首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
High resolution gas chromatography, with mass selective detection, has been used for the analysis of PCB on methyl 50 % octyl polysiloxane (SB 50 Octyl), methyl octadecyl polysiloxane, and a smectic polysiloxane (SB Smectic); and for the analysis of polychlorodibenzodioxins and polychlorodibenzofurans with 1 to 8 chlorine substituents on 100 % cyanopropyl siloxane (SP 2331), smectic polysiloxane (SB Smectic), a new polar stationary phase (DB-Dioxin). The analysis has also been performed by column coupling.  相似文献   

2.
A method for the identification of fatty acid methyl esters (FAME) based on the analysis of shifts in equivalent chain lengths (ECL) is described. The method is based on two-dimensional retention data achieved on one capillary column. Various temperature and pressure programs are applied on the same cyanopropyl column and the shifts in the ECL values are analysed by multivariate methods. The chain length, number of double bonds, and the double bond positions can be determined with high accuracy. The same procedure is suitable for determination of the number of trans and cis double bonds in trans fatty acids, and for detection of artefacts in fatty acid methyl ester chromatograms.  相似文献   

3.
Capillary gas chromatography (CGC) in combination with mass spectrometry (MS) was optimized for the separation and detection of the fatty acids occurring in the lipid fraction of blood. A fingertip blood sample (ca. 50 microL) was transesterified into the methyl esters and analyzed on a 100 m x 0.25 mm ID column coated with a biscyanopropyl polysiloxane (HP-88) stationary phase. The method was retention time locked. Programmed temperature vaporization injection (PTV) in the solvent venting mode was applied to minimize the sample size, while maintaining high sensitivity. The total analysis time was ca. 60 min. Retention times and both electron impact (EI) and positive chemical ionization (PCI) mass spectrometry were combined to elucidate the fatty acids according to alkyl chain, degree of unsaturation and position of the double bonds. Using extracted ion chromatograms about 100 fatty acids and related compounds were detected in blood samples and most of them were identified. This work resulted in a very large fatty acid methyl esters database, containing retention time and mass spectral information that will be applied to metabolomic studies.  相似文献   

4.
This paper reports the separation of four isomers of conjugated linoleic acid (CLA), c,t/t,c-8,10; c,t/t,c-9,11; c,t/t,c-10,12; c,t/t,c-11,13, after reaction of esterification with aliphatic alcohols of different chain length and adduct formation with 4-methyl-1,2,4-triazoline-3,5-dione (MTAD). The high resolution gas chromatographic analyses were carried out using a simple 50-m cyanopropyl polysiloxane capillary column both with a flame ionization detector and a mass spectrometer. The resolution between the two pair of isomers: c,t/t,c-9,11 and c,t/t,c-10,12 and between c,t/t,c-10,12 and c,t/t,c-11,13 isomers were good for all the investigated alkyl esters and increased with the chain length of alcohol esterified to carboxylic moiety of CLA isomers. The most interesting result was relative to the c,t/t,c-8,10 and c,t/t,c-9,11 isomers, critical pair of isomers also when analyzed with a 120-m cyanopropyl polysiloxane capillary column; their resolution also increased from methyl to hexyl esters of CLA isomers and reached an acceptable value (0.8) in the case of hexyl esters. The best resolutions of the four considered CLA isomers were obtained with the hexyl esters of MTAD adducts of the isomers, without excessive analysis time. This method was useful and simple to evaluate the profile of the four main c,t isomers in commercial CLA samples.  相似文献   

5.
Coating intensely leached glass capillaries with OV-240-OH, the most polar commercially available OH-terminated polysiloxane phase at the present time, is described. Beside chemical bonding of the phase via condensation with silanol groups of the support, additional immobilization using dimethyltetramethoxysiloxane as a crosslinker is carried out. After in situ methylation of the immobilized coating, and transformation of acidic impurities of the cyanopropyl substituted phase into the respective methyl esters, increased inertness of the column was observed. Working instructions are given, and processes involved are discussed.  相似文献   

6.

Due to the negative impact of the presence of fatty acid methyl esters in kerosene for the aviation industry, in this work a comprehensive two-dimensional gas chromatography method with flame ionization detector for the determination of trace levels of fatty acid methyl esters in kerosene was developed. It is based on the use of a first dimension polar column and a second dimension non-polar column. Identification of fatty acid methyl esters is based on retention times and the external standard calibration is used for quantitation. Results were compared with those obtained from the GC–MS reference method; good recoveries, close to 100 %, and limit of detection in a range from 3 to 6 μg kg−1 were found without requiring a specific detector.

  相似文献   

7.
Harynuk  J.  Wynne  P. M.  Marriott  P. J. 《Chromatographia》2006,63(13):S61-S66
In the analysis of fatty acids, one of the most commonly used tools is a GC separation of the fatty acid methyl esters (FAME). Many researchers perform this separation using a non-polar phase such the ubiquitous 5% phenyl / 95% methyl capillary columns found in most every chromatography laboratory. Numerous laboratories have also turned recently to polar phases such as 70% cyanopropyl columns, as this type of chemistry provides increased selectivity for unsaturated compounds, and thus improved separation of cis/trans and ω3/ω6 FAME isomers. Here, a series of columns nominally having 60, 70, 80, and 90% bis-cyanopropyl content have been tested for the separation of FAME isomers. Trends in retention and the influence of increasing phase polarity on effective and fractional chain lengths are highlighted to provide the FAME chromatographer with insight into which of these novel stationary phases might be best suited to their particular application. In addition, the elution temperatures (Te) of the FAME and linear alkane standards are presented, as this information will be of value to comprehensive two-dimensional multidimensional GC (GC × GC) users who wish to use these columns in the primary dimension separation.  相似文献   

8.
Capillary ElectroChromatography (CEC) on a fused silica capillary column (40 cm L × 100 μm i.d.) packed with 3 μm octadecylsilica (ODS) was evaluated for the analysis of the triglycerides and their fatty acids in fish oils, and more especially in the oil of Moroccan Sardinia pilchardus. The very high complexity of the lipids in fish oil is well illustrated by CEC with a nonaqueous mobile phase consisting of acetonitrile/isopropanol/n-hexane in the ratio 57/38/5 to which 50 mM ammonium acetate has been added. In order to unravel the complexity, the oil was hydrolyzed and the free fatty acids (FFAs), the methyl esters (FAMEs), and the phenacyl esters (FAPEs) were analyzed by CEC on the same column used for the analysis of the triglycerides. Isocratic elution was achieved with the mobile phase acetonitrile/50 mM MES pH 6 in ratio 9/1. The migration characteristics of FFAs, FAMEs, and FAPEs are compared. The analysis of FAPE derivatives has the advantage that quantification applying UV detection is possible and moreover that the number of double bonds in the fatty acid chains can be elucidated by measuring the UV abundance ratio 240/210 nm.  相似文献   

9.
The ionic liquid SLB-IL111 column, available from Supelco Inc., is a novel fused capillary gas chromatography (GC) column capable of providing enhanced separations of fatty acid methyl esters (FAMEs) compared to the highly polar cyanopropyl siloxane columns currently recommended for the separation of cis- and trans isomers of fatty acids (FAs), and marketed as SP-2560 and CP-Sil 88. The SLB-IL111 column was operated isothermal at 168°C, with hydrogen as carrier gas at 1.0 mL/min, and the elution profile was characterized using authentic GC standards and synthetic mono-unsaturated fatty acids (MUFAs) and conjugated linoleic acid (CLA) isomers as test mixtures. The SLB-IL111 column provided an improved separation of cis- and trans-18:1 and cis/trans CLA isomers. This is the first direct GC separation of c9,t11- from t7,c9-CLA, and t15-18:1 from c9-18:1, both of which previously required complimentary techniques for their analysis using cyanopropyl siloxane columns. The SLB-IL111 column also provided partial resolution of t13/t14-18:1, c8- from c6/c7-18:1, and for several t,t-CLA isomer pairs. This column also provided elution profiles of the geometric and positional isomers of the 16:1, 20:1 and 18:3 FAMEs that were complementary to those obtained using the cyanopropyl siloxane columns. However, on the SLB-IL111 column the saturated FAs eluted between the cis- and trans MUFAs unlike cyanopropyl siloxane columns that gave a clear separation of most saturated FAs. These differences in elution pattern can be exploited to obtain a more complete analysis of complex lipid mixtures present in ruminant fats.  相似文献   

10.
李一哲  包桂蓉  王华 《色谱》2008,26(4):494-498
建立了采用超高效液相色谱(UPLC)-蒸发光散射检测器(ELSD)测定生物柴油中11种常见的脂肪酸及脂肪酸甲酯含量的方法。这11种常见的脂肪酸及脂肪酸甲酯为豆蔻酸、亚油酸、棕榈酸、油酸、亚麻酸甲酯、硬脂酸、亚油酸甲酯、棕榈酸甲酯、油酸甲酯、芥酸和硬脂酸甲酯。样品经提取后用甲醇溶解,采用Acquity UPLC BEH Phenyl C18柱(100 mm×2.1 mm,1.7 μm)分离,乙腈-水(体积比为3∶1)混合液为流动相进行等度洗脱,采用的ELSD条件为增益80,漂移管温度为45 ℃,载气压力为172 kPa,雾化器为冷却模式,并用外标法进行定量分析。结果表明,在一定的质量浓度范围内,峰面积的对数和质量浓度的对数线性关系良好。与其他检测生物柴油成分的方法相比,该方法简单,分离效果好,速度快,特别是此方法可以同时实现脂肪酸及脂肪酸甲酯的分离,并进行定量分析,能有效测定反应的进行程度,从而满足生物柴油工艺研究的需要。  相似文献   

11.
Four poly(methyl 3,3,3-trifluoropropyl siloxanes) with trifluoro-propyl group content (group substitution) between 8 and 35 percent have been synthesized and characterized as stationary phases for gas chromatography in borosilicate glass capillary columns. Results are compared with those from two commercial stationary phases–a polydimethylsiloxane and a poly(methyl 3,3,3-trifluoropropyl siloxane) with a fifty percent trifluoropropyl group content (group substitution). Retention index values, McReynolds constants, polarity (as defined by McReynolds) and retention polarity (as defined by Takács) increase regularly with the trifluoropropyl group content of the stationary phase. The temperature coefficient of the retention indices of the McReynolds probes, and that of the polarities, have been determined at temperatures between 60 and 180 °C. Specific retention volumes do not follow the linear dependence on trifluoropropyl group content observed for retention indices or polarities. Substances with electron-donor groups show maximum retention for a trifluoropropyl group content of ca 30%, whereas the retention of hydrocarbons, halogenated compounds, and alcohols decreases as the degree of trifluoropropyl group substitution increases from 0 to 50%. It is felt that a polysiloxane with a trifluoropropyl group content of ca 30 to 35% would be the best choice for the separation of ketones, nitro compounds or amines.  相似文献   

12.
The supercritical fluid chromatography of intact aliphatic amines with different columns is described. One group of amines was based on N,N-dimethyl-n-octylamine and related primary and secondary amines, and the other on the amino alcohol metoprolol and several of its analogues. Columns with three different phases were investigated, one non-polar coated with 5% phenyl methyl polysiloxane and two more polar with 25% cyanopropyl methylphenyl polysiloxane and Carbowax 20M. Generally, equal molar amounts were injected under splitless conditions and the peak symmetry was recorded. The system with the non-polar silicone phase was more inert, followed by the wax-phase column. The cyanopropyl column gave severe peak tailing although it was loaded with five times more of the amines than the other columns. The selectivity was investigated and was found higher with the two polar columns. Both showed a marked increase in the retention of amines with free hydrogens. With nitrous oxide the selectivity was almost the same as that with carbon dioxide as mobile phase. The nature of the flame ionization detector changed, however, giving a negative baseline drift on pressure programming. An interesting conclusion is that the amines are chromatographed as such with carbon dioxide as the mobile phase.  相似文献   

13.
Preparative capillary GC (PCGC) is a powerful tool for the separation and purification of compounds from any complex matrix, which can be used for compound‐specific radiocarbon analysis. However, the effect of PCGC parameters on the trapping efficiency is not well understood. Here, we present a comprehensive study on the optimization of parameters based on 11 reference compounds with different physicochemical properties. Under the optimum conditions, the trapping efficiencies of these 11 compounds (including high‐boiling‐point n‐hentriacontane and methyl lignocerate) are about 80% (60–89%). The isolation of target compounds from standard solutions, plant and soil samples demonstrates that our optimized method is applicable for different classes of compounds including n‐alkanes, fatty acid esters, long‐chain fatty alcohol esters, polycyclic aromatic hydrocarbons (PAHs) and steranes. By injecting 25 μL in large volume injection mode, over 100 μg, high purity (>90%) target compounds are harvested within 24 h. The recovery ranges of two real samples are about 70% (59.9–83.8%) and about 83% (77.2–88.5%), respectively. Compared to previous studies, our study makes significant improvement in the recovery of PCGC, which is important for its wide application in biogeochemistry, environmental sciences, and archaeology.  相似文献   

14.
Gradient elution reversed-phase high-performance liquid chromatography (RP-HPLC) was used for the determination of compounds occurring during the production of biodiesel from rapeseed oil. Individual triacylglycerols (TGs), diacylglycerols, monoacylglycerols and methyl esters of oleic, linoleic and linolenic acids and free fatty acids were separated in 25 min using a combined linear gradient with aqueous-organic and non-aqueous mobile phase steps: 70% acetonitrile+30% water in 0 min, 100% acetonitrile in 10 min, 50% acetonitrile+50% 2-propanol-hexane (5:4, v/v) in 20 min and 5 min final hold-up. Another method with a non-aqueous linear mobile phase gradient [from 100% methanol to 50% methanol+50% 2-propanol-hexane (5:4, v/v) in 15 min] was used for fast monitoring of conversion of rapeseed oil triacylglycerols to fatty acid methyl esters and for quantitation of residual TGs in the final biodiesel product. Sensitivity and linearity of various detection modes (UV detection at 205 nm, evaporative light scattering detection and mass spectrometric detection) were compared. The individual sample compounds were identified using coupled HPLC-atmospheric pressure chemical ionization mass spectrometry in the positive-ion mode.  相似文献   

15.
Summary The importance of selectivity in the capillary gas chromatographic analysis of the cellular fatty acids of micro-organisms is underestimated. The analysis on apolar silicone phases can lead to erratic elucidation of the fatty acid structure. Qualitative errors have been detected in commercially available standards on which computer matching identification techniques are based. Using highly polar capillary columns of the cyanopropyl silicone type, the errors could be elucidated. The exact identification of the hydrolysis products of bacteria is a must for chemotaxonomic studies applying chromatographic techniques. The fatty acid methyl ester profiles can also contain other chemical components which are very important taxonomic markers. Fatty aldehydes, for example, are main components in someClostridium species. Fractionation techniques are described for selective enrichment of fatty aldehydes and hydroxy fatty acids.Dedicated to Prof. Dr. A Liberti on the occasion of his 70th birthday  相似文献   

16.
A mild procedure for the purification of methyl esters of the fatty acid components of cholesterol esters, from interfering free cholesterol and other contaminating residues, is described. Methyl esters and free cholesterol are formed during the methylation of cholesterol esters. When co-extracted, cholesterol and other contaminating residues interfere with the methyl esters because minute proportions of these residues tend to elute at the same retention times as palmitoleic and stearic acids, to yield unreliable but significantly higher values for palmitoleic (p less than 0.001) and stearic acids (p less than 0.0001), and correspondingly lower values for oleic acid (p less than 0.0001). Purification of methyl esters by thin-layer chromatography eliminates this problem and yields reliable analysis of cholesterol ester fatty acids, without measurable oxidation of unsaturated fatty acids.  相似文献   

17.
邵仕萍  相大鹏  李双  奚星林  陈文锐 《色谱》2015,33(11):1214-1218
建立了盐酸水解,索氏提取总脂肪酸,氢氧化钾甲醇溶液甲酯化,硫酸氢钠处理,气相色谱测定奶粉中二十二碳六烯酸(DHA)含量的方法。采用三因素三水平正交试验对氢氧化钾甲醇溶液甲酯化条件进行了优化,得到最优反应条件为:1 mol/L氢氧化钾在25 ℃反应5 min。甲酯化衍生液经硫酸氢钠处理,在SP-2560气相色谱柱(100 m×0.25 mm×0.20 μ m)上进行55 min程序升温测定DHA含量。DHA在5.0~300 mg/L范围内呈良好线性,相关系数为0.9999。DHA质量浓度为10、50、100 mg/L时目标峰峰面积的相对标准偏差(RSD)分别为3.4%、1.2%和1.1%。方法检出限为2 mg/kg,回收率为90.4%~93.5%。该法用于实际样品的检测,结果令人满意。  相似文献   

18.
Ionic liquid stationary phases were tested for one dimensional gas chromatography-mass spectrometry (GC-MS) and comprehensive two dimensional gas chromatography (GC×GC) of fatty acid methyl esters from algae. In comparison with polyethylene glycol and cyanopropyl substituted polar stationary phases, ionic liquid stationary phases SLB-IL 82 and SLB-IL 100 showed comparable resolution, but lower column bleeding with MS detection, resulting in better sensitivity. The selectivity and polarity of the ionic liquid phases are similar to a highly polar biscyanopropyl-silicone phase (e.g. HP-88). In GC×GC, using an apolar polydimethyl siloxane×polar ionic liquid column combination, an excellent group-type separation of fatty acids with different carbon numbers and number of unsaturations was obtained, providing information that is complementary to GC-MS identification.  相似文献   

19.
The GC–MS characteristics of carboxylic acid esters prepared from fluorine-containing alcohols were compared to those of methyl esters. The GC retention of 2,2,2-trifluoroethyl (TFE) esters was less than, and 2,2,3,3,4,4,4-heptafluoro-1-butyl (HFB) esters was approximately equivalent to that of methyl esters. Mass spectra of TFE and HFB aliphatic esters show significantly more intense molecular and key fragment ions than those of methyl esters. Also, owing to their significantly higher molecular weights, TFE or HFB ester molecular ions and most fragment ions of interest occur at significantly higher m/z values than most potential interfering ions. Data for about 70 individual TFE and HFB esters are reported. Application of the methodology to a petroleum-derived carboxylic acid concentrate resulted in identification of straight chain, isoprenoid, methyl-substituted straight chain (2-, 3-, 5-,10-, 12-positions along chain), and dimethyl-substituted straight chain acids containing from 11 to 22 carbons. Benzoic acid and homologs with up to 3-carbons in alkyl substitutents were minor components in the sample. The procedure provided for forming TFE and HFB esters from free acids requires less time and effort than a previously reported method, while retaining its capability for achieving essentially quantitative conversion. Free hydroxyl groups in alcohols and phenols are converted to trifluoroacetate esters concurrently with formation of TFE/HFB carboxylic acid esters. The reaction products, including compounds with two functional groups (diacids, salicylic acid, etc.), chromatograph well on conventional nonpolar GC stationary phases.  相似文献   

20.
Gas chromatography-mass spectrometry was applied to the cyclohexane extract of Curcuma longa L. The chromatographic conditions generated retention indices very close i.e., greater than 99.9%, to those reported for structures in the Sadtler Standard Gas Chromatography Retention Index Library. In addition to the extensively reported sesquiterpene ketones, this essential oil extract contained a series of saturated and unsaturated fatty acids. Wiley mass spectra library matching for the free fatty acids, their trimethylsilyl esters and methyl esters narrowed their identity down to a few candidates. Combining this information with the retention indices of the fatty acid methyl esters in the Sadtler library allowed the identification of some of the double bond positions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号