首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cense B  Chen TC  Park BH  Pierce MC  de Boer JF 《Optics letters》2002,27(18):1610-1612
To our knowledge, this is the first demonstration of in vivo depth-resolved birefringence measurements of the human retinal nerve fiber layer (RNFL) by use of polarization-sensitive optical coherence tomography (PS-OCT). Because glaucoma causes nerve fiber layer damage, which may cause loss of retinal birefringence, PS-OCT is a potentially useful technique for the early detection of glaucoma. We built a fiber-based PS-OCT setup that produces quasi-real-time images of the human retina in vivo . Preliminary measurements of a healthy volunteer showed that the double-pass phase retardation per unit depth of the RNFL near the optic nerve head is 39+/-6( degrees )/100microm .  相似文献   

2.
Jiao S  Wang LV 《Optics letters》2002,27(2):101-103
A double-beam polarization-sensitive system based on optical coherence tomography was built to measure the Mueller matrix of scattering biological tissue with high spatial resolution. The Jones matrix of a sample can be determined with a single scan and subsequently converted into an equivalent nondepolarizing Mueller matrix. As a result, the system can be used to measure the Mueller matrix of an unstable sample, such as soft tissue. The polarization parameters of a porcine tendon, including magnitude and orientation of birefringence and diattenuation, were extracted by decomposition of the measured Mueller matrix.  相似文献   

3.
Hillman EM  Boas DA  Dale AM  Dunn AK 《Optics letters》2004,29(14):1650-1652
Laminar optical tomography (LOT) is a new technique that combines the advantages of diffuse optical tomography image reconstruction and a microscopy-based setup to allow noncontact imaging with 100-200-microm resolution effective over depths of 0-2.5 mm. LOT is being developed primarily for multispectral imaging of rat cortex, for which resolving functional dynamics in various layers of the brain's cortex (to depths of 1500 microm) is of increasing interest to neurophysiologists. System design and image reconstruction techniques are described, along with simulation and phantom results that demonstrate the characteristics and limitations of system accuracy and resolution.  相似文献   

4.
Noisy structure of optical coherence tomography (OCT) images of turbid medium contains information about spatial variations of its optical parameters. We propose analytical model of statistical characteristics of OCT signal fluctuations from turbid medium with spatially inhomogeneous coefficients of absorption and backscattering. Analytically predicted correlation characteristics of OCT signal from spatially inhomogeneous medium are in good agreement with the results of correlation analysis of OCT images of different biological tissues. The proposed model can be efficiently applied for quantitative evaluation of statistical properties of absorption and backscattering fluctuations basing on correlation characteristics of OCT images.  相似文献   

5.
Chou C  Peng LC  Chou YH  Tang YH  Han CY  Lyu CW 《Optics letters》2000,25(20):1517-1519
A method that uses a Zeeman laser in conjunction with a Glan-Thompson analyzer to image an object in a turbid medium is proposed. A heterodyne signal is generated only when the scattering photons are partially polarized, and the spatial coherence is not seriously degraded after the signal propagates in the turbid medium. A system combining polarization discrimination with optical coherence detection to image the object in a scattering medium is successfully demonstrated. The medium is a solution of polystyrene microspheres measuring 1.072 mum in diameter suspended in distilled water contained in a 10-mm-thick quartz cuvette. The advantages of this optical system, including better selectivity of the weak partially polarized scattering photons and better imaging ability in higher-scattering media, are discussed.  相似文献   

6.
Optical tomography of turbid media has so far been limited by systems that require fixed geometries or measurements employing fibers. We present a system that records noncontact optical measurements from diffuse media of arbitrary shapes and retrieves the three-dimensional surface information of the diffuse medium. We further present a novel method of combining this composite data set and obtain accurate fluorescence reconstructions. This approach offers significant experimental simplicity and yields high-information-content datasets. The performance of this novel tomographic approach is demonstrated with experimental reconstructions of phantoms.  相似文献   

7.
Using a low-coherence Michelson interferometer, we measure two-dimensional images of optical birefringence in bovine tendon as a function of depth. Polarization-sensitive detection of the signal formed by interference of backscattered light from the sample and a mirror in the reference arm give the optical phase delay between light that is propagating along the fast and slow axes of the birefringent tendon. Images showing the change in birefringence in response to laser irradiation are presented. The technique permits rapid noncontact investigation of tissue structural properties through two-dimensional imaging of birefringence.  相似文献   

8.
Yao G  Wang LV 《Optics letters》1999,24(8):537-539
We built a polarization-sensitive optical coherence tomographic system and measured the two-dimensional depth-resolved full 4 x 4 Mueller matrix of biological tissue for what is believed to be the first time. The Mueller matrix measurements, which we made by varying the polarization states of the light source and the detector, yielded a complete characterization of the polarization property of the tissue sample. The initial experimental results indicated that this new approach reveals some tissue structures that are not perceptible in standard optical coherence tomography.  相似文献   

9.
Differential phase-contrast optical coherence tomography allows one to measure the path-length differences of two transversally separated beams in the nanometer range. We calculate these path-length differences from the phase functions of the interferometric signals. Pure phase objects consisting of chromium layers containing steps of approximately 100-200-nm height were imaged. Phase differences can be measured with a precision of +/-2 degrees , corresponding to a path-difference resolution of 2-3 nm. To investigate the influence of scattering, we imaged the phase objects through scattering layers with increasing scattering coefficients. The limit of phase imaging through these layers was at approximately 8-9 mean free path lengths thick (single pass).  相似文献   

10.
Yasuno Y  Makita S  Sutoh Y  Itoh M  Yatagai T 《Optics letters》2002,27(20):1803-1805
We have developed a spectral interferometric optical coherence tomography (OCT) system with polarization sensitivity that is able to measure a two-dimensional tomographic image by means of one-dimensional mechanical scanning. Our system, which has an axial resolution of 32 mum , calculates the distribution of each element of the Müller matrix of a measured object from 16 OCT images. The OCT system successfully reveals the birefringent nature of human skin tissue.  相似文献   

11.
We introduce a new Monte Carlo (MC) method for simulating optical coherence tomography (OCT) images of complex multilayered turbid scattering media. We demonstrate, for the first time of our knowledge, the use of a MC technique to imitate two-dimensional polarization-sensitive OCT images with nonplanar boundaries of layers in the medium like a human skin. The simulation of polarized low-coherent optical radiation is based on the vector approach generalized from the iterative procedure of the solution of Bethe-Saltpeter equation. The performances of the developed method are demonstrated both for conventional and polarization-sensitive OCT modalities.  相似文献   

12.
Saxer CE  de Boer JF  Park BH  Zhao Y  Chen Z  Nelson JS 《Optics letters》2000,25(18):1355-1357
A high-speed single-mode fiber-based polarization-sensitive optical coherence tomography (PS OCT) system was developed. With a polarization modulator, Stokes parameters of reflected flight for four input polarization states are measured as a function of depth. A phase modulator in the reference arm of a Michelson interferometer permits independent control of the axial scan rate and carrier frequency. In vivo PS OCT images of human skin are presented, showing subsurface structures that are not discernible in conventional OCT images. A phase retardation image in tissue is calculated based on the reflected Stokes parameters of the four input polarization states.  相似文献   

13.
In this work we present a method for determining the optical parameters of turbid media, namely its absorption coefficient (μa) and its reduced scattering coefficient . It is based on the measurement of CW transmittance profiles and analysis of the experimental data by a theoretical model based on the diffusion approximation (DA) of the radiative transfer equation (RTE). The method developed has been investigated with solid polymer probes but it could be applied for liquid materials as well. Experimental results are presented and compared to those of other authors together with a discussion about the accuracy of measurements. In addition, measurements using integrating spheres as well as Monte Carlo simulations are also presented to validate these results.  相似文献   

14.
The possibilities of determining the scattering coefficient, the absorption coefficient, and the scattering anisotropy parameter of strongly scattering media are analyzed on the basis of comparison of experimentally obtained profiles of backscattered radiation with the profiles calculated with help of the numerical Monte Carlo method.  相似文献   

15.
Zhao Y  Chen Z  Ding Z  Ren H  Nelson JS 《Optics letters》2002,27(2):98-100
We have developed a novel real-time phase-resolved functional optical coherence tomography system that uses optical Hilbert transformation. When we use a resonant scanner in the reference arm of the interferometer, with an axial scanning speed of 4 kHz, the frame rate of both structural and Doppler blood-flow imaging with a size of 100 by 100 pixels is 10 Hz. The system has high sensitivity and a larger dynamic range for measuring the Doppler frequency shift that is due to moving red blood cells. Real-time images of in vivo blood flow in human skin obtained with this interferometer are presented.  相似文献   

16.
对基于漫射理论并应用CCD相机测量混沌介质的光学常数进行了实验研究.提出采用漫射中心环带约束法来提高逆向求解光学常数的精确性,以及采用在通过光的入射点和漫射中心的直线上截取一维原始数据的方法来提高算法的计算效率.以Intralipid脂肪乳剂作为混沌介质,对方法进行了实验验证.结果表明,本文提出的方法是可行的.  相似文献   

17.
An improved polarization-sensitive optical coherence tomography (OCT) system is developed and used to measure birefringence in porcine myocardium tissue and produce two-dimensional birefringence mapping of the tissue. Signal-to-noise issues that cause systematic measurement errors are analyzed to determine the regime in which such measurements are accurate. The advantage of polarization-sensitive OCT systems over standard OCT systems in avoiding image artifacts caused by birefringence is also demonstrated.  相似文献   

18.
Color Doppler optical coherence tomography (CDOCT) is capable of precise velocity mapping in turbid media. Previous CDOCT systems based on the short-time Fourier transform have been limited to maximum flow velocities of the order of tens of millimeters per second. We describe a technique, based on interference signal demodulation at multiple frequencies, to extend the physiological relevance of CDOCT by increasing the dynamic range of measurable velocities to hundreds of millimeters per second. The physiologically important parameter of shear rate is also derived from CDOCT measurements. The measured flow-velocity profiles and shear-rate distributions correlate very well with theoretical predictions. The multiple demodulation technique, therefore, may be useful to monitor blood flow in vivo and to identify regions with high and low shear rates.  相似文献   

19.
We describe a novel technique for contrast enhancement in optical coherence tomography (OCT) that makes possible molecular-specific imaging for what is believed to be the first time. A pump-probe technique is employed in which a pulsed pump laser is tuned to ground-state absorption in a molecule of interest. The location of the target molecule population is derived from the resulting transient absorption of OCT sample-arm light acting as probe light. A signal processing technique for three-dimensional localization of the transient absorption signal is described, and preliminary results exhibiting OCT contrast from methylene blue dye in multilayer and scattering phantoms are presented.  相似文献   

20.
Optical coherence tomography (OCT) relies on interference between a polarized reference and the target reflection. Thus, it has generally been impossible to detect any unpolarized part in the signal. Here, we demonstrate a scheme that overcomes this limitation. Using a combination of heterodyning and filtering, we realize a polarization-sensitive OCT system capable of measuring the full Stokes vector, including the depolarized part. Based on such a system, we perform full Stokesmetric imaging of different layers in a porcine tendon sample. The complete 4 × 4 backscattering Muellermetric images of one layer are acquired and investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号