首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A simple, rapid, and efficient method, vortex‐assisted extraction followed by dispersive liquid–liquid microextraction (DLLME) has been developed for the extraction of polycyclic aromatic hydrocarbons (PAHs) in sediment samples prior to analysis by high performance liquid chromatography fluorescence detection. Acetonitrile was used as collecting solvent for the extraction of PAHs from sediment by vortex‐assisted extraction. In DLLME, PAHs were rapidly transferred from acetonitrile to dichloromethane. Under the optimum conditions, the method yields a linear calibration curve in the concentration range from 10 to 2100 ng g?1 for fluorene, anthracene, chrysene, benzo[k]fluoranthene, and benzo[a]pyrene, and 20 to 2100 ng g?1 for other target analytes. Coefficients of determinations ranged from 0.9986 to 0.9994. The limits of detection, based on signal‐to‐noise ratio of three, ranged from 2.3 to 6.8 ng g?1. Reproducibility and recoveries was assessed by extracting a series of six independent sediment samples, which were spiked with different concentration levels. Finally, the proposed method was successfully applied in analyses of real nature sediment samples. The proposed method extended and improved the application of DLLME to solid samples, which greatly shorten the extraction time and simplified the extraction process.  相似文献   

2.
A method for the determination of 27 polycyclic aromatic hydrocarbons (PAHs) in sludge from wastewater treatment plants (WWTPs) located in urban, industrial or rural zones is presented. PAHs were extracted by matrix solid-phase dispersion (MSPD) assisted by sonication. Purification of extracts was carried out by solid-phase extraction with C(18) and PAHs were eluted with acetonitrile. PAHs were determined by isotope dilution gas chromatography with electron impact mass spectrometric detection in the selected ion-monitoring mode (GC-MS-SIM), using deuterated PAHs as internal standards. The limits of detection ranged from 0.03 ng/g for acenaphthylene to 0.45 ng/g for benzo[b]naphtho[2,1-d]thyophene. After optimization, the method was validated with a certified reference sludge. The proposed analytical method was applied to determine PAH levels in sewage sludge samples collected from 19 water treatment plants located in the province of Madrid (Spain). In most of the examined samples, phenanthrene was the main compound with a mean concentration of 1062 ng/g. PAHs were detected in all of the samples, with total concentrations between 390 and 6390 ng/g dry weight for the 27 PAHs analyzed and from 310 to 5120 ng/g dry weight for the sum of the 10 PAHs considered in the draft European Union directive.  相似文献   

3.
European food legislation defines a set of 16 polycyclic aromatic hydrocarbons (PAHs) as of high concern for human health. The EU set contains structurally very similar PAHs with ring numbers between 4 and 6, and so raises some separation aspects and problems, which were not experienced with traditionally analysed PAHs. Many of the currently applied gas chromatographic mass spectrometric (GC-MS) methods suffer from separation problems, while high performance liquid chromatography with fluorescence detection (HPLC-FLD) is neither capable of detecting the whole set of EU priority PAHs nor does it (compared to GC-MS) allow structural identification. In addition HPLC-FLD shows limitations with difficult matrices due to interferences. The aim of this paper is to fill this gap by describing a liquid chromatographic dopant assisted atmospheric pressure photo ionisation tandem mass spectrometric (LC-DA-APPI-MS/MS) method for the determination of 15+1 EU priority PAHs in edible oil, which complies with the requirements set by European food legislation. Measurements were performed in positive ion mode. Anisole at a flow rate of 30 μl/min was used as dopant. Sample preparation was performed offline by donor-acceptor complex chromatography (DACC). Compared to HPLC-FLD methods the presented method enables the determination of all 15+1 EU priority PAHs at the low μg/kg concentration range including less fluorescence active compounds like benzo[j]fluoranthene and indeno[1,2,3-cd]pyrene. By analysing four reference materials it could be demonstrated that this method provides accurate results and is sufficiently sensitive for food control purposes. Statistically significant differences between the reference values and the measured analyte contents were not found. The method performs well also for very complex samples. Repeatability relative standard deviations (RSDr) of the determination of the target PAHs in olive oil were for most analytes below 5%. The limit of detection (LOD) of the method met the requirement set by EU legislation (0.3 μg/kg).  相似文献   

4.
A simplified extraction method was developed for extracting high molecular weight polycyclic aromatic hydrocarbons (PAHs) from river sediments. The samples were extracted 3 times with 5 mL of solvent (toluene:methanol, 9 : 1, v/v) at 100 °C, 10 minutes for each extraction. After clean‐up and concentration, extracts were analyzed by gas chromatography coupled with mass spectrometer (GC‐MS). The extraction efficiency and accuracy was evaluated by the standard reference material (SRM‐1941b). Comparing to certified values, the average recoveries of high molecular weight PAHs with 3, 4, 5 and 6 fused benzene rings were 72.9∼113.2 % (R.S.D. 2.3∼6.3 %) except those of dibenz[a,h]anthracene (206.2±4.6 %). The average recoveries for PAHs spiked sediment samples were comparable with accelerated solvent extraction (ASE) and Soxhlet methods. The simple extraction method consumes less solvent, fewer amount of sample than those of conventional methods. The lowest quantitation limit of PAHs is 1.1 μg/kg.  相似文献   

5.
The objective of this study was the optimization and comparison of two extraction methods for the determination of polycyclic aromatic hydrocarbons (PAHs) in wastewater (WW). A distribution study of the target compounds between the aqueous phase and the suspended particulate matter (SPM) has been performed in order to establish whether the analysis of both phases is necessary. In this sense, the feasibility of stir bar sorptive extraction (SBSE) and solid-phase extraction (SPE) for the determination of 24 PAHs in WW samples has been evaluated. The results demonstrated the suitability of SBSE to perform a comprehensive analysis of liquid samples containing high amounts of SPM, such as in the determination of PAHs in WWs. A gas chromatography triple quadrupole mass spectrometry (GC-QqQ-MS/MS) method has been also optimized for the separation and detection of the target compounds, avoiding the co-elution of some groups of isomers, such as benzo[b], [j] and [k] fluoranthenes and indene[1,2,3-cd]pyrene/dibenz[a,h]anthracene. For that purpose, a specific capillary column developed for PAH determination was used. The SBSE procedure was validated and adequate parameters (such as recovery, linearity, precision, limits of detection and quantification) were obtained. Finally, the validated method was applied to the analysis of real samples collected from an experimental WW treatment plant, detecting some PAHs at concentrations in the range 0.007-0.022 μg L(-1).  相似文献   

6.
复杂基体中痕量多环芳烃分析测定方法的研究进展   总被引:15,自引:0,他引:15  
董新艳  杨亦文  任其龙 《色谱》2005,23(6):609-615
介绍了环境样品(水和土壤)以及植物油中痕量多环芳烃的分析检测方法。对样品的预处理过程和分析方法做了评价。采用一些新的预处理方法(包括液相色谱法、固相萃取法、超临界二氧化碳萃取法),并结合色谱-质谱在线联用分析检测方法能够获得比较理想的分析结果。引用文献52篇。  相似文献   

7.
A fast and simple preparation procedure based on the matrix solid-phase dispersion (MSPD) technique is proposed for the first time for the isolation of 16 polycyclic aromatic hydrocarbons (PAHs) from soil samples. Naphthalene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[e]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenzo[a,h]anthracene, benzo[g,h,i]perylene, and indeno[1,2,3-c,d]pyrene were considered in the study. Extraction and clean-up of samples were carried out in a single step. The main parameters that affect extraction yield, such as dispersant, type and amount of additives, clean-up co-sorbent and extractive solvent were evaluated and optimized. The addition of an alkali solution in MSPD was required to provide quantitative recoveries. Analytical determinations were carried out by high performance liquid chromatography (HPLC) with fluorescence detection. Quantification limits (between 0.01 and 0.6 ng g(-1) dry mass) were well below the regulatory limits for all the compounds considered. The extraction yields for the different compounds obtained by MSPD were compared with the yields obtained by microwave-assisted extraction (MAE). To test the accuracy of the MSPD technique, the optimized methodology was applied to the analysis of standard reference material BCR-524 (contaminated industrial soil), with excellent results.  相似文献   

8.
The performance of matrix solid-phase dispersion (MSPD) for the extraction of polycyclic aromatic hydrocarbons (PAHs) in fish tissue is described. The suitability of different solid supports was tested as well as the influence on the extraction efficiency of the natural fat content in samples. Under optimal conditions 0.6-0.8 g of tissue sample, are dispersed with 2 g of octadecylsiloxane (C18) and 0.5 g of anhydrous sodium sulphate and transferred to the top of a polyethylene solid-phase extraction cartridge which already contains 2 g of florisil and 1 g of C18. Cartridges were eluted with acetonitrile. The analysis of the extracts was carried out by high-performance liquid chromatography (HPLC) coupled with fluorescence detection. The proposed method provides detection limits between 0.04 and 0.32 ng/g for the different considered PAHs, below the maximum levels established by the some regulatory bodies for the six PAHs after recent oil spill episodes and European Union regulations. Recoveries over 80% were obtained for all compounds. Accuracy validation was carried out using the US National Institute of Standards and Technology (NIST) SRM 2977 reference material.  相似文献   

9.
Shi XZ  Song SQ  Sun AL  Liu JH  Li DX  Chen J 《The Analyst》2012,137(2):437-443
A simple, efficient, and environmentally friendly membrane-assisted solvent extraction (MASE) method for the extraction and preconcentration of six pyrethroid insecticides from aquaculture seawater samples followed by gas chromatography-electron capture detection (GC-ECD) was successfully proposed. The operating conditions for MASE, such as the extraction solvent, solvent volume, NaCl concentration, stirring rate, extraction time, and temperature, were optimized. Compared to conventional Florisil-solid phase extraction (SPE), higher extraction recoveries (85.9% to 105.9%) of three spiked levels of the six pyrethroid pesticides in aquaculture seawater were obtained using MASE, and the RSD values were lower than 7.9%. The limits of detection (LOD, signal-to-noise ratio (S/N)=3) and quantification (LOQ, S/N = 10) were in the range of 0.037-0.166 and 0.12-0.55 μg L(-1), respectively. The results demonstrate the excellent applicability of the MASE method in analyzing the six pyrethroid pesticides in aqueous samples. The proposed method exhibited a high potential for routine monitoring analysis of pyrethroid insecticides in seawater samples.  相似文献   

10.
<正>Triacontyl modified silica gel as a sorbent coupled with gas chromatography-mass spectrometry(GC-MS) was developed to determine EPA prior 16 polycyclic aromatic hydrocarbons(PAHs) in water samples.Various parameters of solid-phase extraction such as organic modifier solvent,eluent,sample flow rate and volume were optimized.The developed method was found to yield a linear calibration curve in the concentration range of 0.05-8μg/L with respect to naphthalene,acenaphthylene,acenaphthene and 0.01-8μg/L for dibenz[a,h]anthracene and 0.05-14μg/L for fluorene,phenanthrene,anthracene and 0.01-14μg/L for the rest of analytes.Furthermore,the good accuracy and repeatability of the method made sure the requirements for achieving reliable analysis of PAHs in the environmental water samples,and the recoveries of optimal method were in the range of 80-120%except to higher volatility PAHs.C_(30)-bonded silica was proved to be an efficient sorbent for extraction of high molecular weight PAHs.  相似文献   

11.
A multiresidue method for the determination of phenoxyalkanoic acid herbicides and their phenolic conversion products in soil was developed. The method was based on microwave-assisted solvent extraction (MASE) of soil samples by an aqueous methanolic mixture and subsequent analysis of extracts by automated solid-phase extraction followed by on-line high-performance liquid chromatography and diode array detection. MASE parameters (extraction temperature and time, composition of the extraction mixture and extraction volume) were optimized with respect to analyte recoveries. The method was validated with two types of soils containing 1.5 and 3.5% organic matter, respectively, both types containing fresh and aged residues of sought analytes. Under the selected analytical conditions when soils with fresh residues were analyzed all target analytes were recovered above 80% from the soil containing 1.5% organic matter, while limits of identification at the level of 20-40 ng/g were achieved. From the soil containing 3.5% organic matter the least polar phenolic analytes exhibited slightly reduced recoveries, while identification limits of 30-50 ng/g were achieved. Samples with aged residues exhibited reduced recoveries for some analytes, the reduction amounting up to 6-12% within 1 month of aging period depending on soil organic matter.  相似文献   

12.
To detect, identify, and quantify the polycyclic aromatic hydrocarbons (PAHs) released into the environment, the PAHs need to be isolated from the soil matrix. In this work, a modified quick, easy, cheap, efficient, rugged and safe (QuEChERS) method with ionic liquid was combined with liquid chromatography to identify 16 selected PAHs in soil. Ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim]PF6) was applied as an extractant component to enhance the process. The [Hmim]PF6 content in acetonitrile (ACN) was optimized. The [Hmim]PF6 modified QuEChERS method has the advantages defined by its name and a similar recovery to other extraction methods reported in the literature. Adding [Hmim]PF6 may eliminate the co-extract proportion and achieve a more effective extraction. Compared with ACN alone, the matrix effect (ME) of ACN containing 5% [Hmim]PF6 was reduced by approximately 35%. Additionally, the ME of using ACN containing [Hmim]PF6 without a clean-up procedure was similar to that of using ACN followed by a clean-up procedure. The recoveries of the QuEChERS method implemented with [Hmim]PF6 ranged from 75.19% to 100.98%. The limits of detection (LOD) and limits of quantification (LOQ) ranged from 0.86 to 4.51 µg/kg and from 2.87 to 15.13 µg/kg, respectively.  相似文献   

13.
The aim of this study was to develop an analytical method to determine the organochlorine concentrations in sediments. Combination of Microwave assisted Solvent Extraction (MASE) and capillary gas chromatography with specific detection (electron capture detector) was a viable approach for the determination of pesticides in solid matrixes. In this study, MASE development was focused on the selection of a suitable extraction solvent for all the target analytes. MASE procedure was validated by comparison with conventional methods such as Soxhlet and sonication extraction. The proposed method was then applied to determine the organochlorine insecticides concentrations in samples from Authie Bay (France). Environmental water samples were analysed and five target analytes were detected in concentrations from 0.03 to 0.56 ng/g of dry sediment. These investigations showed the accumulation and the persistency of these products in sediments in spite of the fact they were banned a few decades ago.  相似文献   

14.
A method for the determination of some polynuclear aromatic hydrocarbons (PAHs) in water samples and air filters is presented. Samples were extracted with light petroleum-diethyl ether (85 + 15) and the extracts were concentrated before analysis. Reversed-phase liquid chromatography with fluorescence detection was applied to separate and determine the PAHs. Recoveries of individual PAHs from spiked water samples were 0.16–0.27 ng ml?1. Detection limits in the picogram range were obtained for each compound.  相似文献   

15.
There is a need for a better characterization of sludges from wastewater treatment plants which are destined to be spread on agricultural lands. Inorganic pollutants are regularly controlled but organic pollutants have received few attention up to now. On this paper, we have been interested on the analysis of the 16 polycyclic aromatic hydrocarbons (PAHs) listed in the US Environmental Protection Agency (US EPA) priority list and more particularly of the six PAHs listed in the European community list (fluoranthene, benzo[b and k]fluoranthene, benzo[a]pyrene, benzo[ghi]perylene, indeno[1,2,3-cd]pyrene). The analysis step consists on liquid chromatography with both fluorescence and UV detections as described in the EPA Method 8310. As for the extraction step, several techniques such as supercritical fluid extraction, pressurized liquid extraction, focused microwave extraction in open vessels, Soxhlet and ultrasonic extractions are compared after optimization of the experimental conditions (solvent nature and quantity, temperature, pressure, duration, ... ) and validation with certified sludges. When optimized, these five extraction techniques are as much efficient with similar relative standard deviation. Whatever the extraction techniques used, the whole analysis protocol permits to quantify PAHs in the range of 0.09 to 0.9 mg/kg of dried sludges.  相似文献   

16.
A simultaneous matrix solid-phase dispersion extraction-gel permeation chromatography cleanup with programmed temperature vaporisation GC-MS determination is proposed for the analysis of parent and alkylated polycyclic aromatic hydrocarbons (PAHs) in mussel samples. The parameters affecting the extraction and elution efficiency were studied. Final conditions were: 0.5?g of mussel sample, 0.5?g diatomaceous earth as dispersant; and 4?g of Bio-Beads S-X3 for the gel permeation chromatography. Ethyl acetate/hexane (1:1, v/v) was selected for the elimination of the lipid fraction and the elution of PAHs. The detection and quantification limits achieved with this procedure were between 0.01?μg/kg and 0.67?μg/kg and 0.02?μg/kg and 1.93?μg/kg, respectively. The linearity of the method ranged between 5?μg/kg and 1000?μg/kg for most of the studied PAHs. The method was validated by the analysis of mussel tissue reference material (SRM 2977). The repeatability, intermediate precision and accuracy of the method obtained are in excellent agreement with the certified values. The proposed method is simple, precise and robust; no special instruments or costly equipment are required, and a reduction in the total time of analysis, sample handling and solvent consumption is achieved in comparison with classic procedures.  相似文献   

17.
Long Y  Chen Y  Yang F  Chen C  Pan D  Cai Q  Yao S 《The Analyst》2012,137(11):2716-2722
Triphenylamine (TPA)-functionalized magnetic microspheres (Fe(3)O(4)/SiO(2)/TPA) were prepared and applied as solid phase extraction (SPE) adsorbents for the analysis of polycyclic aromatic hydrocarbons (PAHs) in environmental samples in combination with high-performance liquid chromatography (HPLC). The magnetic solid-phase extraction (MSPE) conditions affecting the extraction efficiency were optimized, including elution solvent, standing time, amount of sorbent, and salt concentration. Due to the strong π-π conjugate effect between the benzene rings of TPA and PAHs, high extraction efficiency was achieved with spiked recoveries of 80.21-108.33% and relative standard deviations (RSD) of less than 10%. Good linearities (R(2) > 0.997) for all calibration curves were obtained with low limits of detection (LOD) of 0.25, 0.5, 0.5, 3.75, 0.2 and 0.04 ng L(-1) for anthracene, fluoranthene, pyrene, chrysene, benzo[b]fluoranthene and benzo[k]fluoranthene, respectively. The achieved results indicate the applicability of Fe(3)O(4)/SiO(2)/TPA as MSPE adsorbents.  相似文献   

18.
Analyte extraction is the main limitation when developing at-line, or on-line, procedures for the preparation of (semi)solid environmental samples. Pressurised liquid extraction (PLE) is an analyte- and matrix-independent technique which provides cleaner extracts than the time-consuming classical procedures. In the study, the practicality of miniaturised PLE performed in a stainless-steel cell, and combined with subsequent large-volume injection (LVI)-GC-MS was studied. As an example, the new system was applied to the determination of polycyclic aromatic hydrocarbons (PAHs) in soils and a sediment. Variables affecting the PLE efficiency, such as pressure and temperature of the extraction solvent and total solvent volume, were studied. Toluene was selected as extraction solvent and a total solvent volume of 100 microl was used for the 10 min static-dynamic PLE of 50-mg samples. Additional clean-up or filtration of the sample extracts was not required. Detection limits using LVI-GC-MS were below 9 ng/g soil for the 13 PAHs more volatile than indeno[1,2,3-cd]pyrene in real soil samples and the repeatability of the complete PLE plus LVI-GC-MS method for the analysis of the endogenous PAH was better than 15%. Comparison of PLE and Soxhlet or liquid-partitioning extraction results for the analysis of non-spiked samples showed that the efficiency of PLE is the same or better than for the other two extraction methods assayed.  相似文献   

19.
杨然存  张少文  孙雨安 《色谱》2015,33(5):455-460
利用点击反应对含叠氮基的溶胶-凝胶整体柱进行了表面修饰,制备了C6-硅胶杂化整体萃取柱。实验以多环芳烃为分析对象,考察了制备和修饰条件对萃取效率的影响,在优化的条件下,新制备的整体柱对萘、菲、芘和苯并[a]芘的萃取富集倍数分别达到95.9、114.2、103.2和57.8。萃取实验的日内和日间精密度(RSD)分别小于5.5%(n=8)和7.3%(n=10)。建立的管内固相微萃取-高效液相色谱检测16种常见多环芳烃方法的检出限(S/N=3)达到0.08~3.72 μg/L,定量限(S/N=10)达到0.26~12.40 μg/L。土壤中多环芳烃分析的加标回收率为82.4%~110.6%, RSD为2.6%~7.9%(n=3)。与美国国家环境保护局检测土壤中多环芳烃的方法比较,结果一致,准确性高。实验表明,该方法萃取效率高,灵敏可靠,操作简便,重现性好,可满足土壤等样品中痕量多环芳烃检测的要求。  相似文献   

20.
Membrane-assisted solvent extraction (MASE) in combination with large volume injection-gas chromatography-mass spectrometry (LVI-GC-MS) was applied for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. The MASE conditions were optimized for achieving high enrichment of the analytes from aqueous samples, in terms of extraction conditions (shaking speed, extraction temperature and time), extraction solvent and composition (ionic strength, sample pH and presence of organic solvent). Parameters like linearity and reproducibility of the procedure were determined. The extraction efficiency was above 65% for all the analytes and the relative standard deviation (RSD) for five consecutive extractions ranged from 6 to 18%. At optimized conditions detection limits at the ng/L level were achieved. The effectiveness of the method was tested by analyzing real samples, such as river water, apple juice, red wine and milk.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号