共查询到20条相似文献,搜索用时 31 毫秒
1.
Jared Guthrie Cobb Ke Li Jingping Xie Daniel F. Gochberg John C. Gore 《Magnetic resonance imaging》2014
Purpose
Magnetic resonance images of biological media based on chemical exchange saturation transfer (CEST) show contrast that depends on chemical exchange between water and other protons. In addition, spin–lattice relaxation rates in the rotating frame (R1ρ) are also affected by exchange, especially at high fields, and can be exploited to provide novel, exchange-dependent contrast. Here, we evaluate and compare the factors that modulate the exchange contrast for these methods using simulations and experiments on simple, biologically relevant samples.Methods
Simulations and experimental measurements at 9.4 T of rotating frame relaxation rate dispersion and CEST contrast were performed on solutions of macromolecules containing amide and hydroxyl exchanging protons.Results
The simulations and experimental measurements confirm that both CEST and R1ρ measurements depend on similar exchange parameters, but they manifest themselves differently in their effects on contrast. CEST contrast may be larger in the slow and intermediate exchange regimes for protons with large resonant frequency offsets (e.g. > 2 ppm). Spin-locking techniques can produce larger contrast enhancement when resonant frequency offsets are small (< 2 ppm) and exchange is in the intermediate-to-fast regime. The image contrasts scale differently with field strength, exchange rate and concentration.Conclusion
CEST and R1ρ measurements provide different and somewhat complementary information about exchange in tissues. Whereas CEST can depict exchange of protons with specific chemical shifts, appropriate R1ρ-dependent acquisitions can be employed to selectively portray protons of specific exchange rates. 相似文献2.
Objective
T2 mapping has been used widely in detecting cartilage degeneration in osteoarthritis. Several scanning sequences have been developed in the determination of T2 relaxation times of tissues. However, the derivation of these times may vary from sequence to sequence. This study seeks to evaluate the sequence-dependent differences in T2 quantitation of cartilage, muscle, fat and bone marrow in the knee joint at 3 T.Methods
Three commercial phantoms and 10 healthy volunteers were studied using 3 T MR. T2 relaxation times of the phantoms, cartilage, muscle, subcutaneous fat and marrow were derived using spin echo (SE), multiecho SE (MESE), fast SE (FSE) with varying echo train length (ETL), spiral and spoiler gradient (SPGR) sequences. The differences between these times were then evaluated using Student's t test. In addition, the signal-to-noise ratio (SNR) efficiency and coefficient of variation of T2 from each sequence were calculated.Results
The average T2 relaxation time was 36.38±5.76 ms in cartilage and 34.08±6.55 ms in muscle, ranging from 27 to 45 ms in both tissues. The times for subcutaneous fat and marrow were longer and more varying, ranging from 41 to 143 ms and from 42 to 160 ms, respectively. In FSE acquisition, relaxation time significantly increases as ETL increases (P<.05). In cartilage, the SE acquisition yields the lowest T2 values (27.52±3.10 ms), which is significantly lower than those obtained from other sequences (P<.002). T2 values obtained from spiral acquisition (38.27±6.45 ms) were higher than those obtained from MESE (34.35±5.62 ms) and SPGR acquisition (31.64±4.53 ms). These differences, however, were not significant (P>.05).Conclusion
T2 quantification can be a valuable tool for the diagnosis of degenerative disease. Several different sequences exist to quantify the relaxation times of tissues. Sequences range in scan time, SNR efficiency, reproducibility and two- or three-dimensional mapping. However, when choosing a sequence for quantitation, it is important to realize that several factors affect the measured T2 relaxation time. 相似文献3.
Jesus Lozano Ehsan Saadat Xiaojuan Li Sharmila Majumdar C. Benjamin Ma 《Magnetic resonance imaging》2009
Objective
The objective of this study was to develop quantitative T1ρ-weighted magnetic resonance imaging methodology for the detection and characterization of cartilage degeneration in a rabbit anterior cruciate ligament (ACL) transection model.Methods
The right knee ACLs of 18 adult female New Zealand white rabbits were transected. The left knee joint served as a sham control. The rabbits were euthanized at 3 (Group 1), 6 (Group 2) and 12 (Group 3) weeks postoperatively. High-resolution 3D fat-saturated spoiled gradient echo images and T1ρ-weighted images were obtained in both the sagittal and axial planes at 3 T using a quadrature wrist coil. Following MR analysis, histological slides from the lateral femoral condyle cartilage were graded using the Mankin grading system.Results
For all three groups, the average overall T1ρ values were significantly higher in the ACL-transected knee compared to control knee, and the percentage differences in T1ρ values between ACL-transected and control increased with the duration of time after transection. The average Mankin score for ACL-transected knees was higher than that for control for each time point, but this difference was statistically significant only for all groups combined.Conclusions
This study demonstrates the feasibility of using T1ρ-weighted imaging as a useful tool in the detection and quantification of cartilage damage in all knee compartments in an ACL-transected rabbit model of cartilage degeneration. 相似文献4.
Johannes Tran-Gia Tobias Wech Dietbert Hahn Thorsten A. Bley Herbert Köstler 《Magnetic resonance imaging》2014
Purpose
To include the flip angle distribution caused by the slice profile into the model used for describing the relaxation curves observed in inversion recovery Look–Locker FLASH T1 mapping for a more accurate determination of the relaxation parameters.Materials and methods
For each inversion time, the flip angle dependent signal of the mono-exponential relaxation model is integrated across the slice profile. The resulting Consideration of Slice Profiles (CSP) relaxation curves are compared to the mono-exponential signal model in numerical simulations as well as in phantom and in-vivo experiments.Results
All measured relaxation curves showed systematic deviations from a mono-exponential curve increasing with flip angle and T1 but decreasing with repetition time. Additionally, the accuracy of T1 was found to be largely dependent on the temporal coverage of the relaxation curve. All these systematic errors were largely reduced by the CSP model.Conclusion
The proposed CSP model represents a useful extension of the conventionally used mono-exponential relaxation model. Despite inherent model inaccuracies, the mono-exponential model was found to be sufficient for many T1 mapping situations. However, if only a poor temporal coverage of the relaxation process is achievable or a very precise modeling of the relaxation course is needed as in model-based techniques, the mono-exponential model leads to systematic errors and the CSP model should be used instead. 相似文献5.
Papakonstantinou O Foufa K Benekos O Alexopoulou E Mademli M Balanika A Economopoulos N Kelekis NL 《Magnetic resonance imaging》2012,30(7):926-933
Purpose
To assess the performance and results of R2 relaxometry using a fat-suppressed (FS) multiecho sequence and compare these to conventional R2 relaxometry in estimating tissue iron overload.Materials and Methods
Relaxation rate values (R2=1/T2) of the liver, spleen, pancreas and vertebral bone marrow (VBM) were estimated in 21 patients with β-thalassemia major, using a respiratory-triggered 16-echo Carr-Purcell-Meiboom-Gill (CPMG) spin-echo sequence before (R2) and after (R2 FS) the application of chemically selective fat suppression.Results
Hepatic and splenic R2 FS values correlated with respective R2 values (r=0.98 and r=0.96, P<.001), whereas correlations between R2 FS and R2 values for pancreas and VBM were not statistically significant. Bland–Altman plots show disagreement between R2 and R2 FS values, particularly for pancreas and VBM. Hepatic, pancreatic and VBM R2 FS values correlated with serum ferritin (r=0.88, P<.001; r=0.51, P<.003; and r=0.75, P<.002, respectively). Hepatic R2 FS values correlated with splenic R2 FS (r=0.77, P<.03), pancreatic R2 FS (r=0.61, P<.006) and VBM R2 FS values (r=0.70, P<.001), whereas pancreatic R2 FS values correlated also with VMB R2 FS values. On the contrary, among the R2 values of the above tissues, obtained without fat suppression, only hepatic R2 values correlated with serum ferritin, whereas no correlation was documented between hepatic and pancreatic or VBM R2 values. The application of fat suppression did not improve breathing or flow artifacts.Conclusion
Application of fat suppression in the standard CPMG sequence improved the capability of MRI in noninvasive quantification of iron, particularly in lipid-rich tissues, such as vertebral bone marrow (VBM) and pancreas. 相似文献6.
Purpose
Electron paramagnetic resonance (EPR) oximetry using variable length multi-probe implantable resonator (IR), was used to investigate the temporal changes in the ischemic and contralateral brain pO2 during stroke in rats.Material and methods
The EPR signal to noise ratio (S/N) of the IR with four sensor loops at a depth of up to 11 mm were compared with direct implantation of lithium phthalocyanine (LiPc, oximetry probe) deposits in vitro. These IRs were used to follow the temporal changes in pO2 at two sites in each hemisphere during ischemia induced by left middle cerebral artery occlusion (MCAO) in rats breathing 30% O2 or 100% O2.Results
The S/N ratios of the IRs were significantly greater than the LiPc deposits. A similar pO2 at two sites in each hemisphere prior to the onset of ischemia was observed in rats breathing 30% O2. However, a significant decline in the pO2 of the left cortex and striatum occurred during ischemia, but no change in the pO2 of the contralateral brain was observed. A significant increase in the pO2 of only the contralateral non-ischemic brain was observed in the rats breathing 100% O2. No significant difference in the infarct volume was evident between the animals breathing 30% O2 or 100% O2 during ischemia.Conclusions
EPR oximetry with IRs can repeatedly assess temporal changes in the brain pO2 at four sites simultaneously during stroke. This oximetry approach can be used to test and develop interventions to rescue ischemic tissue by modulating cerebral pO2 during stroke. 相似文献7.
Marion de Roquefeuil Pierre-André Vuissoz Jean-Marie Escanyé Jacques Felblinger 《Magnetic resonance imaging》2013
Object
Quantitative T2 measurement is applied in cardiac Magnetic Resonance Imaging (MRI) for the diagnosis and follow-up of myocardial pathologies. Standard Electrocardiogram (ECG)-gated fast spin echo pulse sequences can be used clinically for T2 assessment, with multiple breath-holds. However, heart rate is subject to physiological variability, which causes repetition time variations and affects the recovery of longitudinal magnetization between TR periods.Materials and methods
The bias caused by heart rate variability on quantitative T2 measurements is evaluated for fast spin echo pulse sequence. Its retrospective correction based on an effective TR is proposed. Heart rate variations during breath-holds are provided by the ECG recordings from healthy volunteers. T2 measurements were performed on a phantom with known T2 values, by synchronizing the sequence with the recorded ECG. Cardiac T2 measurements were performed twice on six volunteers. The impact of T1 on T2 is also studied.Results
Maximum error in T2 is 26% for phantoms and 18% for myocardial measurement. It is reduced by the proposed compensation method to 20% for phantoms and 10% for in vivo measurements. Only approximate knowledge of T1 is needed for T2 correction.Conclusion
Heart rate variability may cause a bias in T2 measurement with ECG-gated FSE. It needs to be taken into account to avoid a misleading diagnosis from the measurements. 相似文献8.
Li X Cheng J Lin K Saadat E Bolbos RI Jobke B Ries MD Horvai A Link TM Majumdar S 《Magnetic resonance imaging》2011,29(3):324-334
Purpose
A direct correlation between T1ρ, T2 and quantified proteoglycan and collagen contents in human osteoarthritic cartilage has yet to be documented. We aimed to investigate the orientation effect on T1ρ and T2 values in human osteoarthritic cartilage and to quantify the correlation between T1ρ, T2 vs. biochemical composition and histology in human osteoarthritic cartilage.Materials and methods
Thirty-three cartilage specimens were collected from patients who underwent total knee arthroplasty due to severe osteoarthritis and scanned with a 3T MR scanner for T1ρ and T2 quantification. Nine specimens were scanned at three different orientations with respect to the B0: 0°, 90° and 54.7°. Core punches were taken after MRI. Collagen and proteoglycan contents were quantified using biochemical assays. Histology sections were graded using Mankin scores. The correlation between imaging parameters, biochemical contents and histological scores were studied.Results
Both mean T1ρ and T2 at 54.7° were significantly higher than those measured at 90° and 0°, with T1ρ showing less increase compared to T2. R1ρ (1/T1ρ) values had a significant but moderate correlation with proteoglycan contents (R=.45, P=.002), while R2 (1/T2) was not correlated with proteoglycan. No significant correlation was found between relaxation times (T1ρ or T2) and collagen contents. The T1ρ values of specimen sections with high Mankin scores were significantly higher than those with low Mankin scores (P<.05).Conclusions
Quantitative MRI has a great potential to provide noninvasive imaging biomarkers for cartilage degeneration in osteoarthritis. 相似文献9.
Purpose
The purpose was to compare T2* relaxation times and proton density fat-fraction (PDFF) values between brown (BAT) and white (WAT) adipose tissue in lean and ob/ob mice.Materials and Methods
A group of lean male mice (n=6) and two groups of ob/ob male mice placed on similar 4-week (n=6) and 8-week (n=8) ad libitum diets were utilized. The animals were imaged at 3 T using a T2*-corrected chemical-shift-based water–fat magnetic resonance imaging (MRI) method that provides simultaneous estimation of T2* and PDFF on a voxel-wise basis. Regions of interest were drawn within the interscapular BAT and gonadal WAT depots on co-registered T2* and PDFF maps. Measurements were assessed using analysis of variance, Bonferroni-adjusted t test for multigroup comparisons and the Tukey post hoc test.Results
Significant differences (P<.01) in BAT T2* and PDFF were observed between the lean and ob/ob groups. The ob/ob animals exhibited longer BAT T2* and greater PDFF than lean animals. However, only BAT PDFF was significantly different (P<.01) between the two ob/ob groups. When comparing BAT to WAT within each group, T2* and PDFF values were consistently lower in BAT than WAT (P<.01). The difference was most prominent in the lean animals. In both ob/ob groups, BAT exhibited very WAT-like appearances and properties on the MRI images.Conclusion
T2* and PDFF are lower in BAT than WAT. This is likely due to variations in tissue composition. The values were consistently lower in lean mice than in ob/ob mice, suggestive of the former's greater demand for BAT thermogenesis and reflective of leptin hormone deficiencies and diminished BAT metabolic activity in the latter. 相似文献10.
LiMn2−XZnXO4 (X<0.5) compounds were prepared by sol-gel method. The specimens with a large substitution degree (X>0.2) led to symmetry reduction from Fdm to P213 in the spinel oxide, while those with a small substitution degree (X<0.1) had Fdm cubic symmetry. The Zn2+-substitution led to the enhancement of the low-temperature magnetic susceptibility and a shift in the Weiss constant from negative to positive, indicating that the dominant exchange interaction changed from antiferromagnetic to ferromagnetic. For the compounds with X=0.5, the spontaneous magnetization was 4.48μB and the Curie temperature was approximately 21 K. The experimentally obtained magnetization value was close to the value calculated under the assumption that the spins of the Mn4+ ions were aligned in ferromagnetic form. In addition, the magnetic properties of Li-Mn-Zn spinel oxides were briefly discussed, and compared with those of Li-Mn-M (M=Ni, Mg) spinel oxides. 相似文献
11.
Elisabeth Pittschieler Pavol Szomolanyi Martina Schmid-Schwap Michael Weber Monika Egerbacher Hannes Traxler Siegfried Trattnig 《Magnetic resonance imaging》2014
Objective
To 1) test the feasibility of delayed Gadolinium-Enhanced Magnetic Resonance Imaging of Cartilage (dGEMRIC) at 3 T in the temporomandibular joint (TMJ) and 2) to determine the optimal delay for measurements of the TMJ disc after i.v. contrast agent (CA) administration.Design
MRI of the right and left TMJ of six asymptomatic volunteers was performed at 3 T using a dedicated coil. 2D inversion recovery (2D-IR) sequences were performed at 4 time points covering 120 minutes and 3D gradient-echo (3D GRE) dual flip-angle sequences were performed at 14 time points covering 130 minutes after the administration of 0.2 mmol/kg of Gd-diethylenetriamine pentaacetic acid ion (Gd-DTPA)2-, i.e., 0.4 mL of Magnevist™ per kg body weight. Pair-wise tests were used to assess differences between pre-and post-contrast T1 values.Results
2D-IR sequences showed a statistically significant drop (p < 0.001) in T1 values after i.v. CA administration. The T1 drop of 50% was reached 60 minutes after bolus injection in the TMJ disc. The 3D GRE dual flip-angle sequences confirmed these results and show plateau of T1 after 60 minutes.Conclusions
T1(Gd) maps calculated from dGEMRIC data allow in vivo assessment of the fibrocartilage disc of the TMJ. The recommended measurement time for dGEMRIC in the TMJ after i.v. CA administration is from 60 to 120 minutes. 相似文献12.
Background
Ultrasound tissue harmonic signal generally provides superior image quality as compared to the linear signal. However, since the generation of the tissue harmonic signal is based on finite amplitude distortion of the propagating waveform, the penetration and the sensitivity in tissue harmonic imaging are markedly limited because of the low signal-to-noise ratio (SNR).Methods
The method of third harmonic (3f0) transmit phasing can improve the tissue harmonic SNR by transmitting at both the fundamental (2.25 MHz) and the 3f0 (6.75 MHz) frequencies to achieve mutual enhancement between the frequency-sum and the frequency-difference components of the second harmonic signal. To further increase the SNR without excessive transmit pressure, coded excitation can be incorporated in 3f0 transmit phasing to boost the tissue harmonic generation.Results
Our analyses indicate that the phase-encoded Golay excitation is suitable in 3f0 transmit phasing due to its superior transmit bandwidth efficiency. The resultant frequency-sum and frequency-difference components of tissue harmonic signal can be simultaneously Golay-encoded for SNR improvement. The increase of the main-lobe signal with the Golay excitation in 3f0 transmit phasing are consistent between the tissue harmonic measurements and the simulations. B-mode images of the speckle generating phantom also demonstrate the increases of tissue harmonic SNR for about 11 dB without noticeable compression artifacts.Conclusion
For tissue harmonic imaging in combination with the 3f0 transmit phasing method, the Golay excitation can provide further SNR improvement. Meanwhile, the axial resolution can be effectively restored by pulse compression while the lateral resolution remains unchanged. 相似文献13.
Riti Gupta Warapat Virayavanich Daniel Kuo Favian Su Thomas Link Benjamin Ma Xiaojuan Li 《Magnetic resonance imaging》2014
Objective
Quantitative T1ρ MRI has been suggested as a promising tool to detect changes in cartilage composition that are characteristic of cartilage damage and degeneration. The objective of this study was to evaluate the capability of MR T1ρ to detect cartilage lesions as evaluated by arthroscopy in acutely ACL-injured knees and to compare with the Whole-Organ Magnetic Resonance Imaging Score (WORMS) using clinical standard MRI.Method
Ten healthy controls (mean age 35) with no ACL injury or history of osteoarthritis (OA) and 10 patients with acute ACL injuries (mean age 39) were scanned at 3 Tesla (3 T). ACL patients underwent ACL reconstruction, where focal lesions were graded according to an Outerbridge grading system during arthroscopic evaluation. Normalized MR T1ρ values (T1ρ z-scores normalized to control values in matched regions) in full thickness, and superficial and deep layers of cartilage were compared between defined sub-compartments with and without focal lesions. Intraclass (ICC) correlation and the root mean square coefficient of variation (RMS-CV) were performed to evaluate the inter-observer reproducibility of T1ρ quantification. Sub-compartments of cartilage were also evaluated using WORMS scoring and compared to their Outerbridge score respectively.Results
The inter-observer ICC and the RMS-CV of the sub-compartment T1ρ quantification were 0.961 and 3.9%, respectively. The average T1ρ z-scores were significantly increased in sub-compartments with focal lesions compared to those without focal lesions and to the control cohort (p < 0.05).Conclusion
Our results indicate that T1ρ provided a better diagnostic capability than clinical standard MRI grading in detecting focal cartilage abnormalities after acute injuries. Quantitative MRI may have great potential in detecting cartilage abnormalities and degeneration non-invasively, which are occult with standard morphological MRI. 相似文献14.
Morita S Saito N Suzuki K Ohnishi T Imura C Mitsuhashi N 《Magnetic resonance imaging》2008,26(9):1244-1249
Purpose
To compare the degree of visualization of the bile duct and portal vein in terms of the difference in k-space ordering on a three-dimensional (3D) segmented true fast imaging with steady-state precession (trueFISP) sequence.Materials and Methods
A breath-hold coronal 3D segmented trueFISP sequence was prospectively performed on 14 healthy volunteers. Images obtained with centric and linear k-space ordering in the k(x)–k(y) plane were compared by two independent radiologists qualitatively with depiction scores on a five-point scale (1=not seen to 5=excellent depiction) using the Wilcoxon signed-rank test. Images were also compared quantitatively using relative contrast values for the bile duct and portal vein against the hepatic parenchyma using a paired t-test.Results
With centric ordering, both the mean depiction scores and relative contrast values for the portal vein were significantly lower than those with linear ordering (1.5 vs. 3.5, P<.01; and 0.08±0.19 vs. 0.51±0.10, P<.01, respectively). However, in the bile duct, there were no significant differences, only slight differences were found among the results obtained with centric and linear ordering (3.9 vs. 3.8, P=.72; and 0.59±0.06 vs. 0.68±0.06, P<.01, respectively).Conclusion
For visualizing the bile duct, centric k-space ordering on 3D segmented trueFISP sequence is recommended, while linear ordering is recommended for portal vein visualization. 相似文献15.
Purpose
To develop a method for estimating metabolite concentrations using phased-array coils and sensitivity-encoded (SENSE) magnetic resonance spectroscopic images (MRSI) of the human brain.Materials and Methods
The method is based on the phantom replacement technique and uses receive coil sensitivity maps and body-coil loading factors to account for receive B1 inhomogeneity and variable coil loading, respectively. Corrections for cerebrospinal fluid content from the MRSI voxel were also applied, and the total protocol scan time was less than 15 min. The method was applied to 10 normal human volunteers using a multislice 2D-MRSI sequence at 3 T, and seven different brain regions were quantified.Results
N-Acetyl aspartate (NAA) concentrations varied from 9.7 to 14.7 mM, creatine (Cr) varied from 6.6 to 10.6 mM and choline (Cho) varied from 1.6 to 3.0 mM, in good general agreement with prior literature values.Conclusions
Quantitative SENSE-MRSI of the human brain is routinely possible using an adapted phantom-replacement technique. The method may also be applied to other MRSI techniques, including conventional phase encoding, with phased-array receiver coils, provided that coil sensitivity profiles can be measured. 相似文献16.
In this study, nano-scale precursors of ZnO, SiO2, and MnO2 powders were used to prepare mixtures with the compositions of 2ZnO+SiO2+X mol% MnO2 (X=MnO2/2ZnO, abbreviated as Zn2SiO4-X-MnO2), where 2≤X≤5. The mixed Zn2SiO4-X-MnO2 mixtures were calcined from 900 to 1300 °C in air in order to synthesize Zn2SiO4:Mn2+ green phosphors. The X-ray diffraction patterns of Zn2SiO4-X-MnO2 particles indicated that ZnO was present in the 900 °C-calcined Zn2SiO4-X-MnO2 phosphors, but not in particles calcined at temperatures of 1000 °C and higher. However, the unapparent secondary phase of ZnMnO3 was found in the 1200 and 1300 °C-calcined Zn2SiO4-5-MnO2 compositions. The luminescent characteristics of Zn2SiO4-X-Mn2+ phosphors were compared with that of a commercial product (Nichia Corp., Japan). The photoluminescence (PL) intensity of 1200 °C-calcined Zn2SiO4-4-MnO2 phosphors was higher and the decay times of all synthesized Zn2SiO4-X-MnO2 phosphors were longer than those of the commercial product. 相似文献
17.
Jannie P. Wijnen Marinette Van der Graaf Tom W.J. Scheenen Dennis W.J. Klomp Bastiaan E. de Galan Albert J.S. Idema Arend Heerschap 《Magnetic resonance imaging》2010
Objectives
As a unique tool to assess metabolic fluxes noninvasively, 13C magnetic resonance spectroscopy (MRS) could help to characterize and understand malignancy in human tumors. However, its low sensitivity has hampered applications in patients. The aim of this study was to demonstrate that with sensitivity-optimized localized 13C MRS and intravenous infusion of [1-13C]glucose under euglycemia, it is possible to assess the dynamic conversion of glucose into its metabolic products in vivo in human glioma tissue.Materials and Methods
Measurements were done at 3 T with a broadband single RF channel and a quadrature 13C surface coil inserted in a 1H volume coil. A 1H/13C polarization transfer sequence was applied, modified for localized acquisition, alternatively in two (50 ml) voxels, one encompassing the tumor and the other normal brain tissue.Results
After about 20 min of [1-13C]glucose infusion, a [3-13C]lactate signal appeared among several resonances of metabolic products of glucose in MR spectra of the tumor voxel. The resonance of [3-13C]lactate was absent in MR spectra from contralateral tissue. In addition, the intensity of [1-13C]glucose signals in the tumor area was about 50% higher than that in normal tissue, likely reflecting more glucose in extracellular space due to a defective blood–brain barrier. The signal intensity for metabolites produced in or via the tricarboxylic acid (TCA) cycle was lower in the tumor than in the contralateral area, albeit that the ratios of isotopomer signals were comparable.Conclusion
With an improved 13C MRS approach, the uptake of glucose and its conversion into metabolites such as lactate can be monitored noninvasively in vivo in human brain tumors. This opens the way to assessing metabolic activity in human tumor tissue. 相似文献18.
George A. Alexiou Anastasia Zikou Spyridon Tsiouris Anna Goussia Paraskevi Kosta Athanasios Papadopoulos Spyridon Voulgaris Pericles Tsekeris Athanasios P. Kyritsis Andreas D. Fotopoulos Maria I. Argyropoulou 《Magnetic resonance imaging》2014
Introduction
Treatment induced necrosis is a relatively frequent finding in patients treated for high-grade glioma. Differentiation by imaging modalities between glioma recurrence and treatment induced necrosis is not always straightforward. This is a comparative study of diffusion tensor imaging (DTI), dynamic susceptibility contrast MRI and 99mTc-Tetrofosmin brain single-photon emission computed tomography (SPECT) for differentiation of recurrent glioma from treatment induced necrosis.Methods
A prospective study was made of 30 patients treated for high-grade glioma who had suspected recurrent tumor on follow-up MRI. All had been treated by surgical resection of the tumor followed by standard postoperative radiotherapy with chemotherapy. No residual tumor had been found on brain imaging immediately after the initial treatment. All the patients were studied with dynamic susceptibility contrast brain MRI and, within a week, 99mTc-Tetrofosmin brain SPECT.Results
Both 99mTc-Tetrofosmin brain SPECT and dynamic susceptibility contrast MRI could discriminate between tumor recurrence and treatment induced necrosis with 100% sensitivity and 100% specificity. An apparent diffusion coefficient (ADC) ratio cut-off value of 1.27 could differentiate recurrence from treatment induced necrosis with 65% sensitivity and 100% specificity and a fractional anisotropy (FA) ratio cut-off value of 0.47 could differentiate recurrence from treatment induced necrosis with 57% sensitivity and 100% specificity. A significant correlation was demonstrated between 99mTc-Tetrofosmin uptake ratio and rCBV (P = 0.003).Conclusions
Dynamic susceptibility contrast MRI and brain SPECT with 99mTc-Tetrofosmin had the same accuracy and may be used to detect recurrent tumor following treatment for glioma. DTI also showed promise for the detection of recurrent tumor, but was inferior to both dynamic susceptibility contrast MRI and brain SPECT. 相似文献19.
Background
High-frequency Doppler imaging is highly potential for detection of blood flow in microcirculation. In a swept-scan system, however, the spectral broadening of tissue clutter limits the detectability of low-velocity flow signal. Conventionally, the scanning speed of transducer has to be reduced to alleviate the clutter interference but at the cost of imaging frame rate. For example, the blood velocity of 0.5 mm/s becomes detectable only with a scanning speed lower than 1 mm/s. In this study, an alternative method is examined by suppressing the clutter magnitude to reduce the interference to flow signal without sacrificing scanning speed.Methods
The method of third harmonic (3f0) transmit phasing can suppress the tissue harmonic clutter by transmitting at the fundamental and the additional 3f0 frequencies to achieve mutual cancellation between the frequency-sum and the frequency-difference components of the second harmonic signal. With 3f0 transmit phasing, the cut-off frequency of wall filtering can be reduced to preserve low-velocity flow without compromising the frame rate.Results
Our results indicate that the 3f0 transmit phasing effectively reduces the harmonic clutter magnitude and thus improves the flow signal-to-clutter ratio. Compared to the conventional counterpart, the clutter-suppressed color flow and power Doppler images show fewer clutter artifacts and is capable of detecting more low-velocity flow of microbubbles. The resultant color-pixel-density also improves with clutter suppression.Conclusion
For the swept-scan high-frequency (>20 MHz) system, 3f0 transmit phasing is capable of providing effective clutter suppression. With the same achievable scanning speed, the resultant Doppler image has higher sensitivity for low-velocity flow and is less susceptible to clutter artifacts. 相似文献20.
Szilvia A. Nagy Mihaly Aradi Gergely Orsi Gabor Perlaki David Olayinka Kamson Andrea Mike Hedvig Komaromy Attila Schwarcz Arpad Kovacs Jozsef Janszky Zoltan Pfund Zsolt Illes Peter Bogner 《Magnetic resonance imaging》2013