首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
毛细管电泳安培检测技术进展   总被引:1,自引:0,他引:1  
对毛细管电泳离柱和柱端安培检测方式、不同形式电极在安培检测中的应用、安培检测在芯片毛细管电泳中的应用、安培检测池等内容进行了总结和讨论 ,并预测了安培检测技术未来发展方向  相似文献   

2.
毛细管电泳-柱端电化学检测池的设计   总被引:4,自引:0,他引:4  
吴性良  方爱萍  张祥民 《色谱》1999,17(2):190-192
在射壁式检测器的基规上,设计了一种用于毛细管电泳-电化学检测装置的检测池,巧妙地利用因表面张力现象而留驻波滴曲面的放大作用,直接调整毛细管与电极之间的相对位置,无需显微镜-微调节器装置,具有空间体积小,操作更简便的优点。  相似文献   

3.
The first reported use of a carbon paste electrochemical detector for microchip capillary electrophoresis (CE) is described. Poly(dimethylsiloxane) (PDMS)-based microchip CE devices were constructed by reversibly sealing a PDMS layer containing separation and injection channels to a separate PDMS layer that contained carbon paste working electrodes. End-channel amperometric detection with a single electrode was used to detect amino acids derivatized with naphthalene dicarboxaldehyde. Two electrodes were placed in series for dual electrode detection. This approach was demonstrated for the detection of copper(II) peptide complexes. A major advantage of carbon paste is that catalysts can be easily incorporated into the electrode. Carbon paste that was chemically modified with cobalt phthalocyanine was used for the detection of thiols following a CE separation. These devices illustrate the potential for an easily constructed microchip CE system with a carbon-based detector that exhibits adjustable selectivity.  相似文献   

4.
M Goto  S Inagaki  Y Esaka 《Analytical sciences》2001,17(12):1383-1387
A handy and simple detection cell was constructed using a mixing joint for end-column electrochemical detection in capillary electrophoresis (CE). The cell allows for positioning of the working electrode at the end of the separation capillary without the aid of micropositioners. The design facilitates the exchange of electrodes and capillaries without the need to refabricate the entire capillary-electrode setup. The cell can be assembled in a short period of time. Alignment with the joint screw proved to be reproducible for working electrodes of copper and gold. The advantages of reduced time and low cost make the device very attractive for the routine analysis of electroactive species, such as carbohydrates and their derivatives, purine bases and nucleosides, amino acids, and catecholamines etc. by CE with electrochemical detection.  相似文献   

5.
This paper describes the automation of a fully electrochemical system for preconcentration, cleanup, separation and detection, comprising the hyphenation of a thin layer electrochemical flow cell with CE coupled with contactless conductivity detection (CE-C?D). Traces of heavy metal ions were extracted from the pulsed-flowing sample and accumulated on a glassy carbon working electrode by electroreduction for some minutes. Anodic stripping of the accumulated metals was synchronized with hydrodynamic injection into the capillary. The effect of the angle of the slant polished tip of the CE capillary and its orientation against the working electrode in the electrochemical preconcentration (EPC) flow cell and of the accumulation time were studied, aiming at maximum CE-C?D signal enhancement. After 6 min of EPC, enhancement factors close to 50 times were obtained for thallium, lead, cadmium and copper ions, and about 16 for zinc ions. Limits of detection below 25 nmol/L were estimated for all target analytes but zinc. A second separation dimension was added to the CE separation capabilities by staircase scanning of the potentiostatic deposition and/or stripping potentials of metal ions, as implemented with the EPC-CE-C?D flow system. A matrix exchange between the deposition and stripping steps, highly valuable for sample cleanup, can be straightforwardly programmed with the multi-pumping flow management system. The automated simultaneous determination of the traces of five accumulable heavy metals together with four non-accumulated alkaline and alkaline earth metals in a single run was demonstrated, to highlight the potentiality of the system.  相似文献   

6.
An enhanced etched electrochemical (EC) detection technique has been developed for CE in micron inner diameter capillaries. The design improvements allow for better alignment between the capillary bore and the electrode. This new method involves utilizing a carbon fiber microelectrode and etching both the carbon fiber and the detection end of a micrometer-sized inner diameter capillary to limit dead volume and analyte diffusion at the amperometric EC detector. To understand the factors affecting enhanced detector efficiency, a detailed examination of the relationship between detector design and performance has been completed by exploring the effects of varying electrode diameter, tip shape, and size, in addition to the etch length of the capillary outlet. The enhanced detection provides peak efficiencies as high as 75000 theoretical plates and estimated detection limits as low as 40 nM for dopamine. This etched detection method should further facilitate volume-limited sample analysis by CE.  相似文献   

7.
Capillary electrophoresis coupled with electrochemical detection (CE-EC) for determination of antioxidants, propyl gallate (PG) and tert-butylhydroquinone (TBHQ), in cosmetic samples was proposed in this work. A porous etched joint was used to isolate the electrochemical detection from the electrophoretic high voltage. Compared with the 25 microm i.d. capillary without a decoupler in a CE-EC system, a 75 microm i.d. capillary applied in the present system gave an improvement in both sample injection and sensitivity. Moreover, the carbon fiber working electrode could be directly in touch with the end of separation capillary due to the elimination of the effect of separation voltage on the EC detection, so the alignment of working electrode and capillary became easy and the dead volume was also decreased. Baseline separation of the two antioxidants was achieved by CE in a 50 cm long x 75 microm i.d. capillary at 20 kV using 5.0 mmol L(-1) phosphate buffer (pH 8.00). 0.7 V (versus Ag/AgCl) was applied to the carbon fiber electrode for electrochemical detection. Under the optimal condition, the precisions (RSD, n=4) of peak height and migration time of PG and TBHQ were 2.39-3.59% and 0.34-0.44%, respectively. The detection limits of PG and TBHQ were 2.51x10(-6) and 4.88 x 10(-6) mol L(-1) for standard solution and 0.0751 and 0.0328 mg g(-1) for the real cosmetic samples with consumption of 0.3g sample. Analysis of TBHQ and PG in cosmetics samples was also achieved with the present system and the spiked recoveries of two analytes in cosmetics samples were in the range of 93.6-98.8%.  相似文献   

8.
A method for coupling an electrophoretic driven separation to a liquid flow, using conventional fused-silica capillaries and a soft polymeric interface is presented. A novel design of the electrode providing high voltage to the electrophoretic separation was also developed. The electrode consisted of a conductive polyimide/graphite imbedded coating immobilized onto the capillary electrophoresis (CE) column inlet. This integrated electrode gave the same separation performance as a commonly used platinum electrode. The on-column electrode also showed good electrochemical stability in chronoamperometric experiments. In addition, with this electrode design, the electrode position relative to the inlet end of the CE column will always be constant and well defined. The on-line flow injection analysis (FIA)-CE system was used with electrospray ionization (ESI)-time of flight (TOF)-mass spectrometry detection. The preparation of the PDMS (poly(dimethylsiloxane)) interface for FIA-CE is described in detail and used for initial tests of the on-column polymer-imbedded graphite inlet electrode. In this interface, a pressure-driven liquid flow, a make up CE electrolyte and a CE column inlet meet in a two-level cross (95 microm ID) in the PDMS structure, enabling independent flow characterization.  相似文献   

9.
付国妮  何友昭  王晓葵  王蕾 《色谱》2007,25(2):193-196
改进的毛细管电泳-间接紫外吸收法采用了自制隔离池,以对氨基苯甲酸(PAB)为背景电解质,对茶叶中的氨基酸进行了测定。PAB能够提高分离效率,降低检出限。隔离池的使用避免了PAB的电极反应,降低了基线噪声,维持了两缓冲液池间的电流导通。研究了背景电解质的浓度、pH值以及电渗流改性剂的种类和浓度对氨基酸分离的影响。在优化的实验条件下,16种氨基酸在14 min内达到了基线分离,峰面积的相对标准偏差小于5%(n=5),检出限为1.7~4.5 μmol/L,回收率为83.0%~106%。该法快速、便捷和灵敏,已成功应用于茶叶中11种游离氨基酸的检测。  相似文献   

10.
A new electrode has been developed and applied for amperometric detection in capillary electrophoresis (CE), comprised of carbon sol-gel composite material. The versatility of the sol-gel technique permits the flexible configuration of the electrode. The performance of such a sol-gel carbon composite electrode (CCE) is first evaluated in a typical CE application for the detection of purine-based compounds. Application of the CCE is also demonstrated for the detection of phenolic compounds in a micellar system. Separation resolution for non-ionic phenolic compounds can significantly be enhanced by introducing sodium dodecyl sulfate (SDS) at a concentration above its critical micelle concentration (cmc) to the buffer. Another design of the CCE incorporating the electrocatalyst Cu2O is employed for the analysis of sugars and organic acids based on dynamic modification with cetyltrimethylammonium bromide (CTAB). It has been found that the presence of surfactant in the separation buffer does not adversely influence the electrochemical detection using a sol-gel derived carbon electrode.  相似文献   

11.
A new electrode has been developed and applied for amperometric detection in capillary electrophoresis (CE), comprised of carbon sol-gel composite material. The versatility of the sol-gel technique permits the flexible configuration of the electrode. The performance of such a sol-gel carbon composite electrode (CCE) is first evaluated in a typical CE application for the detection of purine-based compounds. Application of the CCE is also demonstrated for the detection of phenolic compounds in a micellar system. Separation resolution for non-ionic phenolic compounds can significantly be enhanced by introducing sodium dodecyl sulfate (SDS) at a concentration above its critical micelle concentration (cmc) to the buffer. Another design of the CCE incorporating the electrocatalyst Cu2O is employed for the analysis of sugars and organic acids based on dynamic modification with cetyltrimethylammonium bromide (CTAB). It has been found that the presence of surfactant in the separation buffer does not adversely influence the electrochemical detection using a sol-gel derived carbon electrode.  相似文献   

12.
An in-capillary electrode sheathless interface was applied to the capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) analysis of mixtures of small peptides, proteins, and tryptic digests of proteins. The effects of different experimental parameters on the performance of this CE/ESI-MS interface were studied. The distance of the in-capillary electrode from the CE outlet and the length of the electrode inside the capillary had no significant effects on the CE separation and ESI behavior under the experimental conditions used. However, significant enhancement of the sensitivity resulted from the use of narrower CE capillaries. Using a quadrupole mass spectrometer, an aminopropylsilane-coated capillary, and a wide scan mass-to-charge ratio range of 500–1400, detection limits of approximately 4, 1, and 0.6 fmol for cytochrome c and myoglobin were achieved for 75-, 50-, and 30-µm inner diameter capillaries, respectively. Approximately one order of magnitude lower detection limits were achieved under the multiple-ion monitoring mode. The application of the in-capillary electrode sheathless interface to real-world samples was demonstrated by CE/ESI-MS analysis of a human blood sample.  相似文献   

13.
Yao X  Wang J  Zhang L  Yang P  Chen G 《Talanta》2006,69(5):1285-1291
A microchip capillary electrophoresis (CE)–amperometric detection (AD) system has been fabricated by integrating a two-dimensionally adjustable CE microchip and an amperometric detection cell containing a one-dimensionally adjustable disc detection electrode in a Plexiglas holder. It facilitates the precise three-dimensional alignment between the channel outlet and the detection electrode without a complicated three-dimensional manipulator. The performance of this unique system was demonstrated by separating four nitroaromatic pollutants (nitrobenzene, 2,4-dinitrotoluene, 2,4,6-trinitrotoluene, and p-nitrobenzene). Factors influencing their separation and detection processes were examined and optimised. The four analytes have been well-separated within 120 s in a 75 cm long separation channel at a separation voltage of +2000 V using an electrophoretic separation medium containing 15 mM borax and 15 mM sodium dodecyl sulfate (pH 9.2). Highly linear response is obtained for the four analytes over the range of 0–5 ppm with the detection limits ranging from 12 to 52 ppb. The present system demonstrated long-term stability and reproducibility with relative standard deviations of less than 5% for the peak current (n = 9). The new approach for the microchannel–electrode alignment should find a wide range of applications in other microfluidic analysis systems.  相似文献   

14.
Chen G  Bao H  Yang P 《Electrophoresis》2005,26(24):4632-4640
A microchip CE-amperometric detection (AD) system has been fabricated by integrating a two-dimensionally adjustable CE microchip and an AD cell containing a one-dimensionally adjustable disk detection electrode in a Plexiglas holder. It facilitates the precise 3-D alignment between the channel outlet and the detection electrode without a complicated 3-D manipulator. The performance of this unique system was demonstrated by separating five aromatic amines (1,4-phenyldiamine, aniline, 2-methylaniline, 4-chloroaniline, and 1-naphthylamine) of environmental concern. Factors influencing their separation and detection processes were examined and optimized. The five analytes have been well separated within 140 s in a 74 cm long separation channel at a separation voltage of +2500 V using a 10 mM phosphate buffer (pH 3.5). Highly linear response is obtained for the five analytes over the range 20-200 microM with the detection limits ranging from 0.46 to 1.44 microM, respectively. The present system demonstrated long-term stability and reproducibility with RSDs of less than 5% for the peak current (n = 9). The new approach for the microchannel-electrode alignment should find a wide range of applications in CE, flowing injection analysis, and other microfluidic analysis systems.  相似文献   

15.
Amperometric detector designs for capillary electrophoresis microchips   总被引:1,自引:0,他引:1  
Electrochemical (EC) detection is a sensitive and miniaturisable detection mode for capillary electrophoresis (CE) microchips. Detection cell design is very important in order to ensure electrical isolation from the high separation voltage. Amperometric detectors with different designs have been developed for coupling EC detection to CE-microchips. Different working electrode alignment: in-channel or end-channel has been tested in conjunction with several materials: gold, platinum or carbon. The end-channel detector was based on a platinum or gold wire manually aligned at the exit of the separation channel. Thick- (screen-printed carbon electrode) and thin-film (sputtered gold film) electrodes have also been employed with this configuration, but with a different design that allowed the rapid replacement of the electrode. The in-channel detector was based on a gold film within the separation channel. A gold-based dual electrode detector, which combined for the first time in- and end-channel detection, has been also tested. These amperometric detectors have been evaluated in combination to poly(methylmethacrylate) (PMMA) and Topas (thermoplastic olefin polymer of amorphous structure) CE-microchips. Topas is a new and promising cyclic olefin copolymer with high chemical resistance. Relevant parameters of the polymer microchip separation such as precision, efficiency or resolution and amperometric detection were studied with the different detector designs using p-aminophenol and L-ascorbic acid as model analytes in Tris-based buffer pH 9.0.  相似文献   

16.
《Electroanalysis》2005,17(13):1133-1140
Electrochemistry detection offers considerable promise for capillary‐electrophoresis (CE) microchips, with features that include remarkable sensitivity, portability, independence of optical path length or sample turbidity, low cost and power requirements, and high compatibility with modern micromachining technologies. This article highlights key strategies in controlled‐potential electrochemical detectors for CE microchip systems, along with recent advances and directions. Subjects covered include the design of the electrochemical detection system, its requirements and operational principles, common electrode materials, isolation from the separation voltage, derivatization reactions, typical applications, and future prospects. It is expected that electrochemical detection will become a powerful tool for CE microchip systems and will lead to the creation of truly portable (and possibly disposable) devices.  相似文献   

17.
Woods LA  Roddy TP  Ewing AG 《Electrophoresis》2004,25(9):1181-1187
Capillary electrophoresis (CE) has been established as powerful tool for single cell analysis. Newly developed sampling, separation and detection methods have allowed the investigation of single mammalian cells with CE despite their small size and complex composition. Advances in sample injection techniques include several novel methods for the injection of whole cells and sampling techniques for the study of cellular secretion. CE of single mammalian cells has been applied in a wide range of fields including protein analysis, neuroscience, and oncology. The development of new detection schemes in the analysis of single mammalian cells with CE has included studies of protein expression and the utilization of mass spectrometric and electrochemical detection. Subcellular mammalian cell analysis with CE also has been investigated.  相似文献   

18.
A capillary electrophoresis (CE) microchip made of a new and promising polymeric material: Topas (thermoplastic olefin polymer of amorphous structure), a cyclic olefin copolymer with high chemical resistance, has been tested for the first time with analytical purposes, employing an electrochemical detection. A simple end-channel platinum amperometric detector has been designed, checked, and optimized in a poly-(methylmethacrylate) (PMMA) CE microchip. The end-channel design is based on a platinum wire manually aligned at the exit of the separation channel. This is a simple and durable detection in which the working electrode is not pretreated. H(2)O(2) was employed as model analyte to study the performance of the PMMA microchip and the detector. Factors influencing migration and detection processes were examined and optimized. Separation of H(2)O(2) and L-ascorbic acid (AsA) was developed in order to evaluate the efficiency of microchips using different buffer systems. This detection has been checked for the first time with a microchip made of Topas, obtaining a good linear relationship for mixtures of H(2)O(2) and AsA in different buffers.  相似文献   

19.
Wang Y  Chen H  He Q  Soper SA 《Electrophoresis》2008,29(9):1881-1888
A fully integrated polycarbonate (PC) microchip for CE with end-channel electrochemical detection operated in an amperometric mode (CE-ED) has been developed. The on-chip integrated three-electrode system consisted of a gold working electrode, an Ag/AgCl reference electrode and a platinum counter electrode, which was fabricated by photo-directed electroless plating combined with electroplating. The working electrode was positioned against the separation channel exit to reduce post-channel band broadening. The electrophoresis high-voltage (HV) interference with the amperometric detection was assessed with respect to detection noise and potential shifts at various working-to-reference electrode spacing. It was observed that the electrophoresis HV interference caused by positioning the working electrode against the channel exit could be diminished by using an on-chip integrated reference electrode that was positioned in close proximity (100 microm) to the working electrode. The CE-ED microchip was demonstrated for the separation of model analytes, including dopamine (DA) and catechol (CA). Detection limits of 132 and 164 nM were achieved for DA and CA, respectively, and a theoretical plate number of 2.5x10(4)/m was obtained for DA. Relative standard deviations in peak heights observed for five runs of a standard solution containing the two analytes (0.1 mM for each) were 1.2 and 3.1% for DA and CA, respectively. The chip could be continuously used for more than 8 h without significant deterioration in analytical performance.  相似文献   

20.
Summary Capillary electrophoresis (CE) has been employed for the separation of monoamine transmitters (MAs) and tyrosine (Tyr), combined with electrochemical detection (ED) at a carbon disc electrode. The effects of several factors such as the acidity and concentration of running buffer, the separation voltage, the potential applied to the working electrode and the injection time were investigated to find the optimum conditions. Detection limits (S/N=3) ranged from 48.8 to 315.4 nmol·L−1, and the response was linear over 3 order of magnitude for MAs and Tyr. The proposed method was successfully applied to determine MAs and Tyr in the cerebral cortex, thalamus and spinal cord of rats with satisfactory assay results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号