首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Herein, a poly(L-tryptophan) modified glassy carbon electrode (Ptry/GCE) for the determination of maltol is fabricated by electrochemical polymerisation. The electrochemical behaviour of maltol at the Ptry/GCE is studied by cyclic voltammetry (CV). The modified electrode shows excellent electrocatalytic activity towards the oxidation of maltol and the oxidation is a one-proton-one-electron process. In pH 8.0 phosphate buffer solution (PBS), the oxidation peak current of maltol shows a linear relationship with its concentration in the range from 9.00 × 10?5 to 3.75 × 10?3 mol L?1 with a correlation coefficient of 0.9972. The limit of detection is estimated to be 8.00 × 10?6 mol L?1. The novel method shows good selectivity, recovery, reproducibility and great convenience and has been satisfactorily demonstrated in real food sample analysis.  相似文献   

3.
Di J  Bi S  Zhang F 《Talanta》2004,63(2):265-272
The electrochemical behavior of maltol on a glassy carbon (GC) electrode was investigated. The results were applied to differential pulse voltammetric determination of maltol in beverages pretreated by ultrafiltration. Under the optimum experimental conditions, the linear range is 1×10−5 to 6×10−4 mol l−1 maltol and the relative standard deviation for 0.4 mmol l−1 maltol is 0.6% (n=9). The detection limit was 5 μmol l−1. Furthermore, silica sol-gel film on GC electrode could be used as suitable selective membrane, which integrated selective membrane on the electrode and substituted for the pretreatment of ultrafiltration. Under the above conditions, maltol was determined by semi-differential linear sweep voltammetry at a silica sol-gel modified GC electrode in the concentration range of 5×10−6 to 5×10−4 mol l−1. The detection limit was 2 μmol l−1 and the relative standard deviation for 0.1 mmol l−1 maltol was 0.7% (n=7). The proposed method is of sensitivity, simplicity, rapidness and no contamination. It had been applied to the direct determination of maltol in beverages such as grape wines, drinks and beers without any pretreatment. The results obtained with the present method were satisfactory with those obtained by spectrophotometry. It could be used as a simple and practical method for the determination of the flavor enhancer maltol in beverages.  相似文献   

4.
A novel modified electrode was fabricated by electropolymerization of acid chrome blue K at a multi-walled carbon nanotubes modified glassy carbon electrode. The electrode developed was used for simultaneous determination of the isomers of dihydroxybenzene in environmental samples using first order linear sweep derivative voltammetry with background subtraction. A linear relationship between peak current and concentration of hydroquinone, catechol and resorcinol was obtained in the range of 1 × 10−6–1 × 10−4 mol L−1, and the detection limits were estimated to be 1 × 10−7, 1 × 10−7 and 9 × 10−8 mol L−1, respectively. The constructed electrode showed excellent reproducibility and stability. Real water samples were analyzed and satisfactory results were obtained. This method provides a new way of constructing electrodes for environmental and biological analysis.  相似文献   

5.
A novel glassy carbon electrode (GCE) modified with a composite film of poly (4-vinylpyridine) (P4VP) and multiwalled carbon nanotubes (P4VP/MWCNT GCE) was used for the voltammetric determination of paracetamol (PCT). This novel electrode displayed a combined effect of P4VP and MWCNT on the electro-oxidation of PCT in a solution of phosphate buffer at pH 7. Hence, conducting properties of P4VP along with the remarkable physical properties of MWCNTs might have combined effects in enhancing the kinetics of PCT oxidation. The P4VP/MWCNT GCE has also demonstrated excellent electrochemical activity toward PCT oxidation compared to that with bare GCE and MWCNT GCE. The anodic peak currents of PCT on the P4VP/MWCNT GCE were about 300 fold higher than that of the non-modified electrodes. By applying differential pulse voltammetry technique under optimized experimental conditions, a good linear ratio of oxidation peak currents and concentrations of PCT over the range of 0.02–450 μM with a limit of detection of 1.69 nM were achieved. This novel electrode was stable for more than 60 days and reproducible responses were obtained at 99% of the initial current of PCT without any influence of physiologically common interferences such as ascorbic acid and uric acid. The application of this electrode to determine PCT in tablets and urine samples was proposed.  相似文献   

6.
利用循环伏安法将次甲基蓝修饰到玻碳电极表面,制备了聚次甲蓝修饰电极(PMB/GCE),并研究了此电极的化学性质及对叶酸的电化学响应特性.在磷酸盐缓冲液中PMB/GCE电极对叶酸有良好的催化作用并出现一个灵敏的还原峰,用循环伏安法测得峰电流与叶酸的浓度在0.1×10-3~2.9×10 -3 mol/L范围内呈良好线性关系...  相似文献   

7.
Simultaneous determination of catechol (CC) and hydroquinone (HQ) were investigated by voltammetry based on glassy carbon electrode (GCE) modified by poly (diallyldimethylammonium chloride) (PDDA) functionalized graphene (PDDA-G). The modified electrode showed excellent sensitivity and selectivity properties for the two dihydroxybenzene isomers. In 0.1 mol/L phosphate buffer solution (PBS, pH 7.0), the oxidation peak potential difference between CC and HQ was 108 mV, and the peaks on the PDDA-G/GCE were three times as high as the ones on graphene-modified glass carbon electrode. Under optimized conditions, the PDDA-G/GCE showed wide linear behaviors in the range of 1 × 10−6−4 × 10−4 mol/L for CC and 1 × 10−6−5 × 10−4 mol/L for HQ, with the detection limits 2.0 × 10−7 mol/L for CC and 2.5 × 10−7 mol/L for HQ (S/N = 3) in mixture, respectively. Some kinetic parameters, such as the electron transfer number (n), charge transfer coefficient (α), and the apparent heterogeneous electron transfer rate constant (k s), were calculated. The proposed method was applied to simultaneous determine CC and HQ in real water samples of Yellow River with satisfactory results.  相似文献   

8.
We report on an anodic stripping voltammetric method for the determination of tin using a glassy carbon electrode modified with bismuth and poly(bromophenol blue). After an accumulation time of 60?s at ?1.20?V (vs. SCE), the response of the electrode to tin in 1.0?M HCl is linear in the concentration ranges from 20 nM to 1.0?μM, and from 1.0?μM to 20?μM, with a detection limit of 7.0 nM (at an SNR of 3) and with relative standard deviations in the order of 3.0–3.8%. The method was validated by comparing the results with those obtained by AAS and successfully applied to the determination of tin in canned food.
Figure
Differential pulse stripping voltammetric responses of Sn2+ at Bi/Poly(BPB)/GCE in 1.0 M HCl . Sn2+ concentration (μM): 0.020, 0.10, 0.30, 0.50, 0.70, 1.0, 3.0, 5.0, 7.0, 10.0 and 20.0. Inset: Differential pulse stripping voltammograms of circle portion at low Sn2+ concentration are zoomed in.  相似文献   

9.
Periasamy AP  Umasankar Y  Chen SM 《Talanta》2011,83(3):930-936
A novel toluidine blue O (TBO) adsorbed alcohol dehydrogenase (ADH) biocomposite film have been prepared through simple adsorption technique with the help of electrostatic interaction between oppositely charged layers. Nafion (NF) coating was made on top of the biocomposite film modified glassy carbon electrode (GCE) to protect ADH from leaching. The fabricated ADH/TBO/NF biocomposite electrode remains highly stable in the pH range from 4 to 13. More facile electron transfer process occurs at ADH/TBO/NF biocomposite than at TBO/NF film, which is obvious from the six folds increase in ks value. Maximum surface coverage concentration (Γ) of TBO is noticed at ADH/TBO/NF film, which is 82% higher than at TBO/NF and 15% higher than at ADH/TBO film modified GCEs. Electrochemical impedance spectroscopy studies reveal that ADH has been well immobilized in the biocomposite film. Scanning electron microscopy studies confirm the discriminate surface morphology of various components present in the biocomposite film. Cyclic voltammetry studies validate that ADH/TBO/NF biocomposite film exhibits excellent electrocatalytic activity for ethanol oxidation at low over potential (Ipa = −0.14 V). The same studies show biocomposite film possesses a good sensitivity of 7.91 μA M−1 cm−2 for ethanol determination. This above sensitivity value is 17.40% higher than the sensitivity obtained for TBO/NF film (6.74 μA M−1 cm−2). Further, using differential pulse voltammetry, a sensitivity of 1.70 μA M−1 cm−2 has been achieved for ADH/TBO/NF biocomposite film.  相似文献   

10.
A glassy carbon electrode (GC) containing multiwalled functionalized carbon nanotubes (MWCNTs) immobilized within a dihexadecylhydrogenphosphate film (DHP) is proposed as a nanostructured platform for determination of methotrexate (MTX) concentration (a drug used in cancer treatment) using differential pulse adsorptive stripping voltammetry (DPAdSV). The voltammograms for a MTX solution using MWCNTs-DHP/GC electrode presented an oxidation peak potential at 0.98 V vs. Ag/AgCl (3.0 mol L?1 KCl) in a 0.1 mol L?1 sulphuric acid. The apparent heterogeneous electron transfer rate constant of 0.46 s?1 was calculated. The recovery area of 2.62×10?9 mol cm2 was also obtained. Under the optimal experimental conditions, the analytical curve was linear in the MTX concentration range from 5.0×10?8 to 5.0×10?6 mol L?1, with a detection limit of 3.3×10?8 mol L?1. The MWCNTs-DHP/GC electrode can be easily prepared and was applied for the determination of MTX in pharmaceutical formulations, with results similar to those obtained using a high-performance liquid chromatography comparative method.   相似文献   

11.
An electrochemical method for the determination of trace levels of mercury based on a multi-walled carbon nanotubes (MWNT) film coated glassy carbon electrode (GCE) is described. In 0.1 mol L–1 HCl solution containing 0.02 mol L–1 KI, Hg2+ was firstly preconcentrated at the MWNT film and then reduced at –0.60 V. During the anodic potential sweep, reduced mercury was oxidized, and then a sensitive and well-defined stripping peak at about –0.20 V appeared. Under identical conditions, a MWNT film coated GCE greatly enhances the stripping peak current of mercury in contrast to a bare GCE. Low concentrations of I remarkably improve the determining sensitivity, since this increases the accumulation efficiency of Hg2+ at the MWNT film coated GCE. The stripping peak current is proportional to the concentration of Hg2+ over the range 8×10–10–5×10–7 mol L–1. The lowest detectable concentration of Hg2+ is 2×10–10 mol L–1 at 5 min accumulation. The relative standard deviation (RSD) at 1×10–8 mol L–1 Hg2+ was about 6% (n=10). By using this proposed method, Hg2+ in some water samples was determined, and the results were compared with those obtained by atomic absorption spectrometry (AAS). The two results are similar, suggesting that the MWNT-film coated GCE has great potential in practical analysis.  相似文献   

12.
玻碳电极阳极微分脉冲伏安法测定雌激素   总被引:1,自引:0,他引:1  
邓家祺  张哲儒 《化学学报》1984,42(12):1262-1265
本文报道了雌激素的阳极微分脉冲伏安法测定.雌激素在甲醇-Britton-Robinson缓冲液中,以玻碳为工作电极,能获得一个良好的阳极氧化伏安峰,峰高与激素的浓度在1.0×10~(-6)~4.0×10~(-5)M之间有良好线性关系,峰电位随溶液pH值增加而降低,经循环伏安法验证,电极反应为不可逆反立.并报道了孕妇尿中雌三醇的测定.  相似文献   

13.
The heteropoly molybdosilicic acid complex produces five well-developed differential pulse voltammetric peaks at a glassy carbon electrode in citrate buffer solutions containing 20% 2-butanone with peak potentials in the neighborhood of +0.05 V, -0.10 V, -0.25 V, -0.50 V and -0.65 V (vs. Ag/AgCl, 0.1 M KCl). The peak current at each peak potential is clearly developed and is proportional to the silicon concentration; the linear range for the most useful peak at +0.05 V is 10-5–10-7 M silicon, the lower limit being fixed by the blank conditions. Nickel-base alloy samples and water samples were analyzed with satisfactory results.  相似文献   

14.
The authors describe a dopamine (DA) sensor based on a glassy carbon electrode modified with a composite film composed of carbon dots (C-dots) and graphene functionalized with an ionic liquid. The C-dots were functionalized with carboxy groups whose negative charge promotes electrostatic attraction to the protonated amino groups in DA. The presence of an imidazole cation in the IL facilitates interaction with the C-dots and DA via electrostatic interactions and π-stacking forces. Under optimal conditions, the modified GCE display improved electrochemical response to DA compared to a bare GCE, or a GCE modified with C-dots or IL-graphene only. The oxidation current, measured best at a potential of 0.22 V (vs. Ag/AgCl) is linearly related to the DA concentration in the 0.1 to 600 μM range, with a 30 nM detection limit at a signal-to-noise ratio of 3. Ascorbic acid does not interfere even in large excess, and the sensor is stable for at least a month. The modified GCE was applied to the determination of DA in spiked fetal bovine serum and gave satisfactory results.  相似文献   

15.
The voltammetric behavior of tannic acid (TA) on a single-wall carbon nanotubes (SWNTs) modified glassy carbon electrode has been investigated by cyclic voltammetry. TA can generate a well-defined anodic peak on the modified electrode at around 0.42 V (vs. SCE) in 0.10 M phosphate buffer solutions (pH = 4.0). The electrochemical reaction involves 1e transfer, accompanied by one proton. The electrode process is controlled by adsorption. The parameters affecting the response of TA, such as solution pH, accumulation time and accumulation potential are optimized for the determination of TA. Under the optimum conditions, the peak current changes linearly with the TA concentration in the range of 5.0 × 10−8–1.0 × 10−6 M. The lowest detectable concentration of TA is 8.0 × 10−9 M after 180 s accumulation. This method has been successfully applied to the determination of TA in tea and beer samples. In addition, the influence of potential interferents is examined. In the presence of bovine serum albumin, the peak current of TA decreases linearly due to the formation of a super-molecular complex.  相似文献   

16.
Yan Wang  Zhen-zhen Chen 《Talanta》2010,82(2):534-621
This report described the direct voltammetric detection of peroxynitrite (ONOO) at a novel cyanocobalamin modified glassy carbon electrode prepared by electropolymeriation method. The electrochemical behaviors of peroxynitrite at the modified electrode were studied by cyclic voltammetry. The results showed that this new electrochemical sensor exhibited an excellent electrocatalytic activity to oxidation of peroxynitrite. The mechanism of catalysis was discussed. Based on electrocatalytic oxidation of peroxynitrite at the poly(cyanocobalamin) modified electrode, peroxynitrite was sensitively detected by differential pulse voltammetry. Under optimum conditions, the anodic peak current was linear to concentration of peroxynitrite in the range of 2.0 × 10−6 to 3.0 × 10−4 mol L−1 with a detection limit of 1.0 × 10−7 mol L−1 (S/N of 3). The proposed method has been applied to determination of peroxynitrite in human serum with satisfactory results. This poly(cyanocobalamin) modified electrode showed high selectivity and sensitivity to peroxynitrite determination, which could be used in quantitative detection of peroxynitrite in vivo and in vitro.  相似文献   

17.
We report a simple method for the direct and quantitative determination of L-tryptophan (Trp) and L-tyrosine (Tyr) using a glassy carbon electrode (GCE) modified with single-walled carbon nanohorns (SWCNHs). The SWCNH modified GCE exhibits high electrocatalytic activity towards the oxidation of both Trp and Tyr. It shows a linear response to Trp between 0.5 and 50 μM and to Tyr between 2 and 30 μM. The detection limits for Trp and Tyr are 50 nM and 400 nM, respectively. In addition, the modified GCE displays good selectivity and good sensitivity, thus making it suitable for the determination of Trp and Tyr in spiked serum samples.
Figure
The electrochemical sensor based on single-walled carbon nanohorns modified glassy carbon electrode was presented. The fabricated electrochemical sensor exhibits favorable analytical performance for L-tryptophan and L-tyrosine with high sensitivity, low detection limit, and good reproducibility.  相似文献   

18.
Zhao H  Zhang Y  Yuan Z 《The Analyst》2001,126(3):358-360
A poly(2-picolinic acid) chemically modified electrode (CME) for the determination of dopamine (DA) by cyclic voltammetry is described. Compared with a bare glassy carbon electrode, the CME exhibits a 200 mV shift of the oxidation potential of DA in the cathodic direction and a marked enhancement of the current response. In pH 7.0 buffer solution, a linear calibration graph is obtained over the range from 2.5 x 10(-7) to 1.0 x 10(-5) mol dm-3 with a correlation coefficient of 0.998. The detection limit is 3.0 x 10(-8) mol dm-3. The modified electrode eliminated efficiently the interference from ascorbic acid (AA) when present in a 150-fold concentration ratio. It also showed excellent stability and reproducibility.  相似文献   

19.
聚溴酚蓝修饰电极对多巴胺的电催化作用及伏安测定   总被引:4,自引:1,他引:4  
在含溴酚蓝的磷酸缓冲液中,用循环伏安法在玻碳电极上制备聚合物薄膜。采用循环伏安法研究多巴胺在聚溴酚蓝修饰电极上的电化学行为,实验结果表明聚溴酚蓝修饰电极对多巴胺的氧化具有良好的电催化性能。在1.0~10μmol/L范围内,多巴胺浓度与其线性扫描伏安峰电流呈良好的线性关系,相关系数为0.9999,平均回收率为100.2%。该方法可用于盐酸多巴胺注射液中的多巴胺的测定。  相似文献   

20.
We have developed a method for the determination of the three catecholamines (CAs) epinephrine (EP), norepinephrine (NE), and dopamine (DA) at sub-nanomolar levels. It is found that the luminescence of the complexes formed between the CAs and Tb3+ ion is strongly enhanced in the presence of colloidal silver nanoparticles (Ag-NPs). The Ag-NPs cause a transfer of the resonance energy to the fluorophores through the interaction of the excited-state fluorophores and surface plasmon electrons in the Ag-NPs. Under the optimized condition, the luminescence intensity of the system is linearly related to the concentration of the CAs. Linearity is observed in the concentration ranges of 2.5–110?nM for EP, 2.8–240?nM for NE, and 2.4–140?nM for DA, with limits of detection as low as 0.25?nM, 0.64?nM and 0.42?nM, respectively. Relative standard deviations were determined at 10?nM concentrations (for n?=?10) and gave values of 0.98%, 1.05% and 0.96% for EP, NE and DA, respectively. Catecholamines were successfully determined in pharmaceutical preparations, and successful recovery experiments are demonstrated for urine and serum samples.
Figure
Schematic presentation of Ag NP-enhanced luminescence of Tb3+-CA complex. (A) Luminescence intensity at 545 nm of Tb3+-EP complex is lower than that of (B) Tb3+-EP-Ag NP system when both are excited at the wavelength of 279 nm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏