the pump rate fluctuated when the pump was used to pump high-content organic solvents. This presents an issue for separating proteins/peptides since high-content organic solvents are often utilized. In this work, we solve this problem by incorporating our high-pressure EOP with a nano-flow gradient generator so that the EOP needs only to pump an aqueous solution. With this combination, we develop a capillary-based nano-HPLC system capable of performing nano-flow gradient elution; the pump rate is stable, and the gradient profiles are reproducible and can be conveniently tuned. To demonstrate its utility, we couple it with either a UV absorbance detector or a mass spectrometer for peptide separations.  相似文献   

6.
In the present study, theoretical model for the transient response of a capillary flow under the combined effects of electroosmotic and capillary forces at low Reynolds number is presented. The governing equation is derived based on the balance among the electrokinetic, surface, viscous and gravity forces. A non-dimensional transient governing equation for the penetration depth as a function of time is obtained by normalizing the viscous, gravity and electroosmotic forces with surface tension force. A new non-dimensional group for the electroosmotic force, Eo, is obtained through the non-dimensional analysis. This new non-dimensional group is a representation of combined electroosmosis and surface tension, i.e., capillarity. The numerical solution of governing equation is obtained to study the effect of different operating parameters on the flow front transport. In a combined flow, it is observed that the flow with positive and low negative magnitude Eo numbers, the attainment of equilibrium penetration depth is similar to a capillary flow. In case of high negative magnitude Eo numbers, complete filling of the channel is observed. The electrolyte with lower permittivity delays the progress of the flow front whereas a large EDL transports the electrolyte quickly. Higher viscous and gravity forces also delay the transport process in the combined flow. This model suggests that in combined flow the electrokinetic parameters also play an important role on the capillary flow and experiments are required to confirm this electrokinetic effect on capillary transport.  相似文献   

7.
Summary An investigation was carried out to study the electroosmotic flow (EOF) in micellar electrokinetic capillary chromatography (MECC). Fused silica capillaries were treated with various reagents to investigate the parameters influencing the magnitude and reproducibility of the EOF. The results for untreated and treated columns were collected and compared under the same experimental conditions. Furthermore, experiments with and without sodium dodecylsulfate (SDS) addition to the buffer were carried out to elucidate the influence of this surfactant on the EOF. The mechanisms behind the effects of these modifications on the EOF and the stability of the coatings on the column wall are discussed.  相似文献   

8.
9.
Nonmechanical pumping of liquids is of key importance for applications from the biomedical microfluidic chip to drug delivery systems. In this paper, a new electrokinetic pump (EOP) system with polycarbonate nanochannel membrane sandwiched between two membrane holders was constructed. The pump was tested with water and phosphate buffer at 1-6 V applied voltage, the maximum pressure and flow rate are 0.32 MPa (3.2 atm) and 4.2 mL/min for phosphate buffer, respectively. This proof-of-concept pump shows its potential use for drugs or chemical agents delivery by the usage of different membrane materials.  相似文献   

10.
A novel stationary phase triacontyl-functionalized monolithic silica capillary column was successfully prepared for reversed-phase capillary liquid chromatography. The performance of the monolithic silica capillary column coated with triacontyl chain for the separation of alkylbenzenes, xylene isomers, polycyclic aromatic hydrocarbons, and mixture of α- and β-carotenes was studied, which was compared to that using the monolithic silica capillary column coated with octadecyl chain. The comparison results showed that triacontyl-functionalized monolithic silica capillary column would be a promising media to be used for the separation of isomeric solutes with long chain in reversed-phase capillary liquid chromatography.  相似文献   

11.
Jianhui X  Guowang X  Pudun Z  Yufang Z  Yukui Z 《Talanta》2002,57(6):1093-1100
The rule of current change was studied during capillary electrophoresis (CE) separation process while the conductivity of the sample solution was different from that of the buffer. Using a quadratic spline wavelet of compact support, the wavelet transforms (WTs) of capillary electrophoretic currents were performed. The time corresponding to the maximum of WT coefficients was chosen as the time of current inflection to calculate electroosmotic mobility. The proposed method was suitable for different CE modes, including capillary zone electrophoresis, nonaqueous CE and micellar electrokinetic chromatography. Compared with the neutral marker method, the relative errors of the developed method for the determination of electroosmotic mobility were all below 2.5%.  相似文献   

12.
The most common method to determine the EOF in CE is to measure the migration time for a neutral marker. In this study, 12 compounds (three novel and some previously used) were investigated as EOF markers in aqueous and nonaqueous BGEs. In the aqueous buffer systems (ammonium acetate, sodium phosphate, and sodium borate) the evaluation included a wide pH range (2–12). Two BGEs contained chiral selectors (sulphated‐β‐CD, (?)‐diketogulonic acid) and one that contained a micellar agent (SDS) were included in the study. The majority of the evaluated compounds were found to migrate with the EOF in the water‐based BGEs and are thus useful as EOF markers. However, in the SDS‐based BGE only four of the compounds (acetone, acrylamide, DMSO, and ethanol) were found to be applicable. In the nonaqueous BGEs 11 markers (acetone, acetophenone, acrylamide, anthracene, benzene, 4‐(4‐methoxybenzylamino)‐7‐nitro‐2,1,3‐benzoxadiazole, benzyl alcohol, 2,5‐diphenyloxazole, ethanol, flavone, and mesityl oxide) seemed to be functional as EOF markers. Even though several of the evaluated compounds can be used as EOF markers in the investigated BGEs, the authors would recommend the use of acrylamide as a general marker for UV detection. Furthermore, the four fluorescent markers (of which three were novel) gave RSD values equal to the other markers and can be used for the determination of the EOF in CE or microchip CE with fluorescence detection.  相似文献   

13.
UV-absorbing neutral substances are commonly used as markers of mean electroosmotic flow in capillary electrophoresis for their zero electrophoretic mobility in an electric field. However, some of these markers can interact with background electrolyte components and migrate at a different velocity than the electroosmotic flow. Thus, we tested 11 markers primarily varying in their degree of methylation and type of central atom in combination with five background electrolyte cations differing in their ionic radii and surface charge density, measuring the relative electrophoretic mobility using thiourea as a reference marker. Our results from this set of experiments showed some general trends in the mobilization of the markers based on the effects of marker structure and type of background electrolyte cation on the relative electrophoretic mobility. As an example, the effects of an inadequate choice of marker on analyte identification were illustrated in the electrophoretic separation of glucosinolates. Therefore, our findings may help electrophoretists appropriately select electroosmotic flow markers for various electrophoretic systems.  相似文献   

14.
In this work, a novel molecularly imprinted polymer (MIP) monolithic column with integrated in‐column electroosmotic pump (EOP) was designed and successfully prepared to facilitate the capillary chromatography with MIP column. A silica‐based EOP was synthesized at the detection end of the MIP monolithic capillary column by so‐gel to provide the hydrodynamic driven force for the capillary chromatography. Because of large surface area and low fluidic resistance of the silica monolith,a strong and steady EOF was generated by silica‐based EOP, indicating that the EOP was quite compatible with MIP capillary column. With the sufficient EOF provided by EOP, the electro‐driven based capillary chromatographic separation of nitrophenol isomers was achieved in 4‐vinylpyridine‐based MIP monolithic capillary, which was originally proved infeasible because of the EOF shortage. No significant influence upon the specific recognition of the MIP was found due to the setting of EOP after the detection window of the column. The influence of experimental parameters on the EOF such as voltage and pH value of running buffer was investigated. The column was also evaluated by capillary liquid chromatographic mode to compare with EOP‐driven capillary chromatography. Higher column efficiency was obtained by EOP‐driven separation with improved peak shape. The results suggested that EOP‐supported technique would be a good way to solve the problem of weak EOF generation in electro‐driven capillary chromatography.  相似文献   

15.
In the present study, field-amplified sample stacking injection using the electroosmotic flow pump (FAEP) was developed for the capillary electrophoretic separation of the four nerve agent degradation products methylphosphonic acid (MPA), ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA) and cyclohexyl methylphosphonic acid (CMPA). Coupled to contactless conductivity detection, direct quantification of these non-UV active compounds could be achieved. Sensitivity enhancement of up to 500 to 750-fold could be obtained. The newly established approach was applied to the determination of the analytes in river water and aqueous extracts of soil. Detection limits of 0.5, 0.7, 1.4 and 2.7 ng/mL were obtained for MPA, EMPA, IMPA and CMPA, respectively, in river water and 0.09, 0.14, 0.44 and 0.22 μg/g, respectively, in soil.  相似文献   

16.
A novel designed electro-osmotic pump (EOP) with simple structure was assembled using three 20 cm x 530 microm i.d. fused-silica capillaries packed with 20 +/- 5 nm silica grains for capillary liquid chromatography. It was found that the pump could generate pressures over 20 MPa and several microL/min flow rate for most of the liquids being delivered with the applied voltage less than 10 kV. By increasing the pressure, decreasing the applied voltage and the electrical current, the thermodynamic efficiency was about 1-4%. A practical application of the EOP in a 20cm x 150 microm i.d. 3 microm C18 fused-silica analytical capillary column demonstrated the applicability of the pump.  相似文献   

17.
Kuo CY  Chiou SS  Wu SM 《Electrophoresis》2006,27(14):2905-2909
This paper describes approaches for large-volume sample stacking (LVSS) with an EOF pumpin CE for the determination of methotrexate (MTX) and its metabolites in human plasma. After pretreatment of plasma through a SPE cartridge, a large sample volume was loaded by hydrodynamic injection (3 psi, 70 s) into the capillary filled with phosphate buffer (70 mM, pH 6.0) containing 0.01% polyethylene oxide. Following removal of a large plug of sample matrix from the capillary using polarity switching (-25 kV), the separation of anionic analytes was subsequently performed without changing polarity again, achieving an improvement of sensitivity of around a 100-fold. The method was applied to therapeutic drug monitoring of MTX in one acute lymphoblastic leukemia patient. This study is one of very few applications showing the feasibility of LVSS in analysis of biological samples by CE.  相似文献   

18.
A simple method to perform selective on-line preconcentration of protein samples in capillary electrophoresis (CE) is described. The selectivity, based on protein electrophoretic mobility, was achieved by controlling electroosmotic flow (EOF). A short section of dialysis hollow fiber, serving as a porous joint, was connected between two lengths of fused silica capillary. High voltage was applied separately to each capillary, and the EOF in the system was controlled independently of the local electric field intensity by controlling the total voltage drop. An equation relating the EOF with the total voltage drop was derived and evaluated experimentally. On-line preconcentration of both positively charged and negatively charged model proteins was demonstrated without using discontinuous background electrolytes, and protein analytes were concentrated by approximately 60-200-fold under various conditions. For positively charged proteins, positive voltages of the same magnitude were applied at the free ends of the connected capillaries while the porous joint was grounded. This provided a zero EOF in the system and a non-zero local electric field in each capillary to drive the positively charged analytes to the porous joint. CE separation was then initiated by switching the polarity of the high voltage over the second capillary. For negatively charged proteins, the procedure was the same except negative voltages were applied at the free ends of the capillaries. Mobility-based selective on-line preconcentration was also demonstrated with two negatively charged proteins, i.e. beta-lactoglobulin B and myoglobin. In this case, negative voltages of different values were applied at the free ends of the capillaries with different values, which provided a non-zero EOF in the system. The direction of EOF was the same as that of the electrophoretic migration velocities of the protein analytes in the first capillary and opposite in the second capillary. By controlling the EOF, beta-lactoglobulin B, which has a higher mobility, could be concentrated over 150-fold with a 15 min injection while myoglobin, which has a lower mobility, was eliminated from the system.  相似文献   

19.
T. -L. Huang 《Chromatographia》1993,35(7-8):395-398
Summary A porous gel model of silica-solution interface was proposed to explain the pH hysteresis effect on the electroosmotic mobility with capillary zone electrophoresis in silica capillaries. It is speculated that, under acidic preconditionings of the capillaries, a porous gel layer is formed at the silica-solution interface, and the magnitudes of potential and electroosmotic mobility are then reduced due to the penetration of electrolyte counterions to the gel layer. On the other hand, under basic preconditionings, a fresh silica surfaces is created by dissolution of silica in alkaline conditions, and this would result in higher values of potential and electroosmotic mobility. The Guoy-Chapman-Stern-Grahame model was employed to simulate the pH-dependence of electroosmotic mobility for the silica capillaries with a gelling surface and with a fresh surface. The predicted data were compared with the experimental results and shown to support the explanation.  相似文献   

20.
A polydimethylsiloxane (PDMS)-modified monolithic silica column was prepared for performing reversed-phase capillary liquid chromatography. The prepared PDMS column has a permeability of 6.4×10(-14) m(2) with a plate height <9.2 μm. Alkylbenzenes and polycyclic aromatic hydrocarbons (PAHs) were well separated with the PDMS stationary phase, which exhibited similar selectivity and separation mechanism to that of octadecyl stationary phase. The hydrophobic interactions between the analytes and the PDMS stationary phase mainly play the roles for the separation of alkylbenzenes and PAHs. The characteristics of the PDMS column for the separation of alkylbenzenes and PAHs demonstrated that it would be a promising alternative to the octadecyl column.  相似文献   