首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Fat‐soluble vitamins play a pivotal role in the progression of atherosclerosis and the development of cardiovascular disease. Therefore, plasma monitoring of their concentrations may be useful in the diagnosis of these disorders as well as in the process of treatment. The study aimed to develop and validate an HPLC–MS/MS method for determination of retinol, α‐tocopherol, 25‐hydroxyvitamin D2 and 25‐hydroxyvitamin D3 in plasma of patients with cardiovascular disease. The analytes were separated on an HPLC Kinetex F5 column via gradient elution with water and methanol, both containing 0.1% (v/v) formic acid. Detection of the analytes was performed on a triple‐quadrupole MS with multiple reaction monitoring via electrospray ionization. The analytes were isolated from plasma samples with liquid–liquid extraction using hexane. Linearity of the analyte calibration curves was confirmed in the ranges 0.02–2 μg/mL for retinol, 0.5–20 μg/mL for α‐tocopherol, 5–100 ng/mL for 25‐hydroxyvitamin D2 and 2–100 ng/mL for 25‐hydroxyvitamin D3. Intra‐ and inter‐assay precision and accuracy of the method were satisfactory. Short‐ and long‐term stabilities of the analytes were determined. The HPLC‐MS/MS method was applied for the determination of the above fat‐soluble vitamin concentrations in patient plasma as potential markers of the cardiovascular disease progression.  相似文献   

2.
A simple and sensitive GC-EI-MS method using solvent extraction and evaporation was developed for the determination of olanzapine concentrations in plasma samples. Because olanzapine and promazine, which was used as the internal standard (IS), are nitrogenous bases, they can adsorb to the weakly acidic silanol groups on the surfaces of glass centrifuge tubes during solvent extraction and evaporation. Silylation of the glass tubes, addition of triethylamine (TEA), and use of a sample solution with a basic pH could prevent adsorption loss. The extraction method involved mixing plasma (500 μL) in a silylated glass tube with a promazine solution (2 μg/mL, 25 μL) in methanol containing 1% TEA. After addition of aqueous sodium carbonate (0.5 mol/L, pH 11.1, 1 mL) and extraction into 3 mL of dichloromethane/n-hexane (1:1, v/v) containing 1% TEA, the organic phase was evaporated to dryness in a silylated glass tube. The residue was dissolved in ethyl acetate containing 1% TEA (50 μL). For GC-EI-MS analysis, the calibration curves of olanzapine in human plasma were linear from 0.5 to 100 ng/mL. Intra- and interday precisions in plasma were both less than 7.36% (coefficient of variation), and the accuracy was between 94.6 and 110% for solutions with concentrations greater than 0.5 ng/mL. The limit of quantification was 0.5 ng/mL in plasma. The assay was applied to therapeutic drug monitoring in samples from three schizophrenic patients.  相似文献   

3.
Vitamin D is an important determinant of bone health at all ages. The plasma concentrations of 25-hydroxy vitamin D (25-OH D) and other metabolites are used as biomarkers for vitamin sufficiency and function. To allow for the simultaneous determination of five vitamin D metabolites, 25-OH D3, 25-OH D2, 24,25-(OH)2 D3, 1,25-(OH)2 D3, and 1,25-(OH)2 D2, in low volumes of human plasma, an assay using ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) was established. Plasma samples were spiked with isotope-labeled internal standards and pretreated using protein precipitation, solid-phase extraction (SPE) and a Diels–Alder derivatization step with 4-phenyl-1,2,4-triazoline-3,5-dione. The SPE recovery rates ranged from 55% to 85%, depending on the vitamin D metabolite; the total sample run time was <5 min. Mass spectrometry was conducted using positive ion electrospray ionization in the multiple reaction monitoring mode on a quadrupole–quadrupole-linear ion trap instrument after pre-column addition of methylamine to increase the ionization efficiency. The intra- and inter-day relative standard deviations were 1.6–4.1% and 3.7–6.8%, respectively. The limit of quantitation for these compounds was determined to be between 10 and 20 pg/mL. The 25-OH D results were compared with values obtained for reference materials (DEQAS). In addition, plasma samples were analyzed with two additional Diasorin antibody assays. All comparisons with conventional methods showed excellent correlations (r 2 = 0.9738) for DEQAS samples, demonstrating the high degree of comparability of the new UHPLC-MS/MS technique to existing methods.  相似文献   

4.
Interest in the metabolism and physiological action of vitamin D is increased exponentially. The most important metabolites of vitamin D are 25‐hydroxyvitamin and 1,25‐dihydroxyvitamin D3. The aim of the study was to develop a rapid and simple HPLC method for the measurement of 25‐hydroxyvitamin D3 in human plasma. A method for the measurement of 25‐hydroxyvitamin D3 using HPLC with UV detection and investigation into the extraction techniques with regard to stability and recovery are described. For the separation, RP column LiChroCart 125‐4, Purospher RP‐18e, 5 μm, was used. The mixture of methanol and deionized water (95:5 v/v) was used as mobile phase. The analytical performance of this method is satisfactory: the intra‐ and inter‐assay coefficients of variation were below 10%. Quantitative recoveries from spiked plasma samples were between 92.0–103.2%. The LOD was 10 nmol/L. The preliminary reference range of 25‐hydroxyvitamin D3 in a group of blood donors is 62 ± 26 nmol/L.  相似文献   

5.
A sensitive and selective liquid chromatography with tandem mass spectrometry (LC‐MS/MS) was developed for determining the concentrations of novel Janus kinase inhibitor ASP015K and its sulfated metabolite M2 in rat plasma. This method involves solid‐phase extraction (SPE) from 25 μL of rat plasma. LC separation was performed on an Inertsil PH‐3 column (100 mm L ×4.6 mm I.D., 5 µm) with a mobile phase consisting of 10 mM ammonium acetate and methanol under linear gradient conditions. Analytes were introduced to the LC‐MS/MS through an electrospray ionization source and detected in positive‐ion mode using selected reaction monitoring. Standard curves were linear from 0.25 to 500 ng/mL (r ≥0.9964). This assay enabled quantification of ASP015K and M2 at a concentration as low as 0.25 ng/mL in rat plasma. Validation data demonstrated that the method is selective, sensitive and accurate. Further, we also successfully applied this method to a preclinical pharmacokinetic study in rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
A selective, sensitive and fully automated column-switching LC system using direct injection of human plasma followed by mass spectrometry (MS) detection was developed and validated to determine the concentrations of 4-demethoxy-3'-deamino-3'-aziridinyl-4'-methylsulphonyldaunorubicin++ + (PNU-159548) and its 13-hydroxy metabolite (PNU-169884). A 50-microl human plasma sample was directly introduced into a C4-alkyl-diol silica clean-up column separating analytes from proteins and polar endogenous compounds using water and methanol as the mobile phase. The fraction containing PNU-159548 and its metabolite was back-flushed and transferred to the analytical column. The compounds were separated using a Zorbax SB C8 column (150x4.6 mm, 5 microm) under gradient conditions with the mobile phase containing acetonitrile and 2 mM ammonium formate, pH 3.5. MS detection was by atmospheric pressure ionisation with multiple reaction monitoring in positive ion mode. Linearity was demonstrated over the calibration range of 0.051-10.291 ng/ml for PNU-159548 and 0.104-10.434 ng/ml for PNU-169884. The assay was validated with respect to accuracy, precision and analyte stability. On the basis of the validation data, the developed analytical method was found to be suitable for use in Phase I clinical studies.  相似文献   

7.
李鹏飞  王燕  张征  童卫杭  吴华  马萍  王静  刘丽宏 《分析化学》2012,40(10):1573-1578
建立高效液相色谱-质谱联用法同时测定人血浆中免疫抑制剂及合并用药12种药物浓度的方法.选用Kromasil-C18色谱柱(50 mm× 4.6 mm×5 μm),以甲醇-乙腈-1mmol/L乙酸铵溶液为流动相,采用梯度洗脱进行分离,样本用甲醇沉淀蛋白后进样,流速:1.1 mL/min;柱温:35℃;进样量:20μL.选用3200QTrap型液相色谱-串联质谱仪的多反应监测(MRM)扫描方式进行检测.12种药物的线性范围为0.2~1000μg/L;定量下限为0.2 μg/L.准确度与精密度结果显示方法日间、日内RSD均小于15%;相对偏差-13%~9.33%,稳定性较好.本方法快速、灵敏,专属性强、重现性好,可用于人体血浆中免疫抑制剂及其常用合并用药共12种药物浓度的测定.  相似文献   

8.
A new method is described for the analysis of vitamin D and its metabolites utilizing thermospray (TSP) mass spectrometry as an on-line detector for high performance liquid chromatography. Ionization conditions were optimized for use with isocratic reversed phase chromatography. TSP mass spectrometry was employed in series with a UV absorbance detector to facilitate comparisons between the two methods of detection. Positive ion TSP mass spectra were recorded for vitamin D2, vitamin D3, 25-hydroxyvitamin D3 (25(OH)D3), 1,25-dihydroxyvitamin D3 (1,25(OH)2D3) and 24,25-dihydroxyvitamin D3 (24,25(OH)2D3). The spectra contained protonated molecular ions, ammonium adduct ions and fragment ions due to the loss of one or more molecules of water. A comparison of quantitative precision was made by determining UV absorbance and TSP standard curves for vitamin D3 using two different methods: (1) External standard method with post-column (post UV detector) addition of ammonium acetate. (2) As (1) but using the method of internal standards with a closely eluting internal standard (vitamin D2). In each case the quantitative precision (correlation coefficient) for UV absorbance detection was superior owing to intrinsic instability of the TSP ion beam. A stable isotopically labelled internal standard was employed in the development of an assay for 1,25(OH)2D3. The assay was used to quantify in vitro enzymic conversion of 25(OH)D3 to 1,25(OH)2D3 in guinea pig and sheep renal mitochondrial incubations. TSP LC/MS was also applied to analysis of an extract of human blood plasma in which D3 and each of its principal metabolites were identified in a single analysis.  相似文献   

9.
A simple, short, and rugged LC–MS/MS method for the simultaneous determination of tenofovir, emtricitabine, elvitegravir and rilpivirine was developed and validated. Dried blood spots were prepared with 25 μL of spiked whole blood. A 3 mm punch was extracted with methanol containing labeled internal standards. Ten microliters was injected into the LC–MS/MS using isocratic mobile phase composed of 0.1% formic acid in water and 0.1% formic acid in acetonitrile (45: 55 v/v) at a flow rate of 0.25 mL/min. The method was validated in the range of 10–2000 ng/mL for all four analytes. The intra‐assay accuracy (RE) of the method was −4.73–4.78, 1.35–2.89, −8.89 to −0.49 and − 1.40–1.81 for tenofovir, emtricitabine, elvitegravir and rilpivirine, respectively. The inter‐assay accuracy was within ±15% of nominal and precision (CV) was <15%. The hematocrit effect on quantification was nonsignificant at the tested hematocrit levels (35–70%). The dried blood spot method showed good agreement with the plasma method, and hence can be used as an alternative to plasma method.  相似文献   

10.
Dipyridamole is a classic platelet inhibitor which has been a key medicine in clinical therapy of thrombosis and cerebrovascular disease. A rapid, selective and convenient method using high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS) was developed for determination of dipyridamole in human plasma. After protein precipitation of 200 μL plasma with methanol, dipyridamole and diazepam (internal standard) were chromatographed on an Ultimate? XB‐C18 (50 × 2.1 mm i.d, 3 μ) column with the mobile phase consisting of methanol–ammonium acetate (5 mM ; 80 : 20, v/v) at a flow rate of 0.25 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via positive eletrospray ionization source (ESI+). The retention times of dipyridamole and diazepam were 1.4 and 1.2 min, respectively. The method was validated over a concentration range of 0.0180–4.50 μg/mL (r2 ≥ 0.99) with a lower limit of quantitation (LLOQ) of 0.0180 μg/mL for dipyridamole. The intra‐ and inter‐day precisions (RSD) of the assay at all three QC levels were 1.6–12.7% with an accuracy (RE) of ?4.3–1.9%, which meets the requirements of the FDA guidance. The HPLC‐MS/MS method herein described was proved to be suitable for pharmacokinetic study of sustained‐release dipyridamole tablet in volunteers after oral administration. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
A liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay was developed and validated to determine valproic acid in human plasma. The method involved a solid-phase extraction of valproic acid and betamethasone valerate, an internal standard, from plasma and detection using an LC-MS/MS system with electrospray ionization source in negative ion mode. Separation was achieved within 3 min on a non-porous silica column with mobile phase containing ammonium acetate and methanol. Multiple reaction monitoring was utilized for detection monitoring at 142.89-142.89 for valproic acid and 457.21-457.21 for the internal standard. The calibration curve for valproic acid was linear over the range of 0.5-150 microg/mL. The limit of detection was 0.17 microg/mL and the lower limit of quantification was 0.5 microg/mL, when 0.2 mL plasma was used for extraction. The percentage coefficient of validation for accuracy and precision (inter- and intra-day) for this method was less than 9.5% with recovery ranging from 82.3 to 86.9% for valproic acid.  相似文献   

12.
Vitamin D deficiency in an infant is associated with a wide range of adverse health outcomes in later life. A method for the quantification of 25‐hydroxyvitamin D3 [25(OH)D3, the best‐established indicator of vitamin D status] in neonatal dried blood spots (DBSs) using LC/ESI‐MS/MS has been developed and validated. The method employed two steps of derivatization, a Diels–Alder reaction with 4‐phenyl‐1,2,4‐triazoline‐3,5‐dione followed by acetylation, to enhance the detectability of 25(OH)D3 in ESI‐MS/MS and to separate 25(OH)D3 from 3‐epi‐25‐hydroxyvitamin D3 [3‐epi‐25(OH)D3], a potent interfering metabolite. 25(OH)D3 was extracted from two DBS punches (3 mm in diameter, equivalent to 5.3 μL of whole blood), purified using an Oasis HLB® cartridge, and subjected to derivatization prior to analysis with LC/ESI‐MS/MS. 25‐Hydroxyvitamin D4 was used as the internal standard. This method was reproducible (intra‐ and inter‐assay RSDs, <6.9%) and accurate (analytical recovery, 95.2–102.7%), and the LOQ was 3.0 ng/mL. The developed method enabled specific quantification of 25(OH)D3 in neonatal DBSs and detection of vitamin D deficiency without interference from 3‐epi‐25(OH)D3.  相似文献   

13.
林强  杨超  李美丽  王佳  侯瀚然  邵兵  牛宇敏 《色谱》2023,41(3):274-280
人体生物基质中麻痹性贝类毒素的检测对其引起的食物中毒诊断和救治具有重要意义。研究建立了超高效液相色谱-串联质谱法测定血浆、尿液中14种麻痹性贝类毒素的分析方法。实验比较了不同固相萃取柱的影响,优化了前处理条件和色谱条件,血浆样品采用0.2 mL水、0.4 mL甲醇、0.6 mL乙腈提取后直接上机测定,尿液样品采用0.2 mL水、0.4 mL甲醇、0.6 mL乙腈提取,聚酰胺(PA)固相萃取柱净化后上机测定。采用Poroshell 120 HILIC-Z色谱柱(100 mm×2.1 mm,2.7μm)对14种贝类毒素进行分离,流动相为含0.1%(v/v)甲酸的5 mmoL/L甲酸铵缓冲溶液和0.1%(v/v)甲酸乙腈溶液,流速为0.50 mL/min。在电喷雾模式(ESI)下进行正负离子扫描,采用多反应监测(MRM)模式检测,外标法定量。结果表明,对于血浆和尿液样品,14种贝类毒素分别在0.24~84.06 ng/mL范围内线性关系良好,相关系数均大于0.995。尿液检测的定量限为4.80~34.40 ng/mL,血浆检测的定量限为1.68~12.04 ng/mL。尿液和血浆样品在1、2和10倍定量限加标水平下平均回收率为70.4%~123.4%,日内精密度为2.3%~19.1%,日间精密度为4.0%~16.2%。应用建立的方法对腹腔注射14种贝类毒素小鼠血浆和尿液进行测定,20份血浆样本中检出含量分别为19.40~55.60μg/L和8.75~13.86μg/L。该方法操作简便,样品取样量少,方法灵敏度高,适用于血浆和尿液中麻痹性贝类毒素的快速检测。  相似文献   

14.
Zhang Y  Ma X  Lü P  Li H  Lu X 《色谱》2012,30(1):95-98
建立了小型家用电器塑料部件中双酚A的液相色谱-串联质谱(LC-MS/MS)检测方法。采用快速溶剂萃取仪对样品进行萃取,以Sep-Pak C18固相萃取柱净化,甲醇-水(含有0.05%氨水)混合液作为流动相,负离子模式下进行MS/MS检测。结果表明: 该方法在5~100 μg/L范围内线性关系良好,相关系数(r2)为0.9991。在10、25和75 μg/kg 3个添加水平下,双酚A的平均回收率为95.2%~109.7%,相对标准偏差均小于3.8%,检出限为10 μg/kg。该方法操作简便,灵敏度高,适用于家用电器塑料部件中双酚A的残留分析。  相似文献   

15.
A practical, sensitive, and robust UPLC–MS/MS method was developed and validated to quantify lacosamide in human plasma. A simple one-step protein precipitation was used to extract lacosamide and labeled lacosamide-13C, D3 as an internal standard (IS) from 150-μL plasma. The extracts were analyzed on an Eclipse Plus C18 column (50 × 2.1 mm, 1.8 μm) using 0.1% formic acid in water and methanol:acetonitrile (50:50, v/v) under gradient conditions. The extracts were quantified on LCMS-8040 using electrospray ionization source operated in positive ionization and multiple reaction monitoring modes. The method showed good linearity from 0.02 to 20 μg/mL, which was adequate to cover lacosamide concentration assayed in formulations with different strengths. The bioanalytical assay was fully validated as per current regulatory guidelines. The intra-batch and inter-batch precision values of lacosamide were less than 4.6%. Lacosamide was found to be stable at different storage conditions. The extraction recoveries and IS-normalized matrix factors for lacosamide ranged from 97.17 to 99.68% and from 0.973 to 1.012, respectively. The validated method was successfully applied to a pharmacokinetic study with three lacosamide formulations (50, 100, and 200 mg) in 36 healthy subjects. The assay reliability was determined by reanalysis of 81 subject samples.  相似文献   

16.
Among more than 50 provitamin carotenoids, beta-carotene is the most metabolically active source of retinol. Despite diets rich in fruits and vegetables containing beta-carotene, vitamin A deficiency is the leading cause of blindness and childhood mortality in developing countries. In addition, the uncertainty of beta-carotene bioconversion into vitamin A suggests that new data are needed to update the nutritional guidelines in developed countries. Previously, we reported the development of a carotene/retinol plateau isotopic enrichment method (CarRet PIE) for the determination of beta-carotene bioavailability and bioconversion into retinol, which utilizes positive ion atmospheric pressure chemical ionization (APCI) liquid chromatography/mass spectrometry (LC/MS). While seeking to validate the CarRet PIE using a mass balance approach requiring fecal measurements of beta-carotene and retinol, interference was encountered that required substantial modifications of the LC/MS assay. Here we report a new LC/MS assay that is based on the detection of molecular anions of beta-carotene using negative ion APCI with a reversed-phase C30 column for HPLC separation. Sample preparation required saponification to eliminate interfering triglycerides. The limit of detection (LOD) of beta-carotene was 0.25 pmol calculated on the basis of an injection of 20 microL of 0.0125 microM beta-carotene, and the limit of quantitation (LOQ) was 1.0 pmol based on the injection of 20 microL of 0.050 microM beta-carotene. The linear range was 1.1 to 2179 pmol on-column. The wide linear range and low LOD and LOQ of this assay facilitated the sensitive and selective quantitative analysis of beta-carotene in both serum and fecal samples in support of an on-going clinical investigation of beta-carotene bioavailability and bioconversion into vitamin A.  相似文献   

17.
A method of sample clarification and high-performance liquid chromatography specifically developed to permit precise and rapid determination of vitamin A (retinol) and vitamin E (alpha-tocopherol) in serum and plasma is reported. Serum proteins were denatured by the addition of acetonitrile containing alpha-tocopherol acetate, the internal standard; the vitamins were subsequently extracted into an organic matrix consisting of ethyl acetate-butanol (1:1); no solvent evaporation step was required. The three vitamins of interest were eluted from a reversed-phase C18 column with an isocratic mobile phase methanol-water (95:5); detection was accomplished by measuring ultraviolet absorption at 280 nm. Recoveries of retinol, alpha-tocopherol and alpha-tocopherol acetate from spiked aqueous samples averaged 100.0, 100.0 and 98.8%, respectively. Recoveries of retinol, alpha-tocopherol and alpha-tocopherol acetate from plasma and serum relative to water were 102.6, 96.9 and 96.5%, respectively. Retinol and alpha-tocopherol were stable in the extraction matrix for up to 3.5 h, and were stable in heparinized plasma stored at room temperature for two days. Oxalate, citrate and EDTA caused significant losses of retinol and alpha-tocopherol, while vitamin levels in serum and heparinized plasma were similar. Limits of detection for retinol and alpha-tocopherol were 60 ng/ml and 0.9 micrograms/ml, respectively. Each run required 12 min. Same-day coefficients of variation were 3.5 and 3.6% for retinol and alpha-tocopherol, respectively (n = 11). Between-day coefficients of variation for retinol and alpha-tocopherol were 4.8 and 5.5%, respectively (n = 5). This method permits simple, rapid, sensitive, selective and precise determination of retinol and alpha-tocopherol using 0.5 ml of serum or heparinized plasma.  相似文献   

18.
The aim of this study was to establish a high-throughput and sensitive LC–MS/MS method for the determination of doxepin and its major active metabolite nordoxepin in human plasma. It has been designed for bioequivalence study for formulations containing 25 mg of doxepin. Doxepin and nordoxepin were extracted from human plasma samples by protein precipitation with acetonitrile by using protein precipitation 96-well plates. The analyte was separated using a Phenomenex Kinetex Biphenyl column (100 × 2.1 mm, 2.6 μm) using isocratic elution with a mobile phase of 20 mM ammonium formate (30%) and acetonitrile:methanol 3:7 v:v (70%) at a flow rate of 0.5 mL/min and an injection volume of 10 μL. The detection was performed using a triple quadrupole mass spectrometer by multiple reaction monitoring mode to monitor the precursor-to-product ion transitions of m/z 280.4 → 107.0 and 283.4 → 235.0 for doxepin and doxepin-D3, respectively, and 266.3 → 106.9 and 269.3 → 235.0 for nordoxepin and nordoxepin-D3, respectively, in positive electrospray ionization mode. The total run time was 3.5 min. The method was validated over a concentration range of 50–10,000 pg/mL using a Triple Quad 4500 MS System (Sciex) for both analytes. The developed and validated method can be successfully used to study the bioequivalence/pharmacokinetics of doxepin and nordoxepin.  相似文献   

19.
搅拌棒吸附子萃取与GC-MS法测定水中20种有机氯农药   总被引:2,自引:0,他引:2  
建立了搅拌棒吸附子萃取/气相色谱-质谱法(SBSE/GC-MS)同时检测水中α-六六六、γ-六六六、β-六六六、七氯、δ-六六六、艾氏剂、环氧七氯、γ-氯丹、顺-氯丹、硫丹Ⅰ、p,p-滴滴伊、狄氏剂、异狄氏剂、p,p-滴滴滴、硫丹Ⅱ、p,p-滴滴涕、异狄氏剂醛、硫丹硫酸盐、甲氧滴滴涕、异狄氏剂酮20种有机氯农药含量的方法.样品在室温下经拌棒吸附子搅拌吸附,甲醇解吸附后,以J&W DB-35 MS(30 m×0.25 mm×0.25 μm)石英毛细管色谱柱为分析柱,气相色谱-质谱选择离子流模式检测.考察了萃取时间、氯化钠及甲醇加入量等对萃取的影响.实验结果表明:在2.5 ~20.0 μg/L 范围内,20种有机氯农药呈良好的线性关系,检出限(S/N=3)为0.008 ~0.118 μg/L,水样中分别添加2.5、20 μg/L的20种有机氯农药,回收率为 52% ~117%,相对标准偏差小于13%(n= 6).该方法操作简便、快速、灵敏度高,应用于实际样品检测,结果满意.  相似文献   

20.
The objective of this study was to develop a fast and robust method for the quantitation of the antifungal drug anidulafungin in human plasma samples by generic two-dimensional liquid chromatography (online-SPE/reversed phase LC) coupled to a tandem-quadrupole mass spectrometer (LC-online SPE-MS/MS). Online SPE was performed using an Oasis HLB cartridge column and for reversed-phase chromatography a Nucleodur Gravity C(18) column was used. A 100 μL aliquot of human plasma was extracted with 200 μL of 80:20 MeOH-0.2 M ZnSO(4) (v/v) as precipitation reagent containing ascomycin as internal standard (IS). The supernatant was directly injected for analysis. The total run time was 4.5 min. Anidulafungin and ascomycin were detected in the positive ionization mode. The method performance data for anidulafungin, such as limit of detection (0.013 μg/mL), lower limit of quantitation (0.04 μg/mL), linearity (R(2) = 0.9999) and concentration range (0.04-10 μg/mL) were ascertained. Intra- and inter-day precisions were ≤6.6% and intra- and inter-day accuracies were 98.5-101.0 and 100.0-102.5%, respectively. The assay was successfully applied for quantitation of anidulafungin in patient plasma samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏