首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到4条相似文献,搜索用时 0 毫秒
1.

Purpose

To investigate the correlation between perfusion-related parameters obtained with intravoxel incoherent motion (IVIM) and classical perfusion parameters obtained with dynamic contrast-enhanced (DCE) magnetic resonance imaging in patients with head and neck squamous cell carcinoma (HNSCC), and to compare direct and asymptotic fitting, the pixel-by-pixel approach, and a region of interest (ROI)-based approach respectively for IVIM parameter calculation.

Materials and methods

Seventeen patients with HNSCC were included in this retrospective study. All magnetic resonance (MR) scanning was performed using a 3 T MR unit. Acquisition of IVIM was performed using single-shot spin-echo echo-planar imaging with three orthogonal gradients with 12 b-values (0, 10, 20, 30, 50, 80, 100, 200, 400, 800, 1000, and 2000). Perfusion-related parameters of perfusion fraction ‘f’ and the pseudo-diffusion coefficient ‘D*’ were calculated from IVIM data by using least square fitting with the two fitting methods of direct and asymptotic fitting, respectively. DCE perfusion was performed in a total of 64 dynamic phases with a 3.2-s phase interval. The two-compartment exchange model was used for the quantification of tumor blood volume (TBV) and tumor blood flow (TBF). Each tumor was delineated with a polygonal ROI for the calculation of f, f ? D* performed using both the pixel-by-pixel approach and the ROI-based approach. In the pixel-by-pixel approach, after fitting each pixel to obtain f, f ? D* maps, the mean value in the delineated ROI on these maps was calculated. In the ROI-based approach, the mean value of signal intensity was calculated within the ROI for each b-value in IVIM images, and then fitting was performed using these values. Correlations between f in a total of four combinations (direct or asymptotic fitting and pixel-by-pixel or ROI-based approach) and TBV were respectively analyzed using Pearson's correlation coefficients. Correlations between f ? D* and TBF were also similarly analyzed.

Results

In all combinations of f and TBV, f ? D* and TBF, there was a significant correlation. In the comparison of f and TBV, a moderate correlation was observed only between f obtained by direct fitting with the pixel-by-pixel approach, whereas a good correlation was observed in the comparisons using the other three combinations. In the comparison of f ? D* and TBF, a good correlation was observed only with f ? D* obtained by asymptotic fitting with the ROI-based approach. In contrast, moderate correlations were observed in the comparisons using the other three combinations.

Conclusion

IVIM was found to be feasible for the analysis of perfusion-related parameters in patients with HNSCC. Especially, the combination of asymptotic fitting with the ROI-based approach was better correlated with DCE perfusion.  相似文献   

2.
Prostate cancer detection using diffusion-weighted imaging is highly affected by the accuracy of the apparent diffusion coefficient (ADC) values in an image. Echo planar imaging (EPI) is a fast sequence commonly used for diffusion imaging but has inherent magnetic susceptibility and chemical shift artefacts associated. A diffusion sequence that is less affected by these artefacts is therefore advantageous. The half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence was chosen. The diffusion sequences were compared in image quality, repeatability of the ADC value and the effect on the ADC value with varied b values. Eight volunteers underwent three scans of each sequence, on a 1.5-T Siemens system, using b values of 0, 150, 300, 450, 600, 750, 900 and 1000 s/mm(2). ADC maps were created to address the reproducibility of the ADC value when using two b values compared to eight b values. The ADC value using all b values with the HASTE sequence gave the best performance in all tested categories. Both sequences gave significantly different ADC mean values for two b values compared to when using eight b values (P<.05) suggesting larger error is present when using two b values. HASTE was shown to be an improvement over EPI in terms of repeatability, signal variation within a region of interest and standard deviation over the volunteer set. The improved accuracy of the ADC value in the HASTE sequence makes it potentially a more sensitive tumor detection technique.  相似文献   

3.

Purpose

To investigate the relationship between estimated glomerular filtration rate (eGFR) and parameters calculated using intravoxel incoherent motion (IVIM) imaging of the kidneys.

Materials and Methods

We studied 365 patients, divided into 4 groups based on eGFR levels (mL/min/1.73 m2): group 1, eGFR ≥ 80(n = 80); group 2, eGFR 60–80 (n = 156); group 3, eGFR 30–60 (n = 114); and group 4 ,eGFR < 30 (n = 15). IVIM imaging was used to acquire diffusion-weighted images at 12 b values. The diffusion coefficient of pure molecular diffusion (D), the diffusion coefficient of microcirculation or perfusion (D*), and perfusion fraction (f) were compared among the groups using group 1 as control.

Results

In the renal cortex, D* values were significantly lower in groups 2, 3, and 4 than in group 1. The D value of renal cortex was significantly low in only group 3. In the renal medulla, the D* and D values were significantly lower only in groups 2 and 3, respectively.

Conclusion

As renal dysfunction progresses, renal perfusion might be reduced earlier and affected more than molecular diffusion in the renal cortex. These changes are effectively detected by IVIM MR imaging.  相似文献   

4.

Purposes

To evaluate the diagnostic value of diffusion-weighted MRI (DWI) and combination of conventional MRI and DWI to predict metastatic axillary lymph nodes in breast cancer.

Materials and methods

Two hundred fifty-two breast cancer patients with 253 axillae were included. The morphological parameters on axial T2-weighted images without fat saturation and apparent diffusion coefficient (ADC) values were retrospectively analyzed. An independent t-test/chi-square test and receiver operating characteristics (ROC) curve analysis were used.

Results

On conventional MRI, short and long axis length, maximal cortical thickness, relative T2 value, loss of fatty hilum (p < 0.001 for each), and eccentric cortical thickening (p < 0.003) were statistically significantly different between the metastatic and nonmetastatic groups. The short axis to long axis ratio was not a statistically significant parameter. The ADC value was significantly different between the 2 groups, with an AUC that was higher than that of conventional MR parameters (AUC, 0.815; threshold, ≤ 0.986 × 10–3 mm2/sec; sensitivity, 75.8%; specificity, 83.9%). Using the adopted thresholds for each parameter, a total number of findings suggesting malignancy of 4 or higher was determined as the threshold, with high specificity (90.1%).

Conclusion

Using conventional MRI and DWI, we can evaluate the axilla in breast cancer with high specificity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号