首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A liquid chromatographic (LC) method is described for the determination of vitamin K1 in medical foods. The sample is enzymatically digested with lipase and alpha-amylase and extracted with 1% sodium bicarbonate solution-isopropanol (1 + 1). After C18 solid-phase extraction, vitamin K1 is separated by nonaqueous reversed-phase LC, converted to the hydroquinone by postcolumn zinc reduction, and quantitated by fluorescence detection. The limit of detection is 8 pg (3 sigma), and the limit of quantitation is 27 pg (10 sigma) on column. Linear response ranged from 0.1 to 1.0 ng vitamin K1 (r= 0.9999). The mean recovery (n = 38) for all spiking levels was 101.6 +/- 2.85%. Analysis of Standard Reference Material 1846, Infant Formula, gave a mean value of 0.95 +/- 0.088 mg vitamin K/kg (K or K1?) (n = 31) with a coefficient of variation of 9.26.  相似文献   

2.
A liquid chromatographic (LC) method for determining residues of the antiparasitic drugs emamectin (EMA) and ivermectin (IVR) in fish tissues has been developed. EMA and IVR residues are extracted with acetonitrile and cleaned up on a C18 solid-phase extraction column. Extracts are derivatized with 1-methylimidazole and trifluoroacetic anhydride and the components are determined by LC on a C18 reversed-phase column with fluorescence detection (excitation: 365 nm, emission: 470 nm). The mobile phase is 94% acetonitrile-water run isocratically. Calibration curves were linear between 1 and 32 ng injected for both EMA and IVR. The limit of detection for both analytes was 0.5 ng/g, with a limit of quantitation of 1.5 ng/g. Recoveries of EMA and IVR added to salmon muscle averaged 96 +/- 9% and 86 +/- 6%, respectively, at levels between 5 and 80 ng/g. The percent relative standard deviation for the described method was less than 7% over the range of concentrations studied. The operational errors, interferences, and recoveries for fortified samples compare favorably with an established IVR method. The recommended method is simple, rapid, and specific for monitoring residues of EMA and IVR in Atlantic salmon muscle.  相似文献   

3.
A simple procedure for determination of vitamin K1 was developed for routine compliance monitoring of supplemented infant formula and measurement of endogenous levels in milk and milk powders. Samples are digested with lipase and extracted into hexane; and aliquot is evaporated, reconstituted in methanol, and analyzed by reversed-phase LC. Post-column zinc reduction of phylloquinone facilitates detection by fluorescence. The procedure was subjected to an AOAC collaborative study involving 8 materials, each in blind duplicate, across the range of 5-120 micrograms/100 g solids and including NIST 1846 reference material. Thirty-three laboratories returned valid data which were then statistically analyzed for outliers and precision parameters. Mean RSDR (%) was 6.53 (4.33-10.94), with a mean HORRAT value of 0.33 (0.23-0.43) and RSDr:RSDR ratio of 0.74. K1 isomers (cis and trans) were aggregated with conventional C18 columns, but may be selectively estimated with use of the C30 column.  相似文献   

4.
A novel method for the determination of vitamin B12 by high-performance liquid chromatography with fluorescence detection is reported. The method was simple and highly sensitive with good precision. Vitamin B12 was analyzed by HPLC on a muBondapak C18 column (300x3.9 mm, 10 microm) with methanol-water (30:70) as mobile phase and fluorescence detection at 305 nm (with excitation at 275 nm). The calibration graph was linear from 1.000 to 100.0 ng ml(-1) for vitamin B12 with a correlation coefficient of 0.998 (n=6). The detection limit was 0.1 ng ml(-1). The method was successfully applied to the determination of vitamin B12 in vitamin B12 tablets, multivitamin tablets and fermentation medium. The recovery was from 94 to 102% and the relative standard deviation was in the range of 1.8 to 4.1%.  相似文献   

5.
A liquid chromatography (LC) method is presented for the quantitative determination of malachite green (MG) in salmon. MG and leucomalachite green (LMG) residues were extracted from salmon tissue with ammonium acetate buffer and acetonitrile, and then isolated by partitioning into dichloromethane. LMG was quantitatively oxidized to the chromic MG by reaction with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone. Samples were then cleaned up by solid-phase extraction with alumina and propylsulfonic acid phases. Extracts were analyzed for MG by LC with visible detection at 618 nm using isocratic elution and a C18 column. The method was validated in 35 farm-raised salmon (Salmo salar) tissues fortified at 1, 2, 4, and 10 ng/g (ppb) with an average recovery of 95.4% and a relative standard deviation of +/- 11.1%, and in 5 canned salmon (Oncorhynchus gorbuscha) samples fortified at 10 ng/g with an average recovery of 88.9 +/- 2.6%. This study also included the determination of MG and LMG residues in tissues from salmon that had been treated with MG MG was quantitatively determined at the method detection limit of 1 ng/g.  相似文献   

6.
高效液相色谱法测定红葡萄酒中白藜芦醇的四种异构体   总被引:6,自引:0,他引:6  
孙狄  章震兴  王轶男  时卫萍 《色谱》2004,22(4):424-427
将红葡萄酒用β-葡萄糖苷酶水解处理,使其中的白藜芦醇甙转换成白藜芦醇。采用高效液相色谱法测定水解前后顺、反式白藜芦醇含量的变化,从而计算出葡萄酒中白藜芦醇的4种异构体的含量。色谱柱为Symmetry C18柱(3.9 mm i.d.×150 mm),流动相为乙醇-0.05%乙酸水溶液(体积比为23∶77),紫外检测波长为306 nm。实验结果表明:白藜芦醇的4种异构体在其质量浓度为0.2~50.0 mg/L时均有良好的线性关系(r>0.999),白藜芦醇及其甙的顺、反异构体的最小检出量分别为:0.81  相似文献   

7.
A liquid chromatographic (LC) method was developed for determination of abamectin (ABM) and ivermectin (IVM) in cattle plasma. The sample was extracted with acetonitrile and cleaned up on an alumina column. After conversion to stable fluorescent derivative with trifluoroacetic anhydride and N-methylimidazole, the sample was analyzed by LC with fluorescence detection (Ex 365 nm and Em 475 nm). Doramectin was used as an internal standard. Recoveries ranged from 91.2 to 100.7% for IVM and from 87.0 to 98.7% for ABM, with 1-50 ng/mL fortified samples. The coefficients of variation were <10.1%. The limit of detection was 0.02 ng/mL for ABM and IVM in 1.0 mL samples.  相似文献   

8.
A simple, accurate, precise, specific and reproducible high-performance liquid chromatography (HPLC) method was developed for simultaneous determination of resveratrol isomers in rat plasma. Cis-resveratrol was made by exposure of a trans-resveratrol solution to sunlight for 5 days followed by separation by HPLC and identification by mass spectrometry (MS). The assay procedure involved simple liquid-liquid extraction of resveratrol isomers and internal standard (IS, caffeine) from a small plasma volume directly into acetonitrile. The supernatant liquid was added an equal volume of water and injected onto a Hypersil ODS(2) C(18) column (5 microm, 4.6 x 250 mm). Mobile phase consisting of methanol and distilled water was used at a flow rate of 1.0 mL/min for the effective separation of cis-, trans-resveratrol and caffeine (IS). The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 303 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of cis-, trans-resveratrol and IS were 3.2, 4.3 and 6.1 min, respectively. The calibration curve was linear ranging from 0.066 to 6.64 and 0.134 to 13.4 microg/mL with correlation coefficients of 0.9998 and 0.9997 for trans and cis isomers, respectively. The absolute recovery of both isomers was more than 85%. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.066, 0.664 and 6.64 microg/mL of trans-resveratrol, were in the range 2.37-6.95% relative standard deviation (RSD) and 0.77-6.97% RSD, respectively. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.134, 1.34 and 13.4 microg/mL of cis-resveratrol, were in the range 1.93-3.72% relative standard deviation (RSD) and 1.13-6.57% RSD, respectively. Both analytes and IS were stable in the battery of stability studies and freeze-thaw cycles. Resveratrol isomers were found to be stable for a period of 30 days on storage at -20 degrees C. The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described.  相似文献   

9.
A multiresidue liquid chromatography (LC) method was developed to detect avermectin, ivermectin, doramectin, and eprinomectin simultaneously in bovine liver. The extracted samples were cleaned up by an immunoaffinity column, which was prepared by coupling anti-avermectin polyclonal antibody with CNBr-activated Sepharose 4B. The dynamic column capacities of avermectin, ivermectin, doramectin, and eprinomectin were 3531, 3542, 3543, and 3284 nglmL gel, respectively. The eluate was evaporated to dryness, and residues were derivatized and determined by LC with fluorescence detector set at 365 nm excitation and 465 nm emission wavelengths. Recoveries ranged from 79.3 to 115.9% with coefficients of variation of 1.1-19.4% when avermectin, ivermectin, doramectin, and eprinomectin were spiked at levels of 5-100 ng/g. The limit of quantitation of the method was 2 ng/g for each drug.  相似文献   

10.
A precise and selective liquid chromatographic procedure for determining tocopherol and tocotrienol isomers in vegetable oils, formulated preparations, and biscuits was developed and validated. The proposed method quantitates vitamin E in better conditions of recoverability and reproducibility than the standard saponification procedure. Tocopherols and tocotrienols were extracted in hexane from vegetable oils, passed through a silica Sep-pak, chromatographed on a mu-Bondapak C18 column with a mobile phase of methanol-water (95 + 5, v/v), identified at 292 nm, and detected with fluorescence procedure (excitation 296 nm, and emission 330 nm). The correlation coefficient on the calibration curve was 0.9995 over the range of 0.1 to 100 microg/mL. Overall recovery of vitamin E isomers was 93%; coefficients of variation for intra- and interday precision, < 2.25%. The results obtained from extraction methods 1 (with saponification) and 2 (without saponification) were compared by ANOVA test. Significant differences appeared between vitamin E isomers (p < or = 0.05).  相似文献   

11.
A sensitive high-performance liquid chromatographic (HPLC) assay using fluorescence detection for quantifying lidocaine levels in plasma (in the ng/ml range) was developed. This novel HPLC assay has made possible the simultaneous monitoring of lidocaine levels in coronary and peripheral plasma obtained after myocardial controlled-release matrix administration (0.92 mg/kg during 4 h) in the arrhythmic dog. The method employed extracts the drug from plasma using 1-chlorobutane and a subsequent derivatization with 9-fluorenylmethylchloroformate in acetonitrile at 110 degrees C. The derivative was chromatographed on a C18 reversed-phase column and measured with fluorescence detection (excitation 254 nm, emission 313 nm). N-Methylephedrine was found to be suitable as an internal standard, post-derivatization. The derivatization product of lidocaine was identified and characterized by mass spectral analysis. It was found to have a unique and reproducible dicarbamate structure, which was stable for at least three days at room temperature. The method was tested with human plasma as well as on dog plasma. Analytical recoveries were 88.6 +/- 3.6 and 77.4 +/- 3.0% (mean +/- S.E.), respectively, at levels ranging from 25 to 200 ng/ml. The lower detection limit was 1 ng/ml lidocaine. In conclusion, this rapid and convenient analysis was found to be suitable for the bioavailability pharmacokinetic assessment of lidocaine following low-dose regional drug administration.  相似文献   

12.
Four different stability-indicating procedures are described for determination of tiapride in pure form, dosage form, and human plasma. Second derivative (D2), first derivative of ratio spectra (1DD), spectrofluorimetric, and high-performance column liquid chromatographic (LC) methods are proposed for determination of tiapride in presence of its acid-induced degradation products, namely 2-methoxy-5-(methylsulfonyl) benzoic acid and 2-diethylaminoethylamine. These approaches were successfully applied to quantify tiapride using the information included in the absorption, excitation, and emission spectra of the appropriate solutions. In the D2 method, Beer's law was obeyed in the concentration range of 1.5-9 microg/mL with a mean recovery of 99.94 +/- 1.38% at 253.4 nm using absolute ethanol as a solvent. In 1DD, which is based on the simultaneous use of the first derivative of ratio spectra and measurement at 245 nm in absolute ethanolic solution, Beer's law was obeyed over a concentration range of 1.5-9 microg/mL with mean recovery 99.64 +/- 1.08%. The spectrofluorimetric method is based on the determination of tiapride native fluorescence at 339 nm emission wavelength and 230 nm excitation wavelength using water-methanol (8 + 2, v/v). The calibration curve was linear over the range of 0.2-3 microg/mL with mean recovery of 99.66 +/- 1.46%. This method was also applied for determination of tiapride in human plasma. A reversed-phase LC method performed at ambient temperature was validated for determination of tiapride using methanol-deionized water-triethylamine (107 + 93 + 0.16, v/v/v) as the mobile phase. Sulpiride was used as an internal standard at a flow rate of 1 mL/min with ultraviolet detection at 214 nm. A linear relation was obtained over a concentration range of 2-30 microg/mL with mean recovery of 99.66 +/- 0.9%. Results were statistically analyzed and compared with those obtained by applying the reference method. They proved both accuracy and precision.  相似文献   

13.
A liquid chromatographic (LC) method with fluorescence detection (FLD) is described for determining residues of the pesticide azamethiphos (AZA) in salmon tissue. The sample is extracted with ethyl acetate, centrifuged, dehydrated with anhydrous sodium sulfate, evaporated, reconstituted in water, and defatted with hexane. The aqueous phase is passed through a C18 solid-phase extraction (SPE) column. The SPE column is eluted with methanol, and the eluate is evaporated to dryness and then taken up in 10% acetonitrile (ACN) in water. The analyte is determined by LC using a C18 column, ACN-H2O (32 + 68) mobile phase, and FLD with excitation at 230 nm and emission at 345 nm. Composited salmon tissues were fortified with AZA at 5, 10, 21, 42, and 83 ng/g or ppb (target level, X = 10 ng/g). Overall recoveries were 86%, with between-day variability of 5.3%. The method detection limit was calculated as 1.2 ppb AZA based on a 5 g sample. The limit of quantitation as determined empirically by this method is the lower limit of the standard curve, approximately 5 ppb.  相似文献   

14.
高效液相色谱法测定大鼠组织中双酚A和4-壬基酚浓度   总被引:8,自引:0,他引:8  
肖全伟  黎源倩  吴德生 《色谱》2004,22(6):579-582
建立了大鼠组织中双酚A和4-壬基酚的提取和含量测定方法。大鼠组织样品经甲醇-乙酸铵缓冲液匀浆、 正己烷-乙醚混合溶剂提取、氮气吹干后用流动相溶解,以乙腈-0.01 mol/L乙酸铵缓冲液(pH 4.5)(体积比为75∶25)为流动相,经C18色谱柱分离,在激发波长227 nm、发射波长313 nm下进行荧光检测。大鼠心、脑、肝和肾脏组织样品中,双酚A的检出限为3.2~4.6 ng/g,4-壬基酚的检出限为11.8~15.6 ng/g;日内检测精密度为0.89%~4.50%,日间检测精密度为3.10%~12  相似文献   

15.
Simple and rapid reversed-phase gradient column liquid chromatography (LC) with fluorescence detection at different wavelengths was developed for the simultaneous analysis of all-trans, 13-cis, 9-cis retinoic acids, vitamin A palmitate and beta-carotene in galenicals. The assay results agreed with those obtained by an LC method with diode-array UV detection. A post-column on-line photochemical reactor (irradiation at 254 and 366 nm) was inserted between the LC column and the fluorescence detector to enhance the performance of the method. Two fluorescence spectra (photoreactor on and off) were obtained for each analyte which proved useful for the unambiguous identification of the various analytes.  相似文献   

16.
A new method is described for the determination of endogenous jasmonic acid (JA) in Lemna minor plant extracts using liquid chromatography (LC) with fluorescence detection. Plant tissues were extracted and derivatised using 9-anthryldiazomethane (ADAM reagent) prepared in situ. Accuracy and precision were improved by using the internal standard dihydrojasmonic acid (dh-JA) for the correction of JA losses during sample preparation steps. Liquid chromatography–mass spectrometry (LC/MS) analysis of ADAM derivatives of JA and dh-JA confirmed that a single molecule of JA and dh-JA was coupled with one molecule of reagent. Derivatives of JA and dh-JA were separated with gradient elution on a C18 reversed-phase column using acetonitrile/water as a mobile phase and detected by a fluorescence detector at excitation and emission wavelengths of 254 and 412 nm, respectively. The detection limits of JA and dh-JA were 2.9 ng mL−1 and 3.7 ng mL−1 per 50-μL injection. The method is reproducible and selective and yields single peaks for each compound regardless of isomer. The specificity and accuracy of the proposed LC/FD method was confirmed by liquid chromatography–TurboIon Spray tandem mass spectrometric (LC/MS/MS) analysis of free JA in Lemna minor samples under multiple reaction monitoring conditions.  相似文献   

17.
Conditions were optimized for the simultaneous, alkaline, aqueous methanol extraction of aflatoxins (AFL), i.e., B1 (AFB1), B2 (AFB2), G1 (AFG1), and G2 (AFG2), and ochratoxin A (OTA) with subsequent purification, isolation, and determination of the toxins in ginseng and ginger. Powdered roots were extracted with methanol-0.5% NaHCO3 solution (7 + 3). After shaking and centrifugation, the supernatant was diluted with 100 mM phosphate buffer containing 1% Tween 20 and filtered through glass microfiber filter paper. The filtrate was then passed through an immunoaffinity column, and the toxins were eluted with methanol. The AFL were separated and determined by reversed-phase liquid chromatography (RPLC) with fluorescence detection after postcolumn UV photochemical derivatization. OTA was separated and determined by RPLC with fluorescence detection. Recoveries of AFL added at 2-16 ng/g and OTA added at 1-8 ng/g to ginseng were 72-80 and 86-95%, respectively. Recoveries of AFL and OTA added to ginger were similar to those for ginseng. A total of 39 commercially available ginger products from 6 manufacturers were analyzed. Twenty-six samples were found to be contaminated with AFL at 1-31 ng/g and 29 samples, with OTA at 1-10 ng/g. Ten samples contained no AFL or OTA. Ten ginseng finished products were also analyzed; 3 contained AFL at 0.1 ng/g and 4 contained OTA at levels ranging from 0.4 to 1.8 ng/g. LC/tandem mass spectrometry with multiple-reaction monitoring of 3 collisionally induced product ions from the protonated molecular ions of OTA, AFB1, and AFG1 was used to confirm the identities of the toxins in extracts of the finished products.  相似文献   

18.
The concentrations of vitamin A, beta-carotene, and all-trans-retinoic acid in oral preparations were determined in a single analysis by a method based on isocratic, reversed-phase liquid chromatography (LC). The LC system consisted of a C18 column, a mobile phase of acetonitrile, dichloromethane, methanol, and water and a UV detector set at 330 nm. The linearity ranges were 25-250 ng/mL for trans-retinoic acid and vitamin A, and 100-1,000 ng/mL for beta-carotene. This LC method for the determination of retinoids is simple, precise, and accurate. No extraction procedure is required before the chromatographic analysis; only a suitable dilution is necessary. The method proved to be reliable, fast, and economical. Furthermore, this method is indicative of stability, because it allows for the determination of degradation products such as 13-cis-retinoic acid.  相似文献   

19.
The objective of this study was to optimize a method to investigate the occurrence and to quantify the full isomeric composition of vitamin E (α-, β-, γ- and δ-tocopherols and tocotrienols) in 6 vegetables (raw and cooked), 3 herbs/spices, raw and cooked eggs, vegetable oils (canola, olive and soybean), flaxseed and sorghum (flour and seeds) and soy (flour) by HPLC with fluorescence detection. Different conditions of extraction and analysis were tested. The optimized method consisted of direct extraction with solvent (hexane:ethyl acetate, 85:15, v/v). For analysis normal phase column was used with mobile phase consisting of hexane:isopropanol:acetic acid (98.9:0.6:0.5) with isocratic elution and fluorescence detection. Excellent separation of all isomers was obtained along with adequate quantification in the foods analyzed. Recovery rates of standards ranged from 91.3 to 99.4%. The linearity range for each isomer varied from 2.5 to 137.5 ng/mL (R2 greater than 0.995 in all cases). Detection limits ranged from 21.0 to 48.0 ng/mL for tocopherols and from 56.0 to 67.0 ng/mL for tocotrienols, while quantification limits ranged from 105.0 to 240.0 ng/mL for tocopherols and from 280.0 to 335.0 ng/mL for tocotrienols. The optimized method was considered simple, fast and reliable, and also preserved vitamin E isomers when compared to validated methods involving saponification.  相似文献   

20.
H Millart  D Lamiable 《The Analyst》1989,114(10):1225-1228
A very sensitive spectrofluorimetric method for the determination of pyridoxal 5'-phosphate (PLP) in human serum is described. The specificity is based on the selective oxidation of PLP to 4-pyridoxic acid 5'-phosphate with potassium cyanide. Separation of the highly fluorescent 4-pyridoxic acid 5'-phosphate is achieved by reversed-phase high-performance liquid chromatography. Specificity is improved by a careful choice of fluorescence filters, maximised at the excitation (325 nm) and emission (418 nm) wavelengths of 4-pyridoxic acid 5'-phosphate. The detection limit for the reaction is 0.22 ng ml(-1). For quantification, the serum is spiked with PLP before protein precipitation with 3.3% m/V trichloroacetic acid. The method can be used for the determination of PLP in serum, even in vitamin B6 deficient patients. The mean value for human serum PLP from 30 healthy adults was found to be 14.6 +/- 4.8 ng ml(-1) (mean +/- standard deviation).  相似文献   