首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A high-performance liquid chromatographic (HPLC) method was developed to determine the (+)- and (-)-enantiomers of pirprofen, an anti-inflammatory drug. After addition of an internal standard, the plasma sample was brought onto a glass column pre-packed with silica and eluted with dichloromethane. The extracts were derivatized with 1,1'-carbonyldiimidazole and R (+)-1-methylbenzylamine to form the two diastereomeric amides. The diastereoisomers were separated on a chiral column by HPLC with ultraviolet detection at 272 nm using n-hexane-dichloromethane (64:36, v/v) as the mobile phase. The limit of quantitation was 0.992 mumol/l (0.25 microgram/ml) for each enantiomer.  相似文献   

2.
A high-performance liquid chromatographic method for the simultaneous determination of both enantiomers of naproxen and its metabolite 6-O-desmethylnaproxen has been developed. The separation is performed on a column containing alpha 1-acid glycoprotein as the chiral selector. The method has been used for the determination of the enantiomeric purity of the drug substance and the metabolite, and for the simultaneous determination of all four compounds in biological fluids.  相似文献   

3.
An enantioselective high-performance liquid chromatographic assay for the quantification of methadone in human and beagle plasma is described. The procedure involves extraction of methadone from alkalized plasma into hexane-isoamyl alcohol (99:1, v/v). Stereoselective separation was achieved with a silica column with covalently bound alpha 1-acid glycoprotein (Chiral-AGP) without any derivatization procedure. The detection wavelength was set at 215 nm. Using an internal standard provided reliable control of the extraction procedure as well as quantification of the enantiomers of methadone. The limit of quantification was found to be 2.5 ng/ml. The method was demonstrated to be sufficiently sensitive for stereoselective pharmacokinetic studies of methadone.  相似文献   

4.
氯苄哌醚联苯酰苯酸盐主要用于止咳,L-氯苄哌醚联苯酰苯酸盐具有更高活性.采用手性色谱柱,建立了氯苄哌醚联苯酰苯酸盐光学异构体的拆分方法,并将其用于氯苄哌醚联苯酰苯酸盐的检测.结果表明,采用Chiralcel OD-H柱,在流动相V(正己烷)∶V(异丙醇)∶V(二乙胺)=98∶2∶0.1的条件下,2个异构体能同时达到基线分离,检测波长为254nm,氯苄哌醚联苯酰苯酸盐检测极限为10ng.这表明所建立的分离分析方法可方便可靠地用于该化合物的光学纯度检测.  相似文献   

5.
The quantitative enantiospecific determination of the beta 1-selective adrenergic antagonist (R,S)-celiprolol in human plasma and urine is described. It involves a two-step liquid-liquid extraction of celiprolol from biological material and separation of the underivatized enantiomers by high-performance liquid chromatography on a chiral stationary phase (cellulose tris-3,5-dimethylphenyl carbamate, coated on silica gel) with fluorimetric detection. R-(+)-Propranolol was used as an internal standard. The detection limits of 1.5 ng/ml enantiomer in plasma and 2.5 ng/ml enantiomer in urine at signal-to-noise ratios higher than 3 permit the performance of pharmacokinetic studies after therapeutic doses.  相似文献   

6.
In the present study, a simple and rapid method for metamizole metabolite 4-methylamino antipyrine (MAA) determination in human plasma was developed, validated and successfully applied to a clinical trial. Chromatographic separation was achieved in HILIC mode on a YMC-Pack SIL column (100 × 2.0 mm; S-5 μm, 30 nm), with a mobile phase consisting of acetonitrile, water and formic acid. Protein precipitation of a small plasma volume using acetonitrile was selected for sample preparation. The multiple reaction monitoring transitions in the positive ionization mode were m/z 218.2 → 56.2 for MAA and m/z 221.2 → 56.2 for MAA-d3 (IS, internal standard). Concentration levels of MAA calibration standards were in the range of 0.100–20 μg/ml. Metamizole conversion into MAA in both water and organic media was investigated, and the level of the conversion in commercially available injection solutions was estimated.  相似文献   

7.
8.
Summary An HPLC method has been developed for the quantification of rantidine in plasma for pharmacokinetic studies. Metoclopramide was used as internal standard. The method uses a simple and rapid sample clean-up procedure involving single-step extraction with organic solvent to extract ranitidine from plasma. After evaporation and reconstitution the samples are chromatographed on a 250 mm×4 mm base-stable reversed-phase column with 0.05 M ammonium acetate-acetonitrile, 75∶25 (v/v) as mobile phase and UV detection at 313 nm. The calibration graph was linear for quantities of ranitidine between 10 and 2000 ng mL−1. Intra- and inter-dayCV did not exceed 11.64%. The quantitation limit was 10 ng mL−1 for human plasma. The applicability of this method for pharmacokinetic studies of ranitidine after oral administration are described. Approximately 90 samples can be processed in 24 h.  相似文献   

9.
A sensitive and specific method for the determination of quinidine in plasma is described. Quinidine is extracted with chloroform, the extract is evaporated and reconstituted with methanol and the methanol extract is analyzed by high-performance liquid chromatography using a silica gel column. The recovery of quinidine from plasma varied between 93.0 to 100%. Quinidine levels as low as 12 ng/ml can be detected by this method.  相似文献   

10.
11.
12.
13.
A sensitive and selective high-performance liquid chromatographic method for the determination of reboxetine enantiomers in human plasma was developed. Although two chiral centres are present in reboxetine, its stereospecific synthesis leads to two rather than four possible enantiomers. After extraction from plasma and reaction with (+)-1-(9-fluorenyl)ethyl chloroformate, reboxetine enantiomers were separated as diastereoisomeric derivatives by reversed-phase high-performance liquid chromatography (HPLC) and determined by fluorimetric detection. The HPLC analysis time was about 90 min. The linearity, precision, accuracy and limit of quantification of the method were evaluated. No interference from blank plasma sample was observed. The suitability of the method for in vivo samples was assessed by the analysis of plasma samples obtained from a healthy male volunteer who had received a single oral dose of 4 mg of reboxetine in tablet form.  相似文献   

14.
A high-performance liquid chromatographic (HPLC) procedure with photodiode-array detection (DAD) is described for the determination of (S)-(-)-cathinone (S-CA) and its metabolites (R,S)-(-)-norephedrine (R-NE) and (R,R)-(-)-norpseudoephedrine (R-NPE) in urine. Extraction and clean-up of 1-ml urine samples were performed on a cyano-bonded solid-phase column using (+/-)-amphetamine as internal standard. The concentrated extracts were separated on a 3-microns ODS-1 column with acetonitrile-water-phosphoric acid-hexylamine as the mobile phase. Peak detection was done at 192 nm. The detection limits for S-CA and R-NE/R-NPE in urine were 50 and 25 ng/ml, respectively. The differentiation of the enantiomers of cathinone and norephedrine was achieved by derivatization with (S)-(-)-1-phenylethyl isocyanate to the corresponding diastereomers followed by HPLC-DAD on a 5-microns normal-phase column. The R and S enantiomers of norpseudoephedrine were determined by gas chromatography-mass spectrometry after on-column derivatization with (S)-(-)-N-trifluoroacetylprolyl chloride. Following a single oral dose of 0.5 mg/kg of S-CA, the concentrations found in urine ranged from 0.2 to 3.8 micrograms/ml of S-CA, from 7.2 to 46.0 micrograms/ml of R-NE and from 0.5 to 2.5 micrograms/ml of R-NPE.  相似文献   

15.
16.
The development and validation of a high-performance liquid chromatography (HPLC) method for the simultaneous determination of itraconazole and its metabolite, hydroxyitraconazole, in human plasma is described. The method involved liquid-phase extraction of itraconazole and hydroxyitraconazole using a hexane-dichloromethane (70:30) mixture, after addition of loratidine as an internal standard (IS). Separation was achieved with a reversed-phase C18 column (250 mm x 4.6 mm) employing fluorescence detection (excitation: 264 nm, emission: 380 nm). The mobile phase consisted of [0.01% triethylamine solution adjusted to pH 2.8 with orthophosphoric acid-acetonitrile (46:54)]-isopropanol (90:10, v/v) at a flow rate of 1.0 ml/min. For both the drug and metabolite, the standard curve was linear from 5.0 to 500 ng/ml with goodness of fit (r2) greater than 0.98 observed with four precision and accuracy batches during validation. An observed recovery was more than 70% for drug, metabolite and internal standard. The applicability of this method to pharmacokinetic studies was established after successful application during 35 subjects bioavailibity study. The method was found to be precise, accurate and specific during the study.  相似文献   

17.
A rapid and simple high-performance liquid chromatographic assay for the determination of propyphenazone in plasma is described. Phenylbutazone was used as the internal standard. Plasma proteins were precipitated with acetonitrile before injection onto a 3-microns Supelcosil LC-18 column. The mobile phase, ethanol containing 0.2% (v/v) heptylamine-0.005 M potassium dihydrogenphosphate (30:70, v/v), was used at a flow-rate of 1.3 ml/min. The quantitation was performed by ultraviolet detection at a wavelength of 270 nm. The chromatographic time was 7 min. The within- and between-day coefficients of variation were less than 6% and the recoveries close to 100% for concentrations between 0.4 and 22 mumol/l. The limit of quantitation was 0.4 mumol/l (ca. 100 ng/ml).  相似文献   

18.
(15R)-15-Methylprostaglandin E2 (PGE2) is a pro-drug under evaluation for the treatment of acute upper gastrointestinal hemorrhage and gastrointestinal cytoprotection. It is converted in acid (e.g., gastric fluid) to its active 15S epimer. Both epimers are found in human plasma at low pg/ml levels following oral dosing. A high-performance liquid chromatographic (HPLC) method was developed for the simultaneous analysis of (15R)- and (15S)-15-methyl-PGE2 in human plasma. The method combined off-line solid-phase extraction and reversed-phase HPLC clean-up with panacyl bromide derivatization and subsequent analysis using a heteromodal column-switching technique. Assay linearity was demonstrated over a range of 10-200 pg/ml for both 15-methyl-PGE2 epimers (r greater than or equal to 0.995). There were no significant inter-day differences in assay results for either epimer at 50 and 25 pg/ml (p greater than 0.05), with pooled estimates of precision at these levels producing relative standard deviations of less than or equal to 8% and less than or equal to 12%, respectively. The method quantitation limit (signal-to-noise ratio 5:1) for both epimers was 10 pg/ml when processing 3 ml of plasma. The analysis procedure was shown to be useful for quantifying at or below 10% of the (15R)-15-methyl-PGE2 maximum plasma concentration following a 50-micrograms oral dose in three human volunteers. For the same three subjects, however, the plasma concentration of (15S)-15-methyl-PGE2 did not exceed the quantitation limit of 10 pg/ml.  相似文献   

19.
A high-performance liquid chromatographic method with fluorometric detection has been developed for the determination of succinylcholine in human plasma. Succinylcholine shows fluorescence at 282 nm with an excitation at 257 nm. The assay is sensitive, reproducible and linear for concentrations ranging from 100 ng/ml to 100 micrograms/ml of succinylcholine. In a pilot study the plasma concentration-time curve showed a triphasic elimination, with half-lives of 0.4, 1.2 and 8 min, respectively. In a clinical setting, drugs commonly administered during anaesthesia did not interfere with the assay. This method provides a simple and time-saving alternative to existing methods.  相似文献   

20.
A validated, sensitive and precise reversed-phase high-performance liquid chromatographic method for the simultaneous determination of 5-flucytosine (5-FC) and 5-fluorouracil (5-FU) in human plasma is described. Two compounds, 5-methylcytosine (5-MC) and 5-chlorouracil (5-CU), were used as internal standards for the determination of 5-FC and 5-FU, respectively. Plasma samples were deproteinized with trichloroacetic acid and chromatographed on an octylsilica column, maintained at 30 degrees C during elution, using a 0.04 M phosphate buffer, pH 7.0, as eleunt. Spectrophotometric diode array detection was used at 266 nm. 5-FC, 5-FU, 5-MC and 5-CU were found to have retention times of 4.8, 5.8, 7.7 and 11.0 min respectively. Recoveries of 91-120% with reproducibility and repeatability coefficients of variation of 0.8-6% were obtained. Mean correlation coefficients of 0.99989 and 0.9995 were found for the linear calibration curves (n = 2) of 5-FC (4.816-192.6 mg/l) and 5-FU (0.05368-5.368 mg/l), respectively. The limits of quantitation were 0.3 mg/l for 5-FC and 0.05 mg/l for 5-FU.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号