首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, sensitive, stability-indicating HPLC method was developed and validated for the quantitative determination of the vasoprotective drug, naftazone in presence of its degradation products. The analysis was carried out on a Nucleosil 100-5 phenyl column (250 mm × 4.6 mm, 5 μm) using a mobile phase consisting of methanol-0.02 M sodium dihydrogen phosphate mixture (60:40, v/v) of pH 6.0. The analyses were performed at ambient temperature with a flow rate of 1.0 mL/min and UV detection at 270 nm. The method showed good linearity over the concentration range of 0.1-10.0 μg/mL with a lower detection limit of 0.032 and quantification limit of 0.096 μg/mL. The suggested method was successfully applied for the analysis of naftazone in its commercial tablets. Moreover, it was utilized to investigate the kinetics of alkaline, acidic and oxidative degradation of the drug. The apparent first-order rate constants, half-life times, and activation energies of the degradation process were calculated. The pH-rate profile curve was derived. Furthermore, the proposed method was successfully applied to the content uniformity testing of naftazone tablets.  相似文献   

2.
A reversed-phase high-performance liquid chromatographic method is developed and validated for the quantitative determination of talinolol and to characterize its degradation products. A very good resolution between peaks is achieved using a C18 column at 40°C. The mobile phase comprises of a mixture of acetonitrile and potassium dihydrogen orthophosphate buffer (pH 4.4) in the ratio of 27:73 (v/v). The method is validated with respect to linearity, accuracy, precision, robustness, and forced degradation studies, which further proved the stability indicating power. During the forced degradation studies, talinolol is observed to be labile to hydrolytic stress and thermal stress (in the solution form). However, it is stable to the oxidative, photolytic, and thermal stress (in the solid form). The degraded products formed are investigated by electrospray ionization (ESI), time-of-flight mass spectrometry, nuclear magnetic resonance, and infrared spectroscopy. A possible degradation pathway is outlined based on the results. The method is found to be sensitive with a detection limit of 0.125 μg/mL and a quantitation limit of 0.378 μg/mL. The method is also demonstrated to be robust, as it is resistant to small variations of chromatographic variables such as pH, mobile phase composition, flow rate, and column temperature.  相似文献   

3.
A selective reversed-phase (RP) liquid chromatographic (LC) method coupled with UV for the determination of tylosin and its related substances is described. The gradient method uses a Capcell pak C18 ACR column (25 cm×4.6 mm id, 5 μm) maintained at a temperature of 60°C. The mobile phases consist of acetonitrile, phosphate buffer pH 5.5 and water: (A; 27.5:10:62.5 v/v/v) and (B; 50:10:40 v/v/v). The flow rate is 1.0 mL/min and UV detection is performed at 280 nm. It allows the separation of all known and 22 other unknown related substances (≥0.02%) from the main compound and from one another. The method shows good precision, sensitivity, linearity (between 0.2 μg/mL and 1.25 mg/mL) and robustness. The limit of quantification is 0.2 μg/mL, corresponding to 0.020%. Seven bulk tylosin samples containing a large number of impurities were examined using this method.  相似文献   

4.
A reversed-phase liquid chromatography (RP-LC) method is validated for the determination of aliskiren in tablet dosage form. The LC method is carried out on a Waters XBridge C(18) column (150 × 4.6 mm i.d.), maintained at 25°C. The mobile phase consisted of acetonitrile:water (95:5, v/v)/phosphoric acid (25 mM, pH 3.0) (40:60, v/v), run at a flow rate of 1.0 mL/min, with photodiode array detector set at 229 nm. The chromatographic separation is obtained with aliskiren retention time of 3.68 min, and it is linear in the range of 10-300 μg/mL (r = 0.9999). The limits of detection and quantitation are 2.38 and 7.93 μg/mL, respectively. The specificity and stability-indicating capability of the method are proven through degradation studies, which also showed that there is no interference of the formulation excipients, showing that peak is free from any coeluting peak. The method showed adequate precision, with a relative standard deviation (RSD) values lower than 0.92%. Good values of accuracy were also obtained, with a mean value of 99.55%. Experimental design is used during validation to calculate method robustness. The proposed method is applied for the analysis of the tablet dosage forms, contributing to improve the quality control and to assure the therapeutic efficacy.  相似文献   

5.
A novel, stability-indicating gradient reverse-phase ultra-performance liquid chromatographic method was developed for the simultaneous determination of ibuprofen and diphenhydramine citrate in the presence of degradation products and process related impurities in combined dosage form. The method was developed using C18 column with mobile phase containing a gradient mixture of solvent A and B. The eluted compounds were monitored at 220 nm. Ibuprofen and diphenhydramine citrate were subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, and photolytic degradation. Major unknown impurity formed under oxidative degradation was identified using LC-MS-MS study. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantitation, accuracy, precision and robustness. The described method was linear over the range of 0.20-6.00 μg/mL (r>0.998) for Ibuprofen and 0.084-1.14 μg/mL for diphenhydramine citrate (r>0.998). The limit of detection results were ranged from 0.200-0.320 μg/mL for ibuprofen impurities and 0.084-0.099 μg/mL for diphenhydramine citrate impurities. The limit of quantitation results were ranged from 0.440 to 0.880 μg/mL for ibuprofen impurities and 0.258 to 0.372 μg/mL for diphenhydramine citrate impurities. The recovery of ibuprofen impurities were ranged from 98.1% to 100.5% and the recovery of diphenhydramine citrate impurities were ranged from 97.5% to 102.1%. This method is also suitable for the simultaneous assay determination of ibuprofen and diphenhydramine citrate in pharmaceutical dosage forms.  相似文献   

6.
An isocratic reversed-phase high-performance liquid chromatographic method for the estimation of permethrin in raw materials and pharmaceutical topical preparations has been devised and validated. The chromatographic analysis was performed on a 5 μm particle C-18 Nucleosil (Macherey-Nagel, Germany) column (250 × 4.6 mm). Mobile phase consisted of methanol and 0.025 mM Phosphoric acid (85:15 v/v) at a flow rate of 1.5 mL/min. UV detection was performed at 272 nm and peaks were identified with retention times as compared with standards. The limit of detection was 1.782 μg/mL, while limit of quantitation was 48.0 μg/mL. The calibration was linear in a concentration range of 48.0-5000 μg/mL with correlation coefficient of 0.999978. Regression equation was absorbance =2833.23 × concentration(μg/mL) + 19.1045 with variance of the response variable, S(yx)(2), calculated to be 1.75328 (six degrees of freedom). The method was validated as per ICH guidelines and USP requirements and found advantageous for the routine analysis of the drug in pharmaceutical formulations and in pharmaceutical investigations involving permethrin.  相似文献   

7.
A simple, sensitive, and accurate stability‐indicating analytical method has been developed and validated using ultra high performance liquid chromatography. The developed method is used to evaluate the related substances of eplerenone (EP). The degradation behavior of EP under stress conditions was determined, and the major degradants were identified by ultra high performance liquid chromatography with tandem mass spectrometry. The chromatographic conditions were optimized using an impurity‐spiked solution, and the samples, generated from forced degradation studies. The resolution of EP, its potential impurities, and its degradation products was performed on a Waters UPLC BEH C18 column (50 × 2.1 mm, 1.7 μm) by linear gradient elution using a mobile phase consisting of 10 mmol/L ammonium acetate adjusted to pH 4.5, methanol and acetonitrile. A photo‐diode array detector set at 245 nm was used for detection. The flow rate was set at 0.3 mL/min. The procedure had good specificity, linearity (0.02–3.14 μg/mL), recovery (96.1–103.9%), limit of detection (0.01–0.02 μg/mL), limit of quantitation (0.03–0.05 μg/mL), and robustness. The correction factors of the process‐related substances were calculated.  相似文献   

8.
A stability-indicating liquid chromatographic method has been developed for the quantitative determination of lodenafil carbonate in tablets. The method employs a Synergi Fusion C18 column (250 × 4.6 mm, i.d., 4 μm particle size), with mobile phase consisting of a mixture of methanol-acetic acid 0.1% pH 4.0 (65:35, v/v) and UV detection at 290 nm, using a photodiode array detector. A linear response (r = 0.9999) was observed in the range of 10-80 μg/mL. The method showed good recoveries (average 100.3%) and also intra and inter-day precision (RSD < 2.0%). Validation parameters as specificity and robustness were also determined. Specificity analysis showed that no impurities or degradation products were co-eluting with the lodenafil carbonate peak. The method was found to be stability-indicating and due to its simplicity and accuracy can be applied for routine quality control analysis of lodenafil carbonate in tablets.  相似文献   

9.
ABSTRACT: A simple reversed phase high performance liquid chromatographic method with diode array detector (HPLC-DAD) has been developed and subsequently validated for the determination of fexofenadine hydrochloride (FEX) and its related compounds; keto fexofenadine (Impurity A), meta isomer of fexofenadine (Impurity B), methyl ester of fexofenadine (Impurity C) in addition to the methyl ester of ketofexofenadine (Impurity D). The separation was based on the use of a Hypersil BDS C-18 analytical column (250 × 4.6 mm, i.d., 5 μm). The mobile phase consisted of a mixture of phosphate buffer containing 0.1 gm% of 1-octane sulphonic acid sodium salt monohydrate and 1% (v/v) of triethylamine, pH 2.7 and methanol (60:40, v/v). The separation was carried out at ambient temperature with a flow rate of 1.5 ml/min. Quantitation was achieved with UV detection at 215 nm using lisinopril as internal standard, with linear calibration curves at concentration ranges 0.1-50 μg/ml for FEX and its related compounds. The optimized conditions were used to develop a stability-indicating HPLC-DAD method for the quantitative determination of FEX and its related compounds in tablet dosage forms. The drugs were subjected to oxidation, hydrolysis, photolysis and heat to apply stress conditions. Complete separation was achieved for the parent compounds and all degradation products. The method was validated according to ICH guidelines in terms of accuracy, precision, robustness, limits of detection and quantitation and other aspects of analytical validation.  相似文献   

10.
We present a selective method for simultaneous determination of five polyether ionophores such as salinomycin (SAL), monensin (MON), narasin (NAR), semduramicin (SEM) and lasalocid (LAS) in aquatic samples using a liquid chromatography with one-step fluorescent derivatization of 2-(4-hydrazinocarbonyl-phenyl) 4,5-diphenylimidazole (HCPI) and 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride hydrochloride (DIB-Cl). Fluorescent one-step derivatization for SAL, MON, NAR and SEM using HCPI and for LAS using DIB-Cl was monitored by an LC/fluorescence detector (E(x), 340 nm; E(m), 465 nm). Chromatographic separation was performed on a TSK-GEL ODS-120T (4.6 × 150 mm, 3 μm) column using a mobile phase of 0.1% formic acid in acetonitrile and 0.5 mM ammonium formate in water (70/30, v/v). The limits of detections were 0.01 μg/mL (50 pg) for LAS, 0.05 μg/mL (250 pg) for SAL, NAR and SEM, and 0.1 μg/mL (500 pg) for MON, respectively. The recoveries for water samples were indicated to be the range of 79.6 ± 6.4 - 99.0 ± 4.4% with associated precision values (between-day for 3 days) for repeatability. Based on solid-phase extraction, the limit of quantitation values indicated 0.1 ng/mL for SAL, MON, NAR and SEM, and 0.01 ng/mL for LAS in water samples.  相似文献   

11.
刘茜  刘晓宇  邱朝坤  王小宝  任红敏 《色谱》2009,27(4):476-479
建立了鲫鱼肌肉中残留的辛硫磷的基质固相分散-高效液相色谱-二极管阵列检测(MSPD-HPLC-DAD)的分析方法。通过优化样品处理条件,确定选取0.50 g鲫鱼肌肉样品与1.5 g弗罗里硅土、0.5 g无水硫酸钠混合研磨,并采用丙酮-正己烷溶液(体积比为40:60)为洗脱剂,洗脱剂用量为25 mL。优选的最佳色谱条件为:ODS色谱柱(250 mm×4.6 mm,5 μm),流动相为甲醇-水(体积比为50:50),流速0.6 mL/min,检测波长270 nm,进样量为20 μL。在上述条件下,辛硫磷质量浓度在0.01~10 mg/L范围内与响应信号呈良好的线性关系(r20.9994),检出限为3.3 μg/kg;相对标准偏差为1.1%~6.3%(n7);3个添加水平(0.05,0.1,1 mg/kg)下得到的回收率为88%~112%。该方法操作简单,耗时少,精密度高,符合农残分析的要求。  相似文献   

12.
The present study describes the development and validation of a selective liquid chromatographic (LC) method for the analysis of tenofovir disoproxil fumarate (TDF) and its related substances. The gradient method uses a base deactivated C18 column (Hypersil BDS column; 25 cm×4.6 mm I.D.) maintained at a temperature of 30°C. The mobile phases consist of acetonitrile, tetrabutylammonium/phosphate buffer pH 6.0 and water: (A; 2:20:78 v/v/v) and (B; 65:20:15 v/v/v). The flow rate is 1.0 mL/min and UV detection is performed at 260 nm. Good separation of TDF and 21 impurities was achieved. A system suitability test (SST) to check the quality of separation is also specified. The developed method was further validated with respect to robustness, precision, sensitivity and linearity. The method is proved to be robust, precise, sensitive and linear between 0.1 μg/mL and 0.15 mg/mL. The limit of detection and limit of quantification are 0.03 and 0.1 μg/mL, respectively. The method was successfully applied to the quantification of related substances and assay of commercial TDF samples (bulk substances and tablets).  相似文献   

13.
Primary objective of this study was to develop a stability-indicating reverse-phase high-performance liquid chromatography (HPLC) method for simultaneous quantitation of tramadol and aceclofenac in presence of their degradation products. The drugs were subjected to various International Conference on Harmonization recommended stress conditions, such as acid hydrolysis, alkaline hydrolysis, peroxide oxidation, thermolysis, and photolysis. The major degradation products got well resoluted from the analytes in HPLC analysis with a mobile phase composed of a mixture of 0.01?M ammonium acetate buffer (pH 6.5) and acetonitrile (65:35, v/v) through a Phenomenex Gemini C18 (250?mm?×?4.6?mm, 5?µm particle size) column. The method was linear over a range of 15–60?µg/mL for tramadol and 40–160?µg/mL for aceclofenac concentration. The analytes were detected at a wavelength of 270?nm. The method was validated and found to be specific, accurate, precise, stable, and robust for its intended use. The method can be recommended for its future use in routine quality control, accelerated and real-time stability analysis of the formulations containing tramadol and aceclofenac combination.  相似文献   

14.
A high‐performance liquid chromatographic (HPLC) method was developed for the analysis of the stilbene, oxyresveratrol. This method involves the use of a Luna® C18 column with ultraviolet detection at 320 nm. The mobile phase consisted of acetonitrile, water and formic acid (30 : 70 : 0.04 v/v) with a flow rate of 0.6 mL/min. The calibration curves were linear over the range of 0.5–100.0 μg/mL. The mean extraction efficiency was between 98.9 and 109%. The precision of the assay was 0.069–18.4% (RSD%), and within 20% at the limit of quantitation (0.5 μg/mL). The bias of the assay was <15% and within 15% at the limit of quantitation. This assay was successfully applied to pre‐clinical pharmacokinetic samples from rat urine and to nutraceutical product analysis. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
Two simple, specific, sensitive, accurate and precise stability indicating methods were described for quantitative determination of the anthelmintics drug Niclosamide. The first method was high performance liquid chromatographic with the use of a reversed phase hibarR C-18 column (250 mm × 4.66 mm, 5 μm) and mobile phase of methanol: 1 mM ammonium phosphate buffer (85:15 v/v) at a flow rate of 1.2 mL/min. The retention time of drug was found to be 6.45 ± 0.02 min. Quantification of drug was achieved with diode array detection (DAD) at 332 nm. Linear calibration curve was obtained in concentration range 0.01–100 μg/mL with r2 value of 0.999. The limit of detection and limit of quantification were found to be 0.048 μg/mL and 0.01 μg/ml respectively. The second method involved a high performance thin layer liquid chromatographic. Chromatographic separation was carried out with precoated silica gel G60 F254 aluminum sheets using toluene:ethyl acetate (7:3% v/v) as a mobile phase. Linearity of proposed method was found to be 200–700 ng/band at 332 nm with retention factor of 0.59 and r2 value of 0.998. The limit of detection and limit of quantification were found to be 36.21 ng/band and 109.7 ng/band respectively. Both the developed methods were successfully validated as per International Conference on Harmonization guideline (ICH). Niclosamide was subjected to different stress conditions. The degraded product peaks were well resolved from the pure drug peak with significant difference in their retention time. Stress samples were successfully assayed by developed high performance liquid chromatographic and high performance thin layer liquid chromatographic method. Statistically analysis proves that there were no statistical significant differences between two developed methods.  相似文献   

16.
建立超高效液相色谱法快速检测虾青素的方法。采用UPLC BEH C_8色谱柱(50 mm×2.1 mm,1.7μm),考察了流动相、流量及柱温对虾青素样品分离的影响,确定了最佳色谱条件:等度洗脱,流动相为甲醇–水(体积比为75∶25),流量为0.5 mL/min,柱温为40℃,检测波长为475 nm。虾青素的质量浓度在0.2~10.0μg/mL范围内与其色谱峰面积呈良好的线性关系,线性相关系数r=0.998 8,检出限(S/N=3)为0.1μg/mL,定量限(S/N=10)为0.2μg/mL。测定结果的相对标准偏差为0.41%(n=6),加标回收率为105.8%~110.3%。该方法快速、简单、可靠、灵敏、重复性好,可用于虾青素有关样品的快速检测。  相似文献   

17.
Two selective and accurate chromatographic methods are presented for simultaneous quantitation of spironolactone (SP) and furosemide (FR) and canrenone (CN), the main degradation product and the main active metabolite of SP. Method A was HPTLC, where separation was completed on silica gel HPTLC F254 plates using ethyl acetate–triethylamine–acetic acid (9:0.7:0.5, by volume) as a developing system and UV detection at 254 nm. Method B was a green isocratic RP‐HPLC utilizing a C18 (4.6 × 100 mm) column, the mobile phase consisting of ethanol–deionized water (45: 55, v/v) and UV estimation at 254 nm. Adjustment of flow rate at 1 mL/min and pH at 3.5 with glacial acetic acid was done. Regarding the greenness profile, the proposed RP‐HPLC method is greener than the reported one. ICH guidelines were followed to validate the developed methods. Successful applications of the developed methods were revealed by simultaneous determination of FR, SP and CN in pure forms and plasma samples in the ranges of 0.2–2, 0.05–2.6 and 0.05–2 μg/band for method A and 5–60, 2–60 and 2–60 μg/mL for method B for FR, SP and CN, respectively.  相似文献   

18.
A new and simple isocratic high-performance liquid chromatographic method with ultraviolet detection is described for simultaneous determination of active guaiphenesin and preservative sodium benzoate in Liqufruta garlic cough medicine formulation. The chromatographic separation was achieved using a Zorbax CN; 150 mm × 4.6 mm and 5 μm particle size column employing acetonitrile and water (20: 80, v/v) containing 0.1% formic acid (pH 3.5 ± 0.05) as the mobile phase. The method was validated with respect to linearity, range, precision, accuracy, specificity, limit of detection and limit of quantitation. The both analytes were detected by UV-Vis detector at 245 nm. The method was linear over the concentration range of 0.2–0.8 mg/mL and 0.02–0.06 mg/mL for guaiphenesin and sodium benzoate, respectively. The limit of detection was found to be 0.14 μg/mL for GP and 0.06 μg/mL for SB and the quantification limit was 0.54 μg/mL for GP and 0.22 for SB. Accuracy, evaluated as recovery, was in the range of 97.8–100.0%. Intra-day precision and intermediate precision showed relative standard deviation <1% in each case.  相似文献   

19.
A stability-indicating reversed-phase liquid chromatography (RP-LC) method was validated for the assessment of recombinant human interleukin-11 (rhIL-11), based on the ICH guidelines. The method was carried out on a Jupiter C(4) column (250 mm × 4.6 mm i.d.), maintained at 25°C. The mobile phase A consisted of 0.1% trifluoroacetic acid (TFA) and the mobile phase B was acetonitrile with 0.1% TFA, run at a flow rate of 1 mL/min, and using a photodiode array (PDA) detection at 214 nm. Separation was obtained with a retention time of 27.6 min, and was linear over the concentration range of 1-200 μg/mL (r(2) = 0.9995). Specificity was established in degradation studies, which also showed that there was no interference of the excipients. The accuracy was 100.22% with bias lower than 1.25%. Moreover, the in vitro cytotoxicity test of the degraded products showed non-significant differences (p > 0.05). The method was applied to the assessment of rhIL-11 and related proteins in biopharmaceutical dosage forms, and the results were correlated to those of a bioassay.  相似文献   

20.
建立奥曲肽的高效液相色谱定量分析方法。色谱柱为Eclipse plus C18柱(4.6 mm×250 mm,5 μm),流动相为乙腈-0.25%高氯酸水溶液(体积比为30∶70),流量为1.0 mL/min,检测波长为210 nm,柱温为25℃。奥曲肽的质量浓度在4.38~219 μg/mL范围内与色谱峰面积成良好的线性关系,相关系数为0.9999,检出限为1.1 ng,定量限为2.19 ng。测定结果的相对标准偏差为0.26%~0.46% (n=5),加标回收率为97.41%~100.26%。该方法简便、快速、准确,适用于奥曲肽原料药与制剂的定量分析。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号