首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, which has a sensitive area of 80mm×80mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce the discharge and without using protection wires. The detector has been tested with a (55)Fe X-ray source and a 200 MeV/u(12)C beam from CSRm. A position resolution better than 250 μm along the anode wires and a detection efficiency higher than 90% have been achieved.  相似文献   

2.
Plastic scintillation detectors for Time-of-Flight(TOF) measurements are almost essential for event-byevent identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of dimensions50×50×3~t mm~3and 80×100×3~t mm~3have been set up at the External Target Facility(ETF), Institute of Modern Physics(IMP). Their time, energy and position responses are measured with the~(18)O primary beam at 400 Me V/nucleon. After off-line corrections for walk effect and position, the time resolutions of the two detectors are determined to be 27 ps(σ) and 36 ps(σ), respectively. Both detectors have nearly the same energy resolution of3.1%(σ) and position resolution of about 3.4 mm(σ). The detectors have been used successfully in nuclear reaction cross section measurements, and will be be employed for upgrading the RIBLL2 beam line at IMP as well as for the high energy branch at HIAF.  相似文献   

3.
The new beam position monitor (BPM) system of the injector at the upgrade project of the Hefei Light Source (HLS Ⅱ) has 19 stripline beam position monitors. Most consist of four orthogonally symmetric stripline electrodes. Differences in electronic gain and mismachining tolerance can cause changes in the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions, resulting in measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is independent of the beam charge, and the related coefficient can be calculated theoretically. The effect of electrode coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.  相似文献   

4.
RF cold test of a novel C-band cavity beam position monitor (PBM) to be used in the SDUV-FEL Test Facility is described. The test results are presented and some characteristics discussed. The main parameters obtained are in reasonable agreement with the analytical estimations. Effective suppression of the common mode has been demonstrated. The position sensitivity over the test region of ±0.5 mm is about -21.58 dB/10 μm for the TM110 mode and is linear in the central region of the BPM cavity.  相似文献   

5.
The Beijing intense slow positron beam facility is based on the 1.3GeV linac of Beijing Electron-Positron Collider (BEPC) aiming to produce mono-energetic intense slow positron beam for material science investigation. The plugged-in 22Na based slow positron beam section has been newly constructed to supply continuous beam time for the debugging of positron annihilation measurement stations and improve the Beijing intense slow positron beam time using efficiency. Performance testing result of the plugged-in 22Na based slow positron beam facility are reviewed in this paper, with the measurement of the beam transport efficiency, the view of beam spot, the adjustment of beam position, the measurement of beam intensity and energy spread etc. included.  相似文献   

6.
The design of the China Spallation Neutron Source (CSNS) low-energy beam transport (LEBT) line, which locates between the ion source and the radio-frequency quadrupole (RFQ), has been completed with the TRACE3D code. The design aims at perfect matching, primary chopping, a small emittance growth and sufficient space for beam diagnostics. The line consists of three solenoids, three vacuum chambers, two steering magnets and a pre-chopper. The total length of LEBT is about 1.74m. This LEBT is designed to transfer 20mA of H-pulsed beam from the ion source to the RFQ. An induction cavity is adopted as the pre-chopper. The electrostatic octupole steerer is discussed as a candidate. A four-quadrant aperture for beam scraping and beam position monitoring is designed.  相似文献   

7.
Beam emittance is one of the most important parameters for electron sources. To investigate the beam emittance of the 3.5-cell DC-SC photocathode injector developed at Peking University, a multi-slit emittance measurement device has been designed and manufactured. The designed slit width, mask thickness and beamlet drift length are 100 μ m, 3 mm and 430 mm respectively. It is suitable for the electron beam with energy of about 5 MeV and the average current less than 0.1 mA. The preliminary measurement result of the rms emittance of the electron beam produced by the DC-SC injector is about 5-7 mm·mrad.  相似文献   

8.
Ultrasonic phased array technology has been gradually applied to industrial nondestructive testing in recent years. The sound field of the focusing and steering beam radiating from the phased array is a nonuniform distribution in the spatial position so that the echo signals of same size defects will be changed according to defect positions. To analyze these defects quantitatively, a model-based method for the distance amplitude correction is proposed for the phased array system. Based on a non-...  相似文献   

9.
One kind of instantaneous electron beam emittance measurement system based on the optical transition radiation principle and double imaging optical method has been set up. It is mainly adopted in the test for the intense electron-beam produced by a linear induction accelerator. The system features two characteristics. The first one concerns the system synchronization signal triggered by the following edge of the main output waveform from a Blumlein switch. The synchronous precision of about 1 ns between the electron beam and the image capture time can be reached in this way so that the electron beam emittance at the desired time point can be obtained. The other advantage of the system is the ability to obtain the beam spot and beam divergence in one measurement so that the calculated result is the true beam emittance at that time, which can explain the electron beam condition. It provides to be a powerful beam diagnostic method for a 2.5 kA, 18.5 MeV, 90 ns (FWHM) electron beam pulse produced by Dragon I. The ability of the instantaneous measurement is about 3 ns and it can measure the beam emittance at any time point during one beam pulse. A series of beam emittances have been obtained for Dragon I. The typical beam spot is 9.0 mm (FWHM) in diameter and the corresponding beam divergence is about 10.5 mrad.  相似文献   

10.
Great progress was achieved in HIRFL-CSR project in the year of 2003. A large number of components has been completed, tested, installed, and commissioned, especially for the HIRFL-upgrade, for the new injection beam line to the CSRm and for the CSRm. The project is now in the transition from the construction to the installation and commissioning phase. Component delivery and installation is proceeding in accordance with schedule. On the average more than 98% of the components have been contracted. More than 350 magnets have been manufactured. The magnets, the power supplies, the vacuum system and the beam detectors for the injection beam line to the CSRm have been installed. All the magnets for the CSRm have been manufactured  相似文献   

11.
One kind of instantaneous electron beam emittance measurement system based on the optical transition radiation principle and double imaging optical method has been set up. It is mainly adopted in the test for the intense electron-beam produced by a linear induction accelerator. The system features two characteristics. The first one concerns the system synchronization signal triggered by the following edge of the main output waveform from a Blumlein switch. The synchronous precision of about 1 ns between the electron beam and the image capture time can be reached in this way so that the electron beam emittance at the desired time point can be obtained. The other advantage of the system is the ability to obtain the beam spot and beam divergence in one measurement so that the calculated result is the true beam emittance at that time, which can explain the electron beam condition. It provides to be a powerful beam diagnostic method for a 2.5 kA, 18.5 MeV, 90 ns (FWHM) electron beam pulse produced by Dragon I. The ability of the instantaneous measurement is about 3 ns and it can measure the beam emittance at any time point during one beam pulse. A series of beam emittances have been obtained for Dragon I. The typical beam spot is 9.0 mm (FWHM) in diameter and the corresponding beam divergence is about 10.5 mrad.  相似文献   

12.
This paper reports the design and cold test of the cavity beam position monitor (CBPM) for SX-FEL to fulfill tile requirement of beam position measurement resolution of less than 1 p_m, even 0.1 btm. The CBPM was optimized by using a coupling slot to damp the TM010 mode in the output signal. Tile isolation of TM01o mode is about 117 dB, and the shunt impedance is about 200 ~@4.65 GHz with the quality factor 80 from MAFIA simulation and test result. A special antenna was designed to load power for reducing excitation of other modes in the cavity. The resulting output power of TM110 mode was about 90 mV/mm when the source was 6 dBm, and the accomplishable minimum voltage was about 200 btV. The resolution of the CBPM was about 0.1 btm from the linear fitting result based on the cold test.  相似文献   

13.
A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of the relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 μm (σ value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of the detector. The effect was analyzed and the conclusion was reached that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm.  相似文献   

14.
The China Spallation Neutron Source/Rapid Cycling Synchrotron (CSNS/RCS) accelerates a high-intensity proton beam from 80 MeV to 1.6 GeV. Since the beam current and beam power is high, the beam loading is a severe problem for the stability of the circulating beam in the RCS. To study the beam loading effect in the CSNS/RCS theoretically, the RLC circuit model of the rf cavity, the method of Fast Fourier Transform and the method of Laplace transform have been employed to obtain the impedance of the rf system, the beam spectrum and the beam-induced voltage, respectively. Based on these physical models, the beam dynamics equations have been revised and a beam loading model has been constructed in the simulation code ORIENT. By using the code, the beam loading effect on the rf system of the CSNS/RCS has been investigated. Some simulation results have been obtained and conclusions have been drawn.  相似文献   

15.
An investigation of x-ray emission from Cu plasma produced by 1.054 μm Nd:glass laser pulses of 5 ns duration, at 2 × 1012 − 2 × 1013 W cm−2 is reported. The x-ray emission has been studied as a function of target position with respect to the laser beam focus position. It has been observed that x-ray emissions from ns duration plasma show a volume effect similar to subnanosecond plasmas. Due to this effect the x-ray yield increases when target is moved away relative to the best focal plane of the laser beam. This result supports the theoretical model of Tallents and has also been testified independently using suitably modified theoretical model for our experimental conditions. While above result is in good agreement with similar experimental results obtained for sub-nanosecond laser produced plasmas, it differs from result claiming filamentation rather than pure geometrical effect leading to x-ray enhancement for ns plasmas.  相似文献   

16.
郭玉献  徐彭寿 《中国物理 C》2013,37(12):114-118
A small fluctuation of the photon beam position will affect the intensity and polarization characteristics of synchrotron radiation (SR) when it enters an endstation through the related beamline. In this paper, by changing the electron orbit equilibrium position in the vertical direction, we have measured the corresponding changes in the absorption strength of the SR with a gold mesh in different chopper aperture positions. It is found that for three aperture positions, the absorption intensity of the gold mesh shows a good Gaussian distribution as the photon beam position moves, while the ratio of the SR intensity passing through the upper and lower apertures shows a monotonous variation. This suggests a new method for estimating the circular polarization degree of SR originating from the bending magnet based on our current measurement.  相似文献   

17.
DRAGON-I designed and manufactured by CAEP is a linear induction accelerator which can produce a 20 MeV-3 kA-60 ns electron beam. The high performance required for the machine is determined by the beam quality and thus is greatly dependent on the accelerator alignment. In order to reduce the chromatic effect of the beam, the stretched wire technique has been developed to measure magnetic axes of the cells precisely, and the dipole steering magnets have been equipped into each cell to correct its magnetic axis misalignment. Finally, the laser tracker has been used to examine the installation error of the accelerator. In this paper, different alignment techniques and the primary results are presented and discussed.  相似文献   

18.
Design and cold test of a rectangular cavity beam position monitor   总被引:1,自引:0,他引:1  
The CBPM is a kind of monitor which is used for the measurement of beam transverse position. It is becoming increasingly popular due to its high potential in resolution performance. In theory, the resolution can reach about 1 nanometer. In this paper, a rectangular CBPM is designed for it has better X-Y isolation than a cylindrical one. It has been simulated and measured, and the results agree with each other very well. The procedures and results for the simulation and the cold test will be shown later and it will be proved that this is a reliable method for the CBPM design.  相似文献   

19.
A proton therapy facility based on a linac injector and a slow cycling synchrotron is proposed. To achieve effective treatment of cancer, a scanning gantry is required. The flexible transmission of beam and high beam position accuracy are the most basic requirements for a gantry. The designed gantry optics and scanning system are presented. Great efforts are put into studying the sensitivity of the beam position in the isocenter to the element misalignments. It shows that quadrupole shift makes the largest contribution and special attention should be paid to it.  相似文献   

20.
At BSRF we have designed and constructed a four-blade slit for 4W1B XAFS beamline to improve its performance.The slit also functions as a beam position monitor by detecting the signal of photoemission from the blades.The key features of this design are:(1) adopting a new mechanism for blade adjustment;(2) combining the functions of two types of BPM (the single wire monitor and the double blade monitor) with the slit.Those features enable us firstly to accurately align the slit with the center of the beam,secondly to monitor the stability of the beam position during operation,and thirdly to diagnose the beam characteristics with this single device.The principle,the features and the testing results are presented in the following sections.2001 Elsevier Science B.V.All rights reserved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏