首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The retention of alkylphosphonic acids (MPA, EPA, PPA, and BPA) and inorganic anions (Cl, NO3, and SO42−) were studied on two anion exchangers, e.g., Dionex IonPac AS4A-SC (250 ± 4 mm I.D.) and Satisfaction P 4000-SAX (50 ± 4.6 mm I.D.) under isocratic elution conditions with evaporative light scattering detector. The plots of retention factors, k, of organic anions vs. the reciprocal of eluent ion concentration show good linearity. The major retention mechanisms are interpreted as ion exchange and some others interactions. The C effect of organic modifier added to the aqueous buffered mobile phase is also investigated.  相似文献   

2.
单一阴离子交换柱同时分离有机酸和无机阴阳离子   总被引:8,自引:0,他引:8  
丁明玉  陈培榕 《分析化学》1997,25(2):161-164
研究了用乙二胺四乙酸(EDTA)作淋洗液时,性质迥异的有机酸、无机阴离子和碱土金属离子(Ca^2+、Mg^2+)在同一阴离子交换柱上的同时分离以及保留机理,结果表明,在离子交换机理之外,非离子交换机理对有机酸及钙镁的EDTA络阴郭的保留行为起一定的辅助作用,9种有机酸和无机阴阳离子在10min内得到了较好的分离。各离子的电导检测灵敏度在10^-9至10^-11mol,能满足环境和食吕分析的要求。  相似文献   

3.
Methyl-capped poly(ethylene oxide) moieties were chemically bonded to silica gel using an amine-reactive modification reagent and evaluated as the stationary phase for ion chromatography. In this work, primary amino groups of an aminopropylsilica packing material were reacted with methyl-PEO12-NHS ester (succinimidyl-{[N-methyl]-dodecaethyleneglycol} ester) in phosphate buffer (pH 7.0) at room temperature. The prepared poly(ethylene oxide)-bonded stationary was evaluated for the separation of inorganic anions, and the retention behavior of inorganic anions on the prepared stationary phase was examined. The elution order of the investigated anions was the same as that observed in common ion chromatography. Both cations and anions of the eluent affected the retention of the analyte anions. Ion exchange was involved for the retention of analyte anions, although the present stationary phase does not possess any discrete ion-exchange sites. The stationary phase was applied to the separation of trace anions contained in tap water and a rock salt.  相似文献   

4.
《Analytical letters》2012,45(12):2701-2710
Abstract

Suppressed ion-chromatography using Na2CO3/NaHCO3 as eluent was applied to the determination of chloride, sulphate, nitrate and bromide in highly mineralised waters. The effect of different concentrations of hydrogen carbonate on the retention times of the determination of the four selected anions was studied. Depending on the total concentration of ionic species, dilution of the sample is recommended to obtain retention times approaching those of the anion standard. The stability of sample composition was not affected by the presence of iron(III) ions (up to 15 mgL?1).  相似文献   

5.
A multifunctional electrodialytic generator (EDG) for capillary ion chromatography (CIC) is described. The same device can generate acidic, basic or saline eluents. Two oppositely charged ion exchange beads are used to fabricate the EDG; the dual ion exchanger configuration ensures the production of gas-free eluent, obviating the need of a gas removal device used with single ion exchanger EDG's. The ability of the same EDG to produce different eluents is governed solely by the choice of the respective feed solutions; this is presently demonstrated by generation of diverse eluents such as Na2CO3/NaHCO3, CH3SO3H, and KNO3. The EDG is implemented simply in a commercial cross fitting and has been tested up pressures to 2000 psi. Under typical operating conditions, the zero current concentration (open circuit penetration, OCP) is negligible. The generated eluent concentration linearly increases with applied current with a slope that is essentially Faradaic. The device permits both isocratic and gradient operation with good reproducibility, as demonstrated by the analysis of anions using HCO3/CO32− EDG.  相似文献   

6.
有机酸在阴离子交换树脂上的保留行为及其机理   总被引:12,自引:2,他引:12  
丁明玉  陈培榕 《色谱》1998,16(2):111-114
研究了有机酸在阴离子交换树脂上的保留行为。首次报道了有机酸在阴离子交换色谱过程中的“多峰现象”,即一种有机酸有两个或两个以上的色谱峰流出色谱柱。对这种“多峰现象”形成的机理进行了初步探讨,提出了有机酸离解后的不同价数阴离子在阴离子交换树脂上同时保留的机理。研究中还发现离解很弱的有机酸的保留行为不完全符合离子交换机理。  相似文献   

7.
傅厚暾 《色谱》2001,19(6):513-515
 研究了离子色谱弱酸阴离子分析中以氢氧化钠作淋洗液时 ,弱酸阴离子的调整保留时间随淋洗液中氢氧化钠浓度变化的规律 ,建立了二者关系的非线性函数模型。将一元非线性问题转化为多元线性问题求解 ,磷酸根的调整保留值与淋洗液中氢氧化钠浓度关系回归方程的相关系数在 0 99以上。用该数学模型预测磷酸根阴离子的保留值 ,相对误差小于 5 % 。  相似文献   

8.
A vitamin U-bonded stationary phase was prepared and the retention behavior of inorganic anions was examined using ion chromatography. Inorganic anions were retained on the vitamin U-bonded stationary phase under acidic as well as neutral eluent conditions in the ion-exchange mode. The elution order of the examined anions under neutral eluent conditions was nearly the same as that observed in common ion exchange mode, while the elution order observed under acidic eluent conditions was completely different from that observed in common ion exchange mode. The retention of the analyte anions under the neutral eluent conditions was due to the sulfonium groups of the vitamin U, while protonated primary amino groups caused retention of the analyte anions with different selectivity under acidic conditions. The retention factor of the analyte anions increased with decreasing eluent concentration under both eluent conditions. The present system was applied to the determination of bromide and nitrate contained in seawater.  相似文献   

9.
This work focuses on problems regarding empirical retention modelling and optimization of separation in ion chromatography. Influences of eluent flow rate and concentration of eluent competing ion (OH) on separation of seven inorganic anions (fluoride, chloride, nitrite, sulphate, bromide, nitrate, and phosphate) were investigated. Artificial neural networks and multiple linear regression retention models in combination with several criteria functions were used and compared in global optimization process. It can be seen that general recommendations for optimization of separation in ion chromatography is application of chromatography exponential function criterion in combination with artificial neural networks retention model.  相似文献   

10.
离子交换色谱中混合保留机理的研究   总被引:1,自引:0,他引:1  
张嘉捷  王雪  陈梅兰  朱岩 《化学学报》2008,66(8):964-968
鉴于离子交换色谱中被测离子和有机聚合物树脂之间存在的吸附作用, 选择阴离子交换色谱柱IonPacAS9-HC为研究对象, 针对离子交换色谱中的吸附保留行为, 从色谱混合保留机理的角度出发, 考虑各色谱柱固定相含量和界面吸附面积的不同, 建立柱间保留的相互关系方程. 在五根不同批号IonPacAS9-HC (250 mm×2 mm I.D.)柱上, 以含50%乙腈(V/V)的9 mmol/L Na2CO3为流动相, 0.25 mL/min流速, 对12个不同结构类型的无机和有机阴离子(氟离子、氯离子、硫酸根、磷酸根、二羟基丁酸、丙酮酸、乙酸、丙烯酸、苯甲酸、丙二酸、酒石酸和邻苯二甲酸)的保留行为进行研究, 并采用推导所得的混合保留机理模型对溶质这一保留特征进行表征, 结果较为理想, 其中一价离子的相关系数为0.9~0.999, 二价离子的相关系数为0.999~1, 为离子交换色谱中吸附保留行为的研究提供了新方法.  相似文献   

11.
自Small等首次采用双柱阴离子色谱法测定无机阴离子以来,单柱阴离子色谱法已被用于测定无机阴离子、有机酸,并利用金属阳离子与EDTA形成的阴离子配合物分离测定阳离子。但用单柱阴离子色谱法同时测定无机阴离子、无机阳离子和有机酸尚未见报道。本文采用EDTA为淋洗液的单柱阴离子色谱法研究了无机阴离子、无机阳离子和有机酸的同时分析测定。  相似文献   

12.
A new stationary phase Al2O3/SiO2-10 was prepared and characterized by XPS, XRD, SEM and surface analysis. The anion exchanger properties of this new stationary phase were investigated by the separation of inorganic anions in ion chromatography (IC). pH of the mobile phase, concentration and strength of the Lewis base of the elute, and the organic modifier of the mobile phase strongly affect the separation of inorganic anions, and anion exchange selectivities of the analyte on the new support are significantly different from quaternary ammonium styrene based anion exchangers. The result of separation of inorganic anions shows that the new stationary phase provides excellent column efficiency, well-defined chromatographic peaks and favorable retention times.  相似文献   

13.
The mixed-mode separation of a selection of anionic and cationic pharmaceutically related compounds is studied using ion-exchange columns and eluents consisting of ionic salts (potassium hydroxide or methanesulfonic acid) and an organic modifier (methanol). All separations were performed using commercially available ion-exchange columns and an ion chromatography instrument modified to allow introduction of methanol into the eluent without introducing compatibility problems with the eluent generation system. Isocratic retention prediction was undertaken over the two-dimensional space defined by the concentration of the competing ion and the percentage of organic modifier in the eluent. Various empirical models describing the observed relationships between analyte retention and both the competing ion concentration and the percentage of methanol were evaluated, with the resultant model being capable of describing the separation, including peak width, over the entire experimental space based on six initial experiments. Average errors in retention time and peak width were less than 6% and 27%, respectively, for runs taken from both inside and outside of the experimental space. Separations performed under methanol gradient conditions (while holding the competing ion concentration constant) were also modelled. The observed effect on retention of varying the methanol composition differed between analytes with several analytes exhibiting increased retention with increased percentage methanol in the eluent. An empirical model was derived based on integration of the observed tR vs. %methanol plot for each analyte. A combination of the isocratic and gradient models allowed for the prediction of retention time using multi-step methanol gradient profiles with average errors in predicted retention times being less than 4% over 30 different 2- and 3-step gradient profiles for anions and less than 6% over 14 different 2- and 3-step gradient profiles for cations. A modified peak compression model was used to estimate peak widths under these conditions. This provided adequate width prediction with the average error between observed and predicted peak widths being less than 15% for 40 1-, 2- and 3-step gradients for anions and less than 13% over 14 1-, 2- and 3-step gradients for cations.  相似文献   

14.
杨瑞琴  蒋生祥 《分析化学》1998,26(9):1121-1124
采用氯甲基苯乙烯包夹硅胶基质制备出一种新型强阴离子色谱柱填料,该填料具有良好的色谱柱性能,可以较地的分离常见的6种无机阴离子,6种低碳链有机酸以及甲酸,乙酸和一些无机阴离子的混合物。  相似文献   

15.
离子色谱法同时分析董酒中的有机酸与无机阴离子   总被引:9,自引:4,他引:5  
丁明玉  陈培榕  罗国安 《色谱》1998,16(1):59-61
研究了用离子色谱法同时分析董酒中可离解性有机酸和无机阴离子。首次采用邻苯二甲酸氢钾和邻苯二甲酸的混合水溶液作淋洗剂,改善了分离效果,提高了检测灵敏度。所建立的方法无需进行样品前处理,无干扰,有一定的实用价值。  相似文献   

16.
Inorganic anions could be separated on porous graphitic carbon stationary phases in ion chromatography. Ion exchange between eluent anions and sample anions on the stationary phase was confirmed by the retention behavior and the possibility of indirect photometric detection. The elution order of anions was different from that observed for commercially available anion exchangers. Chloride, nitrate, and sulfate contained in tap water could be determined in 7 min.  相似文献   

17.
李宗英  陈新  章飞芳  杨丙成 《色谱》2022,40(8):730-735
制备了一种季铵化烯丙基缩水甘油醚(allyl glycidyl ether,AGE)改性聚合物基质的阴离子固定相应用于离子色谱系统。它是利用AGE与水解的聚甲基丙烯酸缩水甘油酯-二乙烯基苯poly(glycidylmethacrylate-divinylbenzene,GMA-DVB)微球表面残留双键通过表面自由基共聚,再通过N,N-二甲基乙醇胺(一种叔胺)进行开环反应制备得到的。通过考察有机叔胺类型、微球水解、单体和引发剂用量、反应温度和时间对7种阴离子分离性能的影响,优化了制备条件。采用扫描电镜、元素分析对所得阴离子固定相进行了表征。结果表明,采用预先水解的GMA-DVB微球(水解过程中微球表面丰富的环氧基团转化为羟基)相对于直接采用GMA-DVB微球有助于降低固定相的交换容量和微球自身的非离子吸附作用;通过淋洗液浓度和目标离子保留因子的拟合结果证实了该固定相保留机理为典型的离子交换作用。使用碳酸根淋洗液,在优化的色谱条件下,该固定相可在13 min内实现常见7种无机阴离子的基线分离,并表现出较高的柱效(Cl-理论塔板数为49000块/m)。该色谱柱实用性通过分析自来水实际样品进行了验证。  相似文献   

18.
An anion‐exchange chromatography method combined solid phase extraction (SPE) was developed for the simultaneous analysis of glycolate acid (GL), monochloroacetic acid (MCA) and dichloroacetic acid (DCA) in synthetical betaine products. The analytes and unknown anionic impurities were well separated on a Metrosep A supp5 anion‐exchange column (150 mm×4 mm) with 2.0 mmol/L Na2CO3+2.0 mmol/L NaHCO3 solution as eluent. Suppressed conductivity detection was used. A strong cation exchange (SCX) solid phase extraction (SPE) cartridge was used to reduce the concentration of matrix betaine and a Cleanert IC‐Ag pretreatment cartridge was used to remove high Cl? concentration. The detection limits of GL, MCA and DCA were 0.09, 0.017 and 0.05 µg/L, respectively. The relative standard deviations (RSDs) of the retention times and peak areas were less than 0.09% and 0.49%, respectively. The recoveries of the three analytes were between 90.6% and 100.8%. The analytical results showed that GL and DCA were present in high concentration and no MCA was found when the proposed ion chromatography method was applied to three synthetical betaine samples. The proposed method is simple, sensitive and timesaving, and is also suitable for routine analysis in quality control of synthetical betaine products.  相似文献   

19.
本文所提出的单柱离子色谱分离阴离子混合物的技术,不用抑制柱,树脂也无需再生。用国产多孔乙基苯乙烯-二乙烯苯共聚物制备了不同交换度的低容量阴离子交换树脂。以苯甲酸盐为洗脱液,F~-、Cl~-、Br~-可以分离,F~-峰尖锐,Br~-峰较宽。以邻苯二甲酸氢盐为洗脱液,保留时间均减小,但F~-峰被进样峰所掩盖,Cl~-、Br~-、SO_4~-:可满意地得到分离,洗脱液的浓度和pH对阴离子分离的保留时间和峰高有较大的影响。邻苯二甲酸氢盐中不同的阳离子,由于它们的电导背景不同(Li~+Na~+>K~+>NH_4~+。  相似文献   

20.
Auler LM  Silva CR  Bottoli CB  Collins CH 《Talanta》2011,84(4):1174-1179
This work describes the characterization and potential applications of a silica-based anion-exchange phase prepared by a two-step modification process that incorporates a propylpyridinium group. The effects of pH and eluent concentration on anion separation were examined using 150 mm × 3.9 mm HPLC columns packed with the new phase. The mobile phase pH values ranged from 3.8 to 6.6 using phthalic acid/Tris solutions. The best separation was achieved using 2.5 mmol L−1 phthalate/2.4 mmol L−1 Tris solution at pH 4.2 as mobile phase with non-suppressed conductivity detection. The new stationary phase was used for the separation of some inorganic and organic anions showing good resolution. The stability of the silica-based anion exchange phase was also evaluated.Analytical curves, for concentrations ranging from 0.25 to 10 mg L−1 for the inorganic anions chloride, nitrite, bromide and nitrate, showed good linear correlations (r > 0.998). The method was tested with certified rainwater samples. The measured and certified values were in good agreement, indicating that the new phase holds significant promise for the analysis of these anions in environmental samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号