首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Time-of-flight mass spectrometry (ToF-MS) has gained wide acceptance in many fields of chemistry, proteomics, metabolomics and small molecule analysis. ToF-MS, however, has some inherent advantages and drawbacks. Numerous developments have been made to hybrid ToF instruments to improve their capabilities. We have used a quadrupole orthogonal acceleration ToF (Q-oa-ToF) instrument to assess developments made to improve resolution, dynamic range and signal-to-noise (S/N) ratios (i.e. sensitivity). Higher mass resolution can improve the analysis of mixtures containing compounds with similar m/z values and improved mass accuracy gives greater confidence for structural elucidation applications. Wide dynamic ranges are necessary for the analysis of unknown samples or samples that vary widely in analyte concentrations. The performance of the advanced functionalities for routine structural elucidation in terms of resolution, dynamic range and S/N ratios was investigated using test compounds. The results presented in this work demonstrate and validate the use of these new enhancements for Q-ToF instruments and also show their limitations.  相似文献   

2.
Optimisation of the activation parameters for ion trap mass spectrometric analysis of the chlormequat cation using simplex optimisation enabled the product ion (m/z 58) response to be improved 1000-fold. A comparison of the sensitivity of the optimised ion trap mass spectrometer with that of a triple quadrupole mass spectrometer for liquid chromatography/tandem mass spectrometry (LC/MS/MS) showed that similar limits of detection (LODs) could be achieved. For the MS/MS transition of the (35)Cl precursor to the most abundant product, LODs were 0.8 ng cation mL(-1) (0.004 mg cation kg(-1) pear equivalent) and 1.0 ng cation mL(-1) (0.005 mg cation kg(-1) pear equivalent) on the triple quadrupole and ion trap instrument, respectively.  相似文献   

3.
The performances of four different mass spectrometers [triple-quadrupole (TQ), time-of-flight (ToF), quadrupole ToF (Q-ToF) and ion trap (IT)] for the detection of the marine lipophilic toxins pectenotoxin-2 (PTX2) and okadaic acid (OA) were investigated. The spectral data obtained with the different mass spectrometric analyzers were used to propose fragmentation schemes for PTX2 in the positive electrospray mode and for OA in the negative electrospray mode. TQ data were used to obtain product ions, while ToF and Q-ToF-MS produced accurate mass data of the precursor ion and product ions, respectively. IT data provided a better understanding of the fragmentation pathways using MS(n) experiments. With respect to analytical performance, all four mass analyzers showed a good linearity (R(2) > 0.97) and repeatability (CV < 20%). Detection limits (LoDs) (S/N = 3) were the lowest on triple-quad MS: 12.2 and 2.9 pg on-column for PTX2 and OA, respectively.  相似文献   

4.
Five different mass spectrometers interfaced to GC or LC were evaluated for their application to targeted and nontargeted screening of pesticides in two foods, spinach and ginseng. The five MS systems were capillary GC/MS/MS, GC-high resolution time-of-flight (GC/HR-TOF)-MS, TOF-MS interfaced with a comprehensive multidimensional GC (GCxGC/TOF-MS), an MS/MS ion trap hybrid mass (qTrap) system interfaced with an ultra-performance liquid chromatograph (UPLC-qTrap), and UPLC interfaced to an orbital trap high resolution mass spectrometer (UPLC/Orbitrap HR-MS). Each MS system was tested with spinach and ginseng extracts prepared through a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) procedure. Each matrix was fortified at 10 and 50 ng/g for spinach or 25 and 100 ng/g for ginseng with subsets of 486 pesticides, isomers, and metabolites representing most pesticide classes. HR-TOF-MS was effective in a targeted search for characteristic accurate mass ions and identified 97% of 170 pesticides in ginseng at 25 ng/g. A targeted screen of either ginseng or spinach found 94-95% of pesticides fortified for analysis at 10 ng/g with GC/MS/MS or LC/MS/MS using multiple reaction monitoring (MRM) procedures. Orbitrap-MS successfully found 89% of 177 fortified pesticides in spinach at 25 ng/g using a targeted search of accurate mass pseudomolecular ions in the positive electrospray ionization mode. A comprehensive GCxGC/TOF-MS system provided separation and identification of 342 pesticides and metabolites in a single 32 min acquisition with standards. Only 67 or 81% of the pesticides were identified in ginseng and spinach matrixes at 25 ng/g or 10 ng/g, respectively. MS/MS or qTrap-MS operated in the MRM mode produced the lowest false-negative rates, at 10 ng/g. Improvements to instrumentation, methods, and software are needed for efficient use of nontargeted screens in parallel with triple quadrupole MS.  相似文献   

5.
This study compared the sensitivities and matrix effects of four ionization modes and four reversed-phase liquid chromatographic (LC) systems on analyzing estrone (E1), 17β-estradiol (E2), estriol (E3), 17α-ethinylestradiol (EE2), 4-nonylphenol (NP), 4-tert-octylphenol (OP), bisphenol A (BPA) and their derivatives of dansyl chloride or pentafluorobenzyl bromide (PFBBr) in water matrixes using a triple-quadrupole mass spectrometer with selected reaction monitoring (SRM). The four probes were electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI) and APCI/APPI; the four LC systems were ultra-performance liquid chromatography (UPLC) with or without post-column split, a mixed-mode column and two-dimensional LC (2D-LC). Dansylated compounds with ESI at UPLC condition had the most intense signals and less matrix effects of the various combinations of ionization and LC systems. The on-column limits of detection (LODs) of dansylated estrogens by SRM were 0.05–0.20 pg, and the LODs in sewage treatment plant effluent and in river water were 0.23–0.52 and 0.56–0.91 ng/L, respectively. The LODs using selected ion monitoring (SIM) reached low ng/L levels in real samples and measured concentrations were comparable with those of SRM.  相似文献   

6.
Four liquid chromatography/mass spectrometry (LC/MS) systems, equipped with single quadrupole, triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole time-of-flight (QqTOF) mass analyzers, were evaluated for the analysis of carbosulfan and its main transformation products. The comparison of quantitative aspects (sensitivity, precision and accuracy) was emphasized. Results showed that the triple quadrupole instrument reaches at least 20-fold higher sensitivity (LOD from 0.04 to 0.4 microg kg(-1)) compared to the single quadrupole (4-70 microg kg(-1)), the QIT (4-25 microg kg(-1)) and the QqTOF (4-23 microg kg(-1)) instruments. Recoveries were over 70% for all the analytes, except dibutylamine and 7-phenolcarbofuran. Repeatabilities (within-day) were slightly better by the single quadrupole (5-10%) and the QqQ (5-9%) than by the QIT (12-16%) and the QqTOF (9-16%). Both the QqTOF and QIT offer a linear dynamic range of two orders of magnitude whereas the single quadrupole and QqQ of, at least, three orders of magnitude. The method was applied to analyze carbosulfan field-treated orange samples, in which carbosulfan, carbofuran, 3-hydroxycarbofuran, and dibutylamine were found. As an example, the mean carbosulfan concentration was 20 +/- 0.6 microg kg(-1) measured by the QqQ, 22 +/- 1.2 microg kg(-1) by the single quadrupole, 25 +/- 2.8 microg kg(-1) by the QIT, and 20 +/- 1.8 microg kg(-1) by the QqTOF. Although the QqQ is more sensitive and precise, the mean values obtained by the four instruments are acceptable and comparable. The potential of each technique for the verification of the identity of residues detected in oranges is discussed using the concept of identification points.  相似文献   

7.
Electrospray ionisation ion trap mass spectrometry (ESI-MS(n)) has been used to study the fragmentation patterns of nicotine and nine of its related compounds. From this study certain characteristic fragmentations are apparent with generally the pyrrolidine or piperidine ring being subject to chemical modifications. The structures of the product ions proposed for the ESI-MS(n) study have been supported by results from electrospray ionisation quadrupole time-of-flight mass spectrometry (ESI-QTOF-MS). Compounds with pyrrolidine and piperidine rings that possess an unsubstituted N atom have been shown to lose NH(3) at the MS(2) stage. Those compounds with N-methyl groups lose CH(3)NH(2) at the MS(2) stage. The loss of NH(3) or CH(3)NH(2) leaves the corresponding rings opened and this is followed by ring closure at the pyridine-2 carbon atom. Mono-N-oxides fragment in a similar way but the di-N-oxide can also fragment by cleavage of the bond between the pyridine and pyrrolidine rings. Cotinine also can undergo cleavage of this bond between the rings.This data therefore provides useful information on how substituents and the nature of the non-pyridine ring can affect the fragmentation patterns of nicotine and its related compounds. This information can be used in the characterisation of these compounds by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) which results in the separation of nicotine and its related compounds with limits of detection (LODs) ranging from 15 to 105 ng/mL. The use of LC/ESI-MS to study nicotine-containing samples resulted in the simultaneous and unambiguous identification of seven of the compounds discussed in this paper: cotinine identified at retention time 12.5 min (with its [M+H](+) ion at m/z 177), nornicotine 16.0 min (m/z 149), anatabine 18.0 min (m/z 161), myosmine 18.5 min (m/z 147), anabasine 20.4 min (m/z 163), nicotine 22.2 min (m/z 163), and nicotyrine 31.4 min (m/z 159). For quality control of nicotine replacement therapy products, these nicotine impurities can be readily identified and determined at levels up to 0.3% for single impurities and up to 1.0% for total impurities.  相似文献   

8.
Zhang F  Chu X  Sun L  Zhao Y  Ling Y  Wang X  Yong W  Yang M  Li X 《Journal of chromatography. A》2008,1209(1-2):220-229
Gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) with a triple quadrupole analyzer (QqQ) was applied for the first time to the determination of trace food-derived hazardous compounds in food samples. Thirteen heterocyclic amines were confirmed and quantified by the developed sensitive method. The method includes a solid-phase extraction procedure with a polystyrene copolymer cartridge (LiChrolut EN), followed by a derivatization reaction with N,N-dimethylformamide di-tert-butylacetal. Analyses were performed by gas chromatography with triple quadrupole mass spectrometry in the electron impact mode. The MS/MS fragmentation pathway of derived heterocyclic amines was studied and the differences of fragmentation characteristics were used successively to distinguish the isomers in absence of chemical standards. The excellent selectivity and sensitivity achieved in multiple reaction monitoring mode allowed us satisfactory quantitation and confirmation. The limits of quantitation of the method for these compounds ranged from 0.12 to 0.48ng/g of sample. The method developed was applied to the analysis of Chinese cooked foods, and the results demonstrated the potentiality of the GC-MS/MS method for the analysis of trace food-derived hazardous compounds in complex food matrices such as meat samples.  相似文献   

9.
The potential of gas chromatography coupled to tandem mass spectrometry (GC/MS/MS) with a triple quadrupole analyzer (QqQ) has been investigated for the quantification and reliable identification of sixteen polycyclic aromatic hydrocarbons (PAHs) from the EPA priority list in animal and vegetable samples from aquaculture activities, whose fat content ranged from 5 to 100%. Matrices analyzed included fish fillet, fish feed, fish oil and linseed oil. Combining optimized saponification and solid‐phase extraction led to high efficiency in the elimination of interfering compounds, mainly fat, from the extracts. The developed procedure minimized the presence of these interfering compounds in the extracts and provided satisfactory recoveries of PAHs. The excellent sensitivity and selectivity of GC/(QqQ)MS/MS in selected reaction monitoring (SRM) allowed to reach limits of detection at pg/g levels. Two SRM transitions were acquired for each analyte to ensure reliable identification of compounds detected in samples. Confirmation of positive findings was performed by GC coupled to high‐resolution time‐of‐flight mass spectrometry (GC/TOFMS). The accurate mass information provided by GC/TOFMS in full acquisition mode together with its high mass resolution makes it a powerful analytical tool for the unequivocal confirmation of PAHs in the matrices tested. The method developed was applied to the analysis of real‐world samples of each matrix studied with the result of detecting and confirming the majority of analytes at the µg/kg level by both QqQ and TOF mass spectrometers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Vitellogenin (VTG) is a protein produced by the liver of oviparous animals in response to circulating estrogens. In the plasma of males and immature females, VTG is undetectable. VTG has been used as a biomarker for exposure to endocrine disruptors in many species. In the present study, characterization of intact Atlantic salmon VTG was effected using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI ToF MS). Tryptic digest peptides were analyzed by MALDI ToF MS to obtain a peptide mass fingerprint. De novo sequencing of the tryptic peptides used low-energy collisionally-induced dissociation (CID) in an electrospray ionization quadrupole-ToF orthogonal hybrid mass spectrometer (ESI Q-ToF MS/MS). The interpretation of the product-ion spectra obtained from the ESI Q-ToF MS/MS was done by Lutefisk, a computer-based software algorithm. The molecular mass of the intact protein was found to be 187335 Da. A total of 14 tryptic peptides were sequenced and compared with the complete rainbow trout VTG and the partial Atlantic salmon VTG sequences found in the Swiss-Prot database. De novo sequencing by CID MS/MS of 11 Atlantic salmon tryptic digest peptides with selected precursor ions at m/z 788.24, 700.20, 794.75, 834.31, 889.28, 819.79, 865.27, 843.81, 572.20, 573.66 and 561.68 showed high homology with the known sequence of rainbow trout VTG. The last two precursor peptide ions, found at m/z 573.66 and m/z 561.68, also specifically matched the known portion of the Atlantic salmon VTG sequence. Finally, three tryptic precursor peptide ions found at m/z 795.18, 893.28 and 791.05, provided product-ion spectra, which were exclusive to the unsequenced portion of the Atlantic salmon VTG.  相似文献   

11.
Monensin is an anticoccidial drug that has been used as an additive in medicated feed. The United States Food and Drug Administration (USFDA) has included monensin in the national surveillance schemes for residues in foodstuff. In this study, two simple, selective and rapid methods were developed to determine monensin content in animal feed and milk. The methods enabled the detection of monensin residues as low as 1 ppb. Moreover, the two methods were used as models to compare two common liquid chromatography/tandem mass spectrometry (LC/MS/MS) platforms; an LC linear ion trap (LC/LIT) and an LC triple quadrupole (LC/QqQ). The two instrument platforms were evaluated for their matrix effect dependence, precision and accuracy. The LC/QqQ presented a lower limit of detection and limit of quantitation (LOD and LOQ) and showed less matrix dependence as compared to the LC/LIT. The LC/QqQ instrument also demonstrated a better intermediate precision. For example, the intermediate precision standard deviation calculated for 27 analyses across three days was 4% and 11% for LC/QqQ and LC/LIT, respectively. Overall, the LC/QqQ represents a better choice for analysis of monensin with respect to LOD, LOQ, matrix interference and precision. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
The use of a hybrid triple quadrupole-linear ion trap (QqQ(LIT)) mass spectrometer system for a comprehensive study of fragmentation mechanisms is described. The anxiolytic drug, buspirone, was chosen as a model compound for this study. With the advent of a QqQ(LIT) instrument, both the traditional quadrupole and the new linear ion trap scans (LIT) could be performed in a single LC run. In the past, a sample had to be run on two different instruments, namely, a triple quadrupole instrument (QqQ) and a 3D ion trap (3D IT) to obtain similar information. With the new QqQ(LIT) technology, collision-induced dissociation (CID) occur in a quadrupole collision cell, q2, and fragment ions are trapped and analyzed in Q3 operated in LIT mode. In this work, high-sensitivity product ion spectra of buspirone were obtained from the one-stage 'Enhanced Product Ion' scan (EPI) with rich product ions and no low mass cut-off. Furthermore, detailed fragmentation pathways were elucidated by further dissociation of each of the fragment ions in the EPI spectrum using MS(3) mode in the same run. The MS(3) scan was performed by incorporating CID in q2, and trapping, cooling, isolation, and resonance-excitation in Q3 when operating in LIT mode. This approach allowed unambiguous assignment of all fragment ions quickly with fewer experiments and easier interpretation than the previous approach. The overall sensitivity for obtaining complete fragment ion data was significantly improved for QqQ(LIT) as compared with that of QqQ and 3D IT mass spectrometers. This is beneficial for structure determination of unknown trace components. The method allowed structure determination of metabolites of buspirone in rat microsomes at 1 microM concentration, which was a 10-fold lower concentration than was needed for QqQ or 3D IT instruments. The QqQ(LIT) instrument provided a simple, rapid, sensitive and powerful approach for structure elucidation of trace components.  相似文献   

13.
房康  郭项雨  王宏伟  熊行创  白桦  雷海民  马强 《色谱》2019,37(7):742-749
采用液相色谱-电喷雾电离-离子迁移谱联用技术,研究建立了中药口服液中丹参素、甘草酸、天麻素、绿原酸、葛根素、黄芩苷、芦丁等7种指标性成分的二维分离分析方法。样品溶液首先经ACQUITY UPLC BEH C18色谱柱(50 mm×1 mm,1.7 μm)分离后,导入可调节式分流器(分流比50 ∶ 1),柱后流出液分别进入离子迁移谱和三重四极杆质谱检测。分别详细优化了液相色谱、喷雾电压、迁移管和气体预加热温度、漂移气流速等实验条件,同时建立了指标性成分的液相色谱-三重四极杆质谱确证方法。7种中药指标性成分的检出限为2~10 μg/mL,定量限为5~25 μg/mL。采用本方法对中药口服液实际样品进行了检测分析。通过将液相色谱和离子迁移谱进行偶联,可实现目标化合物同时基于疏水性和离子迁移率差异的二维分离,获得更为丰富的测试信息。  相似文献   

14.
Two liquid chromatography mass spectrometric techniques, i.e. ultra-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/Q-Tof MS) and high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS), were used for quantification, confirmation or identification of six macrolide antibiotic residues and/or their degradation products in eggs, raw milk, and/or honey. Macrolides were extracted from food samples by acetonitrile or phosphate buffer (0.1 M, pH 8.0), and sample extracts were further cleaned up using solid-phase extraction cartridges. UPLC/Q-Tof data were acquired in Tof MS full scan mode that allowed both quantification and confirmation of macrolides, and identification of their degradation products. LC/MS/MS data acquisition was achieved using multiple reaction monitoring (MRM), i.e. two transitions, to provide a high degree of sensitivity and repeatability. Matrix-matched standard calibration curves with the use of roxithromycin as an internal standard were utilized to achieve the best accuracy of the method. Both techniques demonstrated good quantitative performance in terms of accuracy and repeatability. LC/MS/MS had advantages over UPLC/Q-Tof MS in that its limits of detection were lower and repeatability was somewhat better. UPLC/Q-Tof provided ultimate and unequivocal confirmation of positive findings, and allowed degradation product identification based on accurate mass. The combination of the two techniques can be very beneficial or complementary in routine analysis of macrolide antibiotic residues and their degradation products in food matrices to ensure the safety of food supply.  相似文献   

15.
The field of drug metabolism has been revolutionized by liquid chromatography/mass spectrometry (LC/MS) applications with new technologies such as triple quadrupoles, ion traps and time-of-flight (ToF) instrumentation. Over the years, these developments have often relied on the improvements to the mass spectrometer hardware and software, which has allowed users to benefit from lower levels of detection and ease-of-use. One area in which the development pace has been slower is in high-performance liquid chromatography (HPLC). In the case of metabolite identification, where there are many challenges due to the complex nature of the biological matrices and the diversity of the metabolites produced, there is a need to obtain the most accurate data possible. Reactive or toxic metabolites need to be detected and identified as early as possible in the drug discovery process, in order to reduce the very costly attrition of compounds in late-phase development. High-resolution, exact mass measurement plays a very important role in metabolite identification because it allows the elimination of false positives and the determination of non-trivial metabolites in a much faster throughput environment than any other standard current methodology available to this field. By improving the chromatographic resolution, increased peak capacity can be achieved with a reduction in the number of co-eluting species leading to superior separations. The overall enhancement in the chromatographic resolution and peak capacity is transferred into a net reduction in ion suppression leading to an improvement in the MS sensitivity. To investigate this, a number of in vitro samples were analyzed using an ultra-performance liquid chromatography (UPLC) system, with columns packed with porous 1.7 mum particles, coupled to a hybrid quadrupole time-of-flight (ToF) mass spectrometer. This technique showed very clear examples for fundamental gains in sensitivity, chromatographic resolution and speed of analysis, which are all important factors for the demands of today's HTS in discovery.  相似文献   

16.
In this work, ultra‐performance LC with ESI quadrupole TOF‐MS (UPLC–ESI‐Q‐TOF‐MS) and automated MetaboLynx analysis was used to rapidly separate and identify the chemical constituents of Danggui San, a traditional Chinese medical formula. The analysis was performed on a Waters UPLC BEH C18 column using a gradient elution system. A hyphenated ESI and Q‐TOF analyzer was used for the determination of the accurate mass of the protonated or deprotonated molecule and fragment ions in both positive and negative modes. Based on retention times, accurate mass, and the mass spectrometric fragmentation characteristics, a total of 47 compounds distributed over the chemical groups of phthalides, flavonoids, monoterpene glycosides, sesquiterpenoids, phenolics, and alkaloids, were simultaneously separated within 18 min and identified or tentatively elucidated in Danggui San for the first time. UPLC–ESI‐Q‐TOF‐MS analysis revealed the complexity of the chemical composition of this formula. The method developed is rapid, accurate, reliable, and highly sensitive to characterize the chemical constituents of Danggui San.  相似文献   

17.
An analog of aildenafil, which is a potent and highly selective inhibitor of phosphodiesterase 5, was found in a dietary supplement marketed for enhancement of sexual function. The compound was isolated by silica gel column chromatography, and its structure was identified by means of 13C-NMR spectrometry, 1H-NMR spectrometry, high-resolution MS, and X-ray structure determination. The compound was identified to be sulfoaildenafil (other names: thioaildenafil, dimethyl sildenafil thione, and thiomethisosildenafil). Sulfoaildenafil is very similar to the compound thiohomosildenafil. As it is difficult to distinguish between them by LC-photodiode array detector analysis, ultra-performance LC (UPLC)/MS, ion trap LC/MS/MS (LC/IT-MS/MS), and GC/MS were performed. The mass spectra of thiohomosildenafil by UPLC/MS and LC/IT-MS/MS showed mass fragments of m/z 58, 72, and 355, and the mass spectrum by GC/MS showed mass fragments of m/z 56, 72, and 420. Some of these fragments had low intensities, but they were useful for distinguishing between the two compounds. The relationship between aildenafil (other names: dimethylsildenafil and methisosildenafil) and homosildenafil is similar to that between sulfoaildenafil and thiohomosildenafil. Therefore, these compounds were also examined.  相似文献   

18.
The purpose of the study was to determine the advantages of different mass spectrometric instruments and commercially available metabolite identification programs for metabolite profiling. Metabolism of tramadol hydrochloride and the excretion of it and its metabolites into human urine were used as a test case because the metabolism of tramadol is extensive and well known. Accurate mass measurements were carried out with a quadrupole time-of-flight mass spectrometer (Q-TOF) equipped with a LockSpray dual-electrospray ionization source. A triple quadrupole mass spectrometer (QqQ) was applied for full scan, product ion scan, precursor ion scan and neutral loss scan measurements and an ion trap instrument for full scan and product ion measurements. The performance of two metabolite identification programs was tested. The results showed that metabolite programs are time-saving tools but not yet capable of fully automated metabolite profiling. Detection of non-expected metabolites, especially at low concentrations in a complex matrix, is still almost impossible. With low-resolution instruments urine samples proved to be challenging even in a search for expected metabolites. Many false-positive hits were obtained with the automated searching and manual evaluation of the resulting data was required. False positives were avoided by using the higher mass accuracy Q-TOF. Automated programs were useful for constructing product ion methods, but the time-consuming interpretation of mass spectra was done manually. High-quality MS/MS spectra acquired on the QqQ instrument were used for confirmation of the tramadol metabolites. Although the ion trap instrument is of undisputable benefit in MS(n), the low mass cutoff of the ion trap made the identification of tramadol metabolites difficult. Some previously unreported metabolites of tramadol were found in the tramadol urine sample, and their identification was based solely on LC/MS and LC/MS/MS measurements.  相似文献   

19.
A liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) method was developed using the latest high-resolution LC column technology, the ultra performance liquid chromatography (UPLC), and electrospray ionization (ESI) in the positive ion mode. Gradient UPLC separation conditions were optimized for a group of 22 analytes comprising 17 glucocorticosteroids, specific designer steroids such as tetrahydrogestrinone (THG) and specific beta2-agonists such as formoterol. The UPLC/TOFMS separation obtained required 5.5 min only for all the substances tested. Even the critical pair of dexamethasone and betamethasone isomers was almost completely resolved. Thanks to the over 10,000 full-width at half maximum (FWHM) mass resolution and high mass accuracy features of TOFMS 50 mDa window accurate mass chromatograms could be reconstructed for the individual analytes. Sensitive screening in human and calf urine samples fortified at the glucocorticosteroids minimum required performance limit (MRPL) of 30 microg L(-1) (human urine, sports doping) and 2 microg L(-1) (calf urine, veterinary control) could be obtained. The potential of UPLC/TOFMS for confirmatory analysis was shown by determining the accurate mass of all compounds and fragment ions upon in-source collision-induced dissociation (CID) at different energies. The exact mass measurement errors for all glucocorticosteroids were found to be within 6 ppm. Considering veterinary control, limits of detection (LOD) and limits of quantification (LOQ) were determined for most of the analytes in calf urine and found to range from 0.1 to 3.3 and from 0.4 to 4.4 microg L(-1), respectively. The method can be easily extended with other banned substances of interest, as demonstrated by the addition of 21 beta2-agonists to the original analyte mixture in urine, without causing any interferences.  相似文献   

20.
Within the European Union the use of anabolic steroids for promoting growth and improving meat-to-fat ratio in food-producing animals has been banned since 1988. For the unequivocal identification of hormone residues in a complex matrix such as meat we have developed a rapid, specific and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, in combination with a simple extraction procedure based on the matrix solid-phase dispersion (MSPD). The performances of a triple quadrupole (QqQ) and a quadrupole/time-of-flight (QqTOF) were compared: the QqQ mass spectrometer was found to be more sensitive for almost all studied analytes, but the selectivity was superior using the QqTOF system; the full-scan spectra (acquired without losing sensitivity), mass accuracy and resolution of the hybrid instrument enabled a more probatory analyte identification than that obtained selecting two multiple-reaction monitoring (MRM) transitions with a QqQ. Average recoveries ranged from 80 to 100%, and the detection capabilities (CCbetas) were less than 1.06 ppb with the QqQ instrument and less than 5.20 ppb with the QqTOF instrument for the bovine meat, which proved to be the most complex matrix.  相似文献   