首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Capillary electrophoresis (CE) coupling with a tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL) detection technique was developed for the analysis of two beta-blockers, atenolol (AT) and metoprolol (ME). The parameters that influence the separation and detection, including the buffer pH and concentration, the separation voltage, the detection potential and Ru(bpy)(3)(2+) concentration, were optimized in detail. The calibration curve was linear over a concentration range of two or three orders of magnitude for the two beta-blockers. The detection limits for AT and ME were 0.075 and 0.005 microM (S/N = 3). The relative standard deviations (n = 8) of the ECL intensity and the migration time were 2.65 and 0.22% for AT, 2.82 and 0.34% for ME, respectively. The proposed method was applied to determine AT and ME in spiked urine samples; satisfactory results were obtained.  相似文献   

2.
Xu G  Pang HL  Xu B  Dong S  Wong KY 《The Analyst》2005,130(4):541-544
The dependence of the electrochemiluminescence of Ru(bpy)3(2+) (bpy = 2,2'-bipyridine) with tri-n-propylamine as co-reactant on the anionic surfactant SDS (sodium dodecyl sulfate) and the cationic surfactants CTAX (CTA = cetyltrimethylammonium cation, X = bromide, chloride and hydrogensulfate) was studied. Both SDS and CTAX, at low surfactant concentrations below the critical micelle concentrations, enhance the electrochemiluminescence at a platinum working electrode. A further enhancement of the light emission intensity by bromide ions was observed when CTAB (B = bromide) was used-an overall 30-fold increase in electrochemiluminescence efficiency was obtained at a CTAB concentration of 0.08 mM. Voltammetric data support adsorption of surfactant molecules on the electrode surface as the cause of the enhancement of electrochemiluminescence by ionic surfactants.  相似文献   

3.
A chemically initiated adaptation of the classic [Ru(bipy)(3)](2+)/oxalate electrochemiluminescence coreactant system has revealed the elusive radical intermediates of the light-producing pathway. Oxalyl (HC(2)O(4)˙) and hydroxyformyl (HCO(2)˙) radicals have been captured on a quartz surface and characterised using EPR spectroscopy.  相似文献   

4.
Liu J  Cao W  Yang X  Wang E 《Talanta》2003,59(3):453-459
Tris(2,2′-bipyridyl)ruthenium(II) electrochemiluminescence detection in a capillary electrophoresis separation system was used for the determination of diphenhydramine. In this study, platinum disk electrode (300 μm in diameter) was used as a working electrode and the influence of applied potential and buffer conditions were investigated. Under optimal conditions: 1.2 V applied potential, pH 8.50, 15 kV separation voltage and 10 mmol l−1 running buffer, the calibration curve of diphenhydramine was linear over the range of 4×10−8 to 1×10−5 mol l−1. This technique gave satisfactory precision, and relative standard deviations of migration times and chemiluminescence peak intensities were less than 1 and 6%, respectively. The technique was applied to animal studies for determination of diphenhydramine extracted from rabbit plasma and urine samples, and the extraction efficiency were between 92 and 98.5%.  相似文献   

5.
Liu J  Yang X  Wang E 《Electrophoresis》2003,24(18):3131-3138
Capillary electrophoresis (CE) with tris(2,2'-bipyridyl) ruthenium (II) (Ru(bpy)3(2+)) electrochemiluminescence (ECL) detection technique was developed for the analysis of four polyamines (putrescine (Put), cadaverine (Cad), spermidine (Spd), and spermine (Spm)) analysis. The four polyamines contain different amine groups, which have different ECL activity. There are several parameters which influence the resolution and ECL peak intensities, including the buffer pH and concentrations, separation voltage, sample injection, electrode materials, and Ru(bpy)3(2+) concentrations. Polyamines are separated by capillary zone electrophoresis in an uncoated fused-silica capillary (50 cmx25 micro m (ID) filled with acidic phosphate buffer (200 mmol/L phosphate, pH 2.0) - 1mol/L phosphoric acid (9:1 v/v) and a separation voltage of 5 kV (25 micro A), with end-column Ru(bpy)3(2+) ECL detection. A 5 mmol/L Ru(bpy)3(2+) solution plus 200 mmol/L phosphate buffer (pH 11.0) is added into the reagent reservoir. The calibration curve is linear over a concentration range of two or three orders of magnitude for the polyamines. The analysis time is less than 25 min. Detection limits for Put and Cad are 1.9x10(-7) mol/L and 7.6x10(-9) mol/L for Spd and Spm, respectively. Intraday and interday relative standard deviations of ECL peak intensities are less than 8%. The main advantages of this CE-ECL detection technique for polyamines analysis presented herein are the omission of chemical derivatization of the analytes and the high selectivity.  相似文献   

6.
A novel method for immobilization of tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)3Cl2) on electrode surfaces based on the vapor-surface sol-gel deposition strategy is first demonstrated in this paper. Ru(bpy)3Cl2 immobilized sol-gel (Ru(bpy)3Cl2/sol-gel) films were characterized by UV-vis spectroscopy and field-emitted scanning electron microscopy (FE-SEM). These results showed that Ru(bpy)3Cl2 was successfully incorporated into the silica sol-gel film. It was found that many irregular Ru(bpy)3Cl2/sol-gel clusters were formed on surfaces through one deposition and thick sol-gel films were observed after further deposition. Electrochemical properties and electrochemiluminescence (ECL) behaviors of Ru(bpy)3Cl2/sol-gel films could be easily adjusted by deposition numbers and time. At last, the Ru(bpy)3Cl2/sol-gel film modified electrode was used for solid-state ECL detection of tripropylamine. The linear range was from 5.8 × 10−8 to 2.4 × 10−4 M with the detection limit of 5 nM, which was three orders of magnitude lower than that from pure Nafion-modified electrodes. The ECL sensor also exhibited high stability, and still remained 92% response after being stored in air for 35 days. This method for immobilization of Ru(bpy)3Cl2 is simple, convenient and low-cost relative to others, so it shows promising applications in solid-state ECL detection.  相似文献   

7.
Bruce D  McCall J  Richter MM 《The Analyst》2002,127(1):125-128
The effects of electron withdrawing and electron donating groups on the electrochemiluminescent (ECL) properties of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+) where bpy = 2,2'-pyridine) are reported. The electrochemistry, photophysics and ECL of (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+ (DC = 4,4'-dicarboxy-2,2'-bipyridine; DM = 4,4'-dimethyl-2,2'-bipyridine) have been studied relative to Ru(bpy)3(2+) in 50:50 (v/v) acetonitrile(CH3CN):H2O (0.1 M KH2PO4), and aqueous solutions. Furthermore, the effects of Triton X-100 (polyethylene glycol tert-octylphenyl ether) on the electrochemical, spectroscopic and ECL properties of these compounds are reported. The anodic oxidation of Ru(bpy)3(2+), (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+ produces ECL in the presence of tri-n-propylamine (TPrA) in all solvent systems. ECL efficiencies (phi(ecl), photons produced per redox event) of 0.73 and 0.84 for (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+ were obtained in aqueous buffered solution, using Ru(bpy)3(2+) as a relative standard (phi(ecl) = 1.0). Addition of 0.4 mM Triton X-100 results in a greater than 2-fold increase in ECL efficiences (i.e., 3.8, 2.4 and 2.3 for Ru(bpy)3(2+), (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+, respectively) using aqueous Ru(bpy)3(2+) containing no surfactant as standard (phi(ecl) = 1.0). ECL efficiencies of 27.4, 16.5 and 26.1 were found in 50:50 (v/v) CH3CN:H2O (0.1 M KH2PO4) for Ru(bpy)3(2+), (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+, respectively, using aqueous Ru(bpy)3(2+) containing no surfactant as standard (phi(ecl) = 1.0). Detailed studies support adsorption of surfactant on the electrode surface, thus facilitating TPrA and ruthenium oxidation.  相似文献   

8.
9.
Yuan Y  Li H  Han S  Hu L  Parveen S  Xu G 《Analytica chimica acta》2011,701(2):169-173
Vitamin C derivatives (VCDs) have been widely used as the alternative and stable sources of vitamin C, and accordingly exhibit many new applications, such as anti-tumor and central nervous system drug delivery. In this study, their Ru(bpy)32+ electrochemiluminescence (ECL) properties have been investigated for the first time using well-known ascorbyl phosphate and ascorbyl palmitate as representative VCDs. Ascorbyl phosphate and ascorbyl palmitate are VCDs with different substituted positions. Both of them increase Ru(bpy)32+ ECL, indicating that other VCDs may also enhance Ru(bpy)32+ ECL signal. The calibration plot for ascorbyl phosphate is linear from 3 × 10−6 to 1.0 × 10−3 M with a detection limit of 1.4 × 10−6 M at a signal-to-noise ratio of 3. The relative standard deviation is 3.6% for six replicate measurements of 0.01 mM ascorbyl 2-phosphate solution. The proposed method is about one order of magnitude more sensitive than electrochemical and UV–vis methods for the determination of ascorbyl phosphate, and is used successfully for the determination of ascorbyl phosphate in whitening and moisturising body wash.  相似文献   

10.
The apparent diffusion coefficients of tris(2,2'-bipyridyl)ruthenium ([Ru(bpy(3))](2+)) are estimated in silica-nanochannels which are assembled inside columnar alumina pores in an anodic alumina membrane, and are modified with alkylsilanes such as trimethylchlorosilane (C1), butyldimethylchlorosilane (C4), and dodecyldimethylchlorosilane (C12). The estimation is performed by observing the lag-time, which is defined as the time required for [Ru(bpy)(3)](2+) to diffuse through alkylsilane-modified silica-nanochannels in the alumina membrane. When ethanol is used as a solvent, the apparent diffusion coefficients of [Ru(bpy)(3)](2+) are estimated as 2.1 x 10(-10) and 3.2 x 10(-10) cm(2) s(-1) in the C1- and C4-modified silica-nanochannels, respectively. These values are about 10(4) times smaller than that obtained in bulk ethanol. Based on the experimental results on the solvent dependency of the lag-time, the hydrogen-bonding interaction between ethanol molecules is considered to be stronger in the C1- and C4-modified silica-nanochannels than in bulk ethanol, and the hydrogen-bonding interaction plays a critical role for the slow diffusivity in those nanochannels. In contrast, the apparent diffusion coefficient in the C12-modified silica-nanochannel is at least two orders of magnitude larger than those in the C1- and C4-modified silica-nanochannels. This relatively fast diffusion is most likely explained by the presence of a long alkyl chain of C12, which reduces a hindrance effect that is originates in the hydrogen-bonding interaction.  相似文献   

11.
Lei Qian  Xiurong Yang 《Talanta》2007,73(1):189-193
In this paper, we demonstrate an electrochemiluminescence (ECL) enhancement of tris(2,2-bipyridyl)ruthenium(II) (Ru(bpy)32+) by the addition of silver(I) ions. The maximum enhancement factor of about 5 was obtained on a glassy carbon electrode in the absence of co-reactant. The enhancement of ECL intensity was possibly attributed to the unique catalytic activity of Ag+ for reactions between Ru(bpy)33+ with OH. The higher enhancement was observed in phosphate buffer solutions compared with that from borate buffer solutions. This resulted from the fact that formation of nanoparticles with large surface area in the phosphate buffer solution exhibited high catalytic activity. The amount of Ag+, solution pH and working electrode materials played important roles for the ECL enhancement. We also studied the effects of Ag+ on Ru(bpy)32+/tripropylamine and Ru(bpy)32+/C2O42− ECL systems.  相似文献   

12.
Yin J  Xu Y  Li J  Wang E 《Talanta》2008,75(1):38-42
A capillary electrophoresis method coupled with electrochemiluminescence detection for the analysis of quinolizidine alkaloids was established, especially, oxymatrine (OMT) which could not be measured by previous electrochemiluminescence methods was detected sensitively herein. Complete separation of sophoridine (SR), matrine (MT) and OMT was achieved within 13 min using a background electrolyte of 50mM phosphate buffer at pH 8.4 and a separation voltage of 15 kV. The calibration curves showed a linear range from 2.8 x 10(-8) to 4.4 x 10(-7) M for SR, 2.7 x 10(-8) to 4.4 x 10(-7) M for MT, and 2.5 x 10(-7) to 4.0 x 10(-6)M for OMT, respectively. The relative standard derivations for all analytes were below 3.1%. Good linear relationships were showed with correlation coefficients for all analytes exceeded 0.987. The detection limits were 1.0 nM for SR and MT, and 40 nM for OMT under the optimal conditions, respectively. The developed method was nearly harmless to the human and environment.  相似文献   

13.
Ding SN  Xu JJ  Chen HY 《Electrophoresis》2005,26(9):1737-1744
The major goal of this work was to develop a new solid-state electrochemiluminescence (ECL) detector suitable for capillary electrophoresis (CE). The detector was fabricated by coating a sol-gel derived zirconia (ZrO(2))-Nafion composite film on a graphite electrode, then the zirconia-Nafion modified electrode was immersed in tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3) (2+)) solution to immobilize this active chemiluminescence reagent. The voltammetric and ECL behaviors of the detector were investigated and optimized in tripropylamine solution. The ratio of 53% for zirconia in the zirconia-Nafion composite provided the highest luminescence intensity of immobilized Ru(bpy)(3) (2+). The ECL can maintain its stability very well in the phosphate solution in the period of 5-90 h when the solid-state ECL detector was immersed in the solution all the time. The optimum distance of capillary outlet to the solid-state ECL detector has been found to be ca. 50-80 microm for a 75 microm capillary. The effects of ionic strength and pH of ECL solution on peak height were investigated. The CE with solid-state ECL detector system was successfully used to detect tripropylamine, lidocaine, and proline. The detection limits (S/N = 3) were 5 x 10(-9) mol.L(-1) for tripropylamine, 1 x 10(-8) mol.L(-1) for lidocaine and 5 x 10(-6) mol.L(-1) for proline, and the linear ranges were from 1.0 x 10(-8) to 1.0 x 10(-5) mol.L(-1) for tripropylamine, 5.0 x 10(-7) mol.L(-1) to 1.0 x 10(-5) mol.L(-1) for lidocaine and 1.0 x 10(-5) to 1.0 x 10(-3) mol.L(-1) for proline, respectively.  相似文献   

14.
Li J  Huang M  Liu X  Wei H  Xu Y  Xu G  Wang E 《The Analyst》2007,132(7):687-691
The electrochemiluminescence (ECL) of tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] ion-exchanged in the sulfonic-functionalized MCM-41 silicas was developed with tripropylamine (TPrA) as a co-reactant in a carbon paste electrode (CPE) using a room temperature ionic liquid (IL) as a binder. The sulfonic-functionalized silicas MCM-41 were used for preparing an ECL sensor by the electrostatic interactions between Ru(bpy)(3)(2+) cations and sulfonic acid groups. We used the IL as a binder to construct the CPE (IL-CPE) to replace the traditional binder of the CPE (T-CPE)--silicone oil. The results indicated that the MCM-41-modified IL-CPE had more open structures to allow faster diffusion of Ru(bpy)(3)(2+) and that the ionic liquid also acted as a conducting bridge to connect TPrA with Ru(bpy)(3)(2+) sites immobilized in the electrode, resulting in a higher ECL intensity compared with the MCM-41-modified T-CPE. Herein, the detection limit for TPrA of the MCM-41-modified IL-CPE was 7.2 nM, which was two orders of magnitude lower than that observed at the T-CPE. When this new sensor was used in flow injection analysis (FIA), the MCM-41-modified IL-CPE ECL sensor also showed good reproducibility. Furthermore, the sensor could also be renewed easily by mechanical polishing whenever needed.  相似文献   

15.
It was found that stannous chloride (SnCl(2)), as a popular inorganic reducing reagent, could obviously enhance the electrochemiluminescence (ECL) of tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3)(2+)) in aqueous solution. Some factors affecting the ECL reactions between Ru(bpy)(3)(2+) and Sn(2+), including pH, concentrations of coreactant, and electrode materials, were investigated by comparison with a classic ECL coreactant tripropylamine (TPA). The Ru(bpy)(3)(2+)-Sn(2+) ECL coreactant system produces stronger and more stable ECL signals, can keep its excellent ECL activity over a wider pH range and has more choices in using electrode materials than the Ru(bpy)(3)(2+)-TPA ECL coreactant system. The ECL mechanism of the Ru(bpy)(3)(2+)-Sn(2+) coreactant system was also studied in detail.  相似文献   

16.
A flow-injection method is reported for the determination of thyroxine based on its enhancement effect on the tris(2,2'-bipyridyl)ruthenium(III) chemiluminescence reaction in the presence of NADH using immobilized alcohol dehydrogenase purified from baker yeast. The limit of detection (3 sigma blank) was 5.0 x 10(-8) M with a sample throughput of 80 h(-1). The calibration graph was linear over the range 0.5 - 10 x 10(-7) M (r2= 0.9988) with the relative standard deviation in the range 1.4 - 3.5% (n = 4). The effect of common excipients used in pharmaceutical preparations, some organic compounds and metal ions was studied. The method was applied to pharmaceutical thyroxine tablets, and the obtained results were not significantly different from the amount quoted.  相似文献   

17.
Costin JW  Barnett NW  Lewis SW 《Talanta》2004,64(4):894-898
Flow injection methodology is described for the determination of proline in red and white wines using tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection. Selective conditions were achieved for proline at pH 10, while other amino acids and wine components did not interfere. The precision of the method was less than 1.00% (R.S.D.) for five replicates of a standard (4 × 10−6 M) and the detection limit was 1 × 10−8 M. The level of proline in white and sparkling wines using the developed methodology was equivalent to those achieved using HPLC-FMOC amino acid analysis. SPE removal of phenolic material was required for red wines to minimize Ru(bipy)33+ consumption and its associated effect on accuracy.  相似文献   

18.
Yin J  Guo W  Du Y  Wang E 《Electrophoresis》2006,27(23):4836-4841
A facile CE method coupled with tris(2,2'-bipyridyl) ruthenium(II)-based electrochemiluminescence [Ru(bpy)(3) (2+)] detection was developed for simultaneous determination of Aconitum alkaloids, i.e., hypaconitine (HA), aconitine (AC), and mesaconitine (MA) in baseline separation. The optimal separation of these Aconitum alkaloids was achieved in a fused-silica capillary column (50 cm x 25 microm id) with 30 mM phosphate solution (pH 8.40) as running buffer at 12 kV applied voltage. The three alkaloids can be determined within 10 min by a single run. The calibration curves showed a linear range from 2.0 x 10(-7) to 2.0 x 10(-5) M for HA, 3.4 x 10(-7) to 1.7 x 10(-5) M for AC, and 3.8 x 10(-7) to 1.9 x 10(-5) M for MA. The RSDs for all analytes were below 3.01%. Good linear relationships were found with correlation coefficients for all analytes exceeding 0.993. The detection limits were 2.0 x 10(-8) M for HA, 1.7 x 10(-7) M for AC, and 1.9 x 10(-7) M for MA under optimal conditions. This method was successfully applied to determine the three alkaloids in Aconitum plants.  相似文献   

19.
20.
Tris(2,2'-bipyridyl)ruthenium(II) electrochemiluminescence (ECL) detection in a capillary electrophoresis separation system was used for the determination of chlorpheniramine (CPM). The experimental conditions, such as the applied potential, separation voltage, injection voltage, injection time and the pH of the separation buffer were considered in detail. The ECL intensity showed two linear responses to CPM, i.e., from 15 microM to 1 mM and from 0.8 microM to 15 microM with a detection limit of 0.5 microM. The binding of CPM with human serum albumin was also monitored using this method and the binding constant was estimated to be 4.1 x 103 M(-1).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号