1.
High-performance liquid chromatography (HPLC) combined with inductively coupled plasma mass spectrometry (ICPMS) has been studied as a means for the detection of carbon to provide a 'universal' method for detecting organic compounds in chromatographic eluents. Carbon is particularly difficult to ionise and the amount of carbon present in normal chromatographic systems leads to high backgrounds, making detection a challenge. Novel separation approaches were therefore employed, using either entirely aqueous eluents (at temperatures of 60 and 160 degrees C, dependent on the column used) to eliminate the organic modifier completely, or isotopically enriched solvents. For the aqueous eluents, detection limits for sulphanilamide were found to be 2.26 microg, corresponding to 1.13 micromol (0.47 micromol of carbon), injected on a conventional 4.6 mm i.d. column. The use of a narrow bore column with highly isotopically enriched 12C-methanol (99.95 atom%) as organic modifier for the mobile phase enabled the detection of 86 micromol for 13C-triple-labelled caffeine and 79 micromol for 13C-double-labelled phenacetin. The sensitive detection of 12C-compounds with 13C-enriched methanol as organic modifier proved impractical due to a lower level of isotopic enrichment (99 atom%) of this solvent, with the residual 12C-methanol resulting in significant interference.  相似文献   

2.
Ultra-performance liquid chromatography (UPLC) utilizes sub-2 microm particles with high linear solvent velocities to effect dramatic increases in resolution, sensitivity and speed of analysis. The reduction in particle size to below 2 microm requires instrumentation that can operate at pressures in the 6000-15,000 psi range. The typical peak widths generated by the UPLC system are in the order of 1-2 s for a 10-min separation. In the present work this technology has been applied to the study of in vivo drug metabolism, in particular the analysis of drug metabolites in bile. The reduction in peak width significantly increases analytical sensitivity by three- to five-fold, and the reduction in peak width, and concomitant increase in peak capacity, significantly reduces spectral overlap resulting in superior spectral quality in both MS and MS/MS modes. The application of UPLC/MS resulted in the detection of additional drug metabolites, superior separation and improved spectral quality.  相似文献   

3.
Compound‐specific isotope analysis (CSIA) by liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) has until now been based on ion‐exchange separation. In this work, high‐temperature reversed‐phase liquid chromatography was coupled to, and for the first time carefully evaluated for, isotope ratio mass spectrometry (HT‐LC/IRMS) with four different stationary phases. Under isothermal and temperature gradient conditions, the column bleed of XBridge C18 (up to 180 °C), Acquity C18 (up to 200 °C), Triart C18 (up to 150 °C), and Zirchrom PBD (up to 150 °C) had no influence on the precision and accuracy of δ13C measurements, demonstrating the suitability of these columns for HT‐LC/IRMS analysis. Increasing the temperature during the LC/IRMS analysis of caffeine on two C18 columns was observed to result in shortened analysis time. The detection limit of HT‐RPLC/IRMS obtained for caffeine was 30 mg L–1 (corresponding to 12.4 nmol carbon on‐column). Temperature‐programmed LC/IRMS (i) accomplished complete separation of a mixture of caffeine derivatives and a mixture of phenols and (ii) did not affect the precision and accuracy of δ13C measurements compared with flow injection analysis without a column. With temperature‐programmed LC/IRMS, some compounds that coelute at room temperature could be baseline resolved and analyzed for their individual δ13C values, leading to an important extension of the application range of CSIA. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
High-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) has been used to search for the formation of as yet unidentified radiation-induced DNA lesions. For that purpose, the characteristic fragmentation of most of 2'-deoxyribonucleosides that corresponds to the loss of the 2-deoxyribose moiety (loss of 116 mass units) has been utilized to specifically detect modified nucleosides. Aerated aqueous solutions of DNA were exposed to ionizing radiation, and subsequently DNA was digested to nucleosides with a cocktail of endo- and exonucleases. HPLC/ESI-MS/MS analysis of the resulting 2'-deoxyribonucleoside mixture allowed us to detect four novel DNA modifications. In a subsequent step, the sensitivity of the tandem mass spectrometer was used to search for the formation of the newly detected lesions in the DNA of gamma-irradiated cells. Thus, one of the four newly detected lesions was found to be significantly generated in cellular DNA upon exposure to ionizing radiation. In addition, the latter lesion was also shown to be present in untreated cells, indicating that the modified nucleoside could be formed endogenously.  相似文献   

5.
In this review, instrumental aspects of comprehensive two-dimensional liquid chromatography coupled with mass spectrometry are presented. The milestones of LC×LC are briefly summarized. Instrument configuration, selection of experimental conditions, the different interfaces used in the system and the current applications of LC×LC–MS systems are described.  相似文献   

6.
The quantitative and confirmative performance of two different mass spectrometry (MS) techniques (high-resolution MS and tandem MS) was critically compared. Evaluated was a new extraction and clean-up protocol which was developed to cover more than 100 different veterinary drugs at trace levels in a number of animal tissues and honey matrices. Both detection techniques, high-resolution mass spectrometry (HRMS) (single-stage Orbitrap instrument operated at 50 000 full width at half maximum) and tandem mass spectrometry (MS/MS) (quadrupole technology) were used to validate the method according to the EU Commission Decision 2002/657/EEC. Equal or even a slightly better quantitative performance was observed for the HRMS-based approach. Sensitivity is higher for unit mass resolution MS/MS if only a subset of the 100 compounds has to be monitored. Confirmation of suspected positive findings can be done by evaluating the intensity ratio between different MS/MS transitions, or by accurate mass based product ion traces (no precursor selection applied). MS/MS relies on compound-specific optimized transitions; hence the second, confirmatory transition generally shows relatively high ion abundance (fragmentation efficacy). This is often not the case in single-stage HRMS, since a generic (not compound-optimized) collision energy is applied. Hence, confirmation of analytes present at low levels is superior when performed by MS/MS. Slightly better precision, but poorer accuracy (fortified matrix extracts versus pure standard solution) of ion ratios were observed when comparing data obtained by HRMS versus MS/MS.  相似文献   

7.
We present an overview of current analytical methods for selected halogenated flame retardants (HFRs), focusing on instrumental determination using liquid chromatography coupled to mass spectrometry. We based the strategy for literature search on recent articles published in peer-reviewed scientific journals or conference proceedings. We report on selected HFRs and some metabolites and transformation products, and on the analytical performances of different ionization modes, with emphasis on selectivity and sensitivity. Moreover, we compare these parameters with those obtained by gas chromatography.  相似文献   

8.
Two new procedures for wine ethanol 13C/12C isotope ratio determination, using high-performance liquid chromatography and gas chromatography isotope ratio mass spectrometry (HPLC/IRMS and GC/IRMS), have been developed to improve isotopic methods dedicated to the study of wine authenticity. Parameters influencing separation of ethanol from wine matrix such as column, temperature, mobile phase, flow rates and injection mode were investigated. Twenty-three wine samples from various origins were analyzed for validation of the procedures. The analytical precision was better than 0.15 per thousand, and no significant isotopic fractionation was observed employing both separative techniques coupled to IRMS. No significant differences and a very strong correlation (r = 0.99) were observed between the 13C/12C ratios obtained by the official method (elemental analyzer/isotope ratio mass spectrometry) and the proposed new methodology. The potential advantages of the developed methods over the traditional one are speed (reducing time required from hours to minutes) and simplicity. In addition, these are the first isotopic methods that allow 13C/12C determination directly from a liquid sample with no previous ethanol isolation, overcoming technical difficulties associated with sample treatment.  相似文献   

9.
Supercritical fluid chromatography (SFC) has experienced a particular revival in recent years thanks to the development of robust and efficient commercial systems. Because of its physico‐chemical properties, supercritical carbon dioxide (CO2) mixed with cosolvents and additives is particularly suitable for SFC to allow the elution of compounds of different polarities and more particularly complex lipids. Hyphenation with mass spectrometry (MS) is increasingly described in the literature but still requires many further developments in order to be as user‐friendly as coupling with liquid chromatography. The basic concepts of SFC and MS hyphenation will be first considered. Then a representative example of method development in lipidomics will be introduced. In conclusion, the challenges and future needs in this field of research will be discussed.  相似文献   

10.
A procedure involving capillary column gas chromatography coupled to mass spectrometry and a method involving liquid chromatography coupled to a diode-array detector have been developed for the analysis of nalbuphine. The extraction step is the same for both techniques and involves extraction under alkaline conditions in chloroform-2-propanol-n-heptane (50:17:33, v/v/v) with levallorphan as the internal standard. After purification by acidic extraction and back alkaline extraction, drugs are derivatized with N,O-bis-(trimethylsilyl)trifluoroacetamide with 1% trimethylchlorosilane for gas chromatography-mass spectrometry and directly injected for high-performance liquid chromatography-diode-array detection. The limits of detection are 2.0 and 25.0 ng/mg, respectively.  相似文献   

11.
Zhao C  Wu Z  Xue G  Wang J  Zhao Y  Xu Z  Lin D  Herbert G  Chang Y  Cai K  Xu G 《Journal of chromatography. A》2011,1218(23):3669-3674
Nanoflow liquid chromatography/mass spectrometry (nano-LC/MS) has attracted increasing interest in virtue of high sensitivity, low sample consumption, and minimal matrix effect. In this work a HPLC-Chip/quadrupole time-of-flight (Q-TOF) MS device with a new ultra-high capacity small molecule chip (UHC-Chip) which features a 500 nL enrichment column and a 150 mm × 75 μm analytical column, was evaluated with a drug mixture covering a wide range of polarities. Excellent chromatographic precision with 0.1-0.5% RSD for retention time and 1.7-9.0% RSD for peak area, low limit of detection, good chip-to-chip reproducibility and linearity were obtained by using this UHC-Chip. Compared with the standard HPLC-Chip with 40 nL trapping column, the UHC-Chip showed higher enrichment capability and hence gave a higher response in signal detection. Additionally, 4-30 times increase in sensitivity was obtained compared with conventional LC/MS, which indicated that UHC-Chip/MS was a valuable tool for the quantitative analysis of low level impurities and degradation products in pharmaceuticals. Moreover, satisfactory results obtained from trace drug analysis of serum samples further proved its practicality and potential for use in drug testing and development.  相似文献   

12.
Under most physiological conditions, glucose, or carbohydrate (CHO), homeostasis is tightly regulated. In order to mechanistically appraise the origin of circulating glucose (e.g. via either gluconeogenesis, glycogenolysis or oral glucose intake), and its regulation and oxidation, the use of stable isotope tracers is now a well-accepted analytical technique. Methodologically, liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) can replace gas chromatography coupled to combustion-isotope ratio mass spectrometry (GC/C/IRMS) for carrying out compound-specific (13)C isotopic analysis. The LC/IRMS approach is well suited for studying glucose metabolism, since the plasma glucose concentration is relatively high and the glucose can readily undergo chromatography in an aqueous mobile phase. Herewith, we report two main methodological approaches in a single instrument: (1) the ability to measure the isotopic enrichment of plasma glucose to assess the efficacy of CHO-based treatment (cocoa-enriched) during cycling exercise with healthy subjects, and (2) the capacity to carry out bulk isotopic analysis of labeled solutions, which is generally performed with an elemental analyzer coupled to IRMS. For plasma samples measured by LC/IRMS the data show a isotopic precision SD(δ(13)C) and SD(APE) of 0.7 ‰ and 0.001, respectively, with δ(13)C and APE values of -25.48 ‰ and 0.06, respectively, being generated before and after tracer administration. For bulk isotopic measurements, the data show that the presence of organic compounds in the blank slightly affects the δ(13)C values. Despite some analytical limitations, we clearly demonstrate the usefulness of the LC/IRMS especially when (13)C-glucose is required during whole-body human nutritional studies.  相似文献   

13.
Quantification of unknown components in pharmaceutical, metabolic and environmental samples is an important but difficult task. Most commonly used detectors (like UV, RI or MS) require standards of each analyte for accurate quantification. Even if the chemical structure or elemental composition is known, the response from these detectors is difficult to predict with any accuracy. In inductively coupled plasma mass spectrometry (ICP-MS) compounds are atomised and ionised irrespective of the chemical structure(s) incorporating the element of interest. Liquid chromatography coupled with inductively coupled plasma mass spectrometry (LC/ICP-MS) has been shown to provide a generic detection for structurally non-correlated compounds with common elements like phosphorus and iodine. Detection of selected elements gives a better quantification of tested 'unknowns' than UV and organic mass spectrometric detection. It was shown that the ultrasonic nebuliser did not introduce any measurable dead volume and preserves the separation efficiency of the system. ICP-MS can be used in combination with many different mobile phases ranging from 0-100% organic modifier. The dynamic range was found to exceed 2.5 orders of magnitude. The application of LC/ICP-MS to pharmaceutical drugs and formulations has shown that impurities can be quantified below the 0.1 mol-% level.  相似文献   

14.
Metabonomics, the study of metabolites and their roles in various disease states, is a novel methodology arising from the post-genomics era. This methodology has been applied in many fields. Current metabonomic practice has relied on mass spectrometry (MS), gas chromatography-mass spectrometry (GC-MS), and nuclear magnetic resonance (NMR) to analyze metabolites. In this study, a strategy was developed for applying high-performance liquid chromatography (HPLC) and LC-MS-MS to metabonomics research. One of the key problems to be solved in this strategy is to match the peaks between the chromatograms. A peak alignment algorithm has been developed to match the chromatograms before the pattern recognition. As an application example, the strategy described above was applied to metabonomics research on liver diseases, and the false-positive result of live cancer diagnosis from the hepatocirrhosis and hepatitis diseases was effectively reduced to 7.40%. Based on the pattern recognition, several potential biomarkers were found and further identified by the following LC-MS-MS experiments. The structures of eight potential biomarkers were given for distinguishing the liver cancer from the hepatocirrhosis and hepatitis diseases.  相似文献   

15.
A novel LC-MS/MS method has been developed for the determination of 13 aminoglycoside antibiotics in meat products. Among the chromatographic columns tested, the mixed-mode Obelisc R provided the best performance. Electrospray has been used for the coupling of the LC and the effect of temperature on the ionization has been evaluated. The mass spectra of AGs have been studied in order to select the most adequate precursor and product ions for quantitation and confirmation in SRM mode, showing that the single charged [M+H]+ provided better precisions than the double charged [M+2H]2+. Accurate mass measurements have been performed in order to confirm the molecular composition of the product ions, allowing the establishment of a new mechanism for some product ions of STR and DHSTR. A sample treatment based on an extraction and a SPE clean-up has been applied to a wide variety of meat products such as frankfurters; sausages; and minced meat of pork, veal, and chicken. Method limits of quantitation in the low microgram per kilogram level (1–50 μg kg?1), precisions %RSD below 15 % and accuracies expressed as relative errors below 23 % have been obtained, making the proposed method suitable for routine analysis.  相似文献   

16.
Flavonoids are a class of secondary plant metabolites existing in great variety in nature. Due to this variety, identification can be difficult, especially as overlapping compounds in both chromatographic separations and mass spectrometric detection are common. Methods for distinguishing isobaric flavonoids using MS2 and MS3 have been developed. Chromatographic separation of various plant extracts was done with RP‐HPLC and detected with positive ESI‐MS operated in information‐dependent acquisition (IDA) mode. Two methods for the determination of flavonoid identity and substitution pattern, both featuring IDA criteria, were used together with the HPLC equipment. A third method where the collision energy was ramped utilized direct infusion. With the developed strategies, it is possible to differentiate between many isobaric flavonoids. Various classes of flavonoids were found in all of the plant extracts, in the red onion extract 45 components were detected and for 29 of them the aglycone was characterized, while the substituents were tentatively identified for 31 of them. For the strawberry extract, those numbers were 66, 30 and 60, and for the cherry extract 99, 56 and 71. The great variety of flavonoids, several of them isobaric, found in each of the extracts highlights the need for reliable methods for flavonoid characterization. Methods capable of differentiating between most of the isobars analyzed have been developed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
Y Chang  C Zhao  Z Wu  J Zhou  S Zhao  X Lu  G Xu 《Electrophoresis》2012,33(15):2399-2406
In this work a chip-based nano HPLC coupled MS (HPLC-chip/MS) method with a simple sample preparation procedure was developed for the flavonoid profiling of soybean. The analytical properties of the method including the linearity (R(2) , 0.992-0.995), reproducibility (RSD, 1.50-7.66%), intraday precision (RSD, 1.41-5.14%) and interday precision (RSD, 2.76-16.90%) were satisfactory. Compared with the conventional HPLC/MS method, a fast extraction and analysis procedure was applied and more flavonoids were detected in a single run. Additionally, 13 flavonoids in soybean seed were identified for the first time. The method was then applied to the profiling of six varieties of soybean sowed at the same place. A clear discrimination was observed among different cultivars, three isoflavones, accounting for nearly 80% of total flavonoid contents, were found increased in the spring soybeans compared with the summer cultivars.  相似文献   

18.
Using a parallel microcolumn switching liquid chromatography set-up coupled to a quadrupole time-of-flight mass spectrometer, a rapid liquid chromatography/mass spectrometric (LC/MS) protein identification method is presented. Without prior sample clean-up up to 300 protein digest samples a day can be processed. Using data-directed acquisition, up to 10 fragmentation analyses for each protein sample can be acquired in the same chromatographic run that can be used for database searching. Using internal peptide sequence information, protein databases and the various nucleic acid databases can both be queried for cross-species identification of the protein sample. The method was evaluated and put into force to generate data for a tobacco cell culture protein database.  相似文献   

19.
There is growing interest related to rapid screening and full characterization of the constituents of plants with medicinal properties; among these, “Mate” or Yerba Maté is a tea-like beverage widely consumed in South America, obtained from the dried leaves of Ilex paraguariensis. The high content in polyphenols accounts for in vitro and in vivo antioxidant activity of the extracts obtained from this plant; on the other hand, the high complexity of the samples extracted, depending on the method employed, may preclude complete resolution by conventional HPLC techniques. For this purpose, a comprehensive two-dimensional liquid chromatography (LC × LC) system, comprised of an RP-Amide first dimension and a partially porous octadecylsilica column in the second dimension, has been compared with a one-dimensional system. The latter was operated using a partially porous octadecylsilica column, with diode array (DAD) and electrospray/ion trap-time of flight (ESI/IT-TOF) detection for the most complex extracts. The employment of the hybrid mass spectrometer allowed unequivocal identification of several compounds in the mate extracts. Using LC × LC–MS3, it was possible to discriminate between congeners of chlorogenic acids, along with monoacyl- and diacylchlorogenic acid esters.  相似文献   

20.
Inductively coupled plasma mass spectrometry (ICP/MS) is utilized as a detector for several organotin species separated by high-performance liquid chromatography. Detection limits obtained by ICP/MS are 3 orders of magnitude lower than those obtained with inductively coupled plasma atomic emission spectrometry (ICP/AES) detection under the same chromatographic conditions. Chromatographic detection limits are higher than conventional solution nebulization for the same compound by a factor of 20. Ion-exchange chromatography yields linear response over 3 orders of magnitude, while ion pair chromatography gives a linear response of only 2 orders of magnitude as a result of poor resolution. The relative standard deviation for the injection of 20 ng of tin compounds is less than 10%.  相似文献   