首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The possibility of using polymer mixtures with different chemical compositions as a DNA sequencing matrix by capillary electrophoresis (CE) has been exploited. Polyacrylamide (PAM, 2.5%, w/v) having a molecular mass of 2.2 x 10(6) has been mixed with poly(N,N-dimethylacrylamide) (PDMA) having molecular masses of 8000, 470000 and 2.1 x 10(6) at concentrations of 0.2, 0.5 and 1% (w/v). Unlike polymer mixtures of the same polymer with different molecular masses, the use of polymer mixtures with different chemical compositions encounters an incompatibility problem. It was found that the incompatibility increased with increasing PDMA molecular mass and PDMA concentration, which resulted in decreased efficiency in DNA sequencing. Also, the incompatibility had a more pronounced effect on the efficiency as the base number was increased. However, by choosing a low-molecular-mass PDMA of 8000 and a low concentration of 0.2% (w/v), the incompatibility of PAM and PDMA has been alleviated. At the same time, the advantage of using polymer mixtures revealed a higher efficiency for such a polymer mixture when compared with PAM. The mixture also endowed the separation medium with a dynamic coating ability. An efficiency of over 10 x 10(6) theoretical plates per meter has been achieved by using the bare capillaries without the additional chemical coating step.  相似文献   

2.
Song L  Liang D  Fang D  Chu B 《Electrophoresis》2001,22(10):1987-1996
Poly(N,N-dimethylacrylamide) (PDMA) with a molecular mass of 5.2 x 10(6) g/mol has been synthesized and used in DNA sequencing analysis by capillary electrophoresis (CE). A systematic investigation is presented on the effects of different separation conditions, such as injection amount, capillary inner diameter, polymer concentration, effective separation length, electric field and temperature, on the resolution. DNA sequencing up to 800 bases with a resolution (R) limit of 0.5 (and 1,000 bases with a resolution limit of 0.3) and a migration time of 96 min was achieved by using 2.5% w/v polymer, 150 V/cm separation electric field, and 60 cm effective separation length at room temperature on a DNA sample prepared with FAM-labeled--21M13 forward primer on pGEM3Zf(+) and terminated with ddCTP. Ultrafast and fast DNA sequencing up to 420 and 590 bases (R > or = 0.5) were also achieved by using 3% w/v polymer and 40 cm effective separation length with a separation electric field of 525 and 300 V/cm, and a migration time of 12.5 and 31.5 min, respectively. PDMA has low viscosity, long shelf life and dynamic coating ability to the glass surface. The unique properties of PDMA make it a very good candidate as a separation medium for large-scale DNA sequencing by capillary array electrophoresis (CAE).  相似文献   

3.
Wang Y  Liang D  Hao J  Fang D  Chu B 《Electrophoresis》2002,23(10):1460-1466
A noncross-linked interpenetrating polymer network (IPN), consisting of poly(N,N-dimethylacrylamide) (PDMA) and polyvinylpyrrolidone (PVP, weight-average molecular weight M(w) = 1 x 10(6) g/mol) was synthesized by polymerizing N,N-dimethylacrylamide (DMA) monomers directly in PVP buffer solution and tested as a separation medium for double-stranded (ds)DNA analysis without further purification. Due to the incompatibility of PVP and PDMA, a simple solution mixture could incur a microphase separation and showed poor performance on dsDNA separation. However, a dramatic improvement was achieved by the formation of an IPN. We attributed the high sieving ability of IPN as due to an increase in the number of entanglements by the more extended polymer chains. Apparent viscosity studies showed that the IPN had a much higher viscosity than the simple mixture containing the same amount of PDMA and PVP. In 1 x Tris-borate-EDTA (TBE) buffer, the concentration ratio of PDMA and PVP had a great effect on the DNA separation. At optimal conditions, the 22 fragments in pBR322/HaeIII DNA were successfully separated within 15 min, with a resolution of better than 1.0 for 123/124 bp.  相似文献   

4.
Zhou D  Wang Y  Zhang W  Yang R  Shi R 《Electrophoresis》2007,28(7):1072-1080
In order to further improve ssDNA sequencing performances using quasi-interpenetrating network (quasi-IPN) as a matrix composed of linear polyacrylamide (LPA) with lower viscosity-average molecular mass (3.3 MDa) and poly(N,N-dimethylacrylamide) (PDMA), gold nanoparticles (GNPs) were prepared and added into this quasi-IPN to form polymer/metal composite sieving matrices. The studies of intrinsic viscosity and differential scanning calorimetry (DSC) on quasi-IPN and quasi-IPN/GNPs indicate that there were interactions between GNPs and polymer chains. The sequencing performances on ssDNA using quasi-IPN and quasi-IPN/GNPs (with different GNPs concentrations) as sieving matrices were studied and compared by CE at different temperatures. The results show that resolutions of quasi-IPN/GNPs were higher than those of quasi-IPN without GNPs and approximated those of quasi-IPN composed of LPA with higher MW (6.5 MDa) and PDMA without GNPs in the bare fused-silica capillaries. Furthermore, the sequencing time of quasi-IPN/GNPs was shorter than that of quasi-IPN under the same sequencing conditions. The influences of GNPs and sequencing temperature on the sequencing performances of ssDNA were also discussed. The separation reproducibility of quasi-IPN/GNPs solution was excellent and its shelf life was more than 8 months.  相似文献   

5.
Gao F  Tie C  Zhang XX  Niu Z  He X  Ma Y 《Journal of chromatography. A》2011,1218(20):3037-3041
The separation and sequencing of DNA are the main objectives of the Human Genome Project, and this project has also been very useful for gene analysis and disease diagnosis. Capillary electrophoresis (CE) is one of the most common techniques for the separation and analysis of DNA. DNA separations are usually achieved using capillary gel electrophoresis (CGE) mode, in which polymer gel is packed into the capillary. Compared with a traditional CGE matrix, a hydrophilic polymer matrix, which can be adsorb by the capillary wall has numerous advantages, including stability, reproducibility and ease of automation. Various water-soluble additives, such as linear poly(acrylamide) (PAA) and poly(N,N-dimethylacrylamide) (PDMA), have been employed as media. In this study, different star-shaped PDMA polymers were designed and synthesized to achieve lower polymer solution viscosity. DNA separations with these polymers avoid the disadvantages of high viscosity and long separation time while maintaining high resolution (10 bp between 271 bp and 281 bp). The influences of the polymer concentration and structure on DNA separation were also determined in this study; higher polymer concentration yielded better separation performance, and star-like polymers were superior to linear polymers. This work indicates that modification of the polymer structure is a potential strategy for optimizing DNA separation.  相似文献   

6.
Quasi‐interpenetrating network (quasi‐IPN) of linear polyacrylamide (LPA) with low molecular mass and poly(N,N‐dimethylacrylamide) (PDMA), which is shown to uniquely combine the superior sieving ability of LPA with the coating ability of PDMA, has been synthesized for application in dsDNA and basic protein separation by CE. The performance of quasi‐IPN on dsDNA separation was determined by polymer concentration, electric field strength, LPA molecular masses and different acrylamide (AM) to N,N‐dimethylacrylamide (DMA) ratio. The results showed that all fragments in Φ×174/HaeIII digest were achieved with a 30 cm effective capillary length at –6 kV at an appropriate polymer solution concentration in bare silica capillaries. Furthermore, EOF measurement results showed that quasi‐IPN exhibited good capillary coating ability, via adsorption from aqueous solution, efficiently suppressing EOF. The effect of the buffer pH values on the separation of basic proteins was investigated in detail. The separation efficiencies and analysis reproducibility demonstrated the good potentiality of quasi‐IPN matrix for suppressing the adsorption of basic proteins onto the silica capillary wall. In addition, when quasi‐IPN was used both as sieving matrix and dynamic coating in bare silica capillaries, higher peak separation efficiencies, and better migration time reproducibility were obtained.  相似文献   

7.
Zhou D  Wang Y  Yang R  Zhang W  Shi R 《Electrophoresis》2007,28(17):2998-3007
Gold nanoparticles (GNPs) with particle sizes of about 20, 40, and 60 nm were prepared and added into a quasi-interpenetrating network (quasi-IPN) composed of linear polyacrylamide (LPA) with different viscosity-average molecular masses of 1.5, 3.3, and 6.5 MDa and poly-N,N-dimethylacrylamide (PDMA) to form polymer/metal composite matrices, respectively. These novel matrices could improve ssDNA sequencing performances due to interactions between GNPs and polymer chains and the formation of physical cross-linking points as demonstrated by intrinsic viscosities and glass transition temperatures. The effects of the parameters in relation to quasi-IPN/GNPs matrices, such as GNP contents, GNP particle sizes, LPA molecular masses, and solution concentrations, on ssDNA sequencing performances were studied. In the presence of GNPs, the separation had the advantages of high resolution, speediness, excellent reproducibility, long shelf life and easy automation. Therefore, less viscous matrix solutions (with moderate size GNPs) due to lower solution concentration and lower-molecular-mass LPA could be used to replace more viscous solutions (without GNPs) due to higher solution concentration or higher-molecular-mass LPA to separate DNA, while the sieving performances were approximate even higher, which helped to achieve full automation especial for capillary array electrophoresis (CAE) and microchip electrophoresis (MCE).  相似文献   

8.
To elucidate the impact of matrix chemical and physical properties on DNA sequencing separations by capillary electrophoresis (CE), we have synthesized, characterized and tested a controlled set of different polymer formulations for this application. Homopolymers of acrylamide and N,N-dimethylacrylamide (DMA) and copolymers of DMA and N,N-diethylacrylamide (DEA) were synthesized by free radical polymerization and purified. Polymer molar mass distributions were characterized by tandem gel permeation chromatography - laser light scattering. Polymers with different chemical compositions and similar molar mass distributions were selected and employed at the same concentration so that the variables of comparison between them were hydrophobicity and average coil size in aqueous solution. We find that the low-shear viscosities of 7% w/v polymer solutions decrease by orders of magnitude with increasing polymer hydrophobicity, while hydrophilic polymers exhibit more pronounced reductions in viscosity with increased shear. The performance of the different matrices for DNA sequencing was compared with the same sample under identical CE conditions. The longest read length was produced with linear polyacrylamide (LPA) while linear poly-N,N-dimethylacrylamide (PDMA) gave approximately 100 fewer readable bases. Read lengths with DMA/DEA copolymers were lower, and decreased with increasing DEA content. This study highlights the importance of polymer hydrophilicity for high-performance DNA sequencing matrices, through the formation of robust, highly-entangled polymer networks and the minimization of hydrophobic interactions between polymers and fluorescently-labeled DNA molecules. However, the results also show that more hydrophobic matrices offer much lower viscosities, enabling easier microchannel loading at low applied pressures.  相似文献   

9.
Dan Zhou 《Talanta》2009,80(1):195-201
A new matrix additive, poly (N,N-dimethylacrylamide)-functionalized gold nanoparticle (GNP-PDMA), was prepared by “grafting-to” approach, and then incorporated into quasi-interpenetrating network (quasi-IPN) composed of linear polyacrylamide (LPA, 3.3 MDa) and PDMA to form novel polymer/metal composite sieving matrix (quasi-IPN/GNP-PDMA) for DNA sequencing by capillary electrophoresis. Without complete optimization, quasi-IPN/GNP-PDMA yielded a readlength of 801 bases at 98% accuracy in about 64 min by using the ABI 310 Genetic Analyzer at 50 °C and 150 V/cm. Compared with previous quasi-IPN/GNPs, quasi-IPN/GNP-PDMA can further improve DNA sequencing performances. This is because the presence of GNP-PDMA can improve the compatibility of GNPs with the whole sequencing system, enhance the entanglement degree of networks, and increase the GNP concentration in system, which consequently lead to higher restriction and stability, higher apparent molecular weight (MW), and smaller pore size of the total sieving networks. Furthermore, the composite matrix was also compared with quasi-IPN containing higher-MW LPA and commercial POP-6. The results indicate that the composite matrix is a promising one for DNA sequencing to achieve full automation due to the separation provided with high resolution, speediness, excellent reproducibility, and easy loading in the presence of GNP-PDMA.  相似文献   

10.
Read length in DNA sequencing by capillary electrophoresis at elevated temperatures is shown to be greatly affected by the extent of hydrophobicity of the polymer separation matrix. At column temperatures of up to 80 degrees C, hydrophilic linear polyacrylamide (LPA) provides superior read length and separation speed compared to poly(N,N-dimethylacrylamide) (PDMA) and a 70:30 copolymer of N,N-dimethylacrylamide and N,N-diethylacrylamide (PDEA30). DNA-polymer and polymer intramolecular interactions are presumed to be a major cause of band broadening and the subsequent loss of separation efficiency with the more hydrophobic polymers at higher column temperatures. With LPA, these interactions were reduced, and a read length of 1000 bases at an optimum temperature of 70 degrees -75 degrees C was achieved in less than 59 min. By comparison, PDMA produced a read length of roughly 800 bases at 50 degrees C, which was close to the read length attained in LPA at the same temperature; however, the migration time was approximately 20% longer, mainly because of the higher polymer concentration required. At 60 degrees C, the maximum read length was 850 bases for PDMA, while at higher temperatures, read lengths for this polymer were substantially lower. With the copolymer DEA30, read length was 650 bases at the optimum temperature of 50 degrees C. Molecular masses of these polymers were determined by tandem gel permeation chromatography-multiangle laser light scattering method (GPC-MALLS). The results indicate that for long read, rapid DNA sequencing and analysis, hydrophilic polymers such as LPA provide the best overall performance.  相似文献   

11.
A replaceable polymer matrix, based on the novel monomer N-hydroxyethylacrylamide (HEA), has been synthesized for application in DNA separation by microchannel electrophoresis. The monomer was found by micellar electrokinetic chromatography analysis of monomer partitioning between water and 1-octanol to be more hydrophilic than acrylamide and N,N-dimethylacrylamide. Polymers were synthesized by free radical polymerization in aqueous solution. The weight-average molar mass of purified polymer was characterized by tandem gel permeation chromatography-multiangle laser light scattering. The steady-shear rheological behavior of the novel DNA sequencing matrix was also characterized, and it was found that the viscosity of the novel matrix decreases by more than 2 orders of magnitude as the shear rate is increased from 0.1 to 1000 s(-1). Moreover, in the shear-thinning region, the rate of change of matrix viscosity with shear rate increases with increasing polymer concentration. Poly-N-hydroxyethylacrylamide (PHEA) exhibits good capillary-coating ability, via adsorption from aqueous solution, efficiently suppressing electroosmotic flow (EOF) in a manner comparable to that of poly-N,N-dimethylacrylamide. Under DNA sequencing conditions, adsorptive PHEA coatings proved to be stable and to maintain negligible EOF for over 600 h of electrophoresis. Resolution of DNA sequencing fragments, particularly fragments > 500 bases, in PHEA matrices generally improves with increasing polymer concentration and decreasing electric field strength. When PHEA is used both as a separation matrix and as a dynamic coating in bare silica capillaries, the matrix can resolve over 620 bases of contiguous DNA sequence within 3 h. These results demonstrate the good potential of PHEA matrices for high-throughput DNA analysis by microchannel electrophoresis.  相似文献   

12.
Sparsely cross-linked "nanogels" for microchannel DNA sequencing   总被引:1,自引:0,他引:1  
Doherty EA  Kan CW  Barron AE 《Electrophoresis》2003,24(24):4170-4180
We have developed sparsely cross-linked "nanogels", sub-colloidal polymer structures composed of covalently linked, linear polyacrylamide chains, as novel DNA sequencing matrices for capillary electrophoresis. The presence of covalent cross-links affords nanogel matrices with enhanced network stability relative to standard, linear polyacrylamide (LPA), improving the separation of large DNA fragments. Nanogels were synthesized via inverse emulsion (water-in-oil) copolymerization of acrylamide and N,N-methylenebisacrylamide (Bis). In order to retain the fluidity necessary in a replaceable polymer matrix for capillary array electrophoresis (CAE), a low percentage of the Bis cross-linker (< 10(-4) mol%) was used. Nanogels were characterized by multiangle laser light scattering and rheometry, and were tested for DNA sequencing by CAE with four-color laser-induced fluorescence (LIF) detection. The properties and performance of nanogel matrices were compared to those of a commercially available LPA network, which was matched for both weight-average molar mass (Mw) and extent of interchain entanglements (c/c*). Nanogels presented in this work have an average radius of gyration of 226 nm and a weight-average molar mass of 8.8 x 10(6) g/mol. At concentrations above the overlap threshold, nanogels form a clear, viscous solution, similar to the LPA matrix (Mw approximately 8.9 x 10(6) g/mol). The two matrices have similar flow and viscosity characteristics. However, because of the physical network stability provided by the internally cross-linked structure of the nanogels, a substantially longer read length ( approximately 63 bases, a 10.4% improvement) is obtained with the nanogel matrix at 98.5% accuracy of base-calling. The nanogel network provides higher-selectivity separation of ssDNA sequencing fragments longer than 375 bases. Moreover, nanogel matrices require 30% less polymer per unit volume than LPA. This is the first report of a sequencing matrix that provides better performance than LPA, in a side-by-side comparison of polymer matrices matched for Mw and extent of interchain entanglements.  相似文献   

13.
Replaceable sieving polymers are the fundamental component for high‐resolution nucleic acids separation in CE. The choice of polymer and its physical properties play significant roles in influencing separation performance. Recently, reversible addition fragmentation chain transfer (RAFT) polymerization has been shown to be a versatile polymerization technique capable of yielding well‐defined polymers previously unattainable by conventional free‐radical polymerization. In this study, a high molecular weight poly‐(N,N‐dimethylacrylamide) (PDMA) at 765 000 gmol?1 with a polydispersity index of 1.55 was successfully synthesized with the use of chain transfer agent—2‐propionic acidyl butyl trithiocarbonate in a multistep sequential RAFT polymerization approach. This study represents the first demonstration of RAFT polymerization for synthesizing polymers with the molecular weight range suitable for high‐resolution DNA separation in sieving electrophoresis. Adjustment of pH in the reaction was found to be crucial for the successful RAFT polymerization of high molecular weight polymer as the buffered condition minimizes the effect of hydrolysis and aminolysis commonly associated with trithiocarbonate chain transfer agents. The separation efficiency of 2‐propionic acidyl butyl trithiocarbonate PDMA was found to have marginally superior separation performance compared to a commercial PDMA formulation, POP?‐CAP, of similar molecular weight range.  相似文献   

14.
Buchholz BA  Barron AE 《Electrophoresis》2001,22(19):4118-4128
The ability of a polymer matrix to separate DNA by capillary electrophoresis (CE) is strongly dependent upon polymer physical properties. In particular, recent results have shown that DNA sequencing performance is very sensitive to both the average molar mass and the average coil radius of the separation matrix polymers, which are affected by both polymer structure and polymer-solvent affinity. Large polymers with high average molar mass provide the best DNA sequencing separations for CE, but are also the most challenging to characterize with accuracy. The methods most commonly used for the characterization of water-soluble polymers with application in microchannel electrophoresis have been gel permeation chromatography (GPC) and intrinsic viscosity measurements, but the limitations and potential inaccuracies of these approaches, particularly for large or novel polymers and copolymers, press the need for a more universally accurate method of polymer molar mass profiling for advanced DNA separation matrices. Here, we show that multi-angle laser light scattering (MALLS) measurements, carried out either alone or in tandem with prior on-line sample fractionation by GPC, can provide accurate molar mass and coil radius information for polymer samples that are useful for DNA sequencing by CE. Wider employment of MALLS for characterization of novel polymers designed as DNA separation matrices for microchannel electrophoresis should enable more rapid optimization of matrix properties and formulation, and assist in the development of novel classes of polymer matrices.  相似文献   

15.
Copolymers of acrylamide (AM) and N,N-dimethylacrylamide (DMA) with AM to DMA molar ratios of 3:1, 2:1 and 1:1 and molecular weights of about 2.2 MDa were synthesized. The polymers were tested as separation media in DNA sequencing analysis by capillary electrophoresis (CE). The dynamic coating ability of polydimethylacrylamide (PDMA) and the hydrophilicity of polyacrylamide (PAM) have been successfully combined in these random copolymers. A separation efficiency of over 10 million theoretical plates per meter has been reached by using the bare capillaries without the additional polymer coating step. Under optimized separation conditions for longer read length DNA sequencing, the separation ability of the copolymers decreased with decreasing AM to DMA molar ratio from 3:1, 2:1 and 1:1. In comparison with PAM, the copolymer with a 3:1 AM:DMA ratio showed a higher separation efficiency. By using a 2.5% w/v copolymer with 3:1 AM:DMA ratio, one base resolution of 0.55 up to 699 bases and 0.30 up to 963 bases have been achieved in about 80 min at ambient temperatures.  相似文献   

16.
A thermo-responsive separation matrix, consisting of Pluronic F127 tri-block copolymers of poly(ethylene oxide) and poly(propylene oxide), was used to separate DNA fragments by microchip electrophoresis. At low temperature, the polymer matrix was low in viscosity and allowed rapid loading into a microchannel under low pressure. With increasing temperatures above 25°C, the Pluronic F127 solution forms a liquid crystalline phase consisting of spherical micelles with diameters of 17–19 nm. The solution can be used to separate DNA fragments from 100 bp to 1500 bp on poly(methyl methacrylate) (PMMA) chips. This temperature-sensitive and viscosity-tunable polymer provided excellent resolution over a wide range of DNA sizes. Separation is based on a different mechanism compared with conventional matrices such as methylcellulose. To illustrate the separation mechanism of DNA in a Pluronic F127 solution, DNA molecular imaging was performed by fluorescence microscopy with F127 polymer as the separation matrix in microchip electrophoresis. Figure Temperature dependence of the viscosity of 20% w/w Pluronic F127 solution in 1xTBE buffer. Dotted approximates resultant curve.  相似文献   

17.
Poor compatibility was the major drawback of polymer mixtures when used as DNA separation media. Using poly(ethylene oxide)‐b‐poly(N, N‐dimethylacrylamide) (PEO44b‐PDMA88) and PEO (Mw: 1.3 MDa) as an example, we demonstrated the concept that the compatibility was significantly improved when mixing a homopolymer with its copolymer. Laser light scattering indicated that the major interaction between PEO and PEO‐b‐PDMA in dilute solution was the weak hydrodynamic interaction, which showed almost no effect on the viscosity and the static scattering pattern. In semidilute or concentrated solution, viscosity measurement also suggested good compatibility between the two components. When tested as DNA separation medium by CE, the viscosity of the mixture was extremely low, only 5 cP for 5.0 m/v% PEO‐b‐PDMA+0.1 m/v% PEO at 25°C. The performance on DNA separation could be tuned by varying the concentration of each component as well as the component ratio. Good separation on both dsDNA and ssDNA was achieved.  相似文献   

18.
Kan CW  Barron AE 《Electrophoresis》2003,24(1-2):55-62
We present a "proof-of-concept" study showing that a blend of thermo-responsive and nonthermo-responsive polymers can be used to create a DNA sieving matrix with a thermally tunable mesh size, or "dynamic porosity". Various blends of two well-studied sieving polymers for CE, including hydroxypropylcellulose (HPC), a thermo-responsive polymer, and hydroxyethylcellulose (HEC), a nonthermo-responsive polymer, were used to separate a double-stranded DNA restriction digest (Phi X174-HaeIII). HPC exhibits a volume-phase transition in aqueous solution which results in a collapse in polymer coil volume at approximately 39 degrees C. Utilizing a blend of HPC and HEC in a ratio of 1:5 by weight, we investigated the effects of changing mesh size on DNA separation, as controlled by temperature. High-resolution DNA separations were obtained with the blended matrix at temperatures ranging from 25 degrees C to 38 degrees C. We evaluated changes in the selectivity of DNA separation with increasing temperature for certain pairs of small and large fragments. A pure HEC (nonthermo-responsive) matrix was used over the same temperature range as a negative control. In the blended matrix, we observe a maximum in selectivity at approximately 31 degrees C for small DNA, while a significant increase in the selectivity of large-DNA separation occurs at approximately 36 degrees C as the polymer mesh "opens". We also demonstrate, through a temperature ramping experiment, that this matrix can be utilized to obtain high-resolution separation of both small and large DNA fragments simultaneously in a single CE run. Blended polymer matrices with "dynamic porosity" have the potential to provide enhanced genomic analysis by capillary array or microchip electrophoresis in microfluidic devices with advanced temperature control.  相似文献   

19.
王延梅 《高分子科学》2013,31(4):691-701
A series of double-hydrophilic double-grafted PMA-g-PEG/PDMA copolymers, which contained poly(methacrylate) (PMA) as backbone, poly(ethylene glycol) (PEG) and poly(N,N-dimethylacrylamide) (PDMA) as side chains synthesized successfully by using reversible addition-fragmentation chain transfer (RAFT) polymerization and atom transfer radical polymerization (ATRP), were used as physical coatings for the evaluation of protein-resistant properties by capillary electrophoresis (CE). Electroosmotic flow (EOF) measurement results showed that the PMA-g-PEG/PDMA copolymer coated capillaries could suppress electroosmotic mobility in a wide pH range (pH = 2.8–9.8) and EOF mobility decreased with the increase of copolymer molecular mass and PDMA content. At the same time, protein recovery, theoretical plate number of separation and repeatability of migration time demonstrated that antifouling efficiency was improved with the increase of molecular mass and PEG content.  相似文献   

20.
Kan CW  Doherty EA  Barron AE 《Electrophoresis》2003,24(24):4161-4169
We have developed a novel class of thermogelling polymer networks based on poly-N-alkoxyalkylacrylamides, and demonstrated their use as DNA sequencing matrices for high-throughput microchannel electrophoresis in capillary arrays. Polymers and copolymers of N-ethoxyethylacrylamide (NEEA) and N-methoxyethylacrylamide (NMEA) were synthesized by aqueous-phase free-radical polymerization and characterized by tandem gel permeation chromatography-multi-angle laser light scattering. These copolymer matrices exhibit "re-entrant"-type volume phase transitions, forming entangled networks with high shear viscosity at low (< 20 degrees C) and high (> 35 degrees C) temperatures, and undergoing a "coil-to-globular", lower critical solution temperature (LCST)-like phase transition over an intermediate temperature range (20-35 degrees C). Hence, matrix viscosity is relatively low at room temperature (25 degrees C), and increases rapidly above 35 degrees C. The material properties and phase behavior of these thermogelling polymer networks were studied by steady-shear rheometry. These matrices are easily loaded into capillary arrays at room temperature while existing as viscous fluids, but thermogel above 35 degrees C to form transparent hydrogels via a thermo-associative phase transition. The extent of the intermediate viscosity drop and the final viscosity increase depends on the composition of the copolymers. DNA sequencing by capillary array electrophoresis with four-color laser-induced fluorescence (LIF) detection shows that these thermogelling networks provide enhanced resolution of both small and large DNA sequencing fragments and longer sequencing read lengths, in comparison to appropriate control (closely related, nonthermogelling) polymer networks. In particular, a copolymer comprised of 90% w/w NMEA and 10% w/w NEEA, with a molecular mass of approximately 2 MDa, delivers around 600 bases at 98.5% base-calling accuracy in 100 min of electrophoresis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号