首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A modified atmospheric pressure chemical ionization ion source is applied for direct analysis of volatile or low volatile organic compounds in air. The method is based on the direct introduction of the analytes in the gas phase and/or particle phase into the ion source of a commercial ion-trap mass spectrometer. Two methods are employed for the production of primary ions at atmospheric pressure, photoionization and corona discharge. It is shown that in the presence of a dopant, photoionization can be a highly efficient ionization method also for real-time analysis with detection limits for selected analytes in the lower ppt-range. Using corona discharge for the production of primary ions, which is instrumentally easier since no additional chemicals have to be added to the sample flow, we demonstrate the analytical potential of on-line atmospheric pressure chemical ionization mass spectrometry for reaction monitoring experiments. To do so, an atmospherically relevant gas phase reaction is carried out in a 500 l reaction chamber and gaseous and particulate compounds are monitored in the positive and negative ion mode of the mass spectrometer.  相似文献   

2.
3.
Super‐atmospheric pressure chemical ionization (APCI) mass spectrometry was performed using a commercial mass spectrometer by pressurizing the ion source with compressed air up to 7 atm. Similar to typical APCI source, reactant ions in the experiment were generated with corona discharge using a needle electrode. Although a higher needle potential was necessary to initiate the corona discharge, discharge current and detected ion signal were stable at all tested pressures. A Roots booster pump with variable pumping speed was installed between the evacuation port of the mass spectrometer and the original rough pumps to maintain a same pressure in the first pumping stage of the mass spectrometer regardless of ion source pressure. Measurement of gaseous methamphetamine and research department explosive showed an increase in ion intensity with the ion source pressure until an optimum pressure at around 4–5 atm. Beyond 5 atm, the ion intensity decreased with further increase of pressure, likely due to greater ion losses inside the ion transport capillary. For benzene, it was found that besides molecular ion and protonated species, ion due to [M + 2H]+ which was not so common in APCI, was also observed with high ion abundance under super‐atmospheric pressure condition. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
The use of high-performance liquid chromatography combined with chloride-enhanced atmospheric pressure chemical ionization for the determination of polychlorinated n-alkanes (PCAs, also called chlorinated paraffins or CPs) is described as an alternative to gas chromatographic methods. Atmospheric pressure chemical ionization in the negative ion mode formed exclusively [M+Cl](-) adduct ions and suppressed fragmentation when a chlorinated solvent was added. Limits of detection were 1-2 ng/microL for technical PCA mixtures. Response factors for single short-chain PCA homologues with different degrees of chlorination varied by not more than a factor of 6.5. The developed method was applied for the determination of the composition of technical PCA mixtures as well as for the analysis of PCAs in household commodities. Medium-chain PCAs were found in paint samples at concentrations of 8.2-11.5% (w/w), compared with 7.4-11.5% obtained by gas chromatography combined with electron ionization tandem mass spectrometry.  相似文献   

5.
6.
7.
8.
9.
Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) for fluorinated phenols (C6H5-xFxOH Where x = 0-5) in nitrogen with Cl- as the reagent ion yielded product ions of M Cl- through ion associations or (M-H)- through proton abstractions. Proton abstraction was controllable by potentials on the orifice and first lens, suggesting that some proton abstraction occurs through collision induced dissociation (CID) in the interface region. This was proven using CID of adduct ions (M Cl-) with Q2 studies where adduct ions were dissociated to Cl- or proton abstracted to (M-H)-. The extent of proton abstraction depended upon ion energy and structure in order of calculated acidities: pentafluorophenol > tetrafluorophenol > trifluorophenol > difluorophenol. Little or no proton abstraction occurred for fluorophenol, phenol, or benzyl alcohol analogs. Ion mobility spectrometry was used to determine if proton abstraction reactions passed through an adduct intermediate with thermalized ions and mobility spectra for all chemicals were obtained from 25 to 200 degrees C. Proton abstraction from M Cl- was not observed at any temperature for phenol, monofluorophenol, or difluorophenol. Mobility spectra for trifluorophenol revealed the kinetic transformations to (M-H)- either from M Cl- or from M2 Cl- directly. Proton abstraction was the predominant reaction for tetra- and penta-fluorophenols. Consequently, the evidence suggests that proton abstraction occurs from an adduct ion where the reaction barrier is reduced with increasing acidity of the O-H bond in C6H5-xFxOH.  相似文献   

10.
Use of optimized instrument parameters that result from statistical experimentation revealed that the sensitivity of atmospheric pressure chemical ionization (APCI) liquid chromatography-mass spectrometry (LC/MS) is greater than the sensitivity of an optimized Thermabeam? LC/MS interface by about 3 orders of magnitude, when tested on aromatic compounds. APCI is one of the few LC/MS techniques in which the chromatogram is directly comparable with liquid chromatographs that use ultraviolet detection. The optimum instrument parameters for a Finnigan SSQ-7000 APCI LC/MS interface were found at low flow rates (e. g., 0. 1 mL/min), relatively low capillary heat (e. g., 225 °C), and high sheath-gas pressure (e. g., 60 lb/in2). The optimization was achieved by monitoring the responses of sensitivity, fragmentation, and cluster ion formation. The fine tuning for high sensitivity calls for a high percentage of water in the mobile phase. In contrast, a high percentage of organic content in the mobile phase is required to obtain abundant protonated molecular ions with respect to fragmentation and clustering. This is an important consideration for analyses of unknowns.  相似文献   

11.
There is an increasing need to be able to conduct quantitative lipidomics analyses as a complement to proteomics studies. The highest specificity for proteomics analysis can be obtained using methodology based on electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS). For lipidomics analysis it is often necessary to be able to separate enantiomers and regioisomers. This can be very challenging when using methodology based on conventional reversed-phase chromatography. Normal-phase chromatography using chiral columns can provide dramatic improvements in the resolution of enantiomers and regioisomers. However, conventional ESI- and APCI-MS/MS has limited sensitivity, which makes it difficult to conduct studies in cell culture systems where only trace amounts of non-esterified bioactive lipids are present. The use of electron capture APCI-MS/MS overcomes this problem. Enantiomers and regioisomers of diverse bioactive lipids can be quantified using stable isotope dilution methodology coupled with normal-phase chiral chromatography and electron capture APCI-MS/MS. This methodology has allowed a lipidomics profile from rat epithelial cells maintained in culture to be delineated and allowed the effect of a non-selective lipoxygenase inhibitor to be assessed.  相似文献   

12.
A new continuous chromatographic process (VARICOL) has been presented recently. The basic principle of the new VARICOL process consists of an asynchronous shift of the inlet/outlet lines in a multi-column system on a recycle loop. This process has been used to perform the separation of the optical isomers of the SB-553261 racemate. In this paper, we illustrate that for this specific separation, the VARICOL process is more efficient than the well-known SMB process.  相似文献   

13.
The behavior in atmospheric pressure chemical ionization of selected model polycyclic aromatic compounds, pyrene, dibenzothiophene, carbazole, and fluorenone, was studied in the solvents acetonitrile, methanol, and toluene. Relative ionization efficiency and sensitivity were highest in toluene and lowest in methanol, a mixture of molecular ions and protonated molecules was observed in most instances, and interferences between analytes were detected at higher concentrations. Such interferences were assumed to be caused by a competition among analyte molecules for a limited number of reagent ions in the plasma. The presence of both molecular ions and protonated analyte molecules can be attributed to charge-transfer from solvent radical cations and proton transfer from protonated solvent molecules, respectively. The order of ionization efficiency could be explained by incorporating the effect of solvation in the ionization reactions. Thermodynamic data, both experimental and calculated theoretically, are presented to support the proposed ionization mechanisms. The analytical implications of the results are that using acetonitrile (compared with methanol) as solvent will provide better sensitivity with fewer interferences (at low concentrations), except for analytes having high gas-phase basicities.  相似文献   

14.
We present the results of studying the effects of temperature and humidity of the reaction medium and the intensity of ultraviolet radiation on the atmospheric pressure chemical ionization of Penthrite. The peculiarities of the ion mobility spectra of this compound obtained by ion mobility spectrometry-tandem mass spectrometry are analyzed.  相似文献   

15.
Fast atom bombardment (FAB) mass spectrometry provides useful structural information about salen complexes and salen-based oxo transfer catalysts that are not appreciably soluble in organic solvents. It was discovered that initial dissolution of these complexes in trifluoroacetic acid was crucial for producing good FAB mass spectra. Trifluoroacetic acid helps dissolve the salen-based catalysts, concentrates the analyte molecules at the matrix surface, and most importantly, suppresses the reduction process, which is a well-known phenomenon when protic matrices are used. The best FAB matrices for these catalysts were found to be thioglycerol and “magic bullet.” However, dechlorination occurred under the acid conditions for complexes containing iron chloride and manganese chloride. Demetalation also occurred for nickel-containing oxo transfer salen-based complexes. When the salen-based complexes are soluble in LC solvents, they can be analyzed easily by atmospheric pressure chemical ionization (APCI) mass spectrometry without the employment of relatively nonvolatile matrices. In addition, APCI/MS provides much more sensitive detection for manganese-salen complexes when compared with FAB results. No dechlorination or demetalation were observed when a negative ion mode APCI was employed. To our knowledge, this is the first time that an intact molecule of this type of complex has been observed by mass spectrometry.  相似文献   

16.
A method using liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI-MS) has been developed for the characterization and determination of pyridoquinoline derivatives 4,6-bis(dimethylaminoethylamino)-2,8,10-trimethylpyrido[3,2-g]quinoline, 4,6-bis(dimethylaminoethoxy)-2,8,10-trimethylpyrido[3,2-g]quinoline and 4,6-bis[(dimethylaminoethyl)thio]-2,8,10-trimethylpyrido[3,2-g] quinoline, all with potential antitumor properties. LC separation was performed on a conventional C18 column using a binary mobile phase composed of acetonitrile and 50 mM aqueous ammonium formate at pH 3. The APCI mass spectra obtained showed that proton addition giving [M + H]+ was the common mode of ionization to the amino- and thiopyridoquinolines, whereas the alkoxypyridoquinoline was identified by the main formation of the [M - (C2H3)N(CH3)2 + H]+, followed by the [M + H]+ ion. The LC separation conditions and MS detection parameters were optimized for the determination. The analytical method was also applied to the determination of these pyridoquinoline derivatives in fetal calf serum using liquid-liquid extraction with dichloromethane. Acceptable recovery values were obtained, ranging between 45 and 98%.  相似文献   

17.
Atmospheric pressure chemical ionization mass spectrometry (APCI-MS) has been used to characterize the air-sensitive paramagnetic organouranium azide and nitride complexes [(C5Me5)2UN3(mu-N3)]3 and [(C5Me5)U(mu-I)2]3N, respectively. The trimetallic complex [(C5Me5)U(mu-I)2]3E had been identified by X-ray crystallography, but the data did not definitively identify E as N3- versus O2- or (OH)-, a common problem in heavy-element nitride complexes involving metals with variable oxidation states. A comparison of the 250 degrees C APCI-MS spectra of products made from NaN3 and Na15NNN showed mixed [M]+ and [M + H]+ envelopes at expected ion intensities for the 14N and 15N isotopomers. A compilation of U-C(C5Me5) and U-I bond distance data for U3+ and U4+ is also reported that shows that the ranges for the two oxidation states have significant overlap.  相似文献   

18.
High-performance liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (HPLC/APCI-MS) is a very promising approach to structural investigations of positional isomers and stereoisomers. This method was applied successfully to stereoisomeric norditerpenoid alkaloids differing in configuration at C-6. APCI-MS allowed the easy and precise control of energy deposition by varying the drift voltage. Comparison of the breakdown curves, observed by changing the potential difference between the first electrode and the second electrode of the APCI ion source, revealed the stereochemical dependence of different fragmentations. Comparison of the APCI spectra showed that the abundance of fragment ions was significantly higher for C-6beta alkaloid than for C-6alpha alkaloid. The axial positions of the corresponding substituents (6-methoxyl and 8-hydroxyl) strongly suggested a 1,3-diaxial interaction effect of the fragmentation. The characteristic fragment ions were formed by the loss of water or acetic acid at position 8, irrespective of the stereochemistry at position 6. The possibility of distinct fragmentation mechanisms depending on the stereochemistry of the precursor ion could be discerned by recording the spectra in a deuterated solvent system of 0.05 M ammonium acetate in D2O-acetonitrile-tetrahydrofuran. Loss of D2O from the precursor ion gave the fragment ion. This result indicated that the proton of protonation was included in the leaving water molecule. The peak intensity ratio R = [M+H]+/[M+H-H2O]+ manifested the stereochemical differentiation of alkaloids at position 6.  相似文献   

19.
20.
The fragmentation behavior of taxoids was studied using electrospray (ESI) and atmospheric pressure chemical ionization (APCI) sources with multi-stage tandem mass spectrometry. In the positive ion mode taxoids gave prominent [M+Na]+ and [M+K]+ ions with the ESI source, and [M+NH4]+ or [M+H]+ ions with the APCI source. The MS/MS fragmentations of ions produced by APCI and ESI sources were very similar. For both sources, the presence of cinnamoyl or benzoyl groups could be characterized by initial losses of 148 or 122 u, respectively, from molecular adduct ions. However, the elimination of cinnamic acid was relatively difficult for the molecular adduct ions formed by APCI, and was comparable in importance to the loss of acetic acid. The other fragments involved losses of CH2CO, CO, and H2O. The 5/7/6 type taxoids underwent characteristic losses of 58 or 118 u from ions produced by both APCI and ESI sources. The fragmentation behavior was remarkably influenced by substitution locations. The elimination of the C-10 benzoyl group was usually the first fragmentation step, while that of the C-2 benzoyl group was relatively difficult. The acetoxyl group at C-7 was more active than those at C-2, C-9, and C-10, which in turn were more active than that at C-4. These fragmentation rules could facilitate the rapid screening and structural characterization of taxoids in plant extracts by high-performance liquid chromatography/mass spectrometry (HPLC/MS).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号