共查询到20条相似文献,搜索用时 93 毫秒
1.
Katherine A. Koenig Ken E. Sakaie Mark J. Lowe Jian Lin Lael Stone Robert A. Bermel Erik B. Beall Stephen M. Rao Bruce D. Trapp Micheal D. Phillips 《Magnetic resonance imaging》2013
Introduction
Diffusion tensor imaging (DTI) measures in patients with multiple sclerosis (MS), particularly those measures associated with a specific white matter pathway, have consistently shown correlations with function. This study sought to investigate correlations between DTI measures in the fornix and common cognitive deficits in MS patients, including episodic memory, working memory and attention.Materials and Methods
Patients with MS and group age- and sex-matched controls underwent high-resolution diffusion scanning (1-mm isotropic voxels) and cognitive testing. Manually drawn forniceal regions of interest were applied to individual maps of tensor-derived measures, and mean values of transverse diffusivity (TD), mean diffusivity (MD), longitudinal diffusivity (LD) and fractional anisotropy (FA) were calculated.Results
In 40 patients with MS [mean age±S.D.= 42.55±9.1 years; Expanded Disability Status Scale (EDSS)=2.0±1.2; Multiple Sclerosis Functional Composite (MSFC) score=0.38±0.46] and 20 healthy controls (mean age±S.D.= 41.35±9.7 years; EDSS=0.0±0; MSFC score=0.74±0.24), we found that FA, MD and TD values in the fornix were significantly different between groups (P< .03), and patient performance on the Brief Visuospatial Memory Test-Revised (BVMT-R) was correlated with DTI measures (P< .03).Discussion
These results are consistent with findings of axonal degeneration in MS and support the use of DTI as an indicator of disease progression. 相似文献2.
Masaaki Hori Mariko Yoshida Kazumasa Yokoyama Koji Kamagata Fumitaka Kumagai Issei Fukunaga Kouhei Kamiya Michimasa Suzuki Yoshitaka Masutani Nozomi Hamasaki Yuriko Suzuki Shinsuke Kyogoku Nobutaka Hattori Shigeki Aoki 《Magnetic resonance imaging》2014
Introduction
Diffusion tensor imaging (DTI) reveals white matter pathology in patients with multiple sclerosis (MS). A recent non-Gaussian diffusion imaging technique, q-space imaging (QSI), may provide several advantages over conventional MRI techniques in regard to in vivo evaluation of the disease process in patients with MS. The purpose of this study is to investigate the use of root mean square displacement (RMSD) derived from QSI data to characterize plaques, periplaque white matter (PWM), and normal-appearing white matter (NAWM) in patients with MS.Methods
We generated apparent diffusion coefficient (ADC) and fractional anisotropy (FA) maps by using conventional DTI data from 21 MS patients; we generated RMSD maps by using QSI data from these patients. We used the Steel–Dwass test to compare the diffusion metrics of regions of interest in plaques, PWM, and NAWM.Results
ADC differed (P < 0.05) between plaques and PWM and between plaques and NAWM. FA differed (P < 0.05) between plaques and NAWM. RMSD differed (P < 0.05) between plaques and PWM, plaques and NAWM, and PWM and NAWM.Conclusion
RMSD values from QSI may reflect microstructural changes and white-matter damage in patients with MS with higher sensitivity than do conventional ADC and FA values. 相似文献3.
Yang Shin Park Chang Hee Lee Ji Hoon Kim In Seong Kim Berthold Kiefer Tae Seok Seo Kyeong Ah Kim Cheol Min Park 《Magnetic resonance imaging》2014
Purpose
To assess the usefulness of intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI) for predicting lipiodol uptake in patients with hepatocellular carcinoma (HCC) after transcatheter arterial chemoembolization (TACE).Materials and methods
The institutional review board approved this study. 44 HCC patients underwent IVIM-DWI and Gd-EOB-DTPA-enhanced MRI prior to TACE. Using post-TACE CT as a reference standard, each HCC was classified into either lipiodol good uptake (LGU) or poor uptake (LPU) group. Apparent diffusion coefficient (ADC), true diffusion coefficient (D), perfusion coefficient (D*), and perfusion fraction (f) in HCC were calculated. Arterial enhancement ratio (AER) and IVIM parameters were compared between those two groups using the Mann-Whitney U test.Results
Of the 51 HCCs, 37 (72.5%) were LGU group and 14 (27.5%) were LPU group. AER of HCC was significantly higher in LGU than LPU (0.99 ± 0.54 and 0.67 ± 0.45; P = .034). ADC, D, and f values were not significantly different (P = .073, .059, and .196, respectively) between these two groups. D* was significantly elevated in LGU than LPU (48.10 ± 15.33 and 26.75 ± 9.55; P = .001).Conclusion
Both AER derived from contrast enhanced MRI and D* values derived from IVIM-DWI for HCC were significantly higher in LGU than in LPU. These parameters would be helpful for predicting the lipiodol uptake. 相似文献4.
Francescamaria Donati Piero Boraschi Roberto Gigoni Simonetta Salemi Fabio Falaschi Carlo Bartolozzi 《Magnetic resonance imaging》2013
Purpose
To present diffusion and perfusion magnetic resonance imaging (MRI) characteristics of focal nodular hyperplasia (FNH) of the liver.Materials and Methods
Thirty-five patients with 52 FNHs (21 were pathologically-confirmed) underwent MRI at 1.5-T device. MR diffusion [diffusion-weighted imaging (DWI)] was performed using a free-breathing single-shot, spin-echo, echo-planar sequence with b gradient factor value of 500 s/mm². MR perfusion [perfusion-weighted imaging (PWI)] consisted of a 3D free-breathing LAVA sequence repeated up to 5 minutes after injection of 7 mL Gd-BOPTA (MultiHance, Bracco, Italy) and 20 mL saline flush at a flow rate of 4 mL/s. Apparent diffusion coefficient (ADC) and time-signal intensity curve (TSIC) were obtained for both normal liver and each FNH by two reviewers in conference; maximum enhancement (ME) percentage, time to peak enhancement (TTP), and maximal slope (MS) were also calculated.Results
On DWI mean ADC value was 1.624×10− 3 mm2/s for normal liver and 1.629×10− 3 mm2/s for FNH. ADC value for each FNH and the normal liver was not statistically different (P= .936). On PWI, TSIC-Type 1 (quick and marked enhancement and quick decay followed by slowly decaying) was observed in all 52 FNHs, and TSIC-Type 2 (fast enhancement followed by slowly decaying plateau) in all normal livers. The mean ME, TTP and MS values were significantly different for FNH and normal liver (P= .005).Conclusion
FNHs of the liver showed typical diffusion and perfusion MRI characteristics in all cases. On the ADC map, we could get similar value between the FNHs and the background parenchyma. On the perfusion imaging, FNHs showed a different pattern distinguished from the background liver. 相似文献5.
Yang Shin Park Chang Hee Lee Baek Hui Kim Jongmee Lee Jae Woong Choi Kyeong Ah Kim Jeong Hwan Ahn Cheol Min Park 《Magnetic resonance imaging》2013
Purpose
The purpose of the study was to determine significant imaging features to differentiate between infiltrative hepatocellular carcinoma (HCC) and confluent fibrosis (CF) in liver cirrhosis using Gd-EOB-DTPA-enhanced 3-T magnetic resonance imaging.Material and methods
Nineteen infiltrative HCCs and eight CFs were included. We evaluated the difference in imaging findings and apparent diffusion coefficient (ADC) between the two entities. We compared T2-weighted image (WI) and hepatobiliary phase (HBP) in terms of the clarity of the lesion outer margin.Results
Seventeen infiltrative HCCs showed lobulated margin, while focal CFs showed either straight (n = 3) or irregular margins (n = 5) (P = .001). All infiltrative HCCs had intact or bulging contours, and all focal CFs showed capsular retraction (P = .001). Fourteen infiltrative HCCs and two focal CFs showed arterial enhancement (P = .035). The ADC of infiltrative HCCs was significantly lower than that of CFs (P = .001). Satellite nodules were noted in 10 infiltrative HCCs. In terms of outer margin clarity, infiltrative HCCs showed a more distinct margin on HBP than on T2-WI (P = .005), while these two sequences were not significantly different in focal CFs (P = 1.000).Conclusion
HBP improved the imaging characteristics of infiltrative HCC, allowing it to be distinguished from focal CF. Infiltrative HCC showed lower ADC values than focal CF. Lobular configuration, contour bulging, enhancement pattern, associated satellite nodules and portal vein thrombosis were still found to be highly suggestive MR findings for infiltrative HCC. 相似文献6.
Nan-Jie Gong Chun-Sing Wong Chun-Chung Chan Lam-Ming Leung Yiu-Ching Chu 《Magnetic resonance imaging》2013
Object
Diffusional kurtosis imaging (DKI), a natural extension of diffusion tensor imaging (DTI), can characterize non-Gaussian diffusion in the brain. We investigated the capability of DKI parameters for detecting microstructural changes in both gray matter (GM) and white matter (WM) in patients with mild cognitive impairment (MCI) and Alzheimer's disease (AD) and sought to determine whether these DKI parameters could serve as imaging biomarkers to indicate the severity of cognitive deficiency.Materials and Methods
DKI was performed on 18 AD patients and 12 MCI patients. Fractional anisotropy, kurtosis and diffusivity parameters in the temporal, parietal, frontal and occipital lobes were compared between the two groups using Mann–Whitney U test. The correlations between regional DKI parameters and mini-mental state examination (MMSE) score were tested using Pearson's correlation.Results
In ADs, significantly increased diffusivity and decreased kurtosis parameters were observed in both the GM and WM of the parietal and occipital lobes as compared to MCIs. Significantly decreased fractional anisotropy was also observed in the WM of these lobes in ADs. With the exception of fractional anisotropy and radial kurtosis, all the five other DKI parameters exhibited significant correlations with MMSE score in both GM and WM.Conclusion
Bearing additional information, the DKI model can provide sensitive imaging biomarkers for assessing the severity of cognitive deficiency in reference to MMSE score and potentially improve early detection and progression monitoring of AD based on characterizing microstructures in both the WM and especially the GM. 相似文献7.
Masaaki Hori Satoshi Tsutsumi Yukimasa Yasumoto Masanori Ito Michimasa Suzuki Fumine S. Tanaka Shinsuke Kyogoku Masanobu Nakamura Takashi Tabuchi Issei Fukunaga Yuriko Suzuki Koji Kamagata Yoshitaka Masutani Shigeki Aoki 《Magnetic resonance imaging》2014
Introduction
We investigated microstructural changes in the spinal cord, separately for white matter and gray matter, in patients with cervical spondylosis by using diffusional kurtosis imaging (DKI).Methods
We studied 13 consecutive patients with cervical myelopathy (15 affected sides and 11 unaffected sides). After conventional magnetic resonance (MR) imaging, DKI data were acquired by using a 3 T MR imaging scanner. Values for fractional anisotropy (FA), apparent diffusion coefficient (ADC), and mean diffusional kurtosis (MK) were calculated and compared between unaffected and affected spinal cords, separately for white matter and gray matter.Results
Tract-specific analysis of white matter in the lateral funiculus showed no statistical differences between the affected and unaffected sides. In gray matter, only MK was significantly lower in the affected spinal cords than in unaffected spinal cords (0.60 ± 0.18 vs. 0.73 ± 0.13, P = 0.0005, Wilcoxon’s signed rank test).Conclusions
MK values in the spinal cord may reflect microstructural changes and gray matter damage and can potentially provide more information beyond that obtained with conventional diffusion metrics. 相似文献8.
Junichiro Sakamoto Akiko Imaizumi Yoshinori Sasaki Takashi Kamio Mamoru Wakoh Mika Otonari-Yamamoto Tsukasa Sano 《Magnetic resonance imaging》2014
Purpose
To evaluate the use of the intravoxel incoherent motion (IVIM) technique in half-Fourier single-shot turbo spin-echo (HASTE) diffusion-weighted imaging (DWI), and to compare its accuracy to that of apparent diffusion coefficient (ADC) to predict malignancy in head and neck tumors.Patients and methods
HASTE DW images of 33 patients with head and neck tumors (10 benign and 23 malignant) were evaluated. Using the IVIM technique, parameters (D, true diffusion coefficient; f, perfusion fraction; D*, pseudodiffusion coefficient) were calculated for each tumor. ADC values were measured over a range of b values from 0 to 1000 s/mm2. IVIM parameters and ADC values in benign and malignant tumors were compared using Student's t test, receiver operating characteristics (ROC) analysis, and multivariate logistic regression modeling.Results
Mean ADC and D values of malignant tumors were significantly lower than those of benign tumors (P < 0.05). Mean D* values of malignant tumors were significantly higher than those of benign tumors (P < 0.05). There was no significant difference in mean f values between malignant and benign tumors (P > 0.05). The technique of combining D and D* was the best for predicting malignancy; accuracy for this model was higher than that for ADC.Conclusions
The IVIM technique may be applied in HASTE DWI as a diagnostic tool to predict malignancy in head and neck masses. The use of D and D* in combination increases the diagnostic accuracy in comparison with ADC. 相似文献9.
Hyunkyung Yoo Hee Jung Shin Seunghee Baek Joo Hee Cha Hyunji Kim Eun Young Chae Hak Hee Kim 《Magnetic resonance imaging》2014
Purpose
To evaluate the diagnostic performance of an apparent diffusion coefficient (ADC) and quantitative kinetic parameters in patients with newly diagnosed breast cancer.Materials and Methods
We enrolled 169 lesions in 89 patients with breast cancer who underwent dynamic contrast-enhanced MRI (DCE-MRI) and diffusion-weighted imaging (DWI). Comparisons between benign and malignant lesions were performed for lesion type (mass or nonmass-like enhancement), size (≥ 1 cm or < 1 cm), ADC, kinetic parameters and the presence of a US correlate.Results
There were 63 benign and 106 malignant lesions. The mean size and initial peak enhancement of the benign lesions were significantly lower than those of malignant lesions (P < 0.001 for both). The ADC of the benign lesions was significantly higher than that of malignant lesions (1.42 × 10− 3 mm2/sec vs. 1.04 × 10− 3 mm2/sec; P < 0.001). The area under the receiver operating characteristic curve (AUC) for predicting malignancy was 0.87 for the combined parameters of size, ADC, and initial peak enhancement, which was higher than those of each parameter.Conclusions
Combination of quantitative kinetic parameters and ADC showed higher diagnostic performance for predicting malignancy than each parameter alone for the evaluation of patients with breast cancer. 相似文献10.
Xiuzhong Yao Tiantao Kuang Li Wu Hao Feng Hao Liu Weizhong Cheng Shengxiang Rao He Wang Mengsu Zeng 《Magnetic resonance imaging》2014
Objectives
To investigate and optimize diffusion-weighted imaging (DWI) acquisitions for pancreatic cancer at 3.0 T.Methods
Forty-five patients with pancreatic cancer were examined by four DWI acquisitions with b values = 0 and 600 s/mm2 at 3.0 T, including breath-holding DWI (BH-DWI), respiratory-triggered DWI (TRIG-DWI), respiratory-triggered DWI with inversion–recovery technique (TRIGIR-DWI), and free-breathing DWI with inversion–recovery technique (FBIR-DWI). Artifacts, contrast ratio (CR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) of pancreatic cancer were statistically compared among DWI acquisitions.Results
TRIGIR-DWI displayed the lowest artifacts and highest CR compared to other DWI acquisitions. CNRs of pancreatic cancer in TRIG-DWI and TRIGIR-DWI were statistically higher than that in FBIR-DWI and BH-DWI. Different ADCs between pancreatic cancer and noncancerous pancreatic tissues were noticed by a paired-samples T test in TRIG-DWI (p = 0.017), TRIGIR-DWI (p = 0.00001) and FBIR-DWI (p = 0.000041).Conclusions
TRIGIR-DWI may be the optimal acquisition of DWI for pancreatic cancer at 3.0 T. 相似文献11.
Szilvia A. Nagy Mihaly Aradi Gergely Orsi Gabor Perlaki David Olayinka Kamson Andrea Mike Hedvig Komaromy Attila Schwarcz Arpad Kovacs Jozsef Janszky Zoltan Pfund Zsolt Illes Peter Bogner 《Magnetic resonance imaging》2013
Purpose
Our aim was to characterize bi-exponential diffusion signal changes in normal appearing white matter of multiple sclerosis (MS) patients.Methods
Diffusion parameters were measured using mono-exponential (0–1000 s/mm2) and bi-exponential (0–5000 s/mm2) approaches from 14 relapsing-remitting subtype of MS patients and 14 age- and sex-matched controls after acquiring diffusion-weighted images on a 3T MRI system. The results were analyzed using parametric or nonparametric tests and multiple linear regression models.Results
Mono-exponential apparent diffusion coefficient (ADC) slightly increased in controls (P=.09), but decreased significantly in MS as a function of age, nonetheless an elevated ADC was observed with increasing lesion number in patients. Bi-exponential analyses showed that the increased ADC is the result of decreased relative volume fraction of slow diffusing component (fs). However, the fast and slow diffusion components (ADCf, ADCs) did not change as a function of either age in controls or lesion number and age in MS patients.Conclusions
These data demonstrated that the myelin content of the white matter affects diffusion in relapsing-remitting subtype of multiple sclerosis that is possibly a consequence of the shift between different water fractions. 相似文献12.
Jung Jae Park Chan Kyo Kim Sung Yoon Park Arjan W. Simonetti EunJu Kim Byung Kwan Park Seung Jae Huh 《Magnetic resonance imaging》2014
Purpose
To investigate diffusion-weighted (DWI) and dynamic contrast-enhanced MR imaging (DCE-MRI) as early response predictors in cervical cancer patients who received concurrent chemoradiotherapy (CCRT).Materials and methods
Sixteen patients with cervical cancer underwent DWI and DCE-MRI before CCRT (preTx), at 1 week (postT1) and 4 weeks (postT2) after initiating treatment, and 1 month after the end of treatment (postT3). At each point, apparent diffusion coefficient (ADC) and DCE-MRI parameters were measured in tumors and gluteus muscles (GM). Tumor response was correlated with imaging parameters or changes in imaging parameters at each point.Results
At each point, ADC, Ktrans and Ve in tumors showed significant changes (P < 0.05), as compared with those of GM (P > 0.05). PostT1 tumor ADCs showed a significant correlation with tumor size response at postT2 (P = 0.041), and changes in tumor ADCs at postT1 had a significant correlation with tumor size (P = 0.04) and volume response (P = 0.003) at postT2. In tumors, preTx Ktrans and Ve showed significant correlations with tumor size at postT3 (P = 0.011) and tumor size response at postT2 (P = 0.019), respectively.Conclusion
DWI and DCE-MRI, as early biomarkers, have the potential to evaluate therapeutic responses to CCRT in cervical cancers. 相似文献13.
Lei Jiang Yiming Zhou Cheng Zhou Min Chen Yongming Dai Yuan Fu Xuna Zhao 《Magnetic resonance imaging》2014
Purpose
To investigate the influence of dual-source parallel radiofrequency (RF) excitation on clinical breast MR images.Methods
A 3 T MR system with both dual-source and conventional single-source RF excitations was used to examine 22 patients. Axial TSE-T2WI with fat suppression, TSE-T1WI without fat suppression, THRIVE (3D field echo) and DWI (SE-EPI) were obtained by using both excitation techniques. Image homogeneity, image contrast and lesion conspicuity were measured or independently scored by two radiologists and were compared by paired-sample t test or Wilcoxon test.Results
Both excitations revealed 24 lesions. For SE sequences using dual-source mode, image homogeneity was improved (P = 0.00), scan time was reduced, and ghost artifacts on DWI were significantly reduced (P = 0.00). However, image contrast was not increased and lesion conspicuity had no significant difference between two modes, except DWI on which lesion conspicuity was significantly improved (P = 0.00), due to less ghost artifacts. For field-echo sequence, image homogeneity, acquisition time, image contrast and lesion conspicuity had no significant difference between the two modes.Conclusions
Dual-source parallel RF transmission has some added value for improving breast image quality. However, its value is limited in terms of improving lesion detection and characterization. 相似文献14.
Yue Zhang Ning Jin Jie Deng Yang Guo Sarah B. White Guang-Yu Yang Reed A. Omary Andrew C. Larson 《Magnetic resonance imaging》2013
Rationale and Objectives
To compare the apparent diffusion coefficient (ADC) and the perfusion fraction measured by intra-voxel incoherent motion (IVIM) Magnetic Resonance Imaging (MRI) with liver fibrosis degrees in a rodent model.Materials and Methods
All experiments received approval from our institutional animal care and use committee. Liver fibrosis was induced in 13 rats by oral gavage with diethylnitrosamine; 4 untreated rats with normal livers were used as controls. Diffusion Weighted MRI was performed and 8 gradient factors (0, 50, 100, 150, 200, 300, 400 and 500 s/mm2) were acquired. The values of ADC, true diffusion coefficient D and perfusion fraction f were measured based on Li Bihan’s method. The percentage of liver fibrosis was assessed via quantitative analysis of Masson trichrome staining using an average of 30 fields per section. The MRI measurements were compared to the histological fibrotic grade to evaluate the correlation between them.Results
ADC contained the contribution of diffusion and perfusion. The ADC and f values decreased significantly with the increasing fibrosis level (correlation coefficient: ADC: ρ = − 0.781, p < 0.001; f: ρ = − 0.720, p = 0.001); but D was poorly correlated with fibrosis level (ρ = − 0.502, p = 0.040).Conclusion
The hepatic ADC and the perfusion fraction f were significantly correlated with the liver fibrosis level; however, D was not. This might suggest that hepatic perfusion is altered during the progression of hepatic fibrosis. 相似文献15.
Objective
To evaluate the correlation between findings from diffusion weighted imaging (DWI) and microvascular density (MVD) measurements in VX2 liver tumors after transarterial embolization ablation (TEA).Materials and Methods
Eighteen New Zealand white rabbits were used in this study. VX2 tumor cells were implanted in livers by percutaneous puncture under computed tomography (CT) guidance. Two weeks later, all rabbits underwent conventional magnetic resonance imaging (MRI) (T1 and T2 imaging), DWI, (b = 100, 600, and 1000 s/mm2) and TEA. MRI was performed again1 week after TEA. Liver tissue was then harvested and processed for hematoxylin and eosin (H&E) staining and immunohistochemical staining for CD31to determine MVD.Results
VX2 liver tumors were successfully established in all 18 rabbits. Optimal contrast was achieved with a b value of 600 s/mm2.The maximum pre-operative apparent diffusion coefficient (ADC)difference value was 0.28 × 10− 3 ± 0.10 × 10− 3 mm2/s, and was significantly different (P < 0.001) from the maximum postoperative ADCdifference value of 0.47 × 10− 3 ± 0.10 × 10− 3 mm2/s. However, the mean ADC value for the entire tumor was not significantly correlated with MVD (r = 0.221, P = 0.379), nor was the ADC value for the regions of viable tumor (r = − 0.044, P = 0.862). However, the maximum postoperative ADCdifference value was positively correlated with MVD(r = 0.606, F = 12.247, P = 0.003).Conclusion
DWI is effective to evaluate the therapeutic efficacy of TEA. The maximum ADCdifference offers a promising new method to noninvasively assess tumor angiogenesis. 相似文献16.
Janina Klasen Rotem Shlomo Lanzman Hans-Jörg Wittsack Gerald Kircheis Julia Schek Michael Quentin Gerald Antoch Dieter Häussinger Dirk Blondin 《Magnetic resonance imaging》2013
Objective
The purpose of this study was to assess the influence of liver cirrhosis and portal hypertension on diffusion coefficients of the spleen.Material and Methods
We retrospectively evaluated 50 patients with liver cirrhosis and 50 patients without any history of liver disease who underwent magnetic resonance imaging of the upper abdomen, including echo planar diffusion-weighted imaging using b values of 50, 300 and 600 mm2/s. Spleen apparent diffusion coefficient (ADC), liver ADC, muscle ADC and normalized spleen ADC (defined as the ratio of spleen ADC to muscle ADC) were compared between cirrhotic patients and patients in the control group and correlated with Child–Pugh stages. Reproducibility was assessed by measuring interclass correlation coefficient (n = 11). Additionally, in eight patients, ADC measurements were performed 1 day before and 3 days after transjugular intrahepatic portosystemic shunt (TIPSS) implantation.Results
Compared with control subjects, patients with cirrhosis and portal hypertension had significantly higher spleen ADCs (P = .0001). There was a statistically significant correlation between Child–Pugh grade and spleen ADC (Pearson correlation coefficient, observer 1 r = 0.6, P = .0001; observer 2 r = 0.5, P = .0001). After TIPSS implantation, we observed a reduction in spleen ADC values. Spleen ADC measurements showed a high reproducibility (interclass correlation coefficient 0.75, P = .001).Conclusion
Our data suggest that different stages of liver cirrhosis and portal hypertension correlate with ADC values of the spleen. Furthermore, ADC values of the spleen decrease after TIPSS implantation. Further studies are required to understand the potential clinical values of these observations. 相似文献17.
Purpose
To compare the diagnostic performance of the noncontrast MRI including DWI to the standard MRI for detecting hepatic malignancies in patients with chronic liver disease.Materials and methods
We included 135 patients with 136 histologically-confirmed hepatocellular carcinomas (HCCs), 12 cholangiocarcinomas, and 34 benign lesions (≤ 2.0 cm), and 22 patients with cirrhosis but no focal liver lesion who underwent 3.0 T liver MRI. Noncontrast MRI set (T1- and T2-weighted images and DWI) and standard MRI set (gadoxetic acid-enhanced and noncontrast MRI) were analyzed independently by three observers to detect liver malignancies using receiver operating characteristic analysis.Results
The Az value of the noncontrast MRI (mean, 0.906) was not inferior to that of the combined MRI (mean, 0.924) for detecting malignancies by all observers (P > 0.05). For each observer, no significant difference was found in the sensitivity and specificity between the two MRI sets for detecting liver malignancies and distinguishing them from benign lesions (P > 0.05), whereas negative predictive value was higher with the combined MRI than with the noncontrast MRI (P = 0.0001). When using pooled data, the sensitivity of the combined MRI (mean 94.8%) was higher than that of the noncontrast MRI (mean, 91.7%) (P = 0.001), whereas specificity was equivalent (78.6% vs 77.5%).Conclusion
Noncontrast MRI including DWI showed reasonable performance compared to the combined gadoxetic acid-enhanced and noncontrast MRI set for detecting HCC and cholangiocarcinoma and differentiating them from benign lesions in patients with chronic liver disease. 相似文献18.
Yoshihiko Ooka Fumihiko Kanai Shinichiro Okabe Takuya Ueda Ryota Shimofusa Sadahisa Ogasawara Tetsuhiro Chiba Yasunori Sato Masaharu Yoshikawa Osamu Yokosuka 《Magnetic resonance imaging》2013
Purpose
To assess the value of gadoxetic acid-enhanced magnetic resonance imaging (MRI) for the pre-therapeutic detection of hepatocellular carcinoma (HCC) using receiver operating characteristic (ROC) analysis with the combination of computed tomography (CT) arterial portography and CT hepatic arteriography (CTAP/CTHA).Materials and Methods
A total of 54 consecutive patients with 87 nodular HCCs were retrospectively analyzed. All HCC nodules were confirmed pathologically. Three blinded readers independently reviewed 432 hepatic segments, including 78 segments with 87 HCCs. Each reader read two sets of images: Set 1, CTAP/CTHA; Set 2, gadoxetic acid-enhanced MRI including a gradient dual-echo sequence and diffusion-weighted imaging (DWI). The ROC method was used to analyze the results. The sensitivity, specificity, positive predictive value, negative predictive value and sensitivity according to tumor size were evaluated.Results
For each reader, the area under the curve was significantly higher for Set 2 than for Set 1. The mean area under the curve was also significantly greater for Set 2 than for Set 1 (area under the curve, 0.98 vs. 0.93; P = .0009). The sensitivity was significantly higher for Set 2 than for Set 1 for all three readers (P = .012, .013 and .039, respectively). The difference in the specificity, positive predictive values and negative predictive values of the two modalities for each reader was not significant (P > .05).Conclusion
Gadoxetic acid-enhanced MRI including a gradient dual-echo sequence and DWI is recommended for the pre-therapeutic evaluation of patients with HCC. 相似文献19.
Shintaro Ichikawa Utaroh MotosugiTomoaki Ichikawa Katsuhiro SanoHiroyuki Morisaka Tsutomu Araki 《Magnetic resonance imaging》2013
Purpose
To investigate the relationship between estimated glomerular filtration rate (eGFR) and parameters calculated using intravoxel incoherent motion (IVIM) imaging of the kidneys.Materials and Methods
We studied 365 patients, divided into 4 groups based on eGFR levels (mL/min/1.73 m2): group 1, eGFR ≥ 80(n = 80); group 2, eGFR 60–80 (n = 156); group 3, eGFR 30–60 (n = 114); and group 4 ,eGFR < 30 (n = 15). IVIM imaging was used to acquire diffusion-weighted images at 12 b values. The diffusion coefficient of pure molecular diffusion (D), the diffusion coefficient of microcirculation or perfusion (D*), and perfusion fraction (f) were compared among the groups using group 1 as control.Results
In the renal cortex, D* values were significantly lower in groups 2, 3, and 4 than in group 1. The D value of renal cortex was significantly low in only group 3. In the renal medulla, the D* and D values were significantly lower only in groups 2 and 3, respectively.Conclusion
As renal dysfunction progresses, renal perfusion might be reduced earlier and affected more than molecular diffusion in the renal cortex. These changes are effectively detected by IVIM MR imaging. 相似文献20.
Yang Shin Park Chang Hee Lee Ji Hoon Kim Baek Hui Kim Jeoung Hyun Kim Kyeong Ah. Kim Cheol Min Park 《Magnetic resonance imaging》2014