首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Classification of normal and different cancer groups (TNM classification) with univariate and multivariate statistical methods according to the contents of Cu, Fe, Mn, Se, and Zn in blood serum is discussed. All serum samples were digested by acid mixture in a microwave mineralization unit prior to the analysis by atomic absorption spectrometry. Results show that univariate methods can distinguish normal and cancer groups. Level of selenium evaluated as arithmetic mean with its standard deviation in colorectal cancer patients was (42.61 ± 23.76) μg L−1. Retransformed mean was used to evaluate levels of managanese (11.99 ± 1.71) μg L−1, copper (1.05 ± 0.06) mg L−1, zinc (2.14 ± 0.21) mg L−1, and iron (1.82 ± 0.22) mg L−1. Conclusions of multivariate statistical procedures (principal component analysis, hierarchical, and k-means clustering) do not correlate very well with the division of serum samples according to the TNM classification.  相似文献   

2.
A kinetic-potentiometric method is described for the quantitative assay of formaldehyde (HCHO) in pharmaceutical and industrial preparations. It is based on the reaction of HCHO with (ethylenediamine)-Cu(II)-sulfate [Cu(CH2NH2)2(H2O)2] · SO4. The changes in potential, resulting from the release of the Cu(II) cations, are monitored with a Cu(II)-ion selective electrode. The calibration curve for the HCHO is linear in the concentration range 50–250 mg L−1, with a limit of detection of 8.5 mg L−1. The method shows very good reproducibility with an RSD of 2.6% for successive injections (n = 5) of 150 mg L−1 HCHO primary solution, while it is interference free. The method was successfully tested in various industrial and pharmaceutical preparations.  相似文献   

3.
We propose a novel combination of high-throughput luminescent bacterial tests for the evaluation of the reactive oxygen species (ROS)-generating potential of engineered nanoparticles (eNPs) and the role of solubilised metal ions in this process. The set of tests consists of differently engineered recombinant Escherichia coli strains: (1) a new sensor strain, which bioluminescence is induced by superoxide anions; (2) six recombinant E. coli strains (superoxide dismutase (sod) single, double and triple mutants and a respective wild-type strain), transformed with luxCDABE genes responding to toxic compounds by decreasing their luminescence; and (3) three strains in which bioluminescence is specifically induced by bioavailable metals (Cu, Zn and Ag). The applicability of this battery of tests in profiling oxidative potential of eNPs was evaluated on nTiO2, nCuO, nZnO and nAg (25, 30, 70 and <100 nm, respectively) NPs and fullerenes. As controls for the size or solubility, the bulk formulations (bTiO2, bCuO and bZnO) and soluble salts (ZnSO4, CuSO4 and AgNO3) were also analysed. Bacterial toxicity tests showed that nCuO was four-fold more toxic, and nAg was 15-fold more toxic to triple sod mutant than to wild type (2-h EC50 values were 8.1 and 2.0 mg Cu l−1, respectively, and 46 and 3.1 mg Ag l−1, respectively). Formation of ROS by nCuO and nAg was proved by superoxide anion-inducible strain. The metal sensor bacteria showed that the ROS formation by CuO NPs was caused by solubilised Cu ions, but in case of nAg, particles also had an effect. nZnO was remarkably more toxic to sod triple mutant than to wild type strain (2-h EC50 were 4.5 and 54 mg Zn l−1, respectively). Fullerenes inhibited the bioluminescence of sod triple mutant at 3,882 mg l−1 but had no effect on the wild-type strain even at 20,800 mg l−1. Nano and bTiO2 showed some effect on viability of bacteria only at high concentrations (>4,000 mg l−1) although nTiO2 (but not bTiO2) induced the bioluminescence of the superoxide anion sensing bacteria starting from 100 mg l−1. Thus, our innovative combined approach is expected to provide more consistent and informative data concerning the general toxicity, ROS-production potential and also solubilisation of metals in the case of metallic NPs.  相似文献   

4.
High-performance liquid chromatography (HPLC) to determine shikimic acid is used as a complementary tool to differentiate wine varieties. In order to correctly classify, measurement uncertainty of shikimic acid by HPLC in red wine was estimated considering the following components: uncertainty associated with the preparation of shikimic acid stock solution, uncertainty associated with quantification using a calibration curve, and uncertainty associated with precision. The most important contribution to total uncertainty was the method precision. The expanded uncertainty (U) for different wine varieties was between 2.6 and 8.5%. The method was applied to determine the concentration of shikimic acid in different emerging wine varieties cultivated in Chile, such as Carmenère, Shiraz, and Pinot Noir, comparing them with classical varieties, such as Cabernet Sauvignon and Merlot. Shiraz wines presented lower shikimic acid concentrations (between 27 and 86 mg L−1 with U (k=2) = 2.6%) than Cabernet Sauvignon wines (between 41 and 142 mg L−1 with U (k=2) = 8.1%), but their concentrations were higher than found in Merlot (from 9 to 41 mg L−1 with U (k=2) = 4.3%) and Carmenère wines (between 7 and 49 mg L−1 with U (k=2) = 5.8%). Pinot Noir was the variety with the lowest concentration of this acid (7–14 mg L−1 with U (k=2) = 8.5%). Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

5.
An anodic stripping voltammetric procedure for the determination of Cu(II) at an in situ-plated stannum film electrode (SnFE) was described. The results indicated that the SnFE had an attractive electroanalytical performance, with two distinct voltammetric stripping signals for copper and stannum, and showed the superior advantage for the determination of copper compared with the bismuth film electrode. Several experimental parameters were optimized. The SnFE exhibited highly linear behavior in the concentration range from 1.0 to 100.0 μg L−1 of Cu(II) (r = 0.994) with the detection limit of 0.61 μg L−1 (S/N = 3), and the relative standard deviation for a solution containing 40.0 μg L−1 Cu(II) was 2.2% (n = 8). The procedure has been successfully applied for the determination of Cu(II) in lake water sample.  相似文献   

6.
Neopterin is a valuable biomarker of cellular immunity associated with various pathological situations such as viral and bacterial infections, autoimmune, cardiovascular, neurodegenerative and malignant disorders. To produce specific antibodies against neopterin for a rapid multi-biomarker-based diagnosis, a novel hapten derivative was synthesized and attached to carrier proteins. The thoroughly characterized conjugates were used for immunization of BALB/c mice and rabbits. The produced monoclonal antibody reached in both direct and indirect enzyme-linked immunosorbent assay (ELISA) format LoD of 0.18 and 0.45 μg L−1, respectively, and was a superior immunoreagent for further biosensor developments with regard to assay sensitivity and material availability. The best polyclonal antibody was somewhat more sensitive in direct ELISA with LoD of 0.05 μg L−1. The optimized ELISA method was evaluated with blood samples collected from patients with renal insufficiency, patients with sepsis, patients without confirmed clinical diagnosis, and healthy volunteers. In plasma samples, neopterin concentrations ranging from 3.2 to 103 μg L−1 could be determined with the monoclonal ELISA whereas twofold lower results were obtained with the polyclonal ELISA. A satisfactory correlation of results was found between the polyclonal ELISA and IBL Neopterin ELISA kit within the concentration range 0.5–16 μg L−1 (R = 0.874; n = 40), and slightly lower correlation was found for monoclonal-based ELISA (R = 0.819; n = 40). These data show that the generated antibodies may be used as functional analytical reagents for the integration into multianalyte biochip detection systems.  相似文献   

7.
This study describes the design and optimisation of a field flow system for the in-situ collection and on-line determination of phosphate, nitrate and nitrite by flow injection analysis-spectrophotometry. The method is based on the initial determination of phosphate as its phosphoantimonylmolybdenum blue complex which is then oxidized on-line by nitrite and the decrease in absorbance is monitored at 880 nm. Nitrate is determined as the difference between total and initial nitrite content in a separate flow after reduction to nitrite in a cadmium reductive column. The calibration curves were linear in the range 0–2.00 mg L−1 P-phosphate, 0–10.00 mg L−1 nitrite and 0–7.00 mg L−1 nitrate with correlation coefficients of 0.9979, 0.9993 and 0.9995, respectively. The detection limits, calculated as 3S/N, were 0.15 mg L−1 for P-phosphate, 0.17 mg L−1 for nitrite and 0.09 mg L−1 for nitrate. The reproducibility was below 3.0% (n = 7). Method validation in the analysis of natural water and wastewater samples revealed that it can efficiently be applied to the determination of the target analytes, with recoveries in the range of 92–108%. Correspondence: Athanasios G. Vlessidis, Laboratory of Analytical Chemistry, Department of Chemistry, University of Ioannina, Ioannina 45110, Greece  相似文献   

8.
This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h−1. Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 μL s−1. For a concentration range between 0.010 and 0.25 mg L−1, the current (i p, μA) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L−1): i p = (−20.5 ± 0.3)C paraquat − (0.02 ± 0.03). The limits of detection and quantification were 2.0 and 7.0 μg L−1, respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.  相似文献   

9.
Ethylene glycol monobutyl ether (EGBE), an industrial solvent, is absorbed by the body not only by inhalation but also by dermal absorption (liquid or vapour). EGBE is metabolized to butoxyacetic acid (BAA). Pooled freeze-dried urine candidate reference material (RM) was prepared from urine obtained from persons occupationally exposed to EGBE. This material has the advantage of containing butoxyacetic acid in both the free and conjugated (glutamine and glycine) forms, as found in native urine. In all GC method modifications used, acid hydrolysis was used to release BAA from its conjugated form. The amount of butoxyacetic acid in homogeneity and stability testing was measured by GC after derivatisation with N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide. Detection was by MS in EI mode, in the authors’ laboratory. For interlaboratory comparison of the reference material GC methods with MS, FID, and ECD were used. Different extraction solvents (dichloromethane–isopropanol 2:1, ethyl acetate, or dichloromethane) and derivatisation reagents (trimethylsilyldiazomethane, N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide) were used. Using ANOVA (at the statistical level α = 0.05) no changes were found in the concentration of butoxyacetic acid during fifteen month isochronous stability testing, or in homogeneity testing. The uncertainty contributions were u h = 8.8 mg L−1 and u s = 6.5 mg L−1. The concentration of butoxyacetic acid in freeze-dried urine RM was evaluated from the results of eight laboratory data sets within an interlaboratory comparison by use of the interactive statistical software IPECA. The contribution to total uncertainty derived from interlaboratory comparison was u i = 12.7 mg L−1. The reference value (c = 273 ± 33 mg L−1) is an unweighted arithmetic average of accepted results. The value is traceable to the pure butoxyacetic acid (98% w/w; Acros Organic #257760010) used as calibrant. The uncertainty given is combined expanded uncertainty derived from the results from interlaboratory comparison, and from homogeneity and stability tests (k = 2). The reference material will be used to verify method performance in the biological monitoring of occupational exposure to EGBE.  相似文献   

10.
This article describes a robust methodology using the combination of instrumental design (high matrix interface—HMI), sample dilution and internal standardization for the quantification of beryllium (Be) in various digested autopsy tissues using inductively coupled plasma mass spectrometry. The applicability of rhodium as a proper internal standard for Be was demonstrated in three types of biological matrices (i.e., femur, hair, lung tissues). Using HMI, it was possible to achieve instrumental detection limits and sensitivity of 0.6 ng L−1 and 157 cps L ng−1, respectively. Resilience to high salt matrices of the HMI setup was also highlighted using bone mimicking solution ([Ca2+] = 26 to 1,400 mg L−1), providing a 14-fold increase in tolerance and a 2.7-fold decrease in method detection limit compared to optimized experimental conditions obtained without the HMI configuration. Precision of the methodology to detect low levels of Be in autopsy samples was demonstrated using hair and blood certified reference materials. Be concentration ranging from 0.015 to 255 μg kg−1 in autopsy samples obtained from the U.S. Transuranium and Uranium Registries were measured using the methodology presented.  相似文献   

11.
In the Nawanshahr–Hoshiarpur region of Punjab, India, more than 1000 hectares of agricultural land is significantly affected by high levels of selenium (Se). Studies were carried out to examine Se levels in soil and crops such as wheat grains, wheat husk, rice, maize and mustard using neutron activation analysis. The Se concentrations in soil and crop products were found to be ranging from 2.7 to 6.5 mg kg−1 and 13 to 670 mg kg−1, respectively, indicating significantly high selenium in these crop products. Two reference materials were analysed for Se contents by INAA as controls.  相似文献   

12.
Nano zinc oxide (nZnO) is increasingly used in sunscreen products, with high potential of being released directly into marine environments. This study primarily aimed to characterize the aggregate size and solubility of nZnO and bulk ZnO, and to assess their toxicities towards five selected marine organisms. Chemical characterization showed that nZnO formed larger aggregates in seawater than ZnO, while nZnO had a higher solubility in seawater (3.7 mg L−1) than that of ZnO (1.6 mg L−1). Acute tests were conducted using the marine diatoms Skeletonema costatum and Thalassiosia pseudonana, the crustaceans Tigriopus japonicus and Elasmopus rapax, and the medaka fish Oryzias melastigma. In general, nZnO was more toxic towards algae than ZnO, but relatively less toxic towards crustaceans and fish. The toxicity of nZnO could be mainly attributed to dissolved Zn2+ ions. Furthermore, molecular biomarkers including superoxide dismutase (SOD), metallothionein (MT) and heat shock protein 70 (HSP70) were employed to assess the sublethal toxicities of the test chemicals to O. melastigma. Although SOD and MT expressions were not significantly increased in nZnO-treated medaka compared to the controls, exposure to ZnO caused a significant up-regulation of SOD and MT. HSP70 was increased two to fourfold in all treatments indicating that there were probably other forms of stress in additional to oxidative stress such as cellular injury.  相似文献   

13.
A fed-batch culture system with constant feeding (glucose 80 g L−1, 0.25 ml min−1) was used to study the influence of glucose on cell dry weight and exopolysaccharides production from submerged Tremella fuciformis spores in a 5-L stirred-tank bioreactor. The results showed that high levels of cell mass (9.80 g L−1) and exopolysaccharides production (3.12 g L−1) in fed-batch fermentation were obtained after 1 h of feeding, where the specific growth rate (μ) and exopolysaccharides yield on substrate consumed (YP/S) were 0.267 d−1 and 0.14 g g−1. Unlike batch fermentation, maximal cell mass and exopolysaccharides production merely reached 7.11 and 2.08 g L−1; the specific growth rate (μ) and exopolysaccharides yield on substrate consumed (YP/S) were 0.194 d−1 and 0.093 g g−1, respectively. It is concluded that the synthesis of exopolysaccharides can be promoted effectively when feeding glucose at a late exponential phase.  相似文献   

14.
To screen strains of halotolerant or halophile bacteria which are able to convert isoeugenol to vanillin, 36 different strains of bacteria isolated from the salty environments in Iran were investigated. During growth on isoeugenol, a moderately halotolerant Gram-negative coccobacil showed capability of converting isoeugenol to vanillin. Based on morphological, physiological, and phylogenetic studies, strain CSW4 was classified as a bacterium belonging to the genus Psychrobacter. The bioconversion products were confirmed by thin-layer chromatography, high-performance liquid chromatography, and spectral data obtained from UV/Vis spectroscopy, FTIR, and mass-spectroscopy. Using growing cells, vanillin reached its maximum level of 88.18 mg L−1 after 24 h of reaction time in the presence of 1 g L−1 isoeugenol, resulting in a molar yield of 10.2%. The use of resting cells led to the optimal yield of vanillin (16.4%) which was obtained after 18-h reaction using 1 g L−1 isoeugenol and 3.1 g of dry weight of cells per liter harvested at the end of the exponential growth phase. To improve vanillin yield, the effect of substrate concentration on vanillin production under resting cells conditions was also investigated. Using 10 g L−1 isoeugenol, the maximal vanillin concentration (1.28 g L−1) was achieved after a 48-h reaction, without further optimization. The present study brings the first evidence for biotransformation of isoeugenol to vanillin in the genus Psychrobacter.  相似文献   

15.
This study was conducted to investigate the effect of a photocatalysis/oxidant system for the treatment of humic acid and hazardous heavy metals in aqueous solutions. Hydrogen peroxide, ozone, and potassium peroxodisulfate were tested as oxidants. The effect of oxidant concentration was conducted with a pH of 7, a UV intensity of 64 W, and a TiO2 dosage of 0.3 g L−1. The oxidant addition in the UV/TiO2 system enhanced the degradation efficiency of humic acid and hazardous heavy metals compared to no addition of an oxidant. The addition of oxidants over the amounts of H2O2 50 mg L−1, O3 20 g m−3, and K2S2O8 50 mg L−1 inhibits the system efficiency. The negative effect of higher oxidant concentrations likely results from OH radical quenching caused by the excess oxidant. Therefore, the optimal dosages of oxidants such as a hydrogen peroxide, ozone, and potassium peroxodisulfate were found to be 50 mg L−1, 20 g m−3, and 50 mg L−1, respectively. The degradation efficiency of UV/TiO2/oxidant systems for the removal of humic acid and hazardous heavy metals was much greater in the UV/TiO2/H2O2 system using H2O2 as an oxidant.  相似文献   

16.
Stir-bar-sorptive extraction (SBSE) with liquid desorption (LD) and ultra-high-performance liquid chromatography–electrospray ionization triple-quadrupole tandem mass spectrometry (UHPLC–(ESI)MS–MS) were used for analysis of six personal care products in environmental water: four UV filters (2,2-dihydroxy-4-methoxybenzophenone, benzophenone-3, octocrylene, and octyldimethyl-p-aminobenzoic acid) and two antimicrobial agents (triclocarban and triclosan). Experimental conditions that affect SBSE-LD sorption efficiency (extraction time and temperature, sample pH, and ionic strength) and desorption efficiency (solvent, temperature, and time) were optimized. The method proved to be sensitive—a 50-mL sample was used to determine these compounds in environmental waters at trace levels. The detection limits of the analytical method were 2.5 ng L−1 for river water and 5–10 ng L−1 for effluent and influent sewage water. In river waters, benzophenone-3 was found at levels from 6 ng L−1 to 28 ng L−1 and triclosan at levels <LOQ. Benzophenone-3 was found between 75 and 127 ng L−1 in influent sewage, whereas concentrations of benzophenone-3 and triclosan were commonly below 25 ng L−1 in effluent sewage.  相似文献   

17.
A new method is proposed using a microcolumn (20 mm × 2.0 mm) packed with nanometer-sized zirconia as solid-phase extractor for the separation/preconcentration of Mn, Cu, Cr, Zn, Ni and Co prior to their determination by inductively coupled plasma optical emission spectrometer (ICP-OES) in environmental samples. The factors affecting the separation and preconcentration of analytes such as pH, sample flow rate and volume, eluent concentration and volume were determined, interfering ions were studied, and the optimal experimental conditions were established. The adsorption capacity of nanometer-sized ZrO2 for Mn, Cu, Cr, Zn, Ni and Co was found to be 1.3, 1.3, 1.7, 2.0, 3.9 and 1.5 mg g−1, respectively. The detection limits of the method were 12, 58, 24, 2, 7 and 36 ng L−1, respectively, with a preconcentration factor of 25. The precision of this method was 1.7% (Mn), 2.9% (Cu), 5.9% (Mn), 3.8% (Mn), 6.2% (Mn) and 4.3% (Mn) with 9 determinations of 10 ng mL−1 of target analytes, respectively. The method was successfully applied to the determination of trace metals in lake water, dried fish samples, certified reference materials of human hair and milk, and provided satisfactory results.  相似文献   

18.
The adsorption process of 3-chloro phenol from aqueous solution on a activated carbon prepared from African palm stone and which presents a specific surface area of 685 m2 g−1, a greater quantity of total acid groups and a pHPZC of 6.8 is studied. The adsorption isotherms are determined at pH values of 3, 5, 7, 9 and 11. The adsorption isotherms are fitted to the Langmuir model and the values of the maximum quantity adsorbed that are between 96.2 and 46.4 mg g−1 are obtained along with the constant KL with values between 0.422 and 0.965 L mg−1. The maximum quantity adsorbed diminishes with the pH and the maximum value for this is a pH of 5. The immersion enthalpies of the activated carbon in a 3-chloro phenol solution of constant concentration, of 100 mg L−1, are determined for the different pH levels, with results between 37.6 and 21.2 J g−1. Immersion enthalpies of the activated carbon in function of 3-chloro phenol solution concentration are determined to pH 5, of maximum adsorption, with values between 28.3 and 38.4 J g−1, and by means of linearization, the maximum immersion enthalpy is calculated, with a value of 41.67 J g−1. With the results of the immersion enthalpy, maximum quantity adsorbed and the constant KL, establish relations that describe the adsorption process of 3-chloro phenol from aqueous solution on activated carbon.  相似文献   

19.
In this work, the potential of microwave-assisted alkali pretreatment in order to improve the rupture of the recalcitrant structures of the cashew able bagasse (CAB), lignocellulosic by-product in Brazil with no commercial value, is obtained from cashew apple process to juice production, was studied. First, biomass composition of CAB was determined, and the percentage of glucan and lignin was 20.54 ± 0.70% and 33.80 ± 1.30%, respectively. CAB content in terms of cellulose, hemicelluloses, and lignin, 19.21 ± 0.35%, 12.05 ± 0.37%, and 38.11 ± 0.08%, respectively, was also determined. Results showed that, after enzymatic hydrolysis, alkali concentration exerted influence on glucose formation, after pretreatment with 0.2 and 1.0 mo L−1 of NaOH (372 ± 12 and 355 ± 37 mg gglucan−1) when 2% (w/v) of cashew apple bagasse pretreated by microwave-assisted alkali pretreatment (CAB-M) was used. On the other hand, pretreatment time (15–30 min) and microwave power (600–900 W) exerted no significant effect on hydrolysis. On enzymatic hydrolysis step, improvement on solid percentage (16% w/v) and enzyme load (30 FPU gCAB-M−1) increased glucose concentration to 15 g L−1. The fermentation of the hydrolyzate by Saccharomyces cerevesiae resulted in ethanol concentration and productivity of 5.6 g L−1 and 1.41 g L−1 h−1, respectively.  相似文献   

20.
A new adsorbent is proposed for the solid-phase extraction of phenol and 1-naphthol from polluted water. The adsorbent (TX-SiO2) is an organosilica composite made from a bifunctional immobilized layer comprising a major fraction (91%) of hydrophilic diol groups and minor fraction (9%) of the amphiphilic long-chain nonionic surfactant Triton X-100 (polyoxyethylated isooctylphenol) (TX). Under static conditions phenol was quantitatively extracted onto TX-SiO2 in the form of a 4-nitrophenylazophenolate ion associate with cetyltrimethylammonium bromide. The capacity of TX-SiO2 for phenol is 2.4 mg g−1 with distribution coefficients up to 3.4 × 104 mL g−1; corresponding data for 1-naphthol are 1.5 mg g−1 and 3 × 103 mL g−1. The distribution coefficient does not change significantly for solution volumes of 0.025–0.5 L and adsorbent mass less than 0.03 g; 1–90 μg analyte can be easily eluted by 1–3 mL acetonitrile with an overall recovery of 98.2% and 78.3% for phenol and 1-naphthol, respectively. Linear correlation between acetonitrile solution absorbance (A 540) and phenol concentration (C) in water was found according to the equation A 540 = (6 ± 1) × 10−2 + (0.9 ± 0.1)C (μmol L−1) with a detection range from 1 × 10−8 mol L−1 (0.9 μL g−1) to 2 × 10−7 mol L−1 (19 μL g−1), a limit of quantification of 1 μL g−1 (preconcentration factor 125), correlation coefficient of 0.936, and relative standard deviation of 2.5%. A solid-phase colorimetric method was developed for quantitative determination of 1-naphthol on adsorbent phase using scanner technology and RGB numerical analysis. The detection limit of 1-naphthol with this method is 6 μL g−1 while the quantification limit is 20 μL g−1. A test system was developed for naked eye monitoring of 1-naphthol impurities in water. The proposed test kit allows one to observe changes in the adsorbent color when 1-naphthol concentration in water is 0.08–3.2 mL g−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号