首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new PVC membrane electrode for manganese(II) ion based on a recently synthesized Schiff base of 5-[(4-nitrophenylazo)-N-hexylamine]salicylaldimine is reported. The electrode exhibits a Nernstian response for Mn2+ ions over a wide concentration range (4.0 × 10−7 to 1.8 × 10−2 mol L−1) with a slope of 30.1 (±1.0). The limit of detection is 1.0 × 10−7 mol L−1. The electrode has a fast response time (∼10 s), a satisfactory reproducibility and relatively long life time. The proposed sensor revealed good selectivities over a wide variety of other cations include hard and soft metals. This electrode could be used in a pH range of 4.5-7.5. It was used as an indicator electrode in potentiometric titration of manganese(II) ions with EDTA solution.  相似文献   

2.
Preeti Nigam  Subir Kundu 《Talanta》2009,77(4):1426-1431
Cefotaxime a third generation cephalosporin drug estimation in nanomolar concentration range is demonstrated for the first time in aqueous and human blood samples using novel Schiff base octahedral Zn(II) complex. The cefotaxime electrochemistry is studied over graphite paste and Zn(II) complex modified graphite paste capillary electrodes in H2SO4 (pH 2.3) using cyclic voltammetry and differential pulse voltammetry. Cefotaxime enrichment is observed over Zn(II) complex modified graphite paste electrode probably due to interaction of functional groups of cefotaxime with Zn(II) complex. Possible interactions between metal complex and cefotaxime drug is examined by UV-vis and electrochemical quartz crystal microbalance (EQCM) techniques and further supported by voltammetric analysis. Differential pulse voltammetry (DPV) with modified electrode is applied for the determination of cefotaxime in acidified aqueous and blood samples. Cefotaxime estimation is successfully demonstrated in the range of 1-500 nM for aqueous samples and 0.1-100 μM in human blood samples. Reproducibility, accuracy and repeatability of the method are checked by triplicate reading for large number of samples. The variation in the measurements is obtained less than 10% without any interference of electrolyte or blood constituents.  相似文献   

3.
A new polyvinyl chloride (PVC) membrane electrode that is highly selective to Hg(II) ions was prepared by using bis[5-((4-nitrophenyl)azo salicylaldehyde)] (BNAS) as a suitable neutral carrier. The sensor exhibits a Nernstian response for mercury ions over a wide concentration range (5.0×10−2-7.0×10−7 M) with a slope of 30±1 mV per decade. It has a response time of <10 s and can be used for at least 3 months without any measurable divergence in potential. The electrode can be used in the pH range from 1.0 to 3.5. The proposed sensor shows fairly good discriminating ability towards Hg2+ ion in comparison with some hard and soft metals. The electrode was used in the direct determination of Hg2+ in aqueous solution and as an indicator electrode in potentiometric titration of mercury ions.  相似文献   

4.
A new modified carbon paste electrode based on a recently synthesized mercury (II) complex of a pyridine containing proton transfer compound as a suitable carrier for Br ion is described. The electrode has a linear dynamic range between 3.00×10−2 and 1.0×10−5 M with a near-Nernastian slope of 61.0±0.9 mV per decade and a detection limit of 4.0×10−6 M (0.32 ppm). The potentiometric response is independent of the pH of the solution in the pH range 4.0–8.3. The electrode possesses the advantages of low resistance, fast response and good over a variety of other anions. It was applied as an indicator electrode in potentiometric titration of bromide ions and for the recovery of Br from tap water.  相似文献   

5.
The study of the electrode reactions of palladium(II) at non-modified carbon paste electrodes (CPEs) in chloride solution has revealed the existence of a chloropalladate(II) complex at the electrode surface. The complex is formed during the application of anodic potentials after preceding palladium deposition. In the present paper the electrode reactions of PdII at CPEs modified with some N′,N′-disubstituted derivatives of N-benzoylthiourea [as selective ligands for palladium(II)] are studied in chloride solution by cyclic voltammetry. Two reduction peaks are observed in the cathodic scans recorded after deposition of palladium and anodization of the electrode. From the results it is concluded that [in addition to the chloropalladate(II) complex, observed at the non-modified electrode] a second palladium complex is formed at positive potentials. The formation of the palladium(II) complex of the N-benzoylthiourea derivatives by ligand exchange at the electrode surface is assumed. The ligand exchange itself occurs without charge transfer across the electrode|solution interface; therefore, it cannot be detected electrochemically. After palladium deposition and anodic treatment a pronounced "inverse" peak (i.e., an anodic peak in the cathodic scan) with peak currents up to 100 μA is observed at about +0.8 V. Its peak current increases with the amount of deposited palladium and the number of cycles. The reactions at the electrode surface are discussed. The results of the study reveal the existence of two different surface complexes of palladium(II) at ligand-modified CPEs, but the surface reactions could not be elucidated in detail. Electronic Publication  相似文献   

6.
Mashhadizadeh MH  Shoaei IS  Monadi N 《Talanta》2004,64(4):1048-1052
A new PVC membrane potentiometric sensor that is highly selective to Fe(III) ions was prepared by using 2-[(2-hydroxy-1-propenyl-buta-1,3-dienylimino)-methyl]-4-p-tolylazo-phenol [HPDTP] as a suitable carrier. The electrode exhibits a linear response for iron(III) ions over a wide concentration range (3.5 × 10−6 to 4.0 × 10−2) with a super Nernstian slope of 28.5 (±0.5) per decade. The electrode can be used in the pH range from 4.5 to 6.5. The proposed sensor shows fairly a good discriminating ability towards Fe3+ ion in comparison to some hard and soft metals such as Fe2+, Cd2+, Cu2+, Al3+ and Ca2+. It has a response time of <15 s and can be used for at least 2 months without any measurable divergence in response characteristics. The electrode was used in the direct determination of Fe3+ in aqueous samples and as an indicator electrode in potentiometric titration of Fe(III) ions.  相似文献   

7.
The electrooxidation of the antitumour drug 2-methyl-9-hydroxyellipticinium (Celiptium) was investigated by cyclic, differential-pulse and adsorptive voltammetry at carbon paste (CPE) and lipid-modified carbon paste electrodes (LM-CPE). The influence of the paste composition, i.e., the ratio of graphite to binder, was studied in order to elucidate the nature of the accumulation process at the surface of the CPE. The electrode surface coverage at saturation was calculated. A.c. measurements at the CPE and at the LM-CPE during the accumulation of Celiptium demonstrated an increased differential double layer capacity of the LM-CPE. The influence of several parameters that affect the adsorptive step at the CPE was investigated, such as pH, ionic strength and interfering ions. Improved signals were obtained at the CPE and the detection limit in 0.1 M sodium perchlorate (tacc.=3 min) was found to be 2 × 10?10 M. Measurements of the drug in dilute standard serum samples were done using the medium-exchange technique.  相似文献   

8.
Manganese(II) complex of (E)-2-(hydroxyl-5-methoxybenzylideneamino) phenol was synthesized and used as a suitable Mn(II) – selective membrane in PVC matrix. The plasticized membrane sensor exhibits a nersian response for Mn(II) ions over a wide concentration range of 6 × 10?6–2 × 10?2 M with slope of 29 ± 1 mV per decade. It has a response time of <11 s and can be used for 2 months without any measurable divergence in potential. The response of the proposed sensor is independent of pH between 4 and 9.5. The proposed sensor shows a fairly good discriminating ability towards Mn(II) in comparison with some hard and soft metals. The electrode was used in the determination of Mn(II) in aqueous solutions and as an indicator electrode in potentiometer titration of manganese ions against EDTA.  相似文献   

9.
N,N′,N″,N′′′-1,5,8,12-tetraazadodecane-bis(salicylaldiminato)(H2L) has been used as ionophore for preparing Mn2+ selective sensor. Membranes of different composition with regard to ratio of H2L:PVC:NPOE:NaTPB have been prepared and investigated. The best performance was obtained with the membrane of composition 10:150:150:10 (H2L:PVC:NPOE:NaTPB) (w/w; mg). This membrane generated linear potential response in the concentration range of 5.0 × 10−6 to 1.0 × 10−1 M with a Nernstian slope of 30.0 mV/decade of activity and fast response time (10 s). Hydrogen ion does not effect to the performance of sensor in the pH range 3.0-6.5. The sensor was found to be sufficient selective for Mn2+ over a number of alkali, alkaline and heavy metal ions and could therefore be used for the determination of manganese in various samples by direct potentiometry.  相似文献   

10.
Li Liu  Jun-feng Song  Peng-fei Yu  Bin Cui 《Talanta》2007,71(5):1842-1848
A novel voltammetric method for the determination of β-d-glucose (GO) is proposed based on the reduction of Cu(II) ion in Cu(II)(NH3)42+–GO complex at lanthanum(III) hydroxide nanowires (LNWs) modified carbon paste electrode (LNWs/CPE). In 0.1 mol L−1 NH3·H2O–NH4Cl (pH 9.8) buffer containing 5.0 × 10−5 mol L−1 Cu(II) ion, the sensitive reduction peak of Cu(II)(NH3)42+–GO complex was observed at −0.17 V (versus, SCE), which was mainly ascribed to both the increase of efficient electrode surface and the selective coordination of La(III) in LNW to GO. The increment of peak current obtained by deducting the reduction peak current of the Cu(II) ion from that of the Cu(II)(NH3)42+–GO complex was rectilinear with GO concentration in the range of 8.0 × 10−7 to 2.0 × 10−5 mol L−1, with a detection limit of 3.5 × 10−7 mol L−1. A 500-fold of sucrose and amylam, 100-fold of ascorbic acid, 120-fold of uric acid as well as gluconic acid did not interfere with 1.0 × 10−5 mol L−1 GO determination.  相似文献   

11.
A Nickel Schiff base complex, insoluble in water, was synthesized and used as modifier. A Nickel Schiff base modified carbon paste electrode MCPE was build. The electrodes were characterized by scanning electron microscopy (SEM), energy dispersive X-Ray spectroscopy (EDXS), cyclic voltammetry and chronoamperometry. The modifier is elctroactive, a well defined redox couple of NiIII/NiII in alkaline medium was made in evidence. It presents a quasi-reversible system with electron transfer coefficient (0.38) and electron transfer rate of 4.5 s−1. The electrogenerated NiIII species on the surface of the electrode act as an excellent catalyst toward thiosulfate oxidation reaction with a chemical rate constant Kh equal to 23,6 M−1s−1. The different techniques involved in this study qualify our modified electrode as sensitive, reliable and very stable for thiosulfate analysis.  相似文献   

12.
This work offers construction and comparative evaluation the performance characteristics of conventional polymer (I), carbon paste (II) and carbon nanotubes chemically modified carbon paste ion selective electrodes (III) for meclofenoxate hydrochloride are described. These electrodes depend mainly on the incorporation of the ion pair of meclofenoxate hydrochloride with phosphomolybdic acid (PMA) or phosphotungestic acid (PTA). They showed near Nernestian responses over usable concentration range 1.0 × 10−5 to 1.0 × 10−2 M with slopes in the range 55.15–59.74 mV (concentration decade)−1. These developed electrodes were fully characterized in terms of their composition, response time, working concentration range, life span, usable pH and temperature range. The electrodes showed a very good selectivity for Meclo with respect to a large number of inorganic cations, sugars and in the presence of the degradation product of the drug (p-chloro phenoxy acetic acid). The standard additions method was applied to the determination of MecloCl in pure solution, pharmaceutical preparations and biological samples. Dissolution testing was also applied using the proposed sensors.  相似文献   

13.
A new ion-selective electrode (ISE) for the detection of trace chromium(III) was designed by using 2-acetylpyridine and nanoporous silica gel (APNSG)-functionalized carbon paste electrode (CPE). The presence of APNSG acted as not only a paste binder, but also a reactive material. With 7.5 wt% APNSG proportions, the developed electrode exhibited wide dynamic range of 1.0 × 10−8 to 1.0 × 10−3 M toward Cr(III) with a detection limit of 8.0 × 10−9 M and a Nernstian slope of 19.8 ± 0.2 mV decade−1. The as-prepared electrode displayed rapid response (∼55 s), long-time stability, and high sensitivity. Moreover, the potentiometric responses could be carried out with wide pH range of 1.5-5.0. In addition, the content of Cr(III) in food samples, e.g. coffee and tea leaves, has been assayed by the developed electrode, atomic absorption spectrophotometer (AAS) and atomic emission spectrometer (ICP-AES), respectively, and consistent results were obtained. Importantly, the response mechanism of the proposed electrode was investigated by using AC impedance and UV-vis spectroscopy.  相似文献   

14.
The construction and performance characteristics of polymeric membrane electrodes based on two neutral ionophores, N,N′-[bis(pyridin-2-yl)formylidene]butane-1,4-diamine (S1) and N-(2-pyridinylmethylene)-1,2-benzenediamine (S2) for quantification of cadmium ions, are described. The influences of membrane compositions on the potentiometric response of the electrodes have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (w/w) of (S1) (2.15%):PVC (32.2%):o-NPOE (64.5%):KTpClPB (1.07%). The proposed electrode exhibits Nernstian response in the concentration range of 7.9 × 10−8 to 1.0 × 10−1 M Cd2+ with limit of detection 5.0 × 10−8 M, performs satisfactorily over wide pH range (2.0-8.0) with a fast response time (10 s). The sensor has been found to work satisfactorily in partially non-aqueous media up to 30% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 2 months. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of cadmium in real samples. The practical utility of the membrane electrode has also been observed in the presence of surfactants.  相似文献   

15.
《Electroanalysis》2006,18(16):1598-1604
Four Schiff base complexes of different metal ions, M=Cr(III), Mn(III), Fe(III), and Co(III), were studied to characterize their ability as sulfate ion carriers in carbon paste electrode (CPE). The modified CPE electrode with Schiff base complex of Cr(III), N,N′‐ethylenebis(5‐hydroxysalicylideneiminato) chromium(III) Chloride, showed good response characteristics to SO42? ion. The proposed electrode exhibits a Nernstian slope of 28.9±0.4 mV per decade for SO42? ion over a wide concentration range from 1.5×10?6?4.8×10?2 M, with a detection limit of 9.0×10?7 M. The CPE electrode manifested advantages of relatively fast response time, suitable reproducibility and life time and, most important, good potentiometric selectivity relative to a wide variety of other common inorganic anions. The potentiometric response of the electrode is independent of the pH of the test solution in the pH range 4.0–9.0. The proposed electrode was used as an indicator electrode in potentiometric titration of sulfate with Ba2+ ion, the determination of zinc in zinc sulfate tablet and also determination of sulfate content of a mineral water sample.  相似文献   

16.
A chemically modified carbon paste electrode with 3,4-tetra pyridinoporphirazinatocobalt(II) (Co(3,4 tppa) was applied to the determination of free cyanide ion. The electrode has a linear range between 1.5 × 10−5 M and 1.0 × 10−2 M with a Nernstian slope of 60 ± 1.5 mV/decade and its detection limit is 9 × 10−6 M. The response time of electrode is 5 min. The proposed electrode was applied successfully for the determination of cyanide in commercially available spring water. Some anions, such as SCN, I, Cl, Br and oxalate that are usually serious interfering species for most of cyanide selective electrodes, did not have any interfering effect for this proposed electrode.  相似文献   

17.
Zen JM  Hsu CT 《Talanta》1998,46(6):1363-1369
A square-wave voltammetric method together with Nafion®-coated carbon paste electrodes were used for the selective determination of uric acid in the presence of a high concentration of ascorbic acid. Since the oxidation potential of uric acid is about 200 mV more positive than that of ascorbic acid at the Nafion®-coated carbon paste electrode, the selectivity can be greatly improved simply by applying an electrolysis potential of +0.4 V vs. Ag/AgCl where only ascorbic acid is oxidised. The acceptable tolerance of ascorbic acid concentration for the determination of uric acid is as high as 1.5 mM. With 30 s of electrolysis time, a linear calibration curve is obtained over the 0–50 μM range in 0.05 M citrate buffer solution, pH 4.0, with slope (μA/μM) and correlation coefficient of 0.34 and 0.9984, respectively. The detection limit (3σ) is 0.25 μM. The practical analytical utility is illustrated by selective measurements of uric acid in human urine without any preliminary treatment.  相似文献   

18.
A new approach for decreasing the detection limit for a copper(II) ion-selective electrode (ISE) is presented. The ISE is designed using salicylidine-functionalized polysiloxane in carbon paste. This work describes the attempts to develop the electrode and measurements of its characteristics. The new type of renewable three-dimensional chemically modified electrode could be used in a pH range of 2.3–5.4, and its detection limit is 2.7 × 10−8 mol L−1 (1.2 μg L−1). This sensor exhibits a good Nernstian slope of 29.4 ± 0.5 mV/decade in a wide linear concentration range of 2.3 × 10−7 to 1.0 × 10−3 mol L−1 of Cu(II). It has a short response time (8 s) and noticeably high selectivity over other Cu(II) selective electrodes. Finally, it was satisfactorily used as an indicator electrode in complexometric titration with EDTA and determination of copper(II) in miscellaneous samples such as urine and various water samples.  相似文献   

19.
Four different 9,10-anthraquinone derivatives were studied to characterize their abilities as lead ion carrier in PVC membrane electrodes. The electrode based on 1,8-dihydroxy-2,7-bis(prop-2′-enyl)-9,10-anthraquinone exhibits a Nernstian response for Pb2+ ions over a wide concentration range (2.0×10−3–2.0×10−6 M). The response time of the sensor is 30 s and the membrane can be used for more than four months without observing any deviation. The electrode revealed comparatively good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of sulfate ions with a lead ion solution.  相似文献   

20.
The density functional and ab initio theory were used to investigate the second‐order nonlinear optical (NLO) properties of Schiff base ligands, open‐shell Fe(III), and closed‐shell Ni(II) complexes. The effect of the metal center in complexes is thus manifold: it templates the formation of acentric structures, imparts high thermal stability to the chelate ring, and display higher second‐order NLO response than their ligands. The second‐order NLO response of metal complexes are intensively sensitive to the exchange donor/acceptor because the differences of the extent of charge separation and the intraligand charge transfer processes. Thus, substituted metal complexes could realize “switches on” the second‐order NLO response by exchange donor/acceptor. © 2009 Wiley Periodicals, Inc. Int J Quantum Chem, 2010  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号