首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The fungicides vinclozolin and iprodione are widely used in agriculture. These pesticides are dicarboximide fungicides containing the common moiety 3,5-dichloroaniline (3,5-DCA). It has been suggested that low-level exposures to such compounds may be associated with adverse health effects such as endocrine disruption. In this study a method using liquid chromatography/triple quadrupole mass spectrometry (LC/MS/MS) was developed for the analysis of 3,5-DCA as a biomarker of exposure to these fungicides in human urine. The urine samples were treated by basic hydrolysis to degrade the fungicides, their metabolites and conjugates to 3,5-DCA. The 3,5-DCA was then extracted using toluene and derivatized using pentafluoropropionic anhydride (PFPA). Analysis of the derivative was carried out using selected reaction monitoring (SRM) in the negative ion mode. Quantification of the derivative was performed using [(13)C(6)]-labeled 3,4-DCA as an internal standard with good precision and linearity in the range 0.1-200 ng/mL urine. The limit of detection was determined to be 0.1 ng/mL. The metabolites in urine were found to be stable during storage at -20 degrees C. To validate 3,5-DCA as a biomarker the method was applied in a human experimental exposure to iprodione and vinclozolin. Two healthy volunteers received 200 microg single oral doses of each pesticide followed by urine sampling during 72-120 h post-exposure. Between 78-107% of the dose was recovered as 3,5-DCA in the urine after exposure.  相似文献   

2.
Phenoxyacetic acids are widely used herbicides. The toxicity of phenoxyacetic acids is debated, but high-level exposure has been shown to be hepatotoxic as well as nephrotoxic in animal studies. An inter-species difference in toxic effects has been found, with dogs particularly susceptible. In this study a method using liquid chromatography/triple quadrupole mass spectrometry (LC/MS/MS) is described for the analysis of 4-chloro-2-methylphenoxyacetic acid (MCPA), and its metabolite 4-chloro-2-hydroxymethylphenoxyacetic acid (HMCPA), 2,4-dichlorophenoxyacetic acid (2,4-D), and 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) in human urine. The urine samples were treated by acid hydrolysis to degrade possible conjugations. The sample preparation was performed using solid-phase extraction. Analysis was carried out using selected reaction monitoring (SRM) in the negative ion mode. Quantification of the phenoxyacetic acids was performed using [(2)H(3)]-labeled MCPA and 2,4-D as internal standards. The method was linear in the range 0.05-310 ng/mL urine and has a within-run precision of 2-5%. The between-run precision in lower concentration ranges was between 6-15% and between 2-8% in higher concentration ranges. The limit of detection was determined to 0.05 ng/mL. The metabolites in urine were found to be stable during storage at -20 degrees C. To validate the phenoxyacetic acids as biomarkers of exposure, the method was applied in a human experimental oral exposure to MCPA, 2,4-D and 2,4,5-T. Two healthy volunteers received 200 microg of each phenoxyacetic acid in a single oral dose followed by urine sampling for 72 h post-exposure. After exposure, between 90 and 101% of the dose was recovered in the urine. In the female subject, 23%, and in the male subject 17%, of MCPA was excreted as HMCPA.  相似文献   

3.
4.
5.
6.
李上富  向丽  蔡宗苇 《色谱》2017,35(1):80-85
建立了一种基于母离子扫描模式的超高效液相色谱-三重四极杆质谱检测尿液中酰基肉碱的分析方法。对酰基肉碱类化合物所共有的m/z为60、85和144的碎片离子进行选择性检测,结合化合物母离子扫描的结果及其对应的保留时间,选取一致性较好的化合物进行筛选,再利用高分辨质谱确认,最终检测到37种酰基肉碱化合物,其中有14种尚未被HMDB和LIPID MAPS数据库收录。该方法可应用于其他生物样本(如血液、组织)中酰基肉碱的定性、定量分析,可作为检测酰基肉碱化合物的新选择。  相似文献   

7.
A rapid and inexpensive multiresidue method for determining pesticides in fruits and vegetables is presented. Extraction of a 15 g sample with 15 mL acetonitrile was followed by buffering with magnesium sulfate, sodium chloride, sodium citrate dihydrate, and disodium citrate. Acidification with formic acid prior to dispersive cleanup with aminopropyl sorbent and magnesium sulfate was used to stabilize base-sensitive pesticides such as chlorothalonil. Extracts were concentrated to 2 g/mL. Analyses were conducted by GC/ion trap detector MS, GC-halogen-specific detector, and LC/triple quadrupole MS. Accuracy and repeatability for 166 compounds in tomato, potato, and cabbage were 70-120% and <20% CV in 85% of the compounds, respectively. Reproducibility over a 4 month period in multiple commodities and analytical conditions was 62-124%, with CVs better than 30% for 91% of the compounds. Supply cost/sample was reduced 66%, and time to extract a batch of 24 samples was reduced by half compared to the prior method that used a 50 g sample, 100 mL acetonitrile, multiple SPE columns, and additional instrumentation. Additional extraction studies were conducted in tomatoes, oranges, and green beans at 4 g/mL using a GC/MS triple quadrupole system with a programmable temperature vaporization inlet. Recoveries of 70-120% were achieved in 93% of all compounds in green beans, 95% in tomatoes, and 97% in oranges.  相似文献   

8.
9.
张续  邱天  付慧  杨艳伟  赵峰  林少彬  胡小键 《色谱》2018,36(9):895-903
建立了人尿中9种邻苯二甲酸酯(PAE)代谢物的超高效液相色谱-三重四极杆质谱(UPLC-MS/MS)测定方法。2 mL尿液样本酶解2 h后,经强阴离子固相萃取净化处理;选用Waters ACQUITY UPLC BEH Phenyl色谱柱(100 mm×2.1 mm,1.7 μ m),以0.1%(体积分数)乙酸乙腈和0.1%(体积分数)乙酸水溶液为流动相进行梯度洗脱;在负离子电喷雾多反应监测模式(MRM)下测定9种PAE代谢物含量。8种PAE代谢物在0.39~200 μ g/L范围内、1种PAE代谢物在1.17~600 μ g/L范围内线性关系良好,相关系数均大于0.995。方法检出限为0.06~0.85 μ g/L,定量限为0.20~2.80 μ g/L。3个加标水平的加标回收率为84.1%~122%,精密度为4.5%~14.3%;日内精密度不高于9.3%,日间精密度不高于10.1%;基质效应和稳定性符合分析要求。应用该方法测定50份人尿液样本,邻苯二甲酸单环已酯(MCHP)和邻苯二甲酸单苄酯(MBZP)的检出率分别为0和44.0%,其余7种PAE代谢物的检出率为100%。该方法操作简单、定量准确、稳定性好,适用于人尿中9种PAE代谢物的定量分析。  相似文献   

10.
Using hyphenated analytical techniques, gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), a study on minor propofol metabolites in human urine was conducted. These techniques allowed identification of two new phase I metabolites (2-(omega-propanol)-6-isopropylphenol and 2-(omega-propanol)-6-isopropyl-1,4-quinol). In addition, their four corresponding conjugates (three glucuronides and one sulphate) were detected. Thus in human urine at least eight conjugate metabolites are produced, derived from four different aglycones (propofol; 2, 6-diisopropyl-1,4-quinol; 2-(omega-propanol)-6-isopropylphenol and 2-(omega-propanol)-6-isopropyl-1,4-quinol).  相似文献   

11.
12.
As a suitable way for routine screening of pesticides and control of other organic contaminants in water, the combination of liquid chromatography triple quadrupole tandem mass spectrometry (LC–QqQ-MS/MS) and liquid chromatography–hybrid quadrupole time-of-flight mass spectrometry (LC–QTOF-MS) has been applied to the analysis of 63 surface and waste water samples after conventional solid-phase extraction (SPE). The extracts were screened for 43 pesticides or degradation products by LC–QqQ-MS/MS achieving limits of detection (LOD) ranged from 0.04 to 2 ng L−1. Of the 43 selected pesticides, 33 were detected in water samples. The ESI–QTOF MS instrument was run using two simultaneous acquisition functions with low and high collision energy (MSE approach) and acquiring the full mass spectra. A home-made database containing more than 1100 organic pollutants was used for substance identification. Around 250 of these compounds were available at the laboratory as reference standards. Five pesticides and 3 of their degradation products, different to those selected in the QqQ method, were detected by QqTOF-MS. Thirteen pharmaceuticals and two drugs of abuse were also identified in the samples. In practice, the sample preparation proved to be suitable for both techniques and for a wide variety of substances with different polarity. Mutual confirmation and evidence of co-occurrence of several other organic contaminants were the main advantages of the combination of both techniques.  相似文献   

13.
Terbuthylazine (TBA) is a widely applied herbicide and an environmental contaminant. Following its use, humans, such as agricultural workers and rural residents, may be exposed. An isotope-dilution liquid chromatography coupled to electrospray-tandem mass spectrometry method for the determination of TBA, and its metabolite desethylterbuthylazine (DET) in human urine and hair was developed and validated. Under the optimised conditions, analytes were extracted from urine using a solid phase cartridge or from hair by sonication in methanol. Analytes were separated using a C18 reversed-phase chromatographic column and quantified, after positive ionization using a heated electrospray source, by a triple quadrupole mass detector in the selected reaction monitoring mode. Validation showed linear dynamic ranges up to 100 μg/L or 5.00 ng/mg hair, inter- and intra-run precisions <7%, and accuracies within 12% of spiked concentrations. Limits of quantification were 0.25 μg/L in urine and 0.01 ng/mg hair for both TBA and DET. Matrix effect evaluation showed that the isotope dilution approach allowed for the control of bias sources. TBA and DET were determined in specimens of agriculture workers exposed to TBA using the validated method. Hair samples contained TBA levels in the low nanogram per milligram range, and urine samples contained DET levels in the low microgram per liter range. Conversely, TBA levels in urine samples and DET levels in hair samples were always below the limit of quantification.  相似文献   

14.
付慧  胡小键  陈曦  林少彬 《色谱》2018,36(5):487-492
建立了高效、准确的同时测定人体尿样中多种多环芳烃代谢物的方法。取10.0 mL尿液,酶解,经固相萃取净化浓缩、0.2 μm滤膜过滤后,以Acquity UPLC®HSS T3(100 mm×2.1 mm,1.8 μm)为分析柱,甲醇和水为流动相,采用负离子电喷雾多反应监测模式检测样品中多环芳烃代谢物的含量。12种多环芳烃代谢物在0.04~20.0 μg/L范围内线性关系良好,相关系数>0.99,方法检出限为0.01~0.41 μg/L,平均回收率为80.0%~105%,批内RSD为1.21%~9.12%,批间RSD为4.43%~19.7%。应用该方法对淮河流域某区域的100份人体尿样进行了检测,多环芳烃代谢物的检出率为98%。该方法操作简单,灵敏度高,选择性好,可同时检测尿中12种羟基多环芳烃代谢物。  相似文献   

15.
Triple quadrupole mass spectrometers, when operated in multiple reaction monitoring (MRM) mode, offer a unique combination of sensitivity, specificity, and dynamic range. Consequently, the triple quadrupole is the workhorse for high-throughput quantitation within the pharmaceutical industry. However, in the past, the unit mass resolution of quadrupole instruments has been a limitation when interference from matrix or metabolites cannot be eliminated. With recent advances in instrument design, triple quadrupole instruments now afford mass resolution of less than 0.1 Dalton (Da) full width at half maximum (FWHM). This paper describes the evaluation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput bioanalysis with emphasis on comparison of selectivity, sensitivity, dynamic range, precision, accuracy, and stability under both unit mass (1 Da FWHM) and enhanced (相似文献   

16.
A reliable and rapid method has been developed for the determination of 10 mycotoxins (beauvericin, enniatin A, A1, B1, citrinin, aflatoxin B1, B2, G1, G2 and ochratoxin A) in eggs at trace levels. Ultra-high-pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) has been used for the analysis of these compounds in less than 7 min. Mycotoxins have been extracted from egg samples using a QuEChERS-based extraction procedure (Quick, Easy, Cheap, Effective, Rugged and Safe) without applying any further clean-up step. Extraction, chromatographic and detection conditions were optimised in order to increase sample throughput and sensitivity. Matrix-matched calibration was used for quantification. Blank samples were fortified at 10, 25, 50 and 100 μg kg(-1), and recoveries ranged from 70% to 110%, except for ochratoxin A and aflatoxin G1 at 10 μg kg(-1), and aflatoxin G2 at 50 μg kg(-1). Relative standard deviations were lower than 25% in all the cases. Limits of detection ranged from 0.5 μg kg(-1) (for aflatoxins B1, B2 and G1) to 5 μg kg(-1) (for enniatin A, citrinin and ochratoxin A) and limits of quantification ranged from 1 μg kg(-1) (for aflatoxins B1, B2 and G1) to 10 μg kg(-1) (for enniatin A, citrinin and ochratoxin A). Seven samples were analyzed and aflatoxins B1, B2, G1, G2, and beauvericin were detected at trace levels.  相似文献   

17.
Glutathione S-transferases (GSTs) isolated from maize were used to catalyze the conjugation of glutathione (GSH) with chloroacetanilide herbicides, producing stable conjugates that were structurally characterized using ultra-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/QqToF-MS) and liquid chromatography/ion trap mass spectrometry (LC/IT-MS). Enzyme-mediated dechlorination of alachlor, metolachlor, and propachlor resulted during GSH conjugation as revealed by the mass spectra of the conjugates, which was confirmed by the loss of the chlorine isotopic signature and from high accurate mass measurements. Several fragmentation patterns in the mass spectra of the chloroacetanilide-GSH conjugates can be used to verify the identities of the enzyme reaction products, such as characteristic ions corresponding to the neutral loss of glutamic acid residue (129 Da) and water (18 Da) observed in the product ion spectrum. For the first time, data are presented showing detection of chloroacetanilides that are conjugated with two GSH molecules, in addition to the known single GSH conjugates.  相似文献   

18.
The separation of intact proteins is inherently more complex than that of small molecules using reversed‐phase liquid chromatography. The goal of this work was to determine a reasonable set of operational parameters (a recommended starting point for other analysts) for the separation of intact proteins and their detection by triple quadrupole mass spectrometry. Although protein separations have been studied for many years, the direct detection of intact proteins with mass spectrometry requires special considerations of mobile phase additives to achieve efficient separation and sensitive detection. Myoglobin, cytochrome c, lactalbumin, lysozyme, and ubiquitin were used as model analytes to investigate chromatographic method development using a triple quadrupole mass spectrometer and detection by multiple reaction monitoring. Chromatographic parameters including the concentration of trifluoroacetic acid, flow rate, gradient slope, temperature, mobile phase composition, and stationary phase chemistry were evaluated. Protein charge state profiles were also monitored for temperature and modifier effects. An optimized method using 0.2 mL/min flow rate, 15% gradient slope, and 75°C with a combined trifluoroacetic acid and formic acid modified mobile phase was developed.  相似文献   

19.
20.
A liquid chromatography/tandem mass spectrometric method for absolute quantification of cardiac troponin T (cTnT) in mouse heart tissue is presented. Even in such a complex biological sample, the multiple reaction monitoring acquisition mode allowed the selective and sensitive determination of a specific peptide, obtained by cTnT enzymatic digestion. The concentration of this cTnT-specific peptide was considered as a representation of the concentration of its parent protein. Quantification was carried out by means of the matrix-matched calibration curve, constructed by adding the synthetic standard of the target peptide and another synthetic structurally analogous peptide as internal standard. Method identification limit and method quantification limit were estimated as 60 and 110 ng of cTnT per mg of total extracted proteins, respectively. The developed label-free approach has been applied for the absolute quantitation of cTnT because of its diagnostic and prognostic value as cardiac disease marker. However, the method could be of general application, since it requires only the synthesis of two suitable peptides, a protein tryptic cleavage product and an internal standard.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号