首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Recent applications of scanning electrochemical microscopy (SECM) to studies of single biological cells are reviewed. This scanning probe microscopic technique allows the imaging of an individual cell on the basis of not only its surface topography but also such cellular activities as photosynthesis, respiration, electron transfer, single vesicular exocytosis and membrane transport. The operational principles of SECM are also introduced in the context of these biological applications. Recent progress in techniques for high-resolution SECM imaging are also reviewed. Future directions, such as single-channel detection by SECM, high-resolution imaging with nanometer-sized probes, and combined SECM techniques for multidimensional imaging are also discussed.  相似文献   

2.
The electrocatalytic activity of platinum for hydrogen oxidation in 0.01 M H2SO4 + 0.1 MNa2SO4 solution has been investigated by scanning electrochemical microscopy (SECM) technique. The cyclic voltammogram (CV), approach curve, area scan imaging and chronoamperometric methods have been used. The results indicate that the imaging capability of the SECM feedback mode can be used more efficiently to visually identify materials' electrocatalytic activity, compared with the approach curve method for identification of the conductive or insulating nature of a surface. The SECM imaging method has demonstrated the effects of Pt substrate potential on the electrocatalytic oxidation of hydrogen under a constant tip potential. It is found that the more positive the Pt substrate potential, the lower the electrocatalytic activity of the Pt. Furthermore, the chronoamperometric results support the variation of the electrocatalytic activity with the Pt substrate potential as well.  相似文献   

3.
《Analytical letters》2012,45(18):2876-2886
Micron-size ion selective micropipettes can be used in scanning electrochemical microscopy (SECM). They can provide excellent spatial resolution. Unfortunately the resistance of these small sensors is high. Their application needs special shielding and slow scanning rates. Usually their lifetime hardly exceeds a few days.

Zinc layer or dispersed zinc particles containing films are often used for providing cathodic protection against corrosion in case of metal surfaces. Therefore, in corrosion studies, measurements of local zinc ion concentration can give important information about the nature of the process. For corrosion studies we needed SECM measuring tips for imaging concentration profiles of Zn2+ions involved in surface processes. Based on our earlier experience, solid contact micropipettes for selective measurements of Zn2+ion concentration were prepared with a tip size of a few micrometers. The properties of the micropipettes were investigated. They were also used in SECM imaging. In this paper, details of Zn2+ion selective microelectrode preparation are described. Data about their properties, lifetime, resistance, and ion activity response are shown. Preliminary findings in SECM imaging of zinc ion concentration profiles are shown. The improvement of the scanning rate achieved by lowering tip resistance is a main advantage in potentiometric SECM.  相似文献   

4.
The redox competition mode of scanning electrochemical microscopy (SECM) was used to visualize differences in local electrocatalytic activity of Fe and Ni hexacyanoferrates (HCFs) in hydrogen peroxide reduction. The uniform round-shaped spots of electrocatalysts for the SECM measurements were electrochemically deposited using a scanning droplet cell. A negligible activity of NiHCF towards H2O2 reduction compared to Prussian Blue (PB) was observed. The dependence of local Prussian Blue activity on the applied potential was investigated. The proposed strategy explores the potential application of SECM as a rapid screening tool for HCF film activity within a single experiment.  相似文献   

5.
The applicability of ion-selective microelectrodes (ISME) in scanning electrochemical microscopy (SECM) in the presence of potentially interfering ions is investigated. Decreasing the time needed for potentiometric SECM imaging is a key aim. It is generally accepted that the long response time of potentiometric cells with high impedance microelectrodes limits the imaging speed that can be obtained without distortion. In this study we show that a change in the activity of interfering ions can result in a short-term electrode potential transient that should be taken into consideration in parameter setting for SECM measurements. The activity step method was employed, using NH4+-ion-measuring micropipettes. Solutions containing equal concentrations of NH4+ ions with or without K+ ions were rapidly introduced and the short-term change in electrode potential was recorded. Rapid transient potential signals appeared following the K+ activity step in the range where the interfering K+ did not affect the long-term electrode potential. The possible influence of this on SECM applications is discussed.  相似文献   

6.
Scanning electrochemical microscopy (SECM) has been approved as a prospective electrochemical micromachining (ECMM) technique soon after its birth. However, it still remains challenge for SECM to fabricate arbitrary three-dimensional (3D) microstructures because of the limitation of positioning system. To solve this problem, we proposed a tip current signal/positioning close-loop mode in which the tip current signal is fed back to the positioning system in order to program the motion trial of SECM tip. Both the triedge-cone and sinusoidal microstructures were obtained by the close-loop positioning mode. The static-state etching process was demonstrated not to be disturbed by the slow motion rate of SECM tip. The unique positioning mode would be significant for both ECMM and electrochemical imaging.  相似文献   

7.
Scanning electrochemical microscopy (SECM) still lacks reliable means for performing constant-distance imaging experiments. We demonstrate, for the first time, that the same negative alternating current (AC) feedback can be observed on approach to an insulator and an unbiased conductor at optimal experimental conditions. This leads to a novel constant-distance imaging mode. To perform AC-SECM imaging, only minor modifications of the existing SECM set-up were necessary. The new constant-distance AC-SECM imaging was conducted to provide topographical information not affected by variations in sample conductivity and reactivity. Furthermore, simultaneous AC and DC SECM measurements were carried out to demonstrate that both topographical and chemical information could be revealed.  相似文献   

8.
Scanning electrochemical microscopy (SECM) is discussed as a versatile tool to provide a unique approach of localized electrochemical information in the context of biosensing research. The step-by-step immobilization of DNA aptamer with intrinsic redox activity on screen-printed carbon electrode (SPCE) was successfully monitored using SECM imaging tool. Control experiments were performed with a non-electroactive aptamer. After immobilization of these aptamers, SECM images showed the repartition of the electroactive anti-tetracycline aptamer when comparing with images produced for control and for all modification steps of SPCE. The possibility of tetracycline detection was also proved by causing a decrease in recorded current.  相似文献   

9.
Scanning electrochemical microscopy (SECM) is a powerful technique for performing quantitative measurements at a local scale. This paper covers the development of combinations of SECM with electrochemical impedance spectroscopy (EIS) and electrochemical quartz crystal microbalance (EQCM). Basic aspects are described and potential applications reported by several research groups are covered. The unique advantages of the coupled techniques—with additional information being obtained from each coupling—are also discussed.  相似文献   

10.
The local visualisation of corrosion pits has so far failed to convincingly prove the advantage of scanning microscopy in overcoming Abbey’s Limit. Thus, for imaging pit initiation and instant pit growth the resolution of the methods used for detecting the related changes in local electrochemical activity has to be significantly improved. Progress into this direction has been achieved by combining shear force based constant-distance mode scanning electrochemical microscopy (SECM) with the alternating current mode of this technique (AC-SECM). A very small corrosion pit was generated by inducing active corrosion underneath an accurately positioned 5 μm diameter Pt disk SECM tip that served as counter electrode in the direct mode of SECM. Before and after pit initiation, constant-distance mode AC-SECM images were recorded and subsequently used to identify the area of broken passivity. The results demonstrate the feasibility of the suggested approach to image actively corroding sites with overall dimensions of only a few micrometers. Combination of constant-distance scanning with AC-SECM is an important prerequisite for further improving spatial resolution by employing smaller-diameter micro- or even nano-electrodes as SECM tips.  相似文献   

11.
A short review is given on scanning electrochemical microscopy (SECM). The historic background of the technique is briefly summarized and the basic principles outlined. The three different directions of its use: chemical microscopic imaging, the measuring of physicochemical constants and coefficients, and use as a micromachining tool are briefly discussed. The general built-up of the SECM apparatus is described. Preparation and use of several different measuring tips are introduced. A few examples are given of the application of SECM measurement in different studies.  相似文献   

12.
A short review is given on scanning electrochemical microscopy (SECM). The historic background of the technique is briefly summarized and the basic principles outlined. The three different directions of its use: chemical microscopic imaging, the measuring of physicochemical constants and coefficients, and use as a micromachining tool are briefly discussed. The general built-up of the SECM apparatus is described. Preparation and use of several different measuring tips are introduced. A few examples are given of the application of SECM measurement in different studies.  相似文献   

13.
《Electroanalysis》2005,17(22):2001-2017
New strategies for the construction of DNA chips and the detection of DNA hybridization will be discussed in this review. The focus will be on the use of polypyrrole as a linker between a substrate and oligonucleotide probes. The modification step is based on the electrochemical copolymerization of pyrrole and oligonucleotides bearing a pyrrole group on its 5′ end. This strategy was employed for the immobilization of oligonucleotides on millimeter‐sized electrodes, microelectrode arrays, as well as for the local structuring of homogeneous gold surfaces. Our approaches for the localized patterning of gold surfaces will be also discussed. Localized immobilization was achieved by using an electrospotting technique, where a micropipette served as an electrochemical cell where spot sizes with 800 μm diameters were fabricated. The use of a microcell using a Teflon covered metal needle with a cavity of 100 μm resulted in immobilized probe spots of 300 μm. Scanning electrochemical microscopy (SECM) was also used, and surface modifications of 100 μm were obtained depending on the experimental conditions. Different detection methods were employed for the reading of the hybridization event: fluorescence imaging, surface plasmon resonance imaging (SPRI), photocurrent measurements, and voltamperometric measurements using intercalators. Their advantages concerning the various immobilization strategies will also be discussed.  相似文献   

14.
A Prussian Blue (PB) film modified disk ultramicroelectrode (UME) was fabricated by electrochemical deposition technique on a Pt-disk UME. The electrocatalytical reductions of hydrogen peroxide derived from glucose oxidase (GOD) on this modified UME were investigated. The enzymatic biochemical reactivity was imaged by scanning electrochemical microscopy (SECM) utilizing the PB film modified UME. It is evident that sensitivity and spatial resolution for hydrogen peroxide measurement were improved obviously. SECM images obtained clearly revealed the concentration profile of the reaction products around the enzymes. The PB film modified microelectrode is in the nature of simple preparation, high catalytic activity on hydrogen peroxide and substrate selectivity for SECM etc.  相似文献   

15.
 An investigation of an array of four Pt microband electrodes 25 μm wide and spaced 25 μm apart was performed with the scanning electrochemical microscope (SECM). Where possible the SECM measurements were confirmed with conventional electrochemical measurements. It is shown how the sensiti- vity of the SECM recycling current to the activity of the underlying surface can be used to probe the homogeneity of enzyme-modified microelectrodes. The diffusion of H2O2 between these micro enzyme- electrodes and unmodified electrodes was investigated and it was demonstrated how the SECM can be a powerful tool in the elucidation of the properties of these electrodes. Received June 8, 1998. Revision November 12, 1998.  相似文献   

16.
The scanning electrochemical microscope (SECM) is used to image the activity of enzymes immobilized on the surfaces of disk-shaped carbon-fiber electrodes. SECM was used to map the concentration of enzymatically produced hydroquinone or hydrogen peroxide at the surface of a 33-microm diameter disk-shaped carbon-fiber electrode modified by an immobilized glucose-oxidase layer. Sub-monolayer coverage of the enzyme at the electrode surface could be detected with micrometer resolution. The SECM was also employed as a surface modification tool to produce microscopic regions of enzyme activity by using a variety of methods. One method is a gold-masking process in which microscopic gold patterns act as mask for producing patterns of chemical modification. The gold masks allow operation in both a positive or negative process for patterning enzyme activity. A second method uses the direct mode of the SECM to produce covalently attached amine groups on the carbon surface. The amine groups are anchors for attachment of glucose oxidase by use of a biotin/avidin process. The effect of non-uniform enzyme activity was investigated by using the SECM tip to temporarily damage an immobilized enzyme surface. SECM imaging can observe the spatial extent and time-course of the enzyme recovery process.  相似文献   

17.
This review summarizes the characterization of localized enzymatic activity by scanning electrochemical microscopy (SECM). After introducing the concepts of feedback imaging and generator-collector experiments with enzyme-modified solid surfaces, a comparison of the merits and limitations of both approaches is given and further illustrated by selected applications. They include enzyme-modified patterned monolayers, enzyme-modified polymer microstructures and enzyme-modified metal microstructures. Such configurations are important for the development of miniaturized bioanalytical systems with proteins, such as miniaturized enzyme electrode arrays. SECM has emerged as an ideal tool for prototyping of such systems. It also offers several mechanisms for local surface modifications under conditions compatible with conservation of protein functionality of enzymes and antibodies. The subsequent imaging of the immobilized activity provides direct information about local immobilized enzyme activity. The range of biotechnological applications can be expanded by labeling other biomolecules, such as monoclonal antibodies, with appropriate enzymes. Miniaturized electrochemical enzyme immunoassays that apply the sandwich format and SECM as the detection method are reviewed. They have been performed on microstructured supports after reagent spotting or on agglomerates of surface-modified magnetic microbeads. Finally, current challenges are listed with indications of ongoing research to overcome current limitations by means of instrumental improvements.  相似文献   

18.
Serebrennikova I  Lee S  White HS 《Faraday discussions》2002,(121):199-210; discussion 229-51
Spatial!y localized electrochemical activity at Al/Al2O3 electrodes has been investigated using scanning electrochemical microscopy (SECM) in order to establish the relationship between localized corrosion of Al (and Al alloys) with the defect structure of the native Al2O3 film. Local electron transfer at microscopic defects (2 to 50 microm radius) was visualized in acetonitrile solutions using the nitrobenzene/nitrobenzene radical anion (Eo approximately -1.6 V vs. Ag/Ag+) and tetracyanoquinodimethane/tetracyanoquinodimethane radical anion couples (Eo approximately -0.3 V) as redox mediators for imaging. SECM investigations revealed no significant differences in electrochemical activity at Al/AI203 electrodes in the two mediator solutions, indicating that electrical conduction at the defect sites is weakly dependent on interfacial potential and the electric field across the Al2O3 film. The density of electroactive defects observed by SECM varied by 2 to 3 orders of magnitude between electrodes prepared from the same source of Al (either 99.450% and 99.9995%) suggesting that electrical conduction in the native oxide is very sensitive to surface preparation. Defect densities as low as approximately 3 sites cm(-2) were readily measured by SECM.  相似文献   

19.
Preparation and characterization of microscopic biochemically active regions are important for the development of miniaturized bioanalytical systems with proteins, such as miniaturized enzyme electrode arrays. Scanning electrochemical microscopy (SECM) has emerged as an ideal tool for prototyping such systems. The technique is based on electrochemical conversions of dissolved species at a micrometer-sized probe electrode. It offers several mechanisms for local surface modifications under conditions compatible with conservation of protein functionality of enzymes and antibodies. The subsequent imaging of the immobilized activity provides direct information about local immobilized enzyme activities. The working modes of the techniques are illustrated by recent studies from this laboratory for the design and characterization of patterned enzyme layers covalently linked to gold surfaces via thiol self-assembly chemistry.  相似文献   

20.
Lanlan Zhu  Wenrui Jin 《Talanta》2008,77(2):804-808
Scanning electrochemical microscopy (SECM) is a powerful tool to examine the respiratory activity of living cells. However, in SECM measurements of cell respiratory activity, the signal recorded usually also includes the signal corresponding to the cell topography. Therefore, measurements of cell respiratory activity using conventional SECM techniques are not accurate. In the present work, we develop a method for accurate measurement of the respiratory activity of single living cells using SECM. First, cells are immobilized on a glass substrate modified with collagen. Then, a Pt ultramicroelectrode tip of SECM held at −0.50 V is scanned along the central line across a living cell and a SECM scan curve, i.e., the relationship of the tip current versus the displacement (the first scan curve) is recorded with a negative peak. The peak current ip on this first scan curve is composed of ip1, which corresponds to the cell respiratory activity and ip2, which corresponds to the cell topography. In order to isolate the ip2 component, the cell is killed by exposing it to 1.0 × 10−3 mol/L KCN for 10 min. The tip is then scanned again with the same trace over the dead cell, and a second SECM scan curve is recorded. Noting that the topography of the dead cell is the same as that of the living cell, this second scan curve with a negative peak corresponds now only to the cell topography. Thus, ip2 is obtained from the second SECM scan curve. Finally, ip1 corresponding to the respiratory activity of the living cell can be accurately calculated using ip1 = ip − ip2. This method can be used to monitor real-time change in the respiratory activity of single cells after exposing them to KBr, NaN3 and KCN.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号