首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Penindolone (PND) is a novel influenza A virus dual inhibitor that blocks hemagglutinin-mediated adsorption and membrane fusion. A sensitive and specific ultra-performance liquid chromatography–tandem mass spectrometry method was developed and validated to determine PND in rat plasma. Plasma sample preparation was a simple deproteinization with acetonitrile followed by centrifugation. Chromatographic separation was performed on a C18 column with a gradient mobile phase of acetonitrile–water containing 0.1% formic acid. Detection was carried out by electrospray ionization in negative ion multiple reaction monitoring mode. Linear detection responses were obtained for PND ranging from 1 to 1,000 ng/ml. The intra- and inter-day precision (relative standard deviations, RSD) were within 6.5%, and accuracy (relative error, RE) was within ±11.0%. The extraction recovery data for PND and internal standard (IS) were >96.0%. PND was proved to be stable during the sample storage, preparation and analytic procedures. The validated method was successfully applied to pharmacokinetic and bioavailability studies for PND in rats. The results showed the existence of twin peaks, gender difference and nonlinear pharmacokinetics for PND. In addition, two oxidation metabolites and three glucuronidation metabolites of PND were detected by ultra-high-performance liquid chromatography–high resolution mass spectrometry.  相似文献   

2.
Current urinary bladder cancer diagnosis is commonly based on a biopsy obtained during cystoscopy. This invasive method causes discomfort and pain in patients. Recently, taurine and several other compounds such as L-phenylalanine and hippuric acid in urine were found to be indicators of bladder cancer. However, because of a lack of sensitive and accurate analytical techniques, it is impossible to detect these compounds in urine at low levels. In this study, using liquid chromatography–tandem mass spectrometry (LC-MS/MS), a noninvasive method was developed to separate and detect these compounds in urine. 15N2-L-glutamine was used as the internal standard, and creatinine acted as an indicator for urine dilution. A phenyl-hexyl column was used for the separation at an isocratic condition of 0.2% formic acid in water and 0.2% formic acid in methanol. Analytes were detected in multiple-reaction monitoring with positive ionization mode. The limit of detection range is 0.18–6 nM and the limit of quantitation ranges from 0.6 to 17.6 nM. The parameters affecting separation and quantification were also investigated and optimized. Proper clinical validation of these biomarkers can be done using this reliable, fast, and simple method. Furthermore, with simple modifications, this method could be applied to other physiological fluids and other types of diseases.  相似文献   

3.
A sensitive and specific method for the quantitative determination of zearalenone (ZEN) and its major metabolites (α-zearalenol (α-ZEL), β-zearalenol (β-ZEL), α-zearalanol (α-ZAL), β-zearalanol (β-ZAL) and zearalanone (ZAN)) in animal plasma using liquid chromatography combined with heated electrospray ionization (h-ESI) tandem mass spectrometry (LC–MS/MS) and high-resolution Orbitrap® mass spectrometry ((U)HPLC–HR–MS) is presented. The sample preparation was straightforward, and consisted of a deproteinization step using acetonitrile. Chromatography was performed on a Hypersil Gold column (50 mm × 2.1 mm i.d., dp: 1.9 μm, run-time: 10 min) using 0.01% acetic acid in water (A) and acetonitrile (B) as mobile phases.  相似文献   

4.
A rapid method has been developed to analyse morphine, codeine, morphine-3-glucuronide, 6-monoacetylmorphine, cocaine, benzoylegonine, buprenorphine, dihydrocodeine, cocaethylene, 3,4-methylenedioxyamphetamine, ketamine, 3,4-methylenedioxymethamphetamine, pseudoephedrine, lignocaine, benzylpiperazine, methamphetamine, amphetamine, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine and methadone in human urine. Urine samples were diluted with methanol:water (1:1, v/v) and sample aliquots were analysed by hybrid linear ion trap-triple quadrupole mass spectrometry with a runtime of 12.5 min. Multiple reaction monitoring (MRM) as survey scan and an enhanced product ion (EPI) scan as dependent scan were performed in an information-dependent acquisition (IDA) experiment. Finally, drug identification and confirmation was carried out by library search with a developed in-house MS/MS library based on EPI spectra at a collision energy spread of 35 ± 15 in positive mode and MRM ratios. The method was validated in urine, according to the criteria defined in Commission Decision 2002/657/EC. At least two MRM transitions for each substance were monitored in addition to EPI spectra and deuterated analytes were used as internal standards for quantitation. The reporting level was 0.05 μg mL−1 for the range of analytes tested. The regression coefficients (r2) for the calibration curves (0–4 μg mL−1) in the study were ≥0.98. The method proved to be simple and time efficient and was implemented as an analytical strategy for the illicit drug monitoring of opioids, cocaines and amphetamines in criminal samples from crime offenders, abusers or victims in the Republic of Ireland. To the best of our knowledge there are no hybrid LC–MS applications using MRM mode and product ion spectra in the linear ion trap mode for opioids, cocaines or amphetamines with validation data in urine.  相似文献   

5.
ABSTRACT

A fast, selective and sensitive reversed-phased liquid chromatography coupled to ion-trap mass spectrometry has been developed to elucidate and confirm the diazinon metabolites with a wide range of polarity in the rice plant samples. Sample extraction and purification were performed with a QuEChERS-based (Quick, Easy, Cheap, Effective, Rugged, and Safe) procedure. To boost all metabolism sensitivities, all rice extracts were concentrated under vacuum to near dryness and taken up into initial mobile phase. Careful optimisation of the LC–MS/MS parameters were achieved in order to attain a fast separation with the best sensitivity. The detection was carried out on an ion-trap mass spectrometer by electrospray ionisation in positive ion mode (ESI+) with multiple reaction monitoring.  相似文献   

6.
7.
We have developed a method using on-line solid-phase extraction–high-performance liquid chromatography–tandem mass spectrometry (SPE-HPLC-MS/MS) and isotope dilution quantification to measure atrazine and seven atrazine metabolites in urine. The metabolites measured were hydroxyatrazine, diaminochloroatrazine, desisopropylatrazine, desethylatrazine, desethylatrazine mercapturate, atrazine mercaturate and atrazine itself. Our method has good precision (relative standard deviations ranging from 4 to 20% at 5, 10 and 50 ng/mL), extraction efficiencies of 67 to 102% at 5 and 25 ng/mL, relative recoveries of 87 to 112% at 5, 25, 50 and 100 ng/mL limits of detection (LOD) ranging from 0.03 to 2.80 ng/mL. The linear range of our method spans from the analyte LOD to 100 ng/mL (40 ng/mL for atrazine and atrazine mercapturate) with R 2 values of greater than 0.999 and errors about the slope of less than 3%. Our method is rapid, cost-effective and suitable for large-scale sample analyses and is easily adaptable to other biological matrices. More importantly, this method will allow us to better assess human exposure to atrazine-related chemicals. Figure A schematic representation showing the elution of the analytes from the solid-phase extraction cartridge onto the analytical column for chromatographic separation prior to MS/MS analysis  相似文献   

8.
The excretion of neurotransmitter metabolites in normal individuals is of great significance for health monitoring. A rapid quantitative method was developed with ultra-performance liquid chromatography–tandem mass spectrometry. The method was further applied to determine catecholamine metabolites vanilymandelic acid (VMA), methoxy hydroxyphenyl glycol (MHPG), dihydroxy-phenyl acetic acid (DOPAC), and homovanillic acid (HVA) in the urine. The urine was collected from six healthy volunteers (20–22 years old) for 10 consecutive days. It was precolumn derivatized with dansyl chloride. Subsequently, the sample was analyzed using triple quadrupole mass spectrometry with an electrospray ion in positive and multireaction monitoring modes. The method was sensitive and repeatable with the recoveries 92.7–104.30%, limits of detection (LODs) 0.01–0.05 μg/mL, and coefficients no less than 0.9938. The excretion content of four target compounds in random urine samples was 0.20 ± 0.086 μg/mL (MHPG), 1.27 ± 1.24 μg/mL (VMA), 3.29 ± 1.36 μg/mL (HVA), and 1.13 ± 1.07 μg/mL (DOPAC). In the urine, the content of VMA, the metabolite of norepinephrine and adrenaline, was more than MHPG, and the content of HVA, the metabolite of dopamine, was more than DOPAC. This paper detected the levels of catecholamine metabolites and summarized the characteristics of excretion using random urine samples, which could provide valuable information for clinical practice.  相似文献   

9.
Metabolism of four tobacco-specific N-nitrosamines (TSNAs), N′-nitrosonornicotine (NNN), N′-nitrosoanatabine (NAT), N′-nitrosoanabasine (NAB), and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) has been studied by solid-phase extraction (SPE) and liquid chromatography–tandem mass spectrometry (LC–MS–MS). 4-(Methylnitrosamino)-4-(3-pyridyl)-1-butanol (iso-NNAL) was used as internal standard. SPE and LC–MS–MS was found to be a rapid, simple, sensitive, and selective method for analysis of TSNAs in rabbit serum. The relative standard deviation (R.S.D., n = 6) for analysis of 5 ng mL−1 and 0.5 ng mL−1 standards and of serum sample spiked with 5 ng mL−1 standards of five TSNAs was 2.1–11% and recovery of 5 ng mL−1 standards from serum was 100.2–112.9%. A good linear relationship was obtained between peak area ratio and concentration in the range of 0.2–100 ng mL−1 for NNAL and 0.5–100 ng mL−1 for other four TSNAs, with correlation coefficients (R 2) >0.99 (both linear and log–log regression). Detection limits for standards in solvent were between 0.04 and 0.10 ng mL−1. Doses of TSNAs administered to rabbits via the auricular vein were 4.67 μg kg−1 and 11.67 μg kg−1, in accordance with the different levels in cigarettes. Metabolic curves were obtained for the four TSNAs and for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a metabolite of NNK; on the basis of these curves we modeled metabolic kinetic equations for these TSNAs by nonlinear curve fitting.  相似文献   

10.
This paper describes a liquid chromatographic/tandem mass spectrometric (LC/MS–MS) method specifically designed for the screening of synthetic glucocorticosteroids in human urine. The method is designed to recognize a common mass spectral fragment formed from the particular portion of the molecular structure that is common to all synthetic glucocorticosteroids and that is fundamental to their pharmacological activity. As such, the method is also suitable for detecting unknown substances, provided they contain the portion of the molecular structure selected as the analytical target. The effectiveness of this approach was evaluated on seventeen synthetic glucocorticosteroids. Urine samples, including blank urines spiked with one or more synthetic glucocorticosteroids, were treated according to a standard procedure (enzymatic hydrolysis, liquid/liquid extraction and evaporation to dryness) and analyzed using LC/MS-MS with electrospray ionization (ESI). MS–MS acquisition was carried out in a precursor ion scan, and the results were compared with those obtained by a previously developed reference technique based on acquisition in the multiple reaction monitoring (MRM) mode. All of the glucocorticosteroids considered in this study are clearly detectable in urine, with a limit of detection in the concentration range 5–20 ng/mL, depending on the glucocorticosteroid structure. The proposed method is therefore suitable for the detection of glucocorticosteroids in urine samples taken for “in competition” sport anti-doping control tests, matching the requirements of the World Anti-Doping Agency (WADA) for accredited anti-doping laboratories. Figure Structures of the synthetic glucocorticoids considered in this study  相似文献   

11.
The characterization of unknown impurities present in tobramycin by liquid chromatography (LC) coupled with mass spectrometry (MS) is described. A reversed-phase (RP)-LC method using a volatile mobile phase containing a perfluorinated ion-pair reagent was developed and coupled with an ion trap mass spectrometer. The structures of the unknown impurities were deduced by comparison of their fragmentation patterns with those of the available reference substances obtained by LC–MSn experiments.  相似文献   

12.
An ultra performance liquid chromatography–electrospray ionization-tandem mass spectrometry (UPLC–MS/MS) method was developed for the analysis of steroids and their glucuronides in urine samples. The method provides high sensitivity and fast analysis, as both steroids and their glucuronides can be analyzed directly without hydrolysis or complex sample preparation. The method was applied in profiling of targeted and nontargeted steroids and steroid glucuronides during pregnancy. The concentrations of 11 of 27 targeted steroids and steroid glucuronides and the concentrations of 25 nontargeted steroid glucuronides increased about 10–400 fold during the pregnancy. The concentrations of most of these 36 compounds began to increase in the first days of the pregnancy, increased gradually during the pregnancy, achieved a maximum in late pregnancy, and decreased sharply after delivery. Exceptionally, the concentrations of allopregnanolone and 17-hydroxypregnenolone started to increase later than those of the other steroids. Moreover, the concentrations of E2 glucuronides began to decrease one week before the delivery, in contrast to most of the steroids and steroid glucuronides, whose concentrations dropped sharply during the delivery. Concentrations of 34 compounds decreased noticeably when the subject was on sick leave owing a series of painful contractions. The results suggest that steroids and especially steroid glucuronides may provide a valuable diagnostic tool to follow the course of pregnancy.  相似文献   

13.
A simple, fast and high-throughput LC–tandem mass spectrometry method was developed and validated to simultaneously measure liraglutide and insulin degludec in rat plasma. After protein precipitation, plasma samples were subjected to gradient elution using an InertSustain Bio C18 column with 1000/20/1 water/acetonitrile/formic acid (v/v/v) and 1000/1 acetonitrile/formic acid (v/v) as the mobile phase. The method was validated from 1.00 to 500 ng/mL of liraglutide and insulin degludec. Further, the extraction recovery from the plasma was 41.8%–49.2% for liraglutide and 56.5%–69.7% for insulin degludec. Intra- and inter-day precision of liraglutide was 3.5%–9.4% and 8.4%–9.8%, respectively, whereas its accuracy was between −12.6% and −1.3%. Intra- and inter-day precision of insulin degludec was 5.2%–13.6% and 11.8%–19.1%, respectively, showing an accuracy between −3.0% and 9.9%. As a result, the method was successfully applied to a pharmacokinetics study of liraglutide and insulin degludec following a single-dose subcutaneous administration to rats.  相似文献   

14.
Ecgonine is suggested to be a promising marker of cocaine (COC) ingestion. A combined mass spectrometry (MS) and tandem MS (MS/MS) method was developed to simultaneously determine ecgonine and seven other metabolites of cocaine in human urine and whole blood with ultra-high-pressure liquid chromatography coupled with quadrupole time-of-flight mass spectrometry. The compounds were extracted from as little as 100 μL of sample by solid-phase extraction with a 96-well μElution solid-phase extraction plate. The protonated molecules or fragment ions at accurate mass acquired in MS mode were used to quantify specific analytes, following by dedicated MS/MS identification. The assay was linear in the range from 5 to 50-100 ng/mL for urine samples, except for ecgonine methyl ester (10-200 ng/mL) and ecgonine (40-400 ng/mL), and was linear from 1-2 to 50 ng/mL for whole blood samples, except for ecgonine methyl ester (20-1,000 ng/mL) and ecgonine (40-2,000 ng/mL). The correlation coefficients were all greater than 0.99. The limits of detection ranged from 0.2 to 16 ng/mL, and the lower limits of quantification ranged from 1 to 40 ng/mL. The repeatability and intermediate precision were 18.1 % or less. The accuracy was in the range from 80.0 to 122.9 %, process efficiencies were in the range from 8.6 to 177.4 %, matrix effects were in the range from 28.7 to 171.0 %, and extraction recoveries were in the range from 41.0 to 114.3 %, except for ecgonine (12.8 % and 9.3 % at low and high concentrations, respectively). This method was highly sensitive in comparison with previously published methods. The validated method was successfully applied to the analysis of real samples derived from forensic cases, and the results verified that, on the basis of data from four positive samples, ecgonine is a promising marker of cocaine ingestion.
Figure
Procedure for the determination of ecgonine and seven other cocaine metabolites in human urine and whole blood using a combined mass spectrometry and tandem MS method aIer the solid‐phase extraction of the anaytes  相似文献   

15.
16.
A rapid, selective and sensitive ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method was developed to detect meloxicam in human plasma. A triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source was used in positive ion mode. Protein precipitation with acetonitrile was used for sample preparation. Meloxicam and 13C6-meloxicam internal standard were analyzed on an Acquity CSH C18 column with a mobile phase of acetonitrile and water in 0.1% formic acid using a gradient program for separation. The retention time of meloxicam was 1.1 min and the total run time was only 2.0 min. Detection was performed in multiple reaction monitoring mode using an electrospray ionization source with optimized mass spectrometry parameters. The calibration curves were linear in the range 10.0–3.00 × 103 ng/ml (r ≥ 0.99). The within-run and between-run RSDs were ≤14.8%. The within-run and between-run REs ranged from −4.6 to 10.7%. There was no significant matrix effect, and the recovery rate was high. This method was fully validated, including reinjection reproducibility in human plasma. The method was applied to the pharmacokinetic study. All of the incurred sample reanalysis methods met the criteria.  相似文献   

17.
The transfer of a gradient method to an isocratic or multistep gradient method employing stationary phase optimized liquid chromatography facilitated a reduction in analysis time by 50% and significantly improved the mass spectrometric detectability of impurities in synthetic thyroid hormones. Four column segments packed with different stationary phases were combined into a single chromatographic column, which allowed the separation and photometric as well as mass spectrometric detection of thyroid compounds in less than 30 min under isocratic- or step gradient elution conditions with 0.10% acetic acid/acetonitrile. Signal instability and baseline drift during detection by negative electrospray ionization time-of-flight mass spectrometry were minimized by optimizing the spray parameters for each individual elution step. This resulted in improved detectabilities and higher mass spectral quality, especially for low-abundance components in the sample mixture. The method was applied to the separation and detection of the low-abundance impurities formed upon the thermal stressing of a sample of synthetic levothyroxine.  相似文献   

18.
A liquid chromatography–electrospray-tandem mass spectrometry (ES-MS/MS) method was developed for the speciation analysis of four organic selenium species of relevance to human urinary metabolism, namely trimethylselenomium ion (TMSe+), selenomethionine (SeMet) and the two selenosugars, methyl 2-acetamido-2-deoxy-1-seleno-β-d-galactos/-glucos-amine (SeGalNAc and SeGluNAc, respectively). Their chromatographic separation was achieved by using a cation exchange pre-column coupled in-series with a reversed-phase high-performance liquid chromatography column, along with an isocratic mobile phase. Online detection was performed using ES-MS/MS in selective reaction monitoring mode. SeGalNAc was detected as the major human urinary metabolite of selenium in the samples analysed, whereas TMSe+ was detected in the urine of one volunteer before and after receiving a selenium supplement. SeMet was not detected as a urine excretory metabolite in this study. Spiking experiments performed with the urine samples revealed significant signal suppression caused by coeluting matrix constituents. To overcome such interferences, isotopically labelled 13CD382SeGalNAc was used as an internal standard, whereas in the absence of an isotopically labelled internal standard for TMSe+, the standard addition method was applied. Quality control for the accurate quantitation of TMSe+ and SeGalNAc was carried out by analysing spiked human urine samples with appropriate selenium standards over a concentration range of 10–50 μg Se L−1. The method has achieved a limit of detection in the presence of urine matrix comparable to that of HPLC-inductively coupled plasma-mass spectrometry for the four selenium species: 1.0 μg Se L−1 for TMSe+, 5.6 μg Se L−1 for SeMet, and 0.1 μg Se L−1 for both SeGalNAc and SeGluNAc.  相似文献   

19.
20.
The development of nontargeted screening strategy for veterinary drugs and their metabolites is very important for food safety. In this study, a nontargeted screening strategy was developed to find the potentially hazardous substances based on mass defect filtering (MDF) using liquid chromatography–high-resolution mass spectrometry. First, the drug metabolites of 112 veterinary drugs from seven classes of antimicrobials were predicted. Second, three MDF models were established, including the traditional rectangular MDF, the enhanced parallelogram MDF, and the polygonal MDF. Finally, the strategy was applied to nontargeted screening of veterinary drugs in 36 milk samples. The polygonal MDF model based on the distribution area of parent drugs and their metabolites showed a better filtering effect. After removing food components and performing MDF, about 10% of the substances remained, and four veterinary drugs and six drug metabolites were discovered and identified, showing the effectiveness of this strategy. The nontargeted screening strategy can rapidly remove interfering substances and find the suspected compounds. It can also be used for nontargeted screening of veterinary drugs and their metabolites in other food matrices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号